ECM HIGH EFFICIENCY CIRCULATORS

Similar documents
FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE

FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

ELECTRONIC THERMOSTAT: T920

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

Submittal Packages Detailed with Items and Reviewers

BAS Integration Manual

BACnet- MS/TP COMMUNICATION V

Cetetherm IQ Heat Midi/Maxi

University of Rochester Design Standard August 13, 2014

Modbus VAV Controller Configuration Properties

OCCUPANCY SENSOR REMOTE USER GUIDE

Submittal Data Sheet Wilo MVI - Vertical Multistage Pumps

Calio SI First and only circulator designed and produced in Turkey

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't

PowerFlex 400 AC Drive Guide Specification

DeltaSol MX. Certifi ed for the North American market! CONTROL TECHNOLOGY. incl.

PROCESS & TEMPERATURE CONTROLLERS

APPLICATION GUIDE Delta Network Sensor Thermostat: BACstat II DNS-24, DNT-T103, & DNT-T221 Document Edition 3.1

Sauter Components

B850 Boiler House Energy Monitor

VT8300 Series Installation Guide 24 Vac Low Voltage

Variable Frequency Drives

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

TC 204 Heating Controller

BACnet Protocol Implementation Conformance Statement

B850 Boiler House Energy Monitor

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

About AB Industrietechnik

Modbus communication module for TCX2: AEX-MOD

NX Series Inverters. HVAC Pocket Programming Guide

DC CIRCUITS Part I of III Parts. Part II installation. Part III troubleshooting

CONTROL MANUAL. Dry-Pic 09PE - 09VE

ADAM-4022T Serial Base Dual Loops PID Controller User s Manual

TLC3-BCR-U Series Thermostat

vacon 100 flow ac drives application manual

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

Understanding Electronic Controls Diagrams

Adjustable Frequency Drive Fundamentals By Rick Porembski Of The Sandberg Div. of Bornquist.

VARIABLE FREQUENCY DRIVE SPECIFICATION

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1

BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

Troubleshooting Guide for Aquatrac Smart AS and Flex

BACnet Protocol Implementation Conformance Statement

Electronic pressure-independent characterised control valve with energy monitoring

SonoMeter 31 Energy Meters

Installation Guide. ECL Comfort 310, application A Table of Contents

E l e c t r o m a g n e t i c f l o w m e t e r s

SE7000 Series Application guide

CONTENTS Project name WMHpc Revision 1.3

Universal Controller

Application Note CTAN #287

BATCHMATE 1500 Batch Control Computer Technical Bulletin

1-2 VOLTS PER HERTZ CHARACTERISTICS EXERCISE OBJECTIVE

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

FPS. FPS Flexible Position Sensor. Function description. Your advantages and benefits

TI25 - Pre-Instructional Survey

Modbus Integration Integration for Modbus Functionality for VT8300 Series

Metasys Zoning Package Commissioning

Worcester Controls PB SMART PRODUCTS

Introduction to BLDC Motor Control Using Freescale MCU. Tom Wang Segment Biz. Dev. Manager Avnet Electronics Marketing Asia

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide

AEROCONNECT 1B NA C Control manual

SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

BandMaster V Manual. Installation

REH FC-BMS3 Modbus Manual

Electronic pressure-independent characterised control valve with energy monitoring

MODEL G0632Z 16" X 42" VARIABLE- SPEED WOOD LATHE MANUAL INSERT

Building Intelligence

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3

Magnetostrictive Level Transmitter

Optidrive Applications Support Library

Signet 9950 Dual Channel Transmitter

VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

Installation, Programming Operation, & Maintenance Manual V

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

W I R E L E S S L I N E C A R D

Signet 9950 Dual Channel Transmitter

Control solutions Biofloor

Touch-Plate BACnet Catalog

BOILER MANAGEMENT SYSTEM

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER

Introduction to BAS Technology

VFD 101 Lesson 1. Functions of an Variable Frequency Drive (VFD)

A Super trainer with advanced hardware and software features only found in very expensive equipment.

RE92. CHECKMATE. Dual loop controller for industry purpose.

SITRANS L Level instruments

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682

Plug & Play. No Calibration Required

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

Heat Exchanger Construction Checklist

GPS-G5 User s Manual

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

Experiment#6: Speaker Control

POSICHRON position sensor in a stainless steel pressure tube. Protection class IP68/IP69K

8V General information. 2 Order data 8V

Transcription:

ECM HIGH EFFICIENCY CIRCULATORS WILO STRATOS

Stratos Commercial high efficiency pumpp Main features & benefits 0-285 Gal/min flow 3 40 ft head 8 models (1.25, 1.5, 2 & 3 ) EC motor (permanent magnet rotor) Automatically ti adjusts to system demands d No external sensors required Easy setup via red button Water temperature from 14⁰F to 230⁰F Constant t pressure control mode Variable pressure control mode Temperature control mode BMS options: LON & Bacnet, 0-10V Infrared device for remote control & setup Excellent warranty 24/18 months UNIQUE FEATURES & UP TO 80% Q ENERGY SAVINGS!

Stratos-D (dual-power head pump) p) 2 & 3 size models Flow up to 450 gpm IF modules required Duty/Standby mode Lead/Lag mode Space saving Accessories saving

Sratos-Z for Domestic Hot Water Cast S. Steel volute EC Motor Built-in VFD T⁰ control with 0-10V IF 0-160 GPM @ 40-3 NSF/ANSI 61-G certified pump

ECM Technology Commutation (reverse currents) Coil 1 Coil 4 Coil 2 Coil 3

Speed Control Electronic continuous speed control (Constant Pressure) > Automatic differential e pressure e control o n max 1. The brain determined the actual pumping head. (actual value) Pumping Head H [F Ft] H 2 H 1 3 2 Constant speed pump 1 2. The drive sees the difference between the set value (point 1) and the actual value. (point 2) 3. Via ECM smart technology the controller reduces the speed and reduced the pumping head to match the system curve. (point 3) Q 1 Q 2 Flow Q [USGPM]

Built In Control Modes P C C (Constant Pressure Differential) Control Mode On site setting via red button Can be adjusted from 3ft to max pump head Pump will vary the flow but keep a constant diff. pressure Built-in control mode, does not require external sensors Recommended in low resistance systems or in-floor heating loops zoning In the example above, the pump is set to maintain 20 ft constant differential pressure. The flow will modulate from 0 to 230 gpm.

Built In Control Modes Constant Speed Control Mode Max Set speed 2210 rpm Min On site setting via red button Can be adjusted from Min to Max speed with 10 rpm increments Built-in control mode, does not require external sensors Recommended in fixed flow/head application In the example above, the pump is set to 2210 rpm. Minimum and Maximum speeds vary depending on pumps models.

Built In Control Modes P V (Variable Pressure Differential) Control Mode On site setting via red button Can be adjusted from 3ft to max pump head Pump will automatically vary the flow and the head on system demand. Min head at 0 flow is half the max head set Built-in model, does not require external sensors Recommended in high resistance systems In the example above, the pump is set to maintain 24 ft differential pressure at maximum flow. As the flow decreases, the head decreases proportionally.

Built In Control Modes P T T (Temperature Pressure Differential) Control Mode Change in temperature at the pump changes the pressure setpoint IR tool required to activate and set perameters Stratos t installed on return T Max T Min = > or = 50 deg. F T Max: 150 F H @ Max T: 10 T Max: 190 F H @ Max T: 7 T Min: 100 F H @ Max T: 30 T Min: 140 F H @ Max T: 25 Head Head 30 25 10 7 100 F 150 F Temp 190 F 140 F Temp Condensing Boiler Application Non-Condensing Boiler Application (Decreases delta P on temp rise) (Increases delta P on temp rise)

Power Supply 1ph 230V G FC 2 x 1ph 115V Check local electrical code 3ph 208/230V Acceptable input voltage: 195V min / 263V max

Interface modules for BMS communication

External Control Modes BUILDING MANAGEMENT SYSTEM Interface modules for: 0-10V DC Signal LON BACNET Dual pump operation

Inter-Face 0-10V/DP / Ext. Off 0 to 1 V: Pump Off 1 to 3V: Pump On / Minimum speed 3 to 10V: Speed modulation, 3V=Min and 10V-Max Ext. Off Contact: if closed losed = Pump On / if open = Pump Off

Inter-Face 0-10V/DP/Ext. Min 0 to 1 V: Pump On / Minimum speed 1 to 10V: Speed modulation, 1V=Min and 10V=Max Ext. Min Contact: if closed = Modulation / if open = Speed Min

Inter-Face 0-10V/DP/SBM 0 to 1 V: Pump Off 1 to 3V: Pump On / Minimum speed 3 to 10V: Speed modulation, 3V=Min and 10V-Max SBM Status Contact: if closed = Pump is On / if open = Pump is Off

Dual Pump Operation Dual pump operation Auto changeover Lead/Lag mode Duty/Standby mode Power Management

BACnet InterFace Module MS/TP SLAVE IF RS485 High Baud Rates Analog input/output Binary input/output Multistate input/output p Dual pump operation

LON InterFace Module FTT 10A transceiver High Baud Rates Analog input/output Binary input/output Multistate input/output XIF files available Dual pump operation

Interface (IF) modules for Stratos IF modules summary board Description Article # 0 10V Ext. Off Ext. Min Run (SBM) LON BacNet DP IF 0 10V/DP/Ext.Off 2030475 x x x IF 0 10V/DP/Ext.Min 2030485 x x x IF 0 10V/DP/SBM 2030495 x x x IF SBM/Ext.Off/DP 2084867 x x x IF LON 2030455 x x IF BacNet 2097810 x x Key: x = Available 0 10V = External 0 10V DC input signal Ext. Off = pump p start/stop contact Ext. Min = Default minimum speed contact SBM = Run status contact LON = BMS LON interface BacNet = BMS BacNet interface DP = Dual pump management

IR Remote Control Infra-Red remote control: O it i ti i On site communication via laptop Control setting Pump monitoring Data logging & saving