Koganti Sri Lakshmi, G.Sravanthi, L.Ramadevi, Koganti Harish chowdary

Similar documents
A Review Paper on Technical Data of Present HVDC Links in India

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

FACTS devices in Distributed Generation

Modeling and Simulation of STATCOM

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

High Voltage DC Transmission 2

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Performance Improvement of Power System Using Static Synchronous Compensator (STATCOM) Priya Naikwad, Mayuri Kalmegh, Poonam Bhonge

Designing Of Distributed Power-Flow Controller

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

Voltage Control and Power System Stability Enhancement using UPFC

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

Power Quality Improvement in Distribution System Using D-STATCOM

Power Quality enhancement of a distribution line with DSTATCOM

Interline Power Flow Controller: Review Paper

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

Introduction to HVDC Transmission. High Voltage Direct Current (HVDC) Transmission

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A New Control Scheme for Power Quality Improvement with STATCOM

Power Upgrading of Transmission Line by Injecting DC Power in to AC Line with the help of ZIG-ZAG Transformer

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

Improvement in Power Quality of Distribution System Using STATCOM

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 8 Issue 1 APRIL 2014.

Volume I Issue VI 2012 September-2012 ISSN

ELEMENTS OF FACTS CONTROLLERS

SHUNT ACTIVE POWER FILTER

29 Level H- Bridge VSC for HVDC Application

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

Power Quality and the Need for Compensation

Fundamental Concepts of Dynamic Reactive Compensation. Outline

IMPORTANCE OF VSC IN HVDC

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Mitigation of voltage sag by using AC-AC PWM converter Shalini Bajpai Jabalpur Engineering College, M.P., India

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

IJEETC. InternationalJournalof. ElectricalandElectronicEngineering& Telecommunications.

Power Control Scheme of D-Statcom

Mitigation of Fault in the Distribution System by using Flexible Distributed Static Compensator (FD-STATCOM)

The Influence of Thyristor Controlled Phase Shifting Transformer on Balance Fault Analysis

Chapter 10: Compensation of Power Transmission Systems

Investigation of D-Statcom Operation in Electric Distribution System

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

I. INTRODUCTION IJSRST Volume 3 Issue 2 Print ISSN: Online ISSN: X

The unified power quality conditioner: the integration of series and shunt-active filters

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Available ONLINE

Impact of Distributed Generation on Network Voltage Levels

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Control Of Shunt Active Filter Based On Instantaneous Power Theory

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Implementation of UPQC for Voltage Sag Mitigation

Voltage Source Converter Modelling

Comparison and Simulation of Open Loop System and Closed Loop System Based UPFC used for Power Quality Improvement

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Voltage-Current and Harmonic Characteristic Analysis of Different FC-TCR Based SVC

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online):

International Journal of Advance Engineering and Research Development

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Improvement Voltage Sag And Swell Under Various Abnormal Condition Using Series Compensation

Improvement of Rotor Angle Stability and Dynamic Performance of AC/DC Interconnected Transmission System

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

To Study The MATLAB Simulation Of A Single Phase STATCOM And Transmission Line

Improvement of System Reliability & Power Transfer Capability using Distributed Power- Flow Controller (DPFC)

POWER FLOW CONTROL WITH UPFC IN POWER TRANSMISSION SYSTEM

Design and Simulation of Passive Filter

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

SIMULATION RESULTS OF EIGHT BUS SYSTEM USING PUSH-PULL INVERTER BASED STATCOM

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Improvement of Power Quality in PMSG Based Wind Integrated System Using FACTS Controller

Reactive Power and AC Voltage Control of LCC HVDC System with Digitally Tunable Controllable Capacitors

ATC s Mackinac Back-to-Back HVDC Project: Planning and Operation Considerations for Michigan s Eastern Upper and Northern Lower Peninsulas

II. RESEARCH METHODOLOGY

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

AEIJST - July Vol 3 - Issue 7 ISSN A Review of Modular Multilevel Converter based STATCOM Topology

POWЕR QUALITY IMPROVEMENT IN POWЕR SYSTЕM BY USING SVPWM BASED STATIC SYNCHRONOUS SЕRIЕS COMPЕNSATOR

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Improving the Electric Power Quality by UPFC Systems in Electrical Networks

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

Transcription:

International Journal of Scientific & Engineering Research, Volume 6, Issue 2, February-2015 795 Power quality and stability improvement of HVDC transmission System using UPFC for Different uncertainty conditions Koganti Sri Lakshmi, G.Sravanthi, L.Ramadevi, Koganti Harish chowdary Abstract The requirement of delivering economic quality power supply has become a major concern in this developing technology therefore this desired power control at every point of power system is obtained by power controllers like HVDC and FACT devices. Considering the benefits of HVDC like cost, Technical Performance and reliability with full control over the power transmission it is used for long bulk power transmission and asynchronous interconnection. FACTS are power electronic based equipment used to control the power transfer in AC Networks. UPFC is FACT device which can provide power quality and also used for control of active and reactive power flow in transmission line. The main objective of this paper is to improve power transmission capacity and power quality of hvdc transmission using UPFC.The Conventional control scheme cannot control power fluctuations. Here we dealt different types of faults at different locations placing UPFC permanent at receiving end of the line so that the magnitude of fault current and variations of excitation voltage reduced and finally voltage magnitude is improved by UPFC. At the end, Fast Fourier Transformation analysis is carried out to determine total Harmonic Distortion with and without UPFC for different faults. Keywords HVDC converter transformer, UPQC, FACTS, FFT. network. The reactive power supply is done by shunt I. INTRODUCTION capacitors or Static Var Compensators (SVC) installed at the The fast development of power system leads to increase in end terminals. In VSC-HVDC transmission the converters are demand of electricity which leads to different technical insulated gate bipolar transistors with anti parallel diodes problems like power quality and stability. However working on a high frequency PWM switching. As a result of development of SCR, GTO and IGBTS leads to HVDC high frequency harmonics generation by very fast PWM Technology which is used for long distance bulk power switching, filter sizes employed are smaller as compared to transmission, asynchronous interconnection of two different LCC-HVDC. In this respect, VSC-HVDC is more systems and FACTS devices use to solve AC Transmission advantageous than LCC-HVDC. Moreover, unlike classical problems. This paper gives the application of UPFC on HVDC HVDC they do not want reactive power provision for their system for power quality and stability improvement during operation. This avoids additional costs for reactive power different types of faults. supply equipments. [1], [2]. In HVDC through the controlled actions of power Pulse Width Modulation is a modulation technique electronics devices, AC power is converted to DC power and that generates constant magnitude with variable-width pulses made ready for transmission. For applications of Power to obtain desired smooth analogy signal. In PWM switching transmission via cables, bulk power transmission over longdistance, unsynchronized AC-system connection, power scheme a comparison between a fundamental frequency modulating signal and a fixed frequency carrier signal is used system stability improvement and firewall function against to generate firing pulse for VSC converter switching. This instability spread, HVDC transmission is more advantageous comparison produces pulse signals of different width. A than HVAC transmission. desired output parameters from VSC can be generated by There are two technologies of HVDC transmission: varying the magnitude and phase angle of the modulating the LCC-HVDC and VSC-HVDC transmission. The line signal. commutated converter based HVDC is also known as classical FACTS are defined by the IEEE as a power electronic based HVDC. It is currently a widely used DC transmission system. static system that can provide transient and steady state It uses thyristor based converters. Thyristor converters turning stability of the system along with power quality improvement off need the current flow through them to be zero. Hence the [4], [5]. Facts devices are basically of three types: switching frequency is system frequency 50 or 60 Hz. This 1. Series connected: These types of devices are used for active results in production of low order harmonics and a power control in transmission system through impedance requirement of larger filters for filtering out the generated based on conventional or voltage sourced converter using harmonics. Conventional HVDC always consumes reactive GTO (GATE TURN OFF THYRISTER) & IGBT. Some power. This is due to the lagging current which is generated examples of SCR based system are Thyristor- Controlled by delayed firing of the converter switches. This reactive Series Capacitor (TCSC), Static VAR Compensator (SVC) and power demand is a disadvantage to the surrounding AC VSC based devices are SSSC. 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 2, February-2015 796 2. Shunt connected: It is used to control the voltage at the point of PCC by providing leading vars partially meet reactive power demand of the load. There are two types. Conventional system using thyristors like SVC and voltage sourced converter based system using IGBT's and GTO's like STATCOM. 3. Series-shunt connected: It is used to control both active and reactive powers by injecting current and voltage. Some of the examples are UPFC, DPFC and HPFC etc. Fig.2.1.1 schematic diagrams of VSC-HVDC system II. HVDC There are three main HVDC schemes. The selection of each scheme at planning stage depends on the operational requirements, flexibility of demand, reliability issue and cost. The following are the most common HVDC configuration schemes [3]. 1. Mono Polar: In this configuration scheme a single line is used between the converters and either a positive or negative voltage is used for the transmission. The ground or sea or metal can be generally used as return path. Most HVDC installations start as a mono polar transmission, latter developing to the advanced schemes such as bipolar or homopolar schemes. 2. Bi Polar: Here power transmission is carried out using two conductors of opposite polarity. It is a combination of two mono polar systems. Due to this doubling reliability of the system is increased. When one pole of the transmission is removed the other part resumes the normal operation using ground as a return path. 3. Homo Polar: This is a zero distance transmission. The two converters are connected to each other without any DC line. Back-to-back scheme is applied when two transmission systems of different frequency and different control principle are interconnected. The schematic diagrams of HVDC schemes are shown in fig.2.1. Fig.2.1. schematic diagrams of HVDC schemes 2.1 VSC-HVDC System: VSC-HVDC transmission system basically consists of converter valves, phase reactors, filters, power transformers and DC lines. The VSC-HVDC basic system is shown below and brief descriptions and design issues are discussed. Converters: They play the role of converting AC power to DC power or DC power to AC power. The converter valves are built with IGBT power semiconductors. The IGBT valves are arranged in different ways resulting converter topologies. There are different converter topologies. These topologies are broadly classified as two level topology and a multi level topology. The main aim is To minimize the switching losses of the semiconductors inside the VSC. To produce a smooth sinusoidal voltage waveform. The two level converter topology is the simplest circuit configuration that can be used to construct 3-phase VSC. It consists of six valves and generates only two DC voltage values, ±Vdc and even multi level topology can also be applied [6]. Fig.2.1.2 Three phase two level converter topology and produced waveform Phase reactors: They are made up of large inductance with small resistance. They are used to regulate the active and reactive power flow to the ac grid. It is also part of low pass filter that prevent high frequency harmonics from entering the transformer. The inductive reactance between rectifier and AC supply is used to limit fault current and to smoothen voltage. Transformers: Transformers are used for converting the system voltage to a value suitable for the converter. For VSC- HVDC application standard transformers are used. As the filter is located between the transformer and the converter the problem of power loss due to the harmonics in the transformer winding is not a serious problem. Often the transformer is equipped with tap changer on the secondary side to increase the reactive power range. DC Operating Voltage: Higher voltage levels, which usually chosen for large power transfer, require many valves to be put in series, thus higher costs. Thus the choice of the voltage levels mainly touches economical issues. As a result, the 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 2, February-2015 797 selection of operating voltages constitutes one part economic optimization of VSC-HVDC transmission installations. Fundamental frequency component voltage output of the converter can be related to the DC operating voltage by the following equation. Where, UL-L- Line to Line voltage UDC- DC voltage M- Modulation Index DC Capacitor: The capacitor is designed in a way to achieve a small ripple in the DC voltage. The DC capacitor size is characterized by the time constant t defined as a ratio between the DC powers stored at the DC side of the converter to the converter nominal apparent power. In order to obtain a small ripple in the DC voltage, large DC capacitors are required. However, application of large DC capacitors results in slow changes of the DC voltage in response to changes in power exchanged at the DC side of the converter. On the other hand, application of small DC capacitors results in fast response to changes in instantaneous power exchanged but at the expense of larger ripple in the dc voltage. Thus, the total capacitance of the dc capacitors can be approximated by Filters: Filters are utilized for the filtering out of the generated harmonics. Together with the phase reactor they form part of the low pass filter. They are tuned for filtering higher frequency harmonics so that the fundamental frequency component is amplified. It prevents harmonics from entering to the AC system. In the case of VSC-HVDC the harmonic generated are of higher order determined by the frequency modulation ratio (mf). Frequency modulation ratio is the ratio of converter switching frequency (f switch) to the fundamental frequency (f fundamental) given by: From the circuit diagram 2.1.3, the power between the converter reactor and the filter is calculated as: \ Where, Sb- Base apparent power P-Active Power Uf- Filter Bus Voltage IR * - Complex conjugate of current through reactor The active and reactive power between converter and filter bus for a lossless reactor is given by Where, Uf- Filter phase voltage Uc-Converter voltage III. UPFC: One of the FACTS controllers in particular, the Unified Power Flow Controller (UPFC) can control transmission line power flows, voltage magnitudes, phase angles in a power system. Fig.3.1. UPQC configuration VSC based HVDC System: Through controlled PWM pulse signals that applied to converter switches VSC-HVDC is capable of serving the purpose of grid reactive power support and active power transmission. The working of a VSC-HVDC can be given by treating each terminal as a VSC to an AC network through series reactors. Let consider the following one phase equivalent electrical circuit of VSC-HVDC station [8], [9]. Fig.2.1.3 Circuit diagram of VSC-HVDC converter station UPFC consists of two voltage sourced converters. These back-to-back converters, which are converter 1 and converter 2, are operated from a common DC link provided by a DC storage capacitor. This arrangement functions as an ideal ac-to-ac power converter in which real power can freely flow in either direction between the AC terminals of the two converters, and each converter can independently generate or absorb reactive power at its own AC output terminal [7],[10]. Converter 2 provides the main function of the UPFC by injecting a voltage with controllable magnitude and phase angle in series with the line via an insertion transformer. This injected voltage acts essentially as a synchronous AC voltage source. The transmission line current flows through this voltage source resulting in reactive and real power exchange at the AC system. The reactive power exchanged at the AC terminal is generated internally by the converter. The real 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 2, February-2015 798 power exchanged at the AC terminal is converted into DC power which appears at the DC link as a positive or negative real power demand. The basic function of converter 1 is to supply or absorb the real power demanded by converter 2 at the common DC link to support real power exchange resulting from the series voltage injection. This DC link power demand of converter 2 is converted back to AC by converter 1 and coupled to the transmission line bus via a shunt connected transformer. In addition to the real power need of converter 2, converter 1 can also generate or absorb controllable reactive power, if desired, and there by provide independent shunt reactive compensation for the line. It is important to note that whereas there is a closed path for real power negotiated by the action of series voltage injection through converters 1 and 2 back to the line, the corresponding reactive power exchanged is supplied or absorbed locally by converter 2 and therefore does not have to be transmitted by the line. Thus, converter 1 can be operated at a unity power factor or can be controlled to have a reactive power exchange with the line independent of the reactive power exchanged by converter 2. IV. SIMULATION CIRCUITS The test system for the study is an 11 kv, 60 Hz power system consisting of two sources representing two areas connected by an HVDC transmission line of 300 km as shown in Figure 4.1. fault conditions the data has been generated. The simulation configurations for HVDC system with UPQC for RLC load is presented below: Fig.4.3 Simulation model of HVDC without UPFC for RLC load Fig.4.4 Simulation model of HVDC with UPFC for RLC load Fig.4.1 Single-line diagram of HVDC system without UPFC The transmission system is compensated with UPFC at the receiving end of line as shown in Figure4.2. Figure 4.5Simulation model for UPFC with HVDC system Fig.4.2 Single-line diagram of HVDC system with UPFC The simulation model with RLC load has been developed using MATLAB simulink to study the effect of UPFC on the HVDC Transmission system. Based on different 2015 V. RESULTS Based on different fault conditions, i.e. three phase to ground fault, double line to ground fault, single line to ground fault and line to line fault, the voltage and current waveforms for the HVDC system with UPFC and without UPFC are

International Journal of Scientific & Engineering Research, Volume 6, Issue 2, February-2015 799 presented below. 1. Fault analysis for RLC loads: The voltage and current wave forms for RLC loads without and with UPFC and with different faults are shown in fig5.1, fig5.2, fig5.3 and fig 5.4 respectively. Figure 5.1 Voltage and current waveforms for three phase to ground Fault a) Without UPFC b) with UPFC Figure 5.3 Voltage and current waveforms for single line to ground Fault a) Without UPFC b) with UPFC Figure 5.4 Voltage and current waveforms for line to line Fault a) Without UPFC b) with UPFC The FFT analysis has done to calculate the Total Harmonic distortion (THD) for RLC load with and without UPFC and it is shown in Table5.1. The THD is also calculated for RC and RL loads and tabulated in 5.2 and 5.3 respectively. Figure 5.2 Voltage and current waveforms for double line to ground Fault a) Without UPFC b) with UPFC Table 5.1 THD calculation for RLC Load for different faults 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 2, February-2015 800 concluded that UPFC improves the system performance. Type of Fault Without UPFC With UPFC However, it can control the power flow in the transmission line, effectively. With the addition of UPFC, the magnitude of 3 phase to ground fault 8.57% 1.01% fault current reduces and oscillations of excitation voltage also Double line to ground fault 8.85% 1.53% reduce. The total harmonic distortion (THD) is also reduced well below the IEC standards. It is more economical for the Single line to ground fault 8.82% 0.51% HVDC transmission system to transfer more power. UPFC has shown its flexibility promoting a more controllable flow in the Line to line fault 5.75% 1.58% lines. HVDC can be very useful for long transmission lines. It is more recommended in networks or interconnected lines that have high variation of power demands and complicated Table 5.2 THD calculation for RC Load for different faults network connections with different power frequencies. UPFC in general is good for promoting line loadability Type of Fault Without UPFC With UPFC and pool through interconnected network buses more effectively. UPFC can be very useful for deregulated energy 3 phase to ground fault 8.57% 1.04% market as an alternative choice for more power generation to the load area. Double line to ground fault 8.85% 1.56% VII. REFERENCES [1] Hideaki Fujita, Member, IEEE, Yasuhiro Watanabe, and Single line to ground fault 8.82% 0.64% Hirofumi Akagi, Fellow, IEEE, Control and Analysis of a Unified Power Flow Controller IEEE transactions on Line to line fault 5.75% 1.61% power electronics, VOL. 14, NO. 6, NOVEMBER 1999. [2] E.M. Yap, M. Al-Dabbagh, Applications of FACTS Controller for Improving Power Transmission Table 5.3 THD calculation for RL Load for different faults Capability, submitted at the IPEC 2005,IEEE conference, May 2005. Type of Fault Without UPFC With UPFC [3] Lee Wei Sheng, Ahmad Razani and Neelakantan Prabhakaran, SeniorMember, IEEE Control of High Voltage Direct Current (HVDC) Bridges for Power 3 phase to ground fault 8.56% 1.07% Transmission Systems Proceedings of 2010 IEEE Student Conference on Research and Development (SCOReD Double line to ground 2010), 13-14 Dec 2010, Putrajaya, Malaysia. fault 8.86% 1.63% [4] N.G. Hingorani, L. Gyugyi, "Understanding FACTS," New York: IEEE Press, 2000, pp. 2, 29, 135, 300 and 417. 4. Single line to ground Padiyar, HVDC Power Transmission System. New Delhi, fault 8.81% 0.73% India:Wiley Eastern, 1993. [5] J. Arillaga, "Flexible AC Transmission technology, Y. H. Line to line fault 5.76% 1.63% Songs, and A.T. Johns, Ed. UK: Stevenage, Herts IEE., 1999, pp. 99. [6] S.H. Hosseini, A. Sajadi and M.Teimouri, Three phase By comparing the voltage and current waveforms harmonic load flow in an unbalanced AC system. from figure 5.1, figure 5.2, figure 5.3and figure 5.4 using Including HVDC link, Power Electronics and Motion without and with UPFC for Three phase to ground fault, Control Conference, IPEMC 2004. The 4th International, Double line to ground fault, Single line to ground fault and vol. 3, pp. 1726-1730, Aug. 2004. Line to line faults, It can be concluded that the magnitude of [7] D J Hanson, C Horwill, B D Gemmell, D R Monkhouse, fault current and oscillations of excitation voltage has been "STATCOM-Based Reloadable SVC Project in the UK for reduced for different loads with using UPFC for the above National rid", in Proc. 2002 IEEE PES winter power faults. And the total harmonic distortion (THD) has also been meeting, New York city, 7-31 january 2002. Uip.2.pd. reduced below 3%, which are the normal standards as per IEC [8] X.-P. Zhang, "Multiterminal Voltage-Sourced Converter shown in table5.1. Based HVDC Models for Power Flow Analysis", IEEE VI. CONCLUSIONS Transactions on Power Systems, vol. 18, no. 4, 2004, According to the graphs and results it can be pp.1877-1884. 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 2, February-2015 801 [9] F. Schettler, H. Huang, and N. Christl, HVDC Transmission Systems Using Voltage Sourced Converters: Design and Application. Conference Proceedings, IEEE Summer Meeting 2000, Paper No. 2000 SM-260, vol. 2, pp. 716-720. [10] R. S. Tenoso, L.K. Dolan, and S. A. Yari, Flexible AC Transmission systems benefits study, Public Interest Energy Research (PIER), Resource energy, Trn: P600-00- 037, California, Oct 1999. VIII. Biographies Koganti sri lakshmi was born in India in 1983. She received the B.Tech. and M.Tech. Degrees in electrical engineering from the JNTU University, Hyderabad, A.P., India, in 2006 and 2009, respectively, currently, she is working as Assistant Professor in Electrical Engineering department of SNIST. Her current research interests include Renewable energy, HVDC, Smart Grid, power quality, FACTS, and HVAC. G. Sravanthi was born in India in 1987. She received the B.Tech. and M.Tech. Degrees in electrical engineering from the JNTU University, Hyderabad, A.P., India, in 2008 and 2010, respectively, currently, she is working as Assistant Professor in Electrical Engineering department of SNIST. Her current research interests include Renewable energy, power quality, FACTS, Power electronics, Smart Grid. L.Ramadevi was born in India in 1985. She received the B.Tech. Degree in electrical engineering from JNTU University, Hyderabad, A.P., India, in 2006 and M.Tech from Acharya Nagarjuna University, A.P in 2010.Presently she is Persuing Ph.D in Acharya Nagarjuna University, A.P. Currently, she is working as Assistant Professor in Electrical Engineering department of SNIST. Her current research interests include Renewable energy, Optimization techniques, Realiability, Distribution Generation, Smart Grid. Koganti Harish Chowdary was born India in 1990. He received the B.Tech. and M.Tech. Degrees in electrical engineering from the JNTU University, Hyderabad, A.P., India, in 2011 and 2013, respectively. His current research interests include Renewable energy, power quality, FACTS, Smart Grid, HVAC and HVDC. 2015