FATIGUE INDEPENDENT AMPLITUDE-FREQUENCY CORRELATIONS IN EMG SIGNALS

Similar documents
EMG feature extraction for tolerance of white Gaussian noise

ELECTROMYOGRAPHY UNIT-4

Continuous Wavelet Analysis and Classification of Surface Electromyography Signals

Physiological Signal Processing Primer

Measurement of EMG activity with textile electrodes embedded into clothing

ELECTROMYOGRAPHY SIGNAL ON BICEPS MUSCLE IN TIME DOMAIN ANALYSIS. Hang Tuah Jaya, Durian Tunggal, Melaka, Malaysia

NON INVASIVE TECHNIQUE BASED EVALUATION OF ELECTROMYOGRAM SIGNALS USING STATISTICAL ALGORITHM

Biomechanical Instrumentation Considerations in Data Acquisition ÉCOLE DES SCIENCES DE L ACTIVITÉ PHYSIQUE SCHOOL OF HUMAN KINETICS

Removal of Motion Noise from Surface-electromyography Signal Using Wavelet Adaptive Filter Wang Fei1, a, Qiao Xiao-yan2, b

SOLVING VIBRATIONAL RESONANCE ON A LARGE SLENDER BOAT USING A TUNED MASS DAMPER. A.W. Vredeveldt, TNO, The Netherlands

THE amplitude of the surface EMG is frequently used to

A novel approach to surface electromyography: an exploratory study of electrode-pair selection based on signal characteristics

SURFACE ELECTROMYOGRAPHY: DETECTION AND RECORDING

Optimal Control System Design

EMG. The study of muscle function through the investigation of the electrical signal the muscles produce

EDL Group #3 Final Report - Surface Electromyograph System

System Inputs, Physical Modeling, and Time & Frequency Domains

Compression of surface EMG signals with algebraic code excited linear prediction

LABORATORY 5 v3 OPERATIONAL AMPLIFIER

Continuous Wavelet Transform Analysis of Surface Electromyography for Muscle Fatigue Assessment on the Elbow Joint Motion

Project: Muscle Fighter

Introduction. Chapter Time-Varying Signals

Fatigue Monitoring Compression Sleeve. Group 2: Rohita Mocharla & Sarah Cunningham

CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL

Common-Source Amplifiers

EC209 - Improving Signal-To-Noise Ratio (SNR) for Optimizing Repeatable Auditory Brainstem Responses

Available online at (Elixir International Journal) Control Engineering. Elixir Control Engg. 50 (2012)

2015 HBM ncode Products User Group Meeting

ANALYSIS OF HAND FORCE BY EMG MEASUREMENTS

Performance of Three Electromyogram Decomposition Algorithms as a Function of Signal to Noise Ratio: Assessment with Experimental and Simulated Data

Part 2: Second order systems: cantilever response

Cross-Comparison of Three Electromyogram Decomposition Algorithms Assessed with Simulated and Experimental Data

3.0 Apparatus. 3.1 Excitation System

Why a push-pull amplifier?

USABILITY OF TEXTILE-INTEGRATED ELECTRODES FOR EMG MEASUREMENTS

Science Binder and Science Notebook. Discussions

EMG Electrodes. Fig. 1. System for measuring an electromyogram.

Semiconductor Optoelectronics Prof. M. R. Shenoy Department of Physics Indian Institute of Technology, Delhi

Preliminary study of the vibration displacement measurement by using strain gauge

Scatter Plots, Correlation, and Lines of Best Fit

VIBRATION ANALYZER. Vibration Analyzer VA-12

UNIVERSIDAD TÉCNICA DEL NORTE FACULTAD DE INGENIERÍA EN CIENCIAS APLICADAS CARRERA DE INGENIERÍA EN MECATRÓNICA

Section 3 Correlation and Regression - Worksheet

INDEPENDENT COMPONENT ANALYSIS OF ELECTROMYOGRAPHIC SIGNAL ABSTRACT

FYSP1110/K1 (FYSP110/K1) USE OF AN OSCILLOSCOPE

UNIVERSITY OF CALGARY. Design and Development of a Multichannel Current-EMG System for Coherence Analysis. Daniel Comaduran Marquez A THESIS

BCA 618 Biomechanics. Serdar Arıtan Hacettepe Üniversitesi. Spor Bilimleri Fakültesi. Biyomekanik Araştırma Grubu

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 4. Random Vibration Characteristics. By Tom Irvine

DYNAMIC CHARACTERIZATION OF ORIFICE TYPE AEROSTATIC BEARING

Comparison of Signal Attenuation of Multiple Frequencies Between Passive and Active High-Pass Filters

Practical Impedance Measurement Using SoundCheck

7. Bipolar Junction Transistor

VIBRATION ANALYZER. Vibration Analyzer VA-12

Discrete Fourier Transform (DFT)

The Effect of Combining Stationary Wavelet Transform and Independent Component Analysis in the Multichannel SEMGs Hand Motion Identification System

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

Research Article. ISSN (Print) *Corresponding author Jaydip Desai

FM AND BESSEL ZEROS TUTORIAL QUESTIONS using the WAVE ANALYSER without a WAVE ANALYSER...137

Common-source Amplifiers

Noise Measurements Using a Teledyne LeCroy Oscilloscope

Using the Electromyogram to Anticipate Torques About the Elbow

Response spectrum Time history Power Spectral Density, PSD

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 45, NO. 6, JUNE Hogan and Mann [3], [4] actually present this square root formula as

Sampling and Reconstruction

Technical Aspects of Surface Electromyography for Clinicians

Interference in stimuli employed to assess masking by substitution. Bernt Christian Skottun. Ullevaalsalleen 4C Oslo. Norway

Here I present more details about the methods of the experiments which are. described in the main text, and describe two additional examinations which

Human Reconstruction of Digitized Graphical Signals

Real-world attenuation of muff-type hearing protectors: The effect of spectacles

TECHNICAL APPENDIX FOR: POSSIBLE PARANORMAL COMPONENTS OF ANTICIPATION: PSYCHOPHYSIOLOGICAL EXPLORATIONS

The purpose of this study is to show that this difference is crucial.

Metrics for Assistive Robotics Brain-Computer Interface Evaluation

ELT Receiver Architectures and Signal Processing Fall Mandatory homework exercises

Transmit filter designs for ADSL modems

Operating and Maintenance Instructions. Harvard Isolated Preamplifier

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

Robots Learning from Robots: A proof of Concept Study for Co-Manipulation Tasks. Luka Peternel and Arash Ajoudani Presented by Halishia Chugani

UNIVERSITY OF TECHNOLOGY, JAMAICA SCHOOL OF ENGENEERING. Electrical Engineering Science. Laboratory Manual

Using Rank Order Filters to Decompose the Electromyogram

EMMA Software Quick Start Guide

MEC751 Measurement Lab 2 Instrumented Cantilever Beam

F. N. HOOGE and A. M. H. HOPPENBROUWERS Philips Research Laboratories, N. V. Philips Gloeila~penfabrieken, Eindhoven, Nederland

Low Cost Surface Electromyographic Signal Amplifier Based On Arduino Microcontroller

DESIGN AND IMPLEMENTATION OF EMG TRIGGERED - STIMULATOR TO ACTIVATE THE MUSCLE ACTIVITY OF PARALYZED PATIENTS

Page 21 GRAPHING OBJECTIVES:

Changing the sampling rate

Politecnico di Torino. Porto Institutional Repository

Effect of window length on performance of the elbow-joint angle prediction based on electromyography

Transmit filter designs for ADSL modems

Syllabus Recording Devices

Elizabethtown College Department of Physics and Engineering PHY104. Lab # 9- Oscilloscope and RC Circuit

CHAPTER 14 ALTERNATING VOLTAGES AND CURRENTS

DEFIBRILLATORS often use a small-signal ac measurement

Linear Time-Invariant Systems

New Long Stroke Vibration Shaker Design using Linear Motor Technology

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences

EXPERIMENT 10: SINGLE-TRANSISTOR AMPLIFIERS 11/11/10

A Guide to Reading Transducer Specification Sheets

Self-learning Assistive Exoskeleton with Sliding Mode Admittance Control

CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT

Transcription:

Fatigue independent amplitude-frequency correlations in emg signals. Adam SIEMIEŃSKI 1, Alicja KEBEL 1, Piotr KLAJNER 2 1 Department of Biomechanics, University School of Physical Education in Wrocław 2 Institute of Physics, Wrocław University of Technology FATIGUE INDEPENDENT AMPLITUDE-FREQUENCY CORRELATIONS IN EMG SIGNALS Summary. In order to assess fatigue independent amplitude-frequency correlations in EMG signals we asked nineteen male subjects to perform a series of isometric muscular contractions by extensors of the knee joint. Different amplitudes of the signal were due to randomly varying both the joint moment and the overall amplification factor of the EMG apparatus. Mean and median frequency, RMS and mean absolute value were calculated for every combination of joint moment and amplification at the original sampling rate of 5 khz and at several simulated lower sampling rates. Negative Spearman and Kendall amplitude-frequency correlation coefficients were found, and they were more pronounced at high sampling rates. 1. INTRODUCTION Surface electromyography (SEMG) signals are usually processed by using some data reduction techniques to obtain quantities describing their amplitude and dominating frequency [1]. The four most often used are RMS and MAV (mean absolute value) for amplitude, and median frequency (F med ) and mean frequency (F mean ) for frequency. All four are influenced by both the level of produced muscular force and fatigue. It is also commonly accepted in the literature that fatigue can be deduced from SEMG signal behavior only when simultaneously a drop of F med or F mean and an increase of signal amplitude is observed [2, 3]. In fact, when force produced by a muscle (or moment of force produced at a joint) is kept unchanged with time, fatigue results in a downward shift of the frequency spectrum of the signal and an increase of signal amplitude [2, 3]. That is why the extent or onset of fatigue is typically assessed by simultaneous monitoring of frequency content and amplitude of surface EMG signals collected from engaged muscles and not just the frequency parameters alone [1]. However, such negative amplitude-frequency correlations may occur also at no fatigue due to the varying signal to noise ratio, which could blur the interpretation of EMG signal frequency shifts in terms of fatigue. The objective of this work is therefore to perform a series of EMG measurements under conditions leading to a wide range of signal amplitudes but minimizing the effects of fatigue, and to assess the resulting relationships between amplitude and frequency measures of the EMG signal. 2. MATERIAL AND METHOD Nineteen healthy male volunteers, students of the University School of Physical Education in Wrocław, took part in the experiment. Mean values and standard deviations of their age, body height and body mass are gathered in Table 1.

A. Siemieński, A. Kebel, P. Klajner EMG signals were collected by a pair of surface electrodes placed over the vastus medialis head of the quadriceps muscle, between its motor point and tendon, collinearly with muscle fibers. The signals were processed by the Octopus SEMG device: two stage amplification including a preamplifier (ten times) placed just a few centimeters from the electrode site and the main amplifier (with adjustable amplification) resulting in an overall amplification factor that could be varied between 1 and 2 Table. 1 Characteristics of subjects mean values and standard deviations age [years] (± SD) body height [m] (± SD) body mass [kg] (± SD) 2,29 (±,47) 1,8 (±,4) 74,94 (± 8,1) times. The amplified signals were sampled at a rate of 5 Hz and recorded in digital form on the hard disk of a PC computer. The subjects were asked to assume an upright sitting position on a measuring stand which included a stiff chair with adjustable back support. The position of their right lower limb was adjusted so as to place the knee joint transverse axis as collinearly as possible with the axis of the torque measuring device, and this was done for the knee angle of 9º. The subjects were then asked to try to extend their right limb at the knee joint by pushing against a fixed lever of the torque measuring device placed just above the ankle joint, which resulted in isometric activity of the extensors of the knee joint. After a short warm-up, each subject was first asked to produce his maximum isometric knee extension moment, corresponding to maximum voluntary contraction (MVC) of the quadriceps muscle. The maximum moment of force, produced at MVC, was recorded and later used as reference for all the remaining trials. Then, the main session started which consisted of two-second-long trials realized with visual feedback at 5%, 1%, 2%, 3% and 5%, of MVC, and at the overall amplification factor of the apparatus equal to 1, 2, 5, 1, 2. The sequence of torque levels and amplification factors was random to minimize the effects of fatigue. Also, if a subject reported fatigue at some point of the session a rest break of a few minutes was provided. At the end of the session the knee joint moment at quadriceps MVC was measured again as another test of possible presence of fatigue. For each subject, the experimental session was repeated on the next day. To enhance repeatability of the results, the EMG electrodes were then placed at the sites marked during the first session. Two measures of the amplitude of the EMG signal, RMS and mean absolute value (MAV), and two measures of the dominating signal frequency, the mean frequency (F mean ) and the median frequency (F med ), were calculated for each two-second-long trial. These four quantities were evaluated both for the original signals sampled at the rate of 5 khz and for a number of lower sampling rates simulated by decimating the original data points by integer factors. Spearman and Kendall correlation coefficients were calculated between the measures of amplitude and frequency for some of those sampling rates. 3. RESULTS The measurement results for one subject and one session consist of four numbers representing RMS, MAV, F mean, F med calculated for each (out of five) muscle force level, each (out of five) overall amplification factor and each (out of one hundred: 5Hz, 25Hz, 125Hz,, 5Hz) sampling rate. Out of these four quantities the two amplitude measures behaved quite differently from the frequency measures as the sampling rate increased. The EMG signal amplitude did not change with sampling rate, except for sampling rates below

Fatigue independent amplitude-frequency correlations in emg signals. 25 Hz, where a chaotic behavior could be seen (Fig. 1. brings a representative example of such a behavior for RMS; the other amplitude measure MAV behaved similarly). RMS [mv],18,16,14,12,1,8,6,4,2 amplification 1 5% MVC 1% MVC 2% MVC 35% MVC 5% MVC 1 2 3 4 5 sampling rate [Hz] Fig. 1 Dependence of the RMS value of vastus medialis EMG signal on muscle force level and on sampling rate Contrasting with the above amplitude sampling rate relationship was its counterpart for the two estimates of the dominating signal frequency. There was no chaotic behavior, even at very low sampling rates, in the dependence of the signal median frequency on sampling rate (Fig. 2), and all the five curves corresponding to knee joint extending moments equal to 5%- 5% of MVC showed a consistent growth, which was more pronounced at lower muscle median frequency [Hz] 3 25 2 15 1 5 amplification 1 5% MVC 1% MVC 2% MVC 35% MVC 5% MVC 1 2 3 4 5 sampling rate [Hz] Fig. 2 Dependence of the median frequency of vastus medialis EMG signal on muscle force level and on sampling rate forces. As for the mean frequency of the EMG signal, its dependence on sampling rate was qualitatively similar to that shown by the median frequency but the growth rates were generally higher and not vanishing even at the highest muscle forces investigated, i.e. 5 % MVC (Fig. 3).

A. Siemieński, A. Kebel, P. Klajner mean frequency [Hz] 7 6 5 4 3 2 1 1 2 3 4 5 sampling rate [Hz] Interestingly enough, even though the two frequency measures generally increased as sampling rate increased, their behavior was independent of the muscle force produced until a sampling rate of about 5 Hz was reached. Indeed, in Fig. 2 and Fig. 3 the bunches of curves corresponding to different force levels start as essentially one curve and then split at this frequency, giving rise to a possible relationship between amplitude and frequency measures, the more pronounced the more split the curves are. Above 5 Hz, where the five curves become more and more split, an increase in signal amplitude (i.e. moving vertically across a bunch of curves from the 5% curve to the 5% curve) should result in a decrease of the median or mean frequency. That is why negative correlation between amplitude measures and frequency measures of EMG signal should be expected for sampling rates higher than 5 Hz. Another illustration of this effect is proposed in Fig. 4. where the dependence of the mean amplification 1 5% MVC 1% MVC 2% MVC 35% MVC 5% MVC Fig. 3 Dependence of the mean frequency of vastus medialis EMG signal on muscle force level and on sampling rate Fig. 4 Dependence of the mean frequency of vastus medialis EMG signal on muscle force level and on the overall amplification factor at the highest sampling rate (5kHz) frequency on force level and amplification factor is depicted as a surface graph. The height of the surface graph shows the value of the mean frequency for a given force level and a given amplification factor. At this high sampling rate, 5 khz, the mean frequency of the EMG signal increases rapidly as the force level or the amplification factor (or both) decreases, which, again, can be thought of as a negative amplitude-frequency correlation. In order to assess this correlation the results were grouped into subsets containing data corresponding to a given amplification factor. Within each of those subsets were the results of calculation of the two amplitude measures and the two frequency measures found in all the subjects at five different force levels and at one hundred different sampling rates. All the subsets contained the same amount of data and they differed only by the overall amplification factor of the EMG apparatus. Correlation analysis performed within those subsets of data showed that the amplitude and frequency measures of the EMG signals were not correlated

Fatigue independent amplitude-frequency correlations in emg signals. for low sampling rates but as the sampling rate increased passed the critical value of 5 Hz they became more and more interdependent. mean frequency [Hz] 6 5 4 3 2 amplification 5 sampling rate 25 Spearman: -,93348 Kendall: -,8347 1,1,2,3,4 RMS [mv] Fig. 5 Mean frequency RMS relationship for the overall amplification factor 5 and sampling rate 25Hz all subjects mean frequency [Hz] 9 8 7 6 5 4 3 2 amplification 5 sampling rate 5 Spearman: -,9772 Kendall: -,89532 1,1,2,3,4 RMS [mv] Fig. 6 Mean frequency RMS relationship for the overall amplification factor 5 and sampling rate 5Hz all subjects Two examples illustrating this tendency of amplitude-frequency correlation to become more and more evident as sampling rate increased are shown in Fig. 5. and Fig. 6. In the first of these two figures the interdependence is shown between the mean frequency of the EMG signal and its RMS value, at the overall amplification factor 5 and sampling rate 25 Hz. Most data points lie on or near a hyperbola and Spearman and Kendall correlation coefficients between mean frequency and RMS are -.93348 and -.8347, respectively. For data

A. Siemieński, A. Kebel, P. Klajner corresponding to sampling rate 5 khz, they become -.9772 and -.89532, respectively, and the data points follow a hyperbola even more closely (Fig. 6). 4. CONCLUSIONS Our experimental protocol was designed to produce a wide variety of stationary EMG signals differing as much as possible by their amplitude, and to keep fatigue influence to a minimum. We looked at the behavior of measures of amplitude and measures of dominating frequency of the signals at sampling rates ranging from 5 Hz to 5 khz. Our main conclusions are: amplitude measures such as RMS and MAV do not depend on sampling rate dominating frequency measures increase as sampling rate increases dominating frequency measures do not depend on signal amplitude for sampling rates lower than 5 Hz; for higher sampling rates, the smaller signal amplitude the more steeply the frequency measure increases with sampling rate this gives rise to negative amplitude-frequency correlations that occur at sampling rates higher than 5 Hz and become more pronounced as sampling rate increases such correlations, found here in an experiment designed to minimize fatigue, could shadow the response of amplitude and frequency measures to fatigue and should therefore be taken into account when monitoring the onset and development of fatigue to minimize these effects oversampling of EMG signals should be avoided 5. REFERENCES [1] Farina, D., Merletti, R., 2. Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions. J Electromyogr Kinesiol. 1(5), 337-349. [2] Ferdjallah, M., Wertsch, J.J., Shaker, R., 2. Spectral analysis of surface electromyography (EMG) of upper esophageal sphincter-opening muscles during head lift exercise. J Rehabil Res Dev. 37(3), 335-34. [3] Tarata, M.T., 23. Mechanomyography versus electromyography, in monitoring the muscular fatigue. Biomed Eng Online, 2:3.