SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives

Similar documents
SINAMICS drives. SINAMICS DCM as a DC voltage source. Application. Answers for industry. Edition 01/2014

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

SINVERT. Technical requirements for medium-voltage transformers for use with SINVERT central inverters. Application manual 04/2012

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

SINAMICS DCM. DC converter Application - 12-pulse parallel connection with decoupled interphase transformer. Introduction 1

SIMATIC Vision Sensor SIMATIC VS130-2 and VS 130-2vcr

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

SINAMICS drives SINAMICS DCM. Commutation reactors. Operating Instructions. Answers for industry. Edition 11/2013

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMOREG DC-MASTER. Application 12-Pulse Parallel Applications. 6RA70 Series

SINAMICS. OALINK Open Application Link. Communication between two Control Units via DRIVE-CLiQ. Function Manual. Answers for industry.

Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) SIMATIC. ET 200SP Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Preface. Documentation guide 1

Function Manual Basic Positioner SINAMICS. SINAMICS G120 Function Manual Basic Positioner. Introduction. Basic positioner. Appendix.

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AI U HS analog electronic module (6ES7134-4FB52-0AB0) Preface. Properties 1. Parameters 2.

Technology module TM Pulse 2x24V (6ES7138 6DB00 0BB1) SIMATIC ET 200SP (6ES7138 6DB00 0BB1) Preface. Documentation guide.

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions

Positioning SIMATIC. ET 200S Positioning. Preface 1 1STEP 5V. 1PosUniversal. Operating Instructions 06/2010 A5E

Drive System Application

COOPER POWER SERIES. Upgrade instructions for CL-6 series control firmware. Voltage Regulators MN225071EN

SIMATIC Ident. RFID systems SIMATIC RF200 IO-Link V1.1. Introduction 1. Description. System overview. Planning an RF200 IO-Link system 4

Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) SIMATIC. ET 200SP Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) Preface

COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

Low-Voltage Power Distribution and Electrical Installation Technology

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

SINAMICS. VIBX Vibration Extinction. Function Manual

13 A. Temperature regulator FM SIMATIC. S7-300 Temperature regulator FM Preface. Product Overview

Service Manual for Installers Troubleshooting for Power-Line Communication SUNNY BOY 240-US / SUNNY MULTIGATE-US

CPH Coulter Tool Bar Brace Assembly

Drive System Application

Isometrics COMOS. Process Isometrics. Trademarks 1. Introduction 2. Project structure 3. Isometric report 4. Engineering with COMOS Isometrics

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

PBM-UNI Installation Guide

BT D. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data. 4Q Triac

SITRANS TH200/TH300 SITRANS T. Temperature transmitter SITRANS TH200/TH300. Introduction 1. General safety notes. Description 3.

Dynamo Brushless DC Motor and GreenDriveTM Manual

Installation Instructions

External brake resistor AX2090-BW5x

Qualified for industrial applications according to the relevant tests of JEDEC47/20/22.

5 V, 1 A H-Bridge Motor Driver

BT G0T. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data. 4Q Triac

Small Signal Switching Diode, Dual

Galaxy VM. Kit for IP32. Installation 06/

C-Bus 8 Channel Low Voltage Relay

Wenger Corporation 2010 Printed in China 02/10 Part #148H Wenger Corporation, 555 Park Drive, P.O. Box 448, Owatonna, Minnesota

BYV10ED-600P Ultrafast power diode 4 July 2017 Product data sheet

Product Manual SENTRON. Measuring Devices 7KM PAC3200T. siemens.com/lowvoltage

Small Signal Fast Switching Diode

Single Phase Bridge Rectifier, 2 A

ZMY3V9 to ZMY100. Zener Diodes. Vishay Semiconductors

Table 1. Quick reference data Symbol Parameter Conditions Values Unit Absolute maximum rating V DRM repetitive peak off-state

ON!Track smart tag AI T380. English. Printed: Doc-Nr: PUB / / 000 / 02

SINAMICS G120. Frequenzumrichter SINAMICS G120 SINAMICS G120D. Function Manual 08/2011 SINAMICS. Answers for industry.

Hyperfast power diode in a SOD59 (2-lead TO-220AC) plastic package.

Ultrafast power diode in a SOD113 (TO-220F) plastic package.

Signature Choral Riser Side Rail

Part Ordering code Type Marking Remarks BAT85S BAT85S-TR or BAT85S-TAP BAT85S Tape and Reel/Ammopack

No. MXDP Indexer Application Software Model: 3G3MX2 CX-Drive Version QUICK START GUIDE

Single Phase Rectifier Bridge, 2 A

MMSZ4681-V to MMSZ4717-V

Broadband LDMOS driver transistor. A 5 W LDMOS power transistor for broadcast and industrial applications in the HF to 2500 MHz band.

Power Rectifier Diodes (T-Modules), 2200 V, 20 A

Instructions for Installation. S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection TABLE OF CONTENTS INTRODUCTION INSTALLATION

BYV34X Product profile. 2. Pinning information. Dual rectifier diode ultrafast. 1.1 General description. 1.2 Features. 1.

Analog Voltage Detector 0-40kV Operating Instructions VDA040CTM

Table 1. Quick reference data Symbol Parameter Conditions Min Typ Max Unit V RRM. half sine wave; T lead 83 C; Fig A

MCL103A / 103B / 103C

Agilent ParBERT Measurement Software. Fast Eye Mask Measurement User Guide

Dual ultrafast power diode in a SOT78 (TO-220AB) plastic package.

Part Ordering code Type Marking Remarks BAS85 BAS85-GS18 or BAS85-GS08 - Tape and Reel

IR Sensor Module for Remote Control Systems

BAS81 / 82 / 83. Small Signal Schottky Diodes. Vishay Semiconductors. Features Integrated protection ring against static discharge

Single Phase Rectifier Bridge, 2 A

Output rectifiers in high-frequency switched-mode power supplies

Dual P-channel intermediate level FET

Qualified for industrial applications according to the relevant tests of JEDEC47/20/22.

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

LOCMOS (Local Oxidation CMOS) to DTL/TTL converter HIGH sink current for driving two TTL loads HIGH-to-LOW level logic conversion

N- and P-Channel 2.5-V (G-S) MOSFET

BTA41-600B 4Q Triac 10 July 2017 Product data sheet

PSMN B. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

SAW components. SAW RF filter Short range devices. RF360 Europe GmbH A Qualcomm TDK Joint Venture. Date: September 15, 2017 Version: 2.

SAW components. SAW RF filter Digital radio. RF360 Europe GmbH A Qualcomm TDK Joint Venture. Date: April 26, 2017 Version: 2.1

VS-T40HF..., VS-T70HF..., VS-T85HF..., VS-T110HF... Series Power Rectifiers Diodes (T-Modules), 40 A to 110 A

Small Signal Fast Switching Diode

Analog Voltage Detector 1-450kV Operating Instructions VDAO450TM. Patent No. 6,275,022

Universal Projector Ceiling Mount Model: DPM-45

Part Ordering code Type Marking Remarks BAT41 BAT41-TR or BAT41-TAP BAT41 Tape and Reel/Ammopack

937CU-AITXF-DC1 Installation Instructions. Transmitter Supply Converter

Complementary 30 V (G-S) MOSFET

Transmissive Optical Sensor with Phototransistor Output

Small Signal Switching Diode

Dual N-Channel 20 V (D-S) MOSFET

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

A1800 ALPHA meter special installation instructions DANGER

Applications & Tools. Sample Blocks for STEP 7 and WinCC flexible - Supplements. WinCC flexible. Application description September 2010

Table 1. Quick reference data Symbol Parameter Conditions Min Typ Max Unit V RRM. half sine wave; T mb 129 C; Fig A

Transcription:

SINAMICS DCM DC converters from 6 kw to 2500 kw for variable-speed direct-current drives Application: Continuous operation in the case of a pulse encoder error Edition 01-12/2010 SINAMICS drives

SINAMICS DCM Application: Continuous operation in the case of a pulse encoder error Compact User Manual Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. Siemens P2010 C98130-A7066-A506-01-7619, 12/2010 1

Table of contents 1 Instructions... 2 2 Field of application... 3 3 Parameter settings... 3 4 Simplified schematic circuit diagram... 5 5 Alignments... 5 1 Instructions Note This application document does not claim to contain all details and versions of units, or to take into account all conceivable operational cases and applications. The standard applications do not represent specific customer solutions, but are only intended to provide support in the implementation of typical applications. The operator is responsible for the correct operation of the products described. Should you require further information or encounter specific problems which have not been handled in enough detail, please contact your local Siemens office. The contents of this application document are not part of an earlier or existing contract, agreement or legal relationship, nor do they change such contracts, agreements or legal relationships. The contract of sale in each case outlines all the obligations of the I DT Drive Technologies Division of Siemens AG. The warranty conditions specified in the contract between the parties are the only warranty conditions accepted by the I DT Drive Technologies Division. Any statements contained herein neither create new warranties nor modify the existing warranty. WARNING The units listed here contain dangerous electric voltages, dangerous rotating machine parts (fans) and control rotating mechanical parts (drives). Failure to follow the relevant Operating Instructions may result in death, serious injury or extensive material damage. Technical Support You can also find help for technical issues through our Technical Support: www.siemens.de/automation/support-request (German) www.siemens.com/automation/support-request (English) Siemens P2010 2 C98130-A7066-A506-01-7619, 12/2010

2 Field of application In some critical processes, the converter equipment cannot be permitted to switch off in the event of a pulse encoder or tacho error. If an error occurs on the actual speed value encoder, the device must remain in operation and automatically switch to the calculation of the actual speed value as a replacement for the actual speed value signal. The calculated actual speed value is based on the measured armature voltage and the motor flow. This application document describes the parameter settings required in order to implement the above application in SINAMICS DCM with the use of free function blocks in the software. If a switch is made from the measured speed to the calculated speed, this is signaled by a HIGH signal on terminal X177.19. Requirement A pulse encoder or analog tacho is required if the system is also to be operated in the field weakening range. This encoder is required in order to record the field characteristic during commissioning and to determine the flow across the field current. (p50051 = 27). Once the field characteristic has been recorded, the speed for both the armature voltage range and the field weakening range can be calculated. 3 Parameter settings The following parameter settings configure the SINAMICS DCM in such a way that in the event of an encoder error, the encoder automatically switches to a calculated actual speed value for closed-loop control. Selection of free function blocks These parameters are also possible in DO1, setting with BOP20. p003 = 3 Expert p009 = 2 Defining the drive type/function module p108[1] = Bit 16 Technology controller Bit 18 Free function blocks Bit 31 PROFINET 00040000 Hex: Bit 18, 80040000 Hex: Bit 18 + Bit 31 p009 = 0 The device is now reinitialized The following parameters are in DO2 p20000[0] = 4 Runtime group 0 is calculated with 4 ms p50083 = 4 Selects the actual speed value source from the free source via p50609 p50609 = 20220 Selects the output of the free changeover switch NSW 0 as the actual value source p20118[0] = 52287 Connects the motor EMF to the X0 divider input DIV 0 p20118[1] = 52290 Connects the motor flow to the X1 divider input DIV 0 p20121 = 0 Runtime group 0 for DIV 0 p20122 = 1000 Run sequence for DIV 0 p20110[0] = 20119[ 0] Connects the output of the DIV 0 to the input X0 of the multiplier MUL 0 p20110[1] = 52401 Connects a fixed signal (p50401) to the multiplier input X1 of MUL 0 p20110[2] = 52001 X2 is 100% for MUL 0 p20110[3] = 52001 X3 is 100% for MUL 0 p20112 = 0 Runtime group 0 for MUL 0 p20113 = 1010 Run sequence for MUL 0 p50401 = xx % Scales the calculated speed in accordance with the maximum speed and the field weakening range (see chapter 5, Alignments), same value for index 0 and index 1 Application: Continuous operation in the case of a pulse encoder error C98130-A7066-A506-01-7619, 12/2010 3

p20128 = 61[0] Connects the measured actual speed value of the pulse encoder to AVA 0 p20131 = 0 Runtime group 0 for absolute value generator AVA 0 p20132 = 1020 Run sequence for AVA 0 p20133 = 20111 Connects the calculated actual speed value to AVA 1 p20136 = 0 Runtime group 0 for absolute value generator AVA 1 p20137 = 1030 Run sequence for AVA 1 p20102[0] = 20129 Output of AVA 0 to X1 of subtracter SUB 0 p20102[1] = 20134 Output of AVA 1 to X2 of subtracter SUB 0 p20104 = 0 Runtime group 0 for SUB 0 p20105 = 1040 Run sequence for SUB 0 p20266 = 20103 Output of SUB 0 to input of limit monitor LVM 0 p20267 = 0.00 LVM 0 interval mean value M p20268 = 0.1 LVM 0 interval limit L p20269 = 0.03 LVM 0 hysteresis HY p20273 = 0 Runtime group 0 for LVM 0 p20274 = 1050 Run sequence for LVM 0 p20158 = 20272 Output of LVM 0 to switch-on delay device PDE 0 p20159 = 10.0 10 ms switch-on delay for PDE 0, set to 10 to 40 ms p20181 = 0 Runtime group 0 for PDE 0 p20162 = 1060 Run sequence for PDE 0 p20218[0] = 61[0] Connects the actual speed value of the pulse encoder to X0 of NSW 0 p20218[1] = 20111 Connects the calculated speed to X1 of NSW 0 p20219 = 20160 Configures r20160 as "Activate changeover switch" p20221 = 0 Runtime group 0 for NSW 0 p20222 = 1070 Run sequence for NSW 0 p2118.0 = 60042 Select tacho fault error message to be hidden p2119.0 = 3 Hide tacho fault error message p50263 = 0 Use flow calculation from field current actual value p50771 = 20160 Message: switch to calculated speed via terminal X177.19, HIGH signal when switch is made to calculated speed BICO r0061[0] r20111 r20220 r52287 r52290 r20160 CO Measured actual speed value of pulse encoder CO Actual speed value calculated CO Actual speed value measured/calculated by the changeover switch for speed control CO Actual EMF value Motor flow PHI BO HIGH for switch to calculated actual speed value Application: Continuous operation in the case of a pulse encoder error 4 C98130-A7066-A506-01-7619, 12/2010

4 Simplified schematic circuit diagram Figure 1 Schematic circuit diagram 5 Alignments Bring the drive into normal operation using the pulse encoder evaluation and p50083 = 2. Perform a current controller optimization sequence with p50051 = 25 and, if necessary, a speed controller optimization sequence with p50051 = 26. For operation with field weakening, also record the field characteristic with p50051 = 27. As soon as the drive is working correctly with the pulse encoder evaluation, make the parameter settings as described in chapter 3. For safety reasons, leave p50083 = 2. Speed calculation Check the output of SUB 0, r20103 and adjust this value to 0.0 using p50401 (measured speed is equal to the calculated speed) In so doing, operate the drive at approx. 50% speed and check r20103 Travel to various speeds and verify that r20103 = 0.0 constantly. Then set p50083 = 4. Tacho break detector If the calculated speed deviates from the calculated speed by more than 10%, the limit monitor LVM 0 responds and its output is HIGH for switching to the calculated speed Interrupt the pulse encoder line to simulate a pulse encoder error and verify that the drive switches to the calculated speed. A minor speed difference occurs during the switchover, but the speed returns to its normal level, with the calculated speed as the actual value. Application: Continuous operation in the case of a pulse encoder error C98130-A7066-A506-01-7619, 12/2010 5

Parameter set 2 (DDS1) We recommend that you switch to parameter set 2 when using the calculated speed and to adjust the speed controller parameters accordingly. p00820[0] = 20160 in the case of calculated speed, switch from DDS0 to DDS1. Copy data set following commissioning: p00819[0] = 0 p00819[1] = 1 p00819[2] = 1 Then set speed controller parameters for DDS1: p50200[1] = 30 p50225[1] = 3 p50226[1] = 0.3 Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG Application: Continuous operation in the case of a pulse encoder error Application: Continuous operation in the case of a pulse encoder error 6 C98130-A7066-A506-01-7619, 12/2010 C98130-A7066-A506-01-7619, 12/2010

Operating Instructions Edition 12/2010 Siemens AG Industry Sector P.O. Box 48 48 90026 NUREMBERG GERMANY Subject to change C98130-A7066-A506-01-7619 Siemens AG 2010 www.siemens.com/automation