ifs 150 khz IntraLase Technology

Similar documents
Overview of Commercially Available Femtosecond Lasers in Refractive Surgery

AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.

Laser Glasses

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

HIGH DEFINITION VISION SOLUTIONS THE COMPLETE GUIDE TO LASER VISION CO R R EC T I O N

Dawn of a New Era Modern LASIK Results. Christopher L. Blanton, MD April 28, 2018

SCHWIND AMARIS. We have redefined perfection for you

Trouble Shooting Guide for Ortho-K lenses

LASIK & Refractive Surgery

FEMTO LDV Z8 IMAGE-GUIDED SURGERY ENHANCE YOUR SURGICAL PLANNING

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information

How to get a good centration during SMILE?

Lecture 2 Slit lamp Biomicroscope

MEL 80 Excimer Laser. When you want to see better performance

Unique Aberration-Free IOL: A Vision that Patients

Table of contents. 5 Swiss precision for clear vision. 6 What types of defective eyesight are there? 8 What is refractive eye surgery?

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos Imaging Protocol. Version /14/14

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos 200Tx Imaging Protocol. Version 3.0 9/19/16

H. Lubatschowski T. Ripken, U. Oberheide, C. Ziltz, G. Gerten. Femtosecond Laser Applications in the Huaman Lens

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

FEA of Prosthetic Lens Insertion During Cataract Surgery

The First True Color Confocal Scanner on the Market

DISCO DICING SAW SOP. April 2014 INTRODUCTION

EXPAND YOUR VIEW. SUSTAIN YOUR ACCESS. OASIS IRIS EXPANDER DESIGNED FOR SAFETY & EFFICIENCY. PREMIER EDGE SAFETY SCALPELS SAFETY CRESCENT SCALPEL

CALIBRATION OF MICROSCOPE EYEPIECE GRATICULE

Schwind Amaris 1050 Smart Pulse Technology

SCHWIND eye-tech-solutions International Distributor Meeting Friday, 16th September 2011, 3:00 6:00 p.m. Hotel Sofitel Vienna Stephansdom

Notes: Light and Optics. Reflection. Refraction. Law of Reflection. Light goes straight 12/13/2012

Introducing an enlightened scleral lens designed specifically for regular corneas.

The First True Color Confocal Scanner

Slide 1. Slide 2. Slide 3. Richard Dorer NCLE

Contents. Corneal Markers, Scleral Depressors

Focus on performance. The SCHWIND AMARIS product family TREAT

Impressive Wide Field Image Quality with Small Pupil Size

Using Orthotool Software

High Rise Sit-Stand Desk Converter

Research Article Effect of 60 khz and 150 khz Femtosecond Lasers on Corneal Stromal Bed Surfaces: A Comparative Study

Understanding Optical Specifications

Basic Microscopy. OBJECTIVES After completing this exercise, you should be able to do the following:

Cow Eye Dissection. Online dissection, for kids abstaining:

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

Figure 1. Oil-immersion objectives available for use with the Lionheart FX.

THE ASPHERIC PRELOADED INJECTION

The First True-Color Wide-Field Confocal Scanner

Training Eye Instructions

Optics Laboratory Spring Semester 2017 University of Portland

Our focus is surgical headlights Endovision.com.au

What s New in Ocular Biomechanics?

Termination Procedure

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance

Ayuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

Navigated Laser Therapy. A New Era in Retinal Disease Management

Epson Work Force 1100 CFS System Installation Instructions

The Dysphotopsia Mystery. John J. Bussa, M.D.

Paragon CRT Dual Axis Quick Reference Guide

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

Refractive Power / Corneal Analyzer. OPD-Scan III

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

HYDROPHILIC ACRYLIC ADVANCED POLYMER

Latest Product Releases

HEINE Direct Ophthalmoscopes

Fitting Manual Use with kerasofttraining.com

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

Physics of the Eye *

The Laser Processing of Diamond and Sapphire

Gonioscopy Wet-Lab. About Me. About Me Gonioscopy. Indications for Gonioscopy. Billing Gonioscopy 12/13/2012. Code: 92020

HEINE Direct Ophthalmoscopes

Radial Polarization Converter With LC Driver USER MANUAL

Chapter 23 Study Questions Name: Class:

SPECTRALIS Training Guide

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

Chapter 29/30. Wave Fronts and Rays. Refraction of Sound. Dispersion in a Prism. Index of Refraction. Refraction and Lenses

Welcome to Diamond Vision

Name: Date: Block: Light Unit Study Guide Matching Match the correct definition to each term. 1. Waves

New Materials for Perfect Vision

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

HRK-7000 / HRK-7000A Auto Ref-Keratometer

Sets distance refraction. Moves camera forward / backward. Moves camera up / down. Moves camera left / right. Starts image acquisition (HRT 3 only)

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

OPHTHALMIC SURGICAL MODELS

Simply visionary. Flexible Sensor Endoscopes. for ENDOCAM Logic HD

JET 10" Sliding Dual Bevel Compound Miter Saw

Siesta 100. Training + Certification Guide. Bringing eye care professionals the finest quality, custom GP lens designs.

machines 608 Trestle Point Sanford, FL Phone Fax

Tyler Alignment & Calibration System For the Leksell Stereotactic Frame

ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

case report Scleral lens fit based on OCT data

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

EYE. The eye is an extension of the brain

OpenStax-CNX module: m Vision Correction * OpenStax

Dynamic Ophthalmic Software for today s market. Automated Grading System

Exercise 8: Interference and diffraction

The Human Eye and a Camera 12.1

Physics 319 Laboratory: Optics

Transcription:

How to create a perfect LASIK flap with Intralase Dr Lim Li, FRCS Head(Clinical & Education) Senior Consultant Corneal and External Eye Disease Service Singapore National Eye Centre Financial Interest: Allergan Lim.Li@snec.com.sg ifs 150 khz IntraLase Technology HIGHLIGHTS: Inverted Bevel-In Side Cut Angle Option Elliptical Flap Option Higher Repetition Rate Tighter Spot Separation, Lower Energy Easier Flap Lift Lower Incidence of OBL in Initial Clinical Experience (Chayet) Less OBL observed (less than 10% overall) OBL was soft and typically dissipated immediately upon flap lift Hi-Res Digital Video Microscope with Touch Screen New Contemporary User Interface, Keyboard, and Touch Screen Ergonomically Designed for Maximum Surgeon Comfort New Capabilities for Arcuate Incisions and Corneal Pocket Inlay 1

ifs 150 khz IntraLase Technology Inverted Bevel-In Side Cut Angle: Provides better wound healing for enhanced biomechanical stability of the post LASIK cornea 1,2 Increased flap adhesion post-operatively for optimal wound healing 3x more flap stability for ifs laser (150 side cut) vs MK during flap lift 2 Easier flap lift, replacement, and positioning for optimal flap stability 3 Reduced flap gutter 3 1. Prof J Marshall. Presented ASCRS 2008. 2. Prof M Knorz. Presented ASCRS 2008. 3. P Binder MD, A Chayet MD, Presented ASCRS 2008. 3 Circular vs Elliptical Flaps Circular invades peripheral vital lamellar fibers Elliptical preserves peripheral vital lamellar fibers 2

ifs 150 khz IntraLase Technology Flaps in 10-15 secs Higher Repetition Rate Reduced chance of suction break Improved patient throughput Patient comfort Lower Energy Per Pulse 2.5x faster than current 4 th generation IntraLase FS laser May contribute to less tissue response/inflammation Smoother stromal bed Tighter Spot Separation Easier flap lift with new 2.0 to 8.0 µm line/spot separation range ifs 150 khz IntraLase Technology Video Microscope: Digital High Resolution Video Microscope with Touch Screen Ergonomically Designed for Maximum Surgeon Comfort Display and controls are in front of the surgeon allowing him/her to perform the task comfortably Easily adjustable to personal working distance Dashboard Style Key surgical information (centration rings, procedure time) are conveniently visible in front of the surgeon First femtosecond laser to feature digital hi-res video microscope 6 3

ifs 150 khz IntraLase Technology New GUI features Centration Offset alignment has a real time yellow overlay movement Side Cut Only button is always available ifs 150 khz IntraLase Technology New GUI features Light / Dark eye toggle button: Gamma correction for better visibility of iris Docking indicators: Red Light: End of gantry downward travel Yellow Light: Stop downward Z travel and adjust meniscus by pinching suction ring Green Light: Contact of applanation lens and suction ring 4

Raster Spot/Line Standard Laser Settings FS Starting with a closer spot and line separation allows the user to utilize lower amounts of energy. Raster Energy and Side Cut Energy Set by the Clinical Development Specialist based upon gel findings and surgical results. Pulse to Gas Bubble Expansion 9µ Micro Line separation Adhesions Adjusting a laser s raster spot and line settings will also require an optimization of the raster energy. 8µ 8µ Spot separation Standard Laser Settings Suggested Laser Settings FS Flap Thickness 120 microns Flap Diameter 9.0 mm Side Cut Angle 70 degrees Hinge Position Superior, Nasal and Temporal Hinge Angle 55 degrees The small hinge angle of the IntraLase FS flap allows for full reflection and a larger bed area for excimer treatment. 5

Personalised Laser Settings ifs Inserting the Patient Interface Applanation Cone The base of the applanation cone slides into the loading deck guides located at the bottom of the lens aperture and is secured into place by the locking arm. Also check to see that the z movement of the cone is sufficient for the height of the bed 6

Ensure proper positioning of PI 13 Positioning of patient s nose 14 7

IntraLase Disposable Patient Interface (PI) Suction Ring Assembly The Luer-Lock fitting of the syringe connects to the suction ring tubing. The molded clip on the end of the gripper levers is available for different docking techniques. Docking and Applanation The laser is set up to start its depth calculation at the bottom of the glass applanation lens. Once the cornea is applanated, 120 um below the glass is 120 um in the cornea. During the docking process, it must be ensured that the applanated area (what is seen as the meniscus) is outside of where the laser will treat. Otherwise the depth of the treatment will not be correct. 8

Docking and Applanation Slowly release the plunger allowing the suction ring to affix to the eye. Centration to the pupil is crucial in assuring an accurate treatment. Docking and Applanation FS The Suction Ring (SR) is in the un-clipped position. Drive the gantry downward (z-direction) with the joy stick until the cone comes in contact with the SR, attaining the green light. Align the surgical cone illumination lights centrally over the pupil using the joy stick. Z downward an additional 3-4 seconds. Pinch Suction ring (SR) to allow Meniscus to full (avoid X-Y movement with joystick when applanating) 18 Slowly release pinch to lock SR 9

Normal Intralase Pattern (ifs) ifs flap creation 15 seconds Gas that is created during photodisruption can travel towards the hinge and into the pocket and then into the surrounding, less compressed tissue. If optimal gas flow is changed for any reason, the gas can follow different pathways. Normal Gas Escape It is normal for the built up gas to escape through the side cut in a quick burst before the treatment is complete. Examples of a gas escape or burp. 10

Flap Lift, Excimer Laser Treatment, Flap Placement 21 Intralase flap lifting techniques Single swipe technique 11

Modified 3 swipe flap lift technique 23 THANK YOU Lim.Li@snec.com.sg 12