NDFG Non-collinear difference frequency generator

Similar documents
PGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

High Energy Non - Collinear OPA

High Power and Energy Femtosecond Lasers

NL300 series. Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES APPLICATIONS NANOSECOND LASERS

High-Power Femtosecond Lasers

pulsecheck The Modular Autocorrelator

Flash-lamp Pumped Q-switched

improved stability (compared with

The All New HarmoniXX Series. Wavelength Conversion for Ultrafast Lasers

Autotracker III. Applications...

Generation of intense few-cycle pulses from the visible to the mid-ir

Mira OPO-X. Fully Automated IR/Visible OPO for femtosecond and picosecond Ti:Sapphire Lasers. Superior Reliability & Performance. Mira OPO-X Features:

Radial Polarization Converter With LC Driver USER MANUAL

APE Autocorrelator Product Family

A CW seeded femtosecond optical parametric amplifier

Laser Beam Analysis Using Image Processing

Kit for building your own THz Time-Domain Spectrometer

User s Guide Modulator Alignment Procedure

The extremely compact laser head is approximately 480 mm long and can

Single pass scheme - simple

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Technische Universität Chemnitz Physikalische Chemie. Laser Safety

3B SCIENTIFIC PHYSICS

Life Science Chapter 2 Study Guide

LASERS. & Protective Glasses. Your guide to Lasers and the Glasses you need to wear for protection.

APPLICATION NOTE. Computer Controlled Variable Attenuator for Lasers. Technology and Applications Center Newport Corporation

3B SCIENTIFIC PHYSICS

Guide to SPEX Optical Spectrometer

GWU versascan. Beta - Barium Borate. Optical Parametric Oscillator. User Manual

User s Guide Modulator Alignment Procedure

SINGLE-MODE LASER DIODES. Chip on Submount, QA-Mount. Laser Diodes

EXPERIMENT 3 THE PHOTOELECTRIC EFFECT

Polarization Experiments Using Jones Calculus

Multi-Wavelength, µm Tunable, Tandem OPO

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

LOS 1 LASER OPTICS SET

Chapter 23 Study Questions Name: Class:

LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points

SECOND HARMONIC GENERATION AND Q-SWITCHING

Period 3 Solutions: Electromagnetic Waves Radiant Energy II

SPRAY DROPLET SIZE MEASUREMENT

Tera-Hz Radiation Source by Deference Frequency Generation (DFG) and TPO with All Solid State Lasers

880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser

Faraday Rotators and Isolators

UNMATCHED OUTPUT POWER AND TUNING RANGE

Supplementary Materials

High energy femtosecond OPA pumped by 1030 nm Nd:KGW laser.

Lithium Triborate (LiB 3 O 5, LBO)

High energy khz Mid-IR tunable PPSLT OPO pumped at 1064 nm

LCLS-II-HE Instrumentation

User s Guide Optical Isolator Alignment Procedure

LASER SAFETY. 5 Dye lasers (3-6) to 1 mj/pulse 20 Hz or 1 khz up to 1

Physics 476LW. Advanced Physics Laboratory - Microwave Optics

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

(A) 2f (B) 2 f (C) f ( D) 2 (E) 2

Pipe Laser Model No Instruction Manual

G. Norris* & G. McConnell

Variable Anamorphic Prism Pair. Manual

The 34th International Physics Olympiad

Absentee layer. A layer of dielectric material, transparent in the transmission region of

APPLICATION NOTE. Computer Controlled Variable Attenuator for Tunable Lasers. Technology and Applications Center Newport Corporation

2. Refraction and Reflection

UV-Vis-NIR Spectrophotometer Quick Start Guide

combustion diagnostics

Delphi. M. W. Roberts. Abstract. An optical communication system is described. The system provides a unique operational capability.

CVI LASER OPTICS ANTIREFLECTION COATINGS

Measuring Kinetics of Luminescence with TDS 744 oscilloscope

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.

Industrial Automation

Chapter Ray and Wave Optics

How to align your laser for two-photon imaging

How-to guide. Working with a pre-assembled THz system

Spider Pulse Characterization

Continuous Wave (CW) Single-Frequency IR Laser NPRO 125/126 Series

Supplementary Figure 1

dnx/dt = -9.3x10-6 / C dny/dt = -13.6x10-6 / C dnz/dt = ( λ)x10-6 / C

Heterodyne Interferometry with a Supercontinuum Local Oscillator. Pavel Gabor Vatican Observatory, 933 N Cherry Ave., Tucson AZ 85721, USA

LASER RADIATION REQUIREMENTS

Optics Laboratory Spring Semester 2017 University of Portland

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

Advanced Laser Personnel Safety System at Jefferson Lab

Instructions for the Experiment

Autocorrelator MODEL AA- 10DM

USING LASER POWER METER

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Lithium Triborate (LiB 3 O 5, LBO) Introductions

TABLE OF CONTENTS. References

Experimental Physics. Experiment C & D: Pulsed Laser & Dye Laser. Course: FY12. Project: The Pulsed Laser. Done by: Wael Al-Assadi & Irvin Mangwiza

Oriel Flood Exposure Sources

JAZ-ALP Adjustable Laser Pointer Operation Manual Document Number 013-RD

Spectroscopy Application: Using Raman Spectroscopy to Detect Art Forgeries Detecting art forgeries using Raman spectroscopy

Pre-Lab 10. Which plan or plans would work? Explain. Which plan is most efficient in regard to light power with the correct polarization? Explain.

4.2W 445nm Laser Diode Component

1170 LIDAR / Atmospheric Sounding Introduction

Lab4 Hanbury Brown and Twiss Setup. Photon Antibunching

Precautions NEVER OPERATE THE DRIVER WITHOUT PROPER COOLING. THE MOUNTING FACE TEMPERATURE MUST NOT EXCEED 60*C.

Dr. Rüdiger Paschotta RP Photonics Consulting GmbH. Competence Area: Fiber Devices

Transcription:

NDFG Non-collinear difference frequency generator Last Rev. 2011.09.21

PREFACE This manual contains user information for the non-collinear deference frequency generator (NDFG). Please, read this part of manual first before attempting to connect and/or operate NDFG. Non-collinear Difference Frequency Generator (NDFG) is used for TOPAS tuning range extension in infrared. This model provides the coverage of 2.6 20 m tuning range when pumped by parametric radiation from the output of TOPAS. The design of Non-collinear Difference Frequency Generator ensures the fixed direction of difference frequency radiation in all the tuning range. Model No. Interaction Wavelength range, nm 8 [U or F] 2WS SHI, SHS, SFI 533 2600 8 [U or F] 3WS SHI, SHS, SFI, SFS 475 2600 8 [U or F] 5WS SHI, SHS, SFI, SFS, FHI, FHS 290 2600 8 [U or F] 6WS SHI, SHS, SFI, SFS, FHI, FHS, SHSFI, SHSFS 240 2600 Models with collinear difference frequency generator Model No. + C1 DFG1 2600 9000 (11000) Model No. + C2 DFG2 4000 15000 (20000) Model No. + C3 DFG1, DFG2 2600 15000 (20000) Models with non-collinear difference frequency generator Model No. + N1 DFG1 2600 9000 (11000) Model No. + N2 DFG2 4000 15000 (20000) Model No. + N3 DFG1, DFG2 2600 15000 (20000) In model number first letters represents the product type: TC TOPAS-C, TT TOPAS-Twins, T TOPAS-800ps, TP TOPAS-Prime. F femtosecond pulses 60-200fs, U Ultrashort femtosecond pulses 20-60fs. Light Conversion 2

DIMENSIONS Figure 1. NDFG housing Dimensions and positions of input and output ports. Light Conversion 3

TABLE OF CONTENTS PREFACE... 2 DIMENSIONS... 3 TABLE OF CONTENTS... 4 LIST OF FIGURES... 5 1. SAFETY PRECAUTIONS... 6 2. POSITIONING AND CONNECTION OF NDFG... 8 2.1. POSITIONING SCHEMES... 8 2.2. CONNECTION OF NDFG TO TOPAS... 9 3. DESCRIPTION OF OPERATION OF NDFG... 11 3.1. PRINCIPLE OF OPERATION... 11 FIGURE 11. EXAMPLE OF HOW ANGLE BETWEEN SIGNAL AND IDLER DEPENDS ON DF WAVELENGTH.. 12 OPTICAL LAYOUT OF NDFG... 13 4. PREPARING NDFG FOR USE... 15 4.1. LOADING THE NDFG TUNING CURVE... 15 4.2. SETTING UP THE NDFG CONFIGURATION... 15 5. TROUBLESHOOTING... 16 SYMPTOM: THE DIFFERENCE FREQUENCY ENERGY IS TOO LOW.... 16 SYMPTOM: THE BEAMS (AT THE OUTPUT OF NDFG) ARE NOT IN VERTICAL LINE... 16 SYMPTOM: WAVELENGTH OF DIFFERENCE FREQUENCY IS SHIFTED... 16 RECOMMENDATION FOR DETECTION OF DF BEAM... 16 AFFIX 1... 17 List of nonlinear crystals for NDFG... 17 Light Conversion 4

LIST OF FIGURES Figure 1. NDFG housing Dimensions and positions of input and output ports.... 3 Figure 2. Location of the labels on NDFG. Label description is given in Table 1.... 7 Figure 3. NDFG shifted sideward from output of TOPAS; top view.... 8 Figure 4. NDFG shifted sideward from output of TOPAS and external Mixer1 is connected to TOPAS; top view.... 8 Figure 5. NDFG shifted sideward from output of TOPAS and external Mixers is connected to TOPAS; top view.... 9 Figure 6. Connectors of NDFG (in red rectangular): (a) NDFG front panel with IDC connector,... 9 Figure 7. Principle interconnection scheme for TOPAS system.... 10 Figure 8. Difference frequency crystal.... 11 Figure 9. Tuning curves for non-collinear difference frequency generation in AgGaS 2 for three values of intersection angle of pump beams: a) ratio of difference frequency and signal wavelength, b) idler incidence angle versus DF wavelength, c) signal and idler intersection angle versus DF wavelength. Crystal cut angle deg.... 11 Figure 10. Tuning curves for non-collinear difference frequency generation in GaSe for three values of intersection angle of pump beams: a) ratio of difference frequency and signal wavelength, b) idler incidence angle versus DF wavelength, c) signal and idler intersection angle versus DF wavelength. Crystal cut angle deg.... 12 Figure 11. Example of how angle between Signal and Idler depends on DF wavelength.... 12 Figure 12. Beam routing of parametric signal.... 13 Figure 13. Beam path in NDFG.... 14 Figure 14. The Position of the beams in space at the output of NDFG. Invisible DF beam in the top is at the fixed height. Signal height changes depending on the output wavelength.... 14 Figure 15. Load/Unload tuning curves menu... 15 Light Conversion 5

Safety precautions 1. SAFETY PRECAUTIONS The TOPAS system (optical parametric amplifier with non-collinear difference frequency generator) emits coherent electromagnetic radiation in visible and invisible to human eye (infrared and ultraviolet) spectral regions. The device cannot generate output energy without being pumped by a laser. However, the TOPAS system, when coupled with an appropriate pump laser, comprises a Class 4 laser system. The system users are responsible for taking appropriate safety training and ensuring compliance with local codes and regulations, which apply to Class 4 laser systems. It is imperative that users learn all safety information, which is provided in the pump laser s manuals. All further information provided in this section should be considered as supplementary to the information provided there. The greatest concern when using TOPAS system is eye safety. Direct, reflected or scattered radiation present in/emitted from TOPAS system can cause permanent eye damage and possible blindness. Apart from that, the radiation present in/emitted from TOPAS system can cause skin or clothing burn, or ignite fire after hitting flammable substances even at some distance. The beams present in/emitted from TOPAS system are powerful enough to damage sensitive optical equipment such as video cameras and photodiodes. Because of these reasons the user is advised to follow safety measures listed below: 1. The TOPAS system together with its pump laser and supplementary equipment must be located in a locked area with access to authorized personnel only. This area must be marked by well defined warning signs, and be off limits to people not allowed to be there. 2. TOPAS system together with its pump laser must only be operated by qualified personnel who have received appropriate safety training and system s user training. 3. Use protective eyewear at all times when aligning and operating the TOPAS system. Make sure that your protective glasses are rated to protect against all the multiple wavelengths emitted at TOPAS system output! Remember that the TOPAS system output wavelength can be automatically and continuously tuned in broad wavelength range, from ultraviolet to infrared (exact wavelength range of your system depends on the model). A few pairs of safety glasses may be needed to cover all the output range. Remember that parametric radiation and its harmonics can be beyond the range of human vision. Remember that the protective glasses, while protecting your eyes, also prevent from seeing the beams. Therefore be cautious even when using safety glasses. 4. Do not work with TOPAS system cover opened unless absolutely necessary. Intense light beams, their specular and scattered reflections can be emitted from various parts of TOPAS system when the cover is opened! 5. Maintain TOPAS system and all connected experimental setups considerably bellow eye level to prevent accidental beam encounter. Keep the beams enclosed where possible. Always be aware and inform other users of all the open air beam paths. 6. Avoid wearing watches or other objects that may reflect the beams. 7. Never look directly into any beam exit apertures or scattered beams from reflective surfaces including such surfaces as business cards. 8. Always keep the TOPAS system powered for the safety beam shutter to operate correctly. 9. Observe all other safety precautions given in the user s manual. Maximum accessible radiation level from the TOPAS system: The TOPAS system, depending on the model, produces visible and invisible radiation continuously tunable in the maximum wavelength range of 185 to 22000 nm with a maximum of 50W of average pump power, and 5 mj maximum energy per 20 to 300 femtosecond pulse. 10. Be very careful when aligning and working with the TOPAS system! Light Conversion 6

Safety precautions Description of all NDFG labels is presented in the table and picture below. Table 1. Description of NDFG labels No Label Description 1. Aperture label is located next to the output aperture of the NDFG and points to it. 2. Label for defeatably interlocked housing is located on the removable part of the protective housing. Figure 2. Location of the labels on NDFG. Label description is given in Table 1. Light Conversion 7

Positioning and connection 2. POSITIONING AND CONNECTION OF NDFG 2.1. Positioning schemes The positioning TOPAS and NDFG on the optical depends on the configuration. All standard positioning schemes is presented below. In these positioning schemes NDFG is shifted sideward from output of TOPAS and beam routing units are used to route the parametric signal in to NDFG. Beam routing mirrors are with metallic coating. First case of positioning is when only NDFG (without external Mixers) is connected to TOPAS is presented in Figure 3. Figure 3. NDFG shifted sideward from output of TOPAS; top view. In the second case external Mixer1 and NDFG is connected to TOPAS. Example of such scheme is presented in Figure 4. Figure 4. NDFG shifted sideward from output of TOPAS and external Mixer1 is connected to TOPAS; top view. Light Conversion 8

Positioning and connection To connect more external Mixers one can use such positioning scheme, see Figure 5. Figure 5. NDFG shifted sideward from output of TOPAS and external Mixers is connected to TOPAS; top view. 2.2. Connection of NDFG to TOPAS TOPAS and NDFG are connected together using the cable with IDC connectors. The IDC connectors are on the back panel of TOPAS and on the front panel of NDFG, see Figure 6 (a) and (b). Connectors for external mixers are on the back panel of NDFG, see Figure 6 (c). (a) (b) (c) Figure 6. Connectors of NDFG (in red rectangular): (a) NDFG front panel with IDC connector, (b) NDFG back panel with AMP connectors for external mixers (c) TOPAS back panel with IDC connector. Light Conversion 9

Positioning and connection The principle interconnection scheme for TOPAS system: TOPAS, NDFG and external Mixers are presented in Figure 7. Figure 7. Principle interconnection scheme for TOPAS system. Warning! Do not attempt to connect or disconnect IDC cable or external mixers, when the TOPAS is powered on. Before connecting and disconnecting any cable turn off TOPAS controlled board and disconnect the power supply cable. Light Conversion 10

Description of operation of NDFG 3. DESCRIPTION OF OPERATION OF NDFG 3.1. Principle of operation Nonlinear crystal #8 (AgGaS 2 of I type phase matching) or #9 (GaSe of I type phase matching are used for non-collinear difference frequency generation (NDFG) when mixing signal and idler waves from the output of TOPAS. The diagram of non-collinear interaction is presented in Figure 8. Figure 8. Difference frequency crystal. Tuning of difference frequency pulse wavelength is accomplished rotating nonlinear crystal in vertical plane and changing the angle I - S between incoming beams. The angle I-DF between DF and Idler beam is kept fixed in all tuning range. The conversion efficiency is optimized adjusting time delay between interacting pulses (rotating time delay crystal). In Figure 9 and Figure 10 the examples of tuning curves for difference frequency generator with AgGaS 2 and GaSe respectively are presented. (a) (b) (c) Figure 9. Tuning curves for non-collinear difference frequency generation in AgGaS 2 for three values of intersection angle of pump beams: a) ratio of difference frequency and signal wavelength, b) idler incidence angle versus DF wavelength, c) signal and idler intersection angle versus DF wavelength. Crystal cut angle deg. Light Conversion 11

Description of operation of NDFG (a) (b) (c) Figure 10. Tuning curves for non-collinear difference frequency generation in GaSe for three values of intersection angle of pump beams: a) ratio of difference frequency and signal wavelength, b) idler incidence angle versus DF wavelength, c) signal and idler intersection angle versus DF wavelength. Crystal cut angle deg. To keep the same direction of the difference frequency beam (when wavelength of DF is changing) the angle between Signal and Idler beams also changes, see Figure 11. Figure 11. Example of how angle between Signal and Idler depends on DF wavelength. Light Conversion 12

Description of operation of NDFG Optical layout of NDFG To route the beam (Signal and Idler) from TOPAS in to NDFG to metallic mirrors are used BR(Au) and BR-F(Au), see Figure 12. The mirror BR-F(Au) is so called Flipper (detachable mirror), one can detach it if NDFG is not used. Figure 12. Beam routing of parametric signal. Warning! Do not open dichroic mirror DM3(M12) (on TOPAS back panel) when signal is used for NDFG. The fresh pump can damage the metallic mirrors BR(Au) and BR-F(Au) and nonlinear crystals of DFG. Parametric beam (Signal and Idler) path is presented in Figure 13. The Signal and Idler is separated in dichroic mirror DM1. Signal beam is reflected to metallic mirror SM1, then to SM2 and to the dichroic mirror DM2. Idler beam is transmitted through DM1 and it is forwarded to the mirrors IM1 and IM2. From the mirror IM2 the beam is reflected to the mirror DM2. Then the idler beam is transmitted through DM2 into the NDFG Crystal stage and this stage in WinTOPAS program menu is named NDFG Crystal. Light Conversion 13

Description of operation of NDFG Figure 13. Beam path in NDFG. The mirror IM2 is placed on the translation stage to overlap signal and idler pulses in time. The mirror IM2 is named as NDFG Delay in WinTopas program menu. The dichroic mirror DM2 is fixed on the motorized stage which rotates it in a vertical plane to change the vertical reflection angle of the signal beam. The DM2 is named as NDFG Mirror in WinTopas program menu. By changing the vertical angle of the mirror DM2 it is possible to keep the DF beam at the same height at the output of NDFG (Figure 14). Figure 14. The Position of the beams in space at the output of NDFG. Invisible DF beam in the top is at the fixed height. Signal height changes depending on the output wavelength. The DF beam is generated in the NDFG Crystal stage. From the NDFG Crystal DF, residual signal and idler beams are forwarded to the output port. All three beams travel at the different height (Figure 14). The Residual signal and idler beams should be blocked by the user outside the NDFG. For detection of DF beam it is recommended to use mid-infrared radiation sensitive material (liquid crystal sheet). The polarization of DF beam is horizontal. Light Conversion 14

Preparing NDFG for use 4. PREPARING NDFG FOR USE 4.1. Loading the NDFG tuning curve TOPAS system motorized stages are controlled through WinTOPAS program. All motorized stages are included in appropriate tuning curves, for example the OPA tuning curve consists of such motors: Crystal 1, Delay 1, Crystal 2 and Delay 2. The OPA tuning curve is named OPA_06001.crv. The interactions SHS, SFS, SFS, SFI are generated in Mixer1 and tuning curve for Mixer1 is named Mixer1_06001.crv. The tuning curve of Mixer2 (interactions: FHS, FHI, SHSFS and SHSFI) is named Mixer2_06001.crv. For more information about tuning curves and WinTOPAS program read WinTOPAS user manual. NDFG motorized stages (NDFG Crystal, NDFG Mirror and NDFG Delay) are included in NDFG tuning curve. The tuning curve for NDFG is named NDFG_06001.crv. Sometimes tuning curves for Mixer1 and NDFG are in different files so the user has to unload the tuning curve of Mixer1 ( Mixer1_06001.crv ) and to load the proper tuning for NDFG ( NDFG_06001.crv ) see Figure 15. Figure 15. Load/Unload tuning curves menu 4.2. Setting up the NDFG configuration The following steps have to be taken for setting up the NDFG configuration: 1. Close the shutter of TOPAS. 2. Check if DM3(M12) mirror is closed (TOPAS back panel). 3. Put BR-F(Au) mirror on magnetic pad to reflect the Signal and Idler to NDFG, see Figure 12. 4. Check the positions of DM1 and IM1 mirror places; they have to be in beam path (see Figure 13). 5. Check if the beam is centered on iris apertures A0 and A1. 6. Open the shutter of TOPAS. Light Conversion 15

Troubleshooting 5. TROUBLESHOOTING If troubleshooting and corrective procedures in this chapter do not solve the problem, contact your Light Conversion representative before taking further action. Symptom: The difference frequency energy is too low. Possible Cause: Difference frequency wavelength can be in absorption range of gases in air. The output energy (Signal + Idler) from TOPAS is too low The Signal and Idler beams are not collinear Beams are not centered on the iris apertures inside the NDFG The positions of NDFG motors are misaligned Optical path between Signal and Idler (inside NDFG) is different Corrective Action: Purge the environment with nitrogen gas. Try to reset all motors of TOPAS. Check if beams are centered on iris apertures inside the TOPAS. For more information refer to TOPAS manual. Adjust the input beam direction using the beam routing mirrors before TOPAS. Inspect the collinearity in longest distance as it is possible to do (recommended distance is 5-10 meters away from TOPAS). Adjust the beam direction with routing mirrors (BR-F(Au) and BR(Au)). Try to reset all motors of NDFG. Optimize the delay with motor NDFG Delay in WinTOPAS software. Symptom: The beams (at the output of NDFG) are not in vertical line Possible Cause: The Signal and Idler beams are not collinear Corrective Action: Adjust the input beam direction using the beam routing mirrors before TOPAS. Inspect the collinearity in longest distance as it possible to (recommended distance is 5-10 meters away from TOPAS). Slightly adjust the DM2 mirror in horizontal plane. Symptom: Wavelength of difference frequency is shifted Possible Cause: The wavelength of Signal and Idler can be shifted Corrective Action: Try entering different wavelength of NDFG Recommendation for detection of DF beam For detection of invisible beams one can use liquid crystal sheets, for more information refer to Chapter 2.2 on page 12. Light Conversion 16

Affix 1 AFFIX 1 List of nonlinear crystals for NDFG Crystal Crystal numbe r #8 AgGaS 2 = 39 #9 GaSe = 0 Nonlinear Process Output wavelengths and polarization Crystal placement Crystal rotation axis DFG1 2600 11000 V NDFG H DFG2 5000 20000 V NDFG H S signal pulse generation I idler pulse generation DFG difference frequency generation when mixing signal and idler pulses. Light Conversion 17