Product Stewardship for SF 6

Similar documents
IMPACT OF HIGH-VOLTAGE SF 6 CIRCUIT BREAKERS ON GLOBAL WARMING - RELATIVE CONTRIBUTION OF SF 6 LOSSES

General information 1 / 17

SF 6 Characteristics and Re-use Concept

Explanations regarding the new F-gas Regulation (EU) 517/2014 relating to the use of SF 6 in energy transmission and distribution

Reuse of SF 6 Gas in Electrical Power Equipment and Final Disposal. CIGRE Report #117. July 1997

SF6 Gas Management Australia

Communication on Progress to the United Nations Global Compact

G. KOEPPL Koeppl Power Experts Switzerland

Compact Systems for HVDC Applications Dr. Denis Imamovic

Autotransformer Condition Monitoring Systems

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

Service Power Technologies Intelligent service solutions

Tested and ready to use Quality from a single-source

Products for the energy technology of tomorrow. High-voltage bushings for a new energy age

Z January 2017

Technical Series Edition 5

e-dialistic future Science Standards Testing

Economical power supply for high-rise buildings

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

ADVANCING SUPERCONDUCTING LINKS FOR VERY HIGH POWER TRANSMISSION

PGNiG. Code. of Responsible Gas and Oil Production

CP CU1. Coupling unit for line and ground testing

DE-PRIME GLOBAL SERVICES LTD DE-PRIME GLOBAL SERVICES LTD. ADDRESS: 1 Echendu Chinwo Close, Chukwuodara Rumoudara, Port Harcourt, Rivers State.

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

(EC) ), 11(8) 347/ /2009, (EC)

Dietrich Bonmann, ABB Monselice Transformer Days, May 5, 2010 Optimized AC transmission solutions with phase-shifting transformers and shunt reactors

Impact of SF 6 Gas-Filled Switchgear on the Environment

Results of earth fault measurements in an earth fault compensated 110-kV-system. P. Märtel H.-J. Radtke P. Schegner O. Seifert

Transformer Basics AN05-10ST. Application Note. innovation in wire wound magnetic technology. January 09 Rev 1

The actors in the research system are led by the following principles:

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Tripping Relays AR PIN

No matter where you are.

European Utility Week 2014 Amsterdam. Case Study Power Network 2030 Stettlen

INSTRUMENT TRANSFORMERS. Product Spectrum

Draft executive summaries to target groups on industrial energy efficiency and material substitution in carbonintensive

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

penthouse... 8 loft...16 suite...26 studio... 38

The Next Evolution in Dewatering Technology

Chapter 1 The Innovative Bakery Dialogue

Sustainable to the last detail

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Addition of D4, D5 and D6 to SVHC candidate list

Connector Operating Voltage

DWA Set of Rules. Guideline DWA-M 366E. en.dwa.de. Mechanical Dewatering of Sewage Sludge. February Maschinelle Schlammentwässerung

Sulphur Hexafluoride

Medium-voltage in-phase regulator system Energy Management

Testing of 400 kv GIS

Optimizing wind farms

Vacuum Interrupters for Medium Voltage

Onsite Mobile AC High Voltage Test System


Strategic Partnerships in Offshore Project Installations and Wind Farm Operation

CSM High-Voltage Measurement Systems

In-Service Testing and Diagnosis of Gapless Metal Oxide Surge Arresters According to IEC

FACILITY RATINGS METHOD TABLE OF CONTENTS

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

LOC110STR. Single Linear Optocoupler INTEGRATED CIRCUITS DIVISION

INTERNATIONAL STANDARD

HIGH-STRENGTH CONNECTIONS

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Hiding In Plain Sight. How Ultrasonics Can Help You Find the Smallest Bonded Wafer and Device Defects. A Sonix White Paper

Multimeter 560CVD11 Data sheet

European Wind Energy Technology Roadmap

CHEMIE³. The Sustainability Initiative of the German Chemical Industry

Goals, progress and difficulties with regard to the development of German nuclear standards on the example of KTA 2000

Award-winning. MULTI-PURPOSE PAPER FOR MODERN OFFICE MANAGEMENT.

Light measures current

Bolt calculation. Basics Standards Methods Digital tools.

The Future of Vacuum Switchgear

PLA192STR. Single Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Sensor Technology. Applications for medium voltage

LF Conductivity Measuring Probe

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

DESIGN AND TESTING OF HIGH VOLTAGE RF ELECTRONICS

ABB Power Products Service

Experience with Connecting Offshore Wind Farms to the Grid

Publishing date: 23/07/2015 Document title: We appreciate your feedback. Share this document

HIGH TECH FOR HIGH PURITY

Intelligent Surveillance and Management Functions for Airfield Applications Based on Low Cost Magnetic Field Detectors. Publishable Executive Summary

ENERIUM. A powerful solution for energy management and the environment

Installation Manual. Arc Chamber

Power Quality in a 110 kv DSO System Measured by Means of Non- Conventional Instrument Transformers

Optimum dimensioning of a flicker compensator in three-phase electric-arc furnaces supply systems

POWER QUALITY INITIATIVES IN SINGAPORE. S T Chang, K Y Chua, C C Siew and T L Tan. PowerGrid Ltd, Singapore SUMMARY

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

consists of 30 exclusive decors offering the whole spectrum of professional laminate flooring from the old 3 strip favourite to

Partner for FEM Competence in Detail

Continuous Monitoring on the SSE Networks Transmission System

LESJÖFORS FLAT SPRINGS. The Lesjöfors Group also includes.

EPEAT CONFORMITY ASSESSMENT PROTOCOLS 4.7 Corporate Performance

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Latin-American non-state actor dialogue on Article 6 of the Paris Agreement

Ministerial Conference on Nuclear Science and Technology: Addressing Current and Emerging Challenges Vienna, November 2018

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

communication networks Power Line Carrier Communication. Design and Engineering.

This document is a preview generated by EVS

Transcription:

Product Stewardship for SF 6 Michael Pittroff 1, Dr. Hermann Krähling 2, Ewald Preisegger 1 1 Solvay Fluor und Derivate GmbH Hans-Böckler-Allee 20, 30173 Hanover, Germany 2 Solvay Management Support GmbH Environmental Management Support Hans-Böckler-Allee 20, 30173 Hanover, Germany Introduction The manufacturers in the chemicals industry see it as their task to minimize any health, safety and environmental risks which may be related to their products and, at the same time, to meet the needs of their customers and the public for safely usable and environmentally safe products. In the framework of the initiative RESPONSIBLE CARE the concept of PRODUCT STEWARDSHIP has become an important building block towards sustainable development. (1) Product responsibility for SF 6 is concretized in a large number of practical precautions which Solvay Fluor und Derivate - has developed and implemented with - but always for - the users of SF 6. Product Stewardship The following aspects are decisive for the application of product stewardship: - Anchoring in the company - Safety and environmental protection as goals - Communication - Co-operation Anchoring in the company The RESPONSIBLE CARE guidelines of the Solvay Group express the commitment of the top management and employees - to the following principles: - Solvay wants the company's products to be useful to people and the environment. - Solvay wants to account for what happens to the company's products after they have been used. Solvay wants to continuously add to its knowledge about the environment, health and safety and is prepared to engage in open and fair dialogue. The business goals of Solvay Fluor and Derivate also state: - Continue to improve the quality of our products and services. On the basis of our own commitments the anchoring is built into the company which is necessary for the implementation of RESPONSIBLE CARE. Safety and environmental protection The commitments of Solvay Fluor und Derivate GmbH to protect people and the environment are demonstrated in many practical activities. Since the end of the 60's Solvay Fluor und Derivate is a worldwide supplier of SF 6

and, as early as the late 80's, started with the development of the SF 6 ReUse Concept (3). The SF 6 ReUse Concept foccuses on SF6 comming from - electrical switchgears as this is worldwide by far the main application for - SF 6 -. In these electrotechnical applications. - SF 6 can demonstrate its extraordinary characteristics and advantages, such as chemical durability, substantial thermal stability and non-flamable nature. A less favorable feature - of SF 6 is related to its long atmospherique lifetime and comparably high contribution to global warming. As a necessary consequence, handling SF 6 requires a closed cycle minimizing emissions where ever possible and exhausting its reuse potential. The SF 6 ReUse Concept consists of three subsections of the used SF 6 product cycle. The first subsection assumes the on-site reclaiming - of the contaminated goods - involving the use of appropriate equipment. If reclaiming on-site is no longer possible, the second subsection takes effect. In detail, this consists of: - Environmental consulting - Analytical services of used SF 6 - Providing - appropriate packaging and transport of used SF 6 - Reclaiming and reuse Environmental consulting An example of environmental consulting is e.g. the regular Solvay Flour publication "SF 6 Newsletter". The goal of this newsletter is to keep the SF6 community updated about changes in - environmental policy factors for SF 6 -, e.g. due to the Kyoto Protocol and to address related issues of common interest Another part of environmental consulting consists of taking up questions from customers or the public directed to Solvay Fluor und Derivate as an SF 6 producer. Analtical services Enables customers to have analyses carried out by Solvay Fluor und Derivate when they have no analysis facilities or too little experience with used SF 6. The necessary equipment (lecture bottle with adapter) is kept on hand. Providing - appropriate packaging and transport Solvay Fluor und Derivate has a permit for special compressed gas container for transporting used SF 6 from electrical substations. These compressed gas containers are different from the containers for new SF 6 in compliance with IEC 376 due to their thicker walls (taking into account the larger concentrations of corrosive products). The valves of these SF 6 ReUse compressed gas containers (DIN 477 side connector no. 8) are also different than for new manufactured SF 6 (DIN 477 side connector no. 6). Reclaiming and reuse The used SF 6 delivered in the SF 6 ReUse containers is fed into the production process after precleaning. The big advantage of this is that the degradation products of SF 6 are thermocally cracked and transformed into new SF 6. If a residue-free reuse of the used SF 6 is no longer possible, this quality can be disposed of in the framework of the third section of the SF 6 ReUse concept by means of incineration at Solvay. This has been necessary only once now. Communication The communication process must be considered as an important part of the SF 6 product responsibility program. This describes the degree of knowledge of all the parties involved (manufacturers, shipping companies, professional associations and user) including those precautionary measures recommended for SF 6 and

instructions on how to safely handle this product. The success of a good communication process depends on writing complete and meaningful information. Safety specifications sheets and accident reference sheets for SF 6 and used SF 6 are understood as basic. That is why we are only mentioning the folder "Declaration regarding SF6 in electrical switch equipment and switchgears" (4) in this context. This folder was issued by german elecrical associations (VDEW (Vereinigung Deutscher Elektrizitätswerke e.v.) and ZVEI (Zentralverband Elektrotechnik und Electroindustrie)) in cooperation with switchgear manufacturers, power companies and a- SF 6 manufacturer. In this folder all the parties involved voluntarily committed themselves to take all the steps made possible by the current state of the art to avoid SF 6 emissions. Co-operation The development and introduction of the SF 6 ReUse Concept and the above quoted folder "Declaration..." are examples of successful intercompany and cross-industry co-operations. Thanks to a proposal initiated by Solvay Fluor und Derivate in the spirit of the principle of product responsibility, ABB, PreussenElektra, RWE Energie and Siemens, in a joint project, went one step further: to overcome a one-sided view of the environment confined to substance-related global warming potential, an live cycle assessment study was developed. This involved a realistic "power grid for electrical power supply" which was completely analyzed taking into account criteria such as primary energy consumption, space requirements, potential global warming effects, potential contribution to acid rain and potential eutrophic impact. The intention was to create a platform for a documented environmental discussion and, in addition, to illustrate - options for additional ecological optimizing. The live cycle assessment study was carried out in compliance with the requirements contained in the international standard DIN EN ISO 14040 and accompanied and evaluated by an external, independent expert from the TÜV NORD compliance testing agency. The Live Cycle Assessment Study The live cycle assessment study is designed to reflect conditions in Germany; the technologies included correspond to today's state of the art. The study compares different switchgear technologies with and without the use of SF 6 on the level of the switch bays as well as on the level of a real city power supply grid. On the level of switch bays the study examines: conventional weather-protected technology with SF 6 -free equipment weather-protected technology with SF 6 equipment (circuit breakers and transducers) SF 6 -insulated, metal encapsulated switch bays. On the level of the power grids - starting from the given load profile of a German city roughly 40 km² in size with approximately 130,000 inhabitants, a peak load of 120 MW and consumption of 400 GWh in the first year of the study (annual load growth of 1.5 percent) - two alternative supply models are compared: Power is fed into four air-insulated 110/20 kv transforming substations (AIS) at the edge of town with the appropriate amount of space and distributed over the 20 kv network. The 110 kv substations are connected with overhead transmission lines. Power is fed through 110 kv cable into three clearly consumer-proximate SF 6 gas-insulated 110/20 kv transforming substations (GIS) and distributed through the 20 kv grid. In both cases the power is accepted from the superimposed mixed network in a 380/110 kv transformer substation at the edge of town. Both grids are designed so that the supply quality of the consumers is identical; different failure probabilities of the different sorts of operating equipment are taken into account and compensated during the grid layout work. The grid layout is economically optimized in terms of investment volume and costs. The time period of the study corresponds - to treat all the switch bay variations studied adequately. to 30 years of the typical life of air-insulated, high-voltage switchgears. SF 6 -insulated switchgears can generally be used at least an additional 10 years.

UW1 UW2 UW1 UW2 UW4 UW3 UW3 Topology of the grid variants: AIS grid (left) and GIS grid (right). Exemplary for a distribution voltage of 20kV. TS stands for transformer substation. The left exhibit shows that for AIS variants the four air-insulated TS's are located on the edge of town. In the GIS variant shown on the right, the three SF 6 -insulated TS's within the city limits and thus arranged near the consumers. - Thick lines represent 110kV high-voltage, overhead lines (AIS grid) and cable (GIS grid); thin lines are medium-high voltage cable. While the 110 kv overhead lines of the AIS grid (without SF 6 ) surround the city, the 110kV cable of the GIS grid (with SF 6 ) are run into the city, a fact which enables the operator to cut mains leakage. Results of the ecological assessment On the level of switch bays the use of SF 6 technology always provides advantages in four out of five criteria of the live cycle assessment study: for primary energy expenditure, space requirements, acidification and eutrophic potential. Switchgears with substantial rates of utilization and/or low SF 6 dissipation rates also deliver an ecological advantage in terms of potential global warming. On the crucially decisive power grid level the study produces the following picture: The layout of the power grid using GIS technology (with SF 6 ) compared with the layout of the same grid using AIS technology (without SF 6 ) provides a 27 percent reduction in primary energy expenditure, roughly 86 percent reduction in space requirements, a reduction in global warming potential (GWP) by some 21 percent, a decrease in acidification potential (AP) by approximately 19 percent and a drop in europhic potential (NP) by roughly 29 percent. Extensive scenario calculations prove the reliability and applicability of the results. 100 80 60 40 20 0 Energie AIS in [%] GIS in [%] Fläche GWP AP NP The use of GIS switchgears in the power grid studied lowers all the potential environmental impacts studied. The graph shows the relative environment impact potentials in the first year of use of the grid variants (dark bars=ais variants, light bars=gis variants). An increase in the power capacity of the grid by roughly 50 percent (i.e. an improved exploitation of the grid) leads, thanks to SF 6 technology to an additional 5 percent reduction in the parameters primary energy expenditure, global warming potential (GWP), acidification potential and nutrification potential (NP).

The most important reason for these reduction are: due to the substantially better insulation and extinguishing characteristics of SF 6 in comparison to air, stations and equipment in the GIS variant can be made with less material and energy than those in the AIS alternative. Even more decisive is that, due to the compact construction of the GIS components, the 110/20 kv transforming substations can be erected directly at (innercity) load centers. So the energy is delivered to city centers at high voltage with negligible mains leakage and from there through short medium voltage lines to the consumers. Conclusion The use of SF 6 technology leads to clear, ecological advantages in comparison to the use of SF 6 -free switchgears and equipment. This means that SF 6 technology is also sensible for urban power supply from an ecological point of view. This is conditional on the use of GIS stations which guarantee correspondingly low SF 6 emissions and, on the other hand, the vigorous use of SF 6 ReUse concept for a closed SF 6 cycle. The technical and logistical prerequisites for this are in place. It can also quite apparent: an approach to environmental protection which is limited exclusively to global warming potential of one unit by weight of SF 6 is inadequate for the purpose of assessing SF 6 use in high and medium voltage technology. Only an extensive study made of all the relevant environmental criteria in respect to whole power grids with the help of an live cycle assessment study can provides reliable results - and these results are positive for SF 6. Summary PRODUCT STEWARDSHIP as a concept which covers the whole life cycle of products can deliver important contributions to sustainable design development of product systems able to meet future needs: against the backdrop of the goals set and frameworks provided by society and public policy, solutions are achieved by voluntary co-operation among companies -, solutions which will also mean continuous improvements in environmental protection and safety. The "SF 6 ReUse Concept", the "Declaration regarding SF6 in electrical switch equipment and switchgears" and the developed live cycle assessment study "Supplying power using SF 6 technology" demonstrate, how PRODUCT STEWARDSHIP can be translated into concrete actions - and which ecological improvements, based on the use of SF 6 technology, are already possible today and will be possible tomorrow. Indeed evaluation of recent atmospherice measurements indicate a reversed trend in annual emission of SF 6 into the atmosphere by 27 % between 1995-1998. Bibliography (1) Verband der Chemischen Industrie (VCI) Broschüre (Brochure) "Leitfaden Produktverantwortung" (2) Solvay Leitlinien (Guidelines) (3) Solvay Fluor und Derivate "SF 6 stands alone: Harmonising electrical engineering and the environment" (4) VDEW, ZVEI "Erklärung zu SF 6 in elektrischen Schaltgeräten und -anlagen" (5) Live Cycle Assessment Study Electricity supply using SF 6 Technology ABB, PreussenElektra Ntz, RWE Energie, Siemens, Solvay Fluor und Derivate; April 1999 (6) M. Maiss, C.A.M. Brenninmeier, A reversed trend in emissions of SF 6 into the atmosphere, Symposium of Non-CO 2 Greenhouse Gases (NCGG 2) 8-10 September 1999, Netherland