INSTALLATION & OPERATION MANUAL

Similar documents
INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

User s Manual Before using the inverter, you need to read and save the safety instructions.

DATASHEET AND OPERATING GUIDE TCS Series Thermistors

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

SK Series Pure Sine Wave Inverter User s Manual

TS-700/1000 INVERTER Instruction Manual

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

M2/M2A AC-DC Power Supply Operator s Manual

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

ARBE-III Instruction Manual

SSR-150xxx-40VL-12P-xC-xxxCS

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Preliminary Data Sheet!

MODEL 3810/2 Line Impedance Stabilization Network

HTA125A/250A. Power Amplifiers. Installation & Use Manual

SSR VL-12P-xC-NCS

EQ-AMP60 60W Mixer Amplifier

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

Rock Sounders. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQRCK400 / AQRCK41

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

Glass Electrode Meter

Switch Mode DC Power Supplies SEC-1212CE SEC-1223CE. Owner's Manual. Please read this manual BEFORE installing your Power Supply.

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

User Manual. Item #37 SA E T ESE INSTRUCTIONS

SEC. Technical Manual. SEC America, LLC. Model SFQ1K400 Frequency Converter

SK Series Pure Sine Wave Inverter. User s Manual

WARNING: Do not work around outlets while the power is on. Do not stick fingers or tools into an electrical box while the power is on.

Broadband Step-Up Transformer. User Manual

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Classic Series Public Address Amplifiers C10 & C20 Models

Opus 21 s80 Integrated Amplifier Owner's Manual

P.O. BOX 1521 POLSON, MT SSR V-12C

Explosion Proof Page/Talk Paging Amplifier

Digital Lighting Systems, Inc.

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

ELECTROSURGICAL UNIT ANALYZER

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Operating Instructions

2015 RIGOL TECHNOLOGIES, INC.

Grid Radar Installation Manual

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

2006 MFJ ENTERPRISES, INC.

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Table of Contents. Safety Notices

Broadband Power Amplifier

Model 7000 Low Noise Differential Preamplifier

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

VOLCANO INGROUND LED LIGHT. Operating Instructions

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Model 3210C. 100 Ampere AC Current Standard. Operating Manual

Distribution Amplifiers 1

Schooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

A Channel Amplifier

KeyPre KP6 - Electronic Instrument Preamplifier

HT Watt 6 Channel Class D amplifier OWNER S MANUAL

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

BC145 SIGNAL ISOLATOR BOARD

Model 9302 Amplifier-Discriminator Operating and Service Manual

Owner s Manual & Safety Instructions

USER'S MANUAL DMR-6700

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

411LA Broadband Power Amplifier

MaxLite Linear Strip ECO Series

Oberebenestrasse Bremgarten Switzerland Tel Fax

Radio Remote(s) (Installation Manual)

7I25 H-BRIDGE MANUAL

PI-10 Broadband Power Indicator

Classic Series Public Address Amplifiers C10 & C20 Models

SureCall TM CM dB Dual Band Universal Inbuilding Repeater

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

INTEGRATED HYBRID TUBE AMPLIFIER VT Model HYBRID TUBE AMPLIFIER

THMS WATT WATT PEAK Other Models

PI-150 Broadband Power Indicator

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Model CC4041. CC Series Amplifier. Installation and Use Manual

24 VDC, 1000 Watt/ 48 VDC, 2000 Watt Rectifier Installation / Operation Manual

Transcription:

INSTALLATION & OPERATION MANUAL IPSi360 Series PURE-SINE INVERTER An ISO9001 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.com

INVERTER IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for the inverter. 2. Do not expose the inverter to rain or snow. 3. Use of an attachment not recommended or sold by the inverter manufacturer may result in a risk of fire, electric shock, or injury to persons. 4. Do not disassemble the inverter; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire. 5. To reduce risk of electric shock, disconnect the inverter from the input power before attempting any maintenance or cleaning. Turning off controls will not reduce this risk. 6. Never place the inverter directly above a battery; gases from the battery will corrode and damage the inverter. 7. Never allow battery acid to drip on the inverter. GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS Inverters should be grounded to reduce risk of electric shock. This inverter is equipped with a chassis grounding stud, and electric receptacles capable of accepting an equipmentgrounding conductor and a grounding plug. Medical Equipment Notice Analytic Systems does not recommend the use of their products in life support applications where failure or malfunction of this product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Analytic Systems does not recommend the use of any of its products in direct patient care. Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), auto-transfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices designated as critical by the U.S. FDA HEAVY DEVICE - The IPSi2400 and IPSi3600 Inverters weigh more than 50 pounds and 70 pounds respectively. Please use appropriate safety measures when lifting or moving these devices. 2

TABLE OF CONTENTS Front Cover, Product Photo and Title Product warnings and advisories Table of Contents Description/Overview of product Main Parts Operation instructions Mounting Instructions Connection instructions Configuration instructions Options Faults Specifications Warranty Copyright Analytic Systems Ware (1993) Ltd. Revised - May 24, 2017 3

Introduction The IPSi360 series of Intelligent Pure Sinewave Inverters are designed specifically for running computers and other sensitive AC loads in rugged mobile and other off grid environments. They produce pure sine wave AC power, exactly the same as a regular AC outlet. The IPSi360 Series Inverter is controlled by a sophisticated Digital Signal Processor (DSP) for optimal control and the most efficient operation possible. The heavy duty Toroidal Power Transformer steps the low voltage AC produced by the Power MosFet Transistors from 110 to 220 VAC at 50 Hz as well as filtering the AC output to reduce or eliminate electrical noise that could interfere with sensitive communications equipment. Using the free to download Power Wizard software, the user can select output frequency, output voltage and low voltage shutdown parameters from any laptop through the standard usb interface. FEATURES Pure Sine Wave 110 VAC / 60 Hz or 220 VAC / 50 Hz fully regulated output, exactly the same as commercial AC. Digitally controlled for precise frequency (± 0.01 Hz) at either 50 or 60 Hz. 360 Watts of output power. State of the art MOSFET technology and sophisticated DSP control for efficient and reliable operation. ON-OFF switch for positive indication of proper operation. Heavy input filtering to shield other devices sharing the same battery. Transformer type output to protect computers and other sensitive equipment from surges and spikes. Low voltage warning and shutdown circuitry to protect the batteries. Over voltage and over temperature warning and shutdown circuitry to protect the inverter. Short circuit protection. LED indicators and a buzzer to bring attention to the cause of the shutdown. 4

Main Parts 1 3 2 4 Front Panel 1. On/Off Power Switch 2. Indicator LEDs 3. Receptacles and/or Hard wired AC output connection 4. USB Port 1 3 2 Rear Panel 1. Thermostatically controlled cooling fan 2. Chassis Grounding Lug 3. DC Input Connections 5

Operation Move the switch to the ON position to to energize the circuitry. The Invert LED will glow to indicate the presence of AC power at the output terminals or receptacle. The LED corresponding to the output frequency will illuminate. Controls and Indicators The IPSi360 Inverter has 8 LED indicators, a microusb port and a On/Off power switch. The microusb port is used to connect the IPSi Inverter to a laptop computer running the PowerWizard software and can be used to update the firmware, to adjust the low and high voltage alarm setpoints, to choose the output frequency (50 or 60 Hz) and to fine tune the output voltage +/- 10% in 1 VAC steps. 1. Low Input Voltage: Blinks Red when the input voltage is near the lower limit for proper operation. Glows Red when the input voltage is too low for proper operation and will be accompanied by the Bypass LED glowing Red and the On/Off switch will not be glowing. Check for the reason for low voltage. Make sure the Low Input threshold is set properly for the battery voltage you are using, around 21V for a 24V battery, around 28V for a 32V battery and around 31V for a 36V battery. 2. High Input Voltage: This LED will blink Red when the input voltage is near the upper limit for proper operation. Glows Red when the input voltage is too high for proper operation and will be accompanied by the Bypass LED glowing Red and the Invert LED turning off. Check for the reason for high voltage. The inverter can be damaged if the input voltage exceeds the maximum rating, and over-voltage damage is not covered under warranty. 3. Over-Temp: Blinks Red if the internal temperature of the inverter is approaching the safe limit. The inverter will reduce its maximum power rating to try to maintain the temperature within safe limits. The LED will glow Red if the inverter is too hot to operate and the Bypass LED will also glow Red and the On/Off switch will stop glowing. Either the cooling fan is defective, or there is not enough air circulation for the inverter. If the fan is running, add extra ventilation. If the fan is NOT running the inverter must be returned for repair. 4. Overload: Blinks Red if the load on the inverter reaches the continuous rating. Solid Red if the load on the inverter reaches the maximum rating. Reduce the load on the inverter. 5. 50 Hz: This LED will be on Green if the inverter is set for 50 Hz operation. 6. 60 Hz: This LED will be on Green if the inverter is set for 60 Hz operation. 7. Bypass: This LED will be on Green if the inverter is in Bypass mode, or on Red if the inverter is in an Alarm condition as described above. 8. Invert: This LED will be on Green when the inverter is in normal operation. 6

Installation MOUNTING Mount the unit in a DRY location. Mount the unit in a ventilated area. Allow at least 1 inch of clearance around the unit for adequate cooling. CAUTION The case of the inverter is connected to AC Ground and AC Neutral to meet regulatory requirements and to reduce the possibility of it generating any radio frequency interference. The case must be bonded appropriately to the grounding system of the vehicle or marine vessel. On a vehicle bond the case to the frame and on a marine vessel bond the case to the hull. A grounding stud is provided on the front of the inverter for this purpose. To ensure proper grounding, check the connection with an ohmmeter. The case is isolated from the DC Input, so the DC power can be on a different ground from the AC output. CAUTION: Do not mount the unit where explosive gases may accumulate as a slight arc may occur when the power leads are connected, and in the unlikely event of a failure, sparks may be generated inside the unit. DISCONNECTION If you disconnect the inverter to remove it for service or storage, turn the power switch on for at least one minute after it has been disconnected to discharge the storage capacitors. Power Wizard Program The PowerWizard Program for laptops can be downloaded from the analyticsystems.com website and will allow programming of: Low Voltage Shutdown parameters to match battery voltage Output Frequency (50 or 60 Hz) Output Voltage over a +/- 10 percent range It will also allow graphing of certain parameters such as Input Voltage, Input Current, Output Voltage and Output Current. 7

Input Connections DC INPUT POWER CONNECTION Prepare a circuit breaker protected power source for the IPSi360 Series Inverter, making sure the breaker is OFF. Connect the input power to the DC IN terminals using AWG8 or 6mm 2 wire. Strip 0.4 inches or 9mm, insert the Positive wire into the Red terminal and the Negative wire into the Black terminal and tighten securely to 16 inch-pounds or 1.8 Newton Meters. CAUTION Do Not Reverse Connect the Input Wires. This will cause serious Damage to the Inverter and will not be covered by Warranty. Turn on the external circuit breaker and then press the ON/OFF switch to turn on the inverter. The ON/OFF switch should illuminate and the Invert LED should come on Green. Once proper operation is confirmed, turn the inverter OFF by pressing the ON/OFF switch again. Output Connections AC OUTPUT CONNECTION The IPSi360 Inverter may be fitted with any one of these receptacles and/or a hard wired AC output connection. The hard wired connection will accommodate wire from AWG24 to AWG10. The wires should be stripped 0.3 inches or 8mm. The terminals are color coded and labelled for Hot, Neutral and Ground. CAUTION Do not apply any external source of AC voltage to these terminals. Damage caused by this action will not be covered under warranty. Hardwired - part code H - NA 110VAC 60HZ NA 220VAC 60HZ - part code U - Worldwide 220VAC 50HZ - part code W - 8

Special Services & Options A C E F I J M U X Z Line AC Detect & Autoswitch UPS COTS MIL461F, MIL810G (MIL Connectors) (Vibration Protection) (Wide Temp {-40 to +55 o C}) (in-house tested and report for each unit- Available as Add on to M Option) European ROHS compliant (Lead Free Manufactured) Electric Fork Lift (Filtering and Surge Suppression) MIL461F (in-house tested and report for each unit- Available as Add-on to M Option) MIL810G (in-house tested and report for each unit- Available as Add-on to M Option) Military Rugged Package (MIL Connectors) (Vibration Protection) (Wide Temp {-40 to +55 o C}) Safety Special Inspection (CSA/UL) Heavy Duty Ruggedization (Vibration Protection) (Wide Temp {-40 to +55 o C}) No Conformal Coating View/download an expanded description of our Special Services & Options online https://www.analyticsystems.com/download 9

Specifications Input Voltages -12-20 -40 Nominal (Vdc) 12 24, 28, 32 or 36 48 or 72 (Rail) Actual (Vdc) 11-16 20-45 40-80 Input Amps (max) 44 24 12 Input Fuse (Internal) 2 x ATC25 1 x ATC25 1 x ATC15 Output Voltages Voltage -110 +/- 2 Vac -220 +/- 4 Vac Output Amps (max) 3A (cont) / 3.6A (peak) 1.5A (cont) / 1.8A (peak) Output Frequency 50.00 or 60.00 Hz ± 0.01 Hz (user selectable) Output Distortion <2% at 360 Watts into resistive load Regulation (Line & Load) < +/- 2.0% Duty Cycle Continuous 100% for 24 hours per day General Efficiency Temp Range Isolation Length Width Height Clearance Material Finish Fastenings Weight Connections > 90% @ maximum output -25 to +40 deg C @ maximum output Input-Output, Input-Case & Output-Case 1500Vdc Input 10.0 in / 25.4 cm 9.1 in / 23.1 cm (including mounting flanges) 3.5 in / 8.8 cm 1 Inch (2.5 cm) all around Marine Grade Aluminum Black Powder Epoxy 18-8 Stainless Steel 12 lbs / 5.4 kg DC In Phoenix VDFK6, 60 Amp, 300V Rating AC Out 1 x NEMA 5-15 15A 120 VAC receptacle or 1 x NEMA 6-20R 20A 250VAC receptacle (220U) or 1 x UNIVERSAL 15A 250VAC receptacle (220W) and/or 1 x Phoenix VDFK4 Hardwire Connection (120H or 220H) * Specifications subjects to change without notice. 10

Limited Warranty 1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the Warrantor ) is warranted to be free from defects in workmanship and materials under normal use and service. 2. This warranty is in effect for 3 years from the date of purchase by the end user. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or a. The date of shipment by Analytic Systems, or b. The date of manufacture coded in the serial number, or c. From a copy of the original purchase receipt showing the date of purchase by the user. 4. In case any part of the equipment proves to be defective, the Purchaser should do the following: a. Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and include the date of purchase, the place of purchase, and the Purchasers name, address and telephone number. b. Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material authorization number (RMA). c. Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., V4G 1K5, Canada. 5. If upon the Warrantor s examination the defect proves to be the result of defective material or workmanship, the equipment will be repaired or replaced at the Warrantor s option without charge, and returned to the Purchaser at the Warrantor s expense by the most economical means. Requests for a different method of return or special handling will incur additional charges and are the responsibility of the Purchaser. 6. Analytic Systems reserves the right to void the warranty if: a. Labels, identification marks or serial numbers are removed or altered in any way. b. Our invoice is unpaid. c. The defect is the result of misuse, neglect, improper installation, environmental conditions, non-authorized repair, alteration or accident. 7. No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so. 8. Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall render this warranty void. 9. There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for equipment specifically stated to be waterproof. 10. No other express warranty is hereby given and there are no warranties that extend beyond those described herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives. 11. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and representatives for injury to any person or persons, or damage to property, or loss of income or profit, or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment, including any possible failure of malfunction of the equipment, or part thereof. 12. The Warrantor assumes no liability for incidental or consequential damages of any kind.

DESIGNED AND MANUFACTURED BY 800-668-3884 604-946-9983 sales@analyticsystems.com Battery Chargers Inverters Power Supplies Voltage Converters www.analyticsystems.com 8128 River Way Delta, BC V4G 1K5 Canada