ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE

Similar documents
ARC 350 HF ELECTROSURGICAL GENERATOR SIMPLY SAFE

EXCELL NHP/T. A new step AheAd to the future ELECTROSURGICAL UNITS FOR MONOPOLAR AND BIPOLAR USE ISO ALSA IT ISO

Electrosurgery. KLS Martin ME 102. The compact Electrosurgical Unit with high Capacity

Electrosurgery. KLS Martin ME MB 2 SAFETY BY EASY USE

surtron.com SURTRON ELECTROSURGICAL units

HF- GENERATORS.

OPERATING MANUAL ELECTROSURGICAL UNIT

ALSATOM SU MPC SU 50 MPC SU 100 MPC SU 140 MPC SU 140/D MPC SU 140/BD MPC

ERBE. ERBOTOM ICC 80 / 50 Instruction manual 08.00

Electrosurgery. maxium INGENUITY IS ALWAYS QUITE SIMPLE

Electrosurgery Units (ESU s) and their variants

ERBE ERBOTOM ICC 300. Instruction manual 08.00

Andy Falconer. Principles of surgical diathermy

OPERATING MANUAL ELECTROSURGICAL UNIT

Application Notes. Electrosurgical Analyzer Primer

ELEKTROTOM 505. Service Manual (E)

Electrosurgery Units (ESU s) and their variants. D. J. McMahon rev cewood

ELECTROSURGICAL GENERATOR USER S GUIDE

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

What tests should be done?

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

USER S GUIDE. User s Guide Bovie IDS-400

BOVIE SURGI-CENTER PRO. Electrosurgical Generator. User's Guide

QA-ES III Electrosurgical Analyzer

Neurosurgery with ultrasonic technology by Söring: fine preparation and effective dissection

User s Guide Aaron 950

OPERATING MANUAL ELECTROSURGICAL UNIT

Surgitron Dual Frequency 4.0 MHz Radiowave Technology

Leksell Neuro Generator

QA-ES III Electrosurgical Analyzer

The TIG AC/DC specialists

Process: DC TIG (GTAW) AC TIG (GTAW) Input Power: 230V, 1-Phase Amperage Range: A Rated Output at40 C (104 F): Maintenance and Repair

Crossfire Footswitch. User Guide

A total solution of precise AC/DC TIG welding and plasma cutting machine

LYRA 501 USER S MANUAL

User s Guide Aaron 940

Meg1 (with Ligasmart)

Operating Lights. marlux with centrixbeam LIGHT OF THE NEXT GENERATION

INSTRUCTIONS ESG-400

METRATESTER 5+ Tester for DIN VDE /6.15

T CaRe ENERGY MADE TO MEASURE

Optimized for perfection.

Technical data ESA614 Electrical Safety Analyzer

TL3000 Ceiling Mount as the Quickest Way to Take High-Precision X-Rays

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

ENS31 Automatic Isolation Unit Product Description

ERCP Papillotomes, balloons, guide wires and baskets.

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

SPECIFICATION NO Model Automatic GTAW Welding System

Tetrix 351 AC/DC AW FW

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

DSP AMPLIFIERS DI

QUICK SETUP GUIDE SECULIFE ESPRO

RF leakage current in electrosurgical units: Influence of the layout in taking measurements

IZT R3600. Product Brochure. Version 1.1

STC-205Di. Quick. Specs. For TIG, Plasma and Stick Welding A combo machine for arc welding and plasma cutting

perioperativecpd.com The basics of diathermy

Moving Test - MT3000

User Manual CTP4/8/16

Spectrum Analyzer R&S FS300

ELEKTROTOM 610. Service Manual. Valid from version 1132

ENS26 Automatic Isolation Unit Product Description

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

DIGEM f 96 x 48 EK. Applications. Description

Miscellaneous Accessories and technical equipment.

J-470 ELECTROSURGE. Radio Frequency Electrosurgery Unit. Operation Instructions

Lincoln Electric EMEAR ASPECT 300. Industrial TIG AC/DC Welder K BK rev02

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator

Digital Indicator DS 96/24

Instruction Manual. (English-English)

Content. User Instruction - Pointoselect digital. Intended use...3 Safe usage of the device...3 Description...4

AIR PLASMA CUTTING C101

BM VET 80, 120, 140, 180 W

Operator s Manual E L E C T R O S U R G I C A L U N I T

ELEKTROTOM 610. Operating Instructions. Valid from version 1130

PULSAR Generator Operator s Manual

Guidebook Endoscopes 2014/2015. New horizons in Endoscopy

ISOMETER IRDH575. Approvals

Electronic Air / Fuel Ratio Control System

Dodecahedron Speaker Set

Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000

Digital Function Generator

SPECIFICATIONS for SPEAKER TEST OSCILLATOR Model OG-484

BUILT IN SAFETY SYSTEM CE APPROVED SMALL AND SMART CALL ME COWELDER 1 A COLLABORATIVE WELDING ROBOT

MIG - TIG - PLASMA - MMA

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator

ARCMASTER. 401MST Multi-Process Inverter Power Source Part No. W

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Rotary Encoder System Compact Model Range

Diamond-Gerjy Proktoskop

Fluke 8808A Digital Multimeter Extended Specifications

maxium electrosurgery unit with maxium Beamer

Modulation Analyzer FMAB

DECLARATION OF CONFORMITY

Fluke 8845A/8846A Digital Multimeters Extended Specifications

DERM 941 DERM 942 High-Frequency Desiccators

COMPACT Diode Laser System (Water-Cooled)

Processes MIG (GMAW) Flux-cored (FCAW) DC stick (SMAW) AC/DC TIG (GTAW) Pulsed TIG (GTAW-P)

Transcription:

BOWA-electronic GmbH & Co. KG Heinrich-Hertz-Strasse 4 10 72810 Gomaringen I Germany Phone +49 (0)7072-6002-0 Fax +49 (0)7072-6002-33 info@bowa-medical.com I bowa-medical.com 10757 4 02/09 Printed in Germany Technische und konstruktive Änderungen vorbehalten / subject to technical and design modification Copyright by BOWA-electronic, Gomaringen, GERMANY ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE

The ARC 200 HF generator provides the most up-to-date technology and technical innovations. The generator settings are already preprogrammed for numerous applications. The software can be updated and upgraded. Extremely fast processors ensure optimally integrated control of the arc. Fast: the ARC CONTROL regulator adjusts the power output to the necessary minimum for tissue variations and changes in cutting area or speed in every case. Safe: the EASY electrode application system monitors the neutral electrode connected to the patient and signals any change in resistance to the user. Flexible: third-party accessories can also be connected to the monopolar and bipolar output using an adapter. As an option, the ARC can also be used for Argon Plasma coagulation. Convenient: some of the 100 locations for storing programs are already pre-programmed. Programs can be shown and hidden as well as named individually. All the main settings / information can be displayed in different languages. 3 Smart: the permanent self-test program checks all safety-related parameters hundreds of times a second and signals any faults. Field of application (extract) General surgery Gynaecology Plastic surgery, oral and maxillofacial surgery Paediatrics ENT Gastroenterology *optional Program Standard, Argon* Gyn-Abdominal Micro Plastic Neuro + Hand Pediatric ENT GastroCut* (Polypectomy, Papillotomy), Argon flex* The specialist: ARC 200

Fast: ARC CONTROL Convenient: 100 programs Safe: EASY patient monitoring Innovative: High-tech concept Smart: continuous self-test Clearly laid out: Settings at a glance Simply safe: all settings at a glance ARC 200: REF 900-200

Specially designed for low power ranges The ARC 200 completes the range of BOWA ARC generators in the low power segment such as are required in numerous special disciplines. Preset programs reduce preparation time for the operation. The team is able to concentrate fully on the patient. GastroCut programs GastroCut Pol (polypectomy) GastroCut Pap (papillotomy) GastroCut ARC 200 has two optional programs for gastroenterological operations: polypectomy and papillotomy. The combination of cutting and coagulation current gives optimum results when using polypectomy loops or papillotomes. Benefit from the optimised GastroCut programs for endoscopy. Like all ARC generators, the unit can optionally be combined with the ARC PLUS argon unit for gastroenterological operations: Argon and Argon-Flex. By using the Argon and Argon-Flex programs, the ARC 200 becomes a powerful workstation for endoscopy and surgery. 5 Special programs for gastroenterology: Polypectomy and papillotomy

From a stand-alone to a complete workstation The Argon Plasma coagulation feature of the ARC PLUS ideally complements the range of ARC HF generators. Argon-assisted HF spray coagulation ignites even in the extremely low power range below 10 watts. The low coagulation depth with only superficial necrosis is outstandingly suitable for coagulation in areas at risk of perforation. Non-contact working prevents electrodes from sticking. Various accessories are available for the different Argon Plasma coagulation programs. Fields of application (extract) Argon General surgery ENT Argon-Flex Gastroscopy Double balloon enteroscopy Bronchoscopy Coloscopy Rectoscopy 7 ARC PLUS with argon assistance

Safety: continuous self-test Operation: simple and safe Ignition: below 10 Watts Endurance: bottle and spare bottle Precise power adjustment for special applications ARC PLUS: REF 900-000 ARC 200: REF 900-200

Technical specification for ARC 200 BOWA ARC 200 units can be used in special areas of HF surgery. ARC generators can be used singly or in combination with the ARC PLUS unit on ceiling supply units or placed on the ARC CART. The ARC 200 has one monopolar and one bipolar output. The unit can be maintained by the hospital technician himself. The fault memories are easy to read. The technician carries out any required software updates by changing a board and subsequently calibrating the unit. If third-party accessories are used, these can be connected with the help of adapters. 9 Maximum cutting power, short-term Number of types of cutting current Number of types of coagulation current Arc control via 32-bit microcontroller (RISC) Number of displays / indicators 5 Number of foot switches 1 Digital set-up Auto Start function for bipolar output 420 watt 20 + 2 with Gastro / Argon option 6 monopolar + 2 with Gastro / Argon option 2 bipolar ARC CONTROL for monopolar cutting Neutral electrode monitoring (EASY) Impedance window for checking the NE Clock frequency Continuous system self-test (ISSys) Unlimited error memory Error documentation display Arc suppression for contact coagulation Continuous Cut Support (CCS) Continuous leakage current monitoring Defibrillator checked 0 300 Ohm 44 khz Simply check: Data & facts

Technical specification for ARC 200 Technical specification for ARC PLUS Compendium: Technical specification for high frequency electrosurgical generator ARC 300e Max. output power for monopolar Cut 200 W Max. output power for monopolar Coag 120 W Max. output power for bipolar Coag 120 W NE safety monitoring (EASY) BOWA ARC PLUS can be combined with all ARC generators for use in all areas of HF surgery coupled by means of a communications interface. The unit can be located both on ceiling supply units and also on a mobile ARC CART. The unit can be maintained by the hospital technician himself. The fault memories are easy to read. The technician can update software by changing a board and subsequently calibrating the unit. 11 Rated frequency 330 khz sinusoidal / 1 MHz pulse Mains connection / max. current consumption Mains fuse Mains frequency Power consumption in standby mode Max. power consumption at max HF power 90 V - 130 V / 6.4 A 198 V - 230 V / 3.2 A 90 V - 130 V / 8 A slow-acting 198 V - 230 V / 4 A slow-acting 50 Hz / 60 Hz 55 VA 750 VA Gas supply Gas type Adjustment range Adjustment range Adjustment range Gas input pressure Argon Purity 4.8 or better, Class 2.1 A 0.1 to 1.0 l/min, adjustment step 0.1 l/min 1.0 to 3.0 l/min, adjustment step 0.2 l/min 3.0 to 9.5 l/min, adjustment step 0.5 l/min between 2.5 and 4.5 bar Equipotential bonding connector Max. gas output pressure 2 bar Storage and transport conditions Temperature -20 C - +50 C Relative humidity 0-75 %, non-condensing Air pressure 500-1600 mbar Operating conditions Temperature 10 C -+40 C Relative humidity 30-75 %, non-condensing Air pressure 700-1600 mbar Protection class to EN 60601-1 I Type according to EN 60601-1 CF Operating mode 10 sec / 30 sec - Two gas connectors, automatic or manual changeover of gas bottles and optical level indicator - PURGE rinsing function with electrodedependent gas pressure control - Safety devices - Continuous flow monitoring, fault indication with display of error number, hose blockage detection, continuous self-test, warning tone, continuous pressure monitoring at distal end - Documentation - Recording of fault conditions and operator errors by storing within the unit. Data recall facility - Connections, communication - Optical interface for communication with ARC 200 Classification according to EC Directive 93/42/EEC Class IIb Mains connection Mains connection Power consumption Mains frequency Equipotential bonding connector 40 VA 50 / 60 Hz Power consumption Mains frequency Equipotential bonding connector Voltage range 40 VA 50 / 60 Hz 85 to 264 V AC Voltage range 85 to 264 V AC Dimensions and weights Dimensions and weights External dimensions (W x H x D) Weight 430 x 150 x 400 mm 10 kg External dimensions (W x H x D) Weight Protection class to EN 60601-1 Type according to EN 60601-1 430 x 94 x 400 mm 7.3 kg I CF in conjunction with ARC generators Classification according to EC Directive 93/42/EEC Class IIa

ARC 200 and ARC PLUS complement one another to form a powerful all-in-one package. 13 The BOWA ARC CART or any ceiling supply unit provides the right footing for the units. The ARC CART can be configured individually, e.g. with shelves, drawer, basket and gas bottle holder. The whole range of foot switches has ergonomically arranged pedals. BOWA provides a complete program of electrosurgical accessories. For even greater potential