Film capacitors Power Factor Correction

Similar documents
Film Capacitors Power Factor Correction

Film capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Installation and maintenance instructions for capacitor contactors

Film Capacitors Power Factor Correction

Film Capacitors AC Capacitors

Surge arrester. 2-electrode arrester B88069X9761B201 H25-E70X

Film Capacitors AC Capacitors

Ferrites and accessories

Film Capacitors AC Capacitors

Surge arrester. 2-electrode arrester B88069X3433B251 V87A-A600XP1

Film capacitors Power Factor Correction

Film Capacitors AC Capacitors

Switching spark gap. SSG without lead wires B88069X7391T602 FS08HF1BSMD

Inductors. VHF chokes B82114 MAG IN PD

Switching spark gap. SSG with lead wires B88069X3790T502 FS08X-1JG

Film Capacitors AC Capacitors

PTC thermistors. Thermal management in LED driver circuits, EIA size Date: December 2007

Film Capacitors AC Capacitors

Switching spark gap. SSG with lead wires B88069X3440S102

EMC filters. Date: November 2012

B1653 B39122-B1653-B510 December 18,

2 line filters for converters and power electronics

Surge arrester. 3-electrode arrester B88069X9701T702 T30-A250XFSMD

B3520 B39162B3520U410 February 22,

SHDSL interface transformer

B3404 B39232-B3404-U410 April 08,

PPD AB PD / PPD AB PM

SMT Power Inductors. ERU 20, helically wound B82559*A020

Surge arrester. 2-electrode arrester. B88069X2500xxxx a) EM2500XS

B9417 B39162B9417K610 January 23,

B9513 B39202B9513L310 May 27,

B5139 B39262B5139U410 June 18,

R880 B39431R 880H210 February 04,

B5114 B39781B5114U410 Mar 19,

Surge arrester. 2-electrode arrester B88069X1620T602 A80-A230XSMD

B5235 B39141B5235Z810 Sep 23,

Transformers. DC/DC converters E 6.3. Series/Type: B78304B*A003 Date: October 2012

Inductors. RF chokes, LBC series, mm. Date: June 2011 Version:

Power Quality Solutions

B9474 B39162B9474P810 October 19,

PPD AB PD / PPD AB PM

B9508 B39202B9508L310 February 18,

Power Factor Correction

Data and signal line chokes

B9898 B39272B9898P810 May 15,

B88069X1630T602 A80-C90XSMD PPD AB PD / PPD AB PM

SMT power inductors. Size 12.5 x 12.5 x 8.5 (mm) B82477R4

B9522 B39182B9522P810 December, 12,

SMT power inductors. Size (mm) Date: March 2008

B8313 B39162B8313P810 February 12,

SMT current sense transformers. EE 5.0 core. Series/Type: B82801B Date: December 2012

B8831 B39242B8831P810 August 18,

B3725 B39871B3725U410 May 16,

B3710 B39431B3710U410 December 17,

SMT power inductors. Size (mm) Date: March 2008

B9430 B39252B9430M410. September 02,

SMT Push-Pull Transformers

B3913 B39162B3913U410 January 31,

B88069X3651T902 T20-A230XSMDN PPD AB PD / PPD AB PM

B9456 B39881B9456P810 December 07,

LTE Band 17 (lower 700MHz band, blocks B and C) B8566 B39741B8566P810 February 06,

SMT power inductors. Size 12.5 x 12.5 x 8.5 mm B82477D4 MAG IN PD

B3470 B39162B3470H910 February 14,

B8094 B39212B8094P810 April 03,

SAW Components. SAW RF filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Short range devices. Date: December 01, 2010 Version: 2.

Power line chokes. Current-compensated ring core triple chokes 440/250 V AC, 12 A, 0.35 mh. Series/Type: B82745S6123N002 Date: July 2012

SAW Components. SAW filter. Automotive telematics. B3519 B39162B3519U410 May 08, Series/type: Ordering code: Date: Version:

B4402 B39781B4402P810 June 13,

Surge Arrester. 3-Electrode-Arrester. T83-A230X B88069X8910B502 Date: Version: Issue 03. Series/Type: Ordering code:

Data and signal line chokes

B3517 B39162B3517U510 January 30,

Inductors. VHF chokes. Date: June 2012

B7943 B39262B7943P810 November 7,

SAW Filters for Automotive Electronics

Surge arrester. 3-electrode arrester B88069X6731T702 T30-A230XSMD

Surge arrester. 3-electrode arrester B88069X7200B502 T23-A350X

SAW Components. SAW RF filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture GPS. Date: August 25, 2011 Version: 2.1

B84143G/Q*R/S176. Date. Function. Please send back to EPCOS MAG PEMC or to your EPCOS sales representative

B7654 B39881B7654P810 December 28,

Power line chokes. Current-compensated frame core double chokes 250 V AC, A, mh, +40 C. Series/Type: B82733F Date: March 2011

SMT power inductors. Size (mm) Date: June 2012

SMT inductors. SIMID series, SIMID 1812-A. Date: October 2012

Inductors. VHF chokes B82131, B82132, B82133, B Date: June 2012

SMT power inductors. Size (mm) Date: June 2012

SMT power inductors. Size (mm) Date: June 2012

SAW Components. SAW RF low loss filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Satellite CSS. Date: October 01, 2010 Version: 2.

Inductors. RF chokes, BC series. Date: March 2008

B3533 B39431B3533A410 December 20,

B4401 B39941B4401P810 June 13,

Current-compensated frame core double chokes 250 V AC, A, mh, +40 C

Power line chokes. Current-compensated ring core double chokes 250 V AC, A, 1 82 mh. Series/Type: B82724A/J Date: July 2012

B8810 B39172B8810P810 February 6,

B82462G2*

PPD AB PD / PPD AB PM

3 line sine wave EMC output filters for converters and power electronics

Inductors. RF chokes, LBC series. Date: June 2012

SAW Components. SAW filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture TD-SCDMA Date: Sep 21, 2010 Version: 2.1

Transcription:

Key components PF controller Series/Type: BR6000 V5.0 Ordering code: Date: May 2009 Version: 4 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF. Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! Identification/Classification 1 (header 1 + top left bar): Identification/Classification 2 (header 2 + bottom left header bar): Ordering code: (top right header bar) Film capacitors Power Factor Correction Key components PF controller Series/Type: (top right header bar) BR6000 V5.0 Preliminary data (optional): (if necessary) Department: FK PC PM PFC Date: May 2009 Version: 4 EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited

Characteristics Intelligent control Menu driven handling (plain language; Czech/Dutch/German/English/French/Polish/ Portuguese/Russian/Spanish) Self-optimizing control capability Automatic initialization Test-run possible Large voltage measuring range Recall function of recorded values Four-quadrant operation (e.g. stand by generator) Powerful alarm output 2 nd parameter set 13 steps possible with version /F and /S Control series editor Detailed expert modes Features Display - Large and multifunctional LCD (2 16 characters) - Graphic and alphanumeric - LCD illumination System parameters displayed - System voltage (V AC) - Reactive power (kvar) - Active power (kw) - Frequency - Apparent power (kva) - Apparent current (A) - Temperature ( C) - Real-time cos phi - Target cos phi - kvar value to target cos phi - Harmonics (3rd 19th) V (%), I (%) Alarm output - Insufficient compensation - Overcompensation - Undercurrent - Overcurrent - Overtemperature - Harmonics - Threshold value programmable - Internal error storage - 2 nd signal relay random Please read Cautions and warnings and Page 2 of 6

Recall recorded values - Maximum voltage (V max ) - Maximum reactive power, Q (kvar) - Maximum active power, P (kw) - Maximum apparent power, S (kva) - Maximum temperature ( C) - Maximum THD-V/THD-I - Switching cycles of capacitors - Operation time of capacitors Technical Data Weight Case 1 kg Panel-mounted instrument, 144 144 55 mm (cut out 138 138 mm) Ambient conditions - Over-voltage class - Pollution degree - Operating temperature - Storage temperature - Sensitivity to inference (industrial areas) - Spurious radiation (residential areas) - Safety guidelines - Mounting position - Humidity class Protection class - Front plate - Rear side III 2 20 C... +60 C 20 C... +75 C EN 55082-2.1995 EN 55011 10.1997 IEC 61010-1:2001 EN 61010-1:2001 Any 15% 95% without dew IP54 to IEC60529 IP20 to IEC60529 Operation - Supply voltage - Target cos phi - Switching and discharge time range - Number of control series - Control modes 110 230 V AC ±15%, 50/60 Hz 0.3 ind. 0.3 cap. 1 sec 20 min 20 series preset + control series editor for free programming Series switching (LIFO), circular switching (FIFO), self-optimized intelligent control mode Please read Cautions and warnings and Page 3 of 6

Measurement - Measurement voltage range - Fundamental frequency - Measurement current (CT) - Minimum operating current - Maximum current - Zero voltage release - Accuracy 30... 525 V AC (L L / L N) 50 and 60 Hz x/5 and x/1 Ampere possible 40 ma / 10 ma 5.3 A (sinusoidal) < 15 ms Current, voltage: 1% Reactive, active, apparent power: 2% Switching outputs Relay outputs - Number of outputs - Switching voltage/current Alarm relay Message relay 6/7 or 12/13 steps available Max. 250 V, 6 A Potential-free contact (max. 250 V, 6 A) Potential-free contact (max. 250 V, 6 A) Parameters programmable Ordering Codes Type Voltage 50/60 Hz Output Alarm output Switchover 2 nd parameter set Interface Ordering code Relay Transistor BR6000-R6 110... 230 6 Yes No No B44066R6006E230 BR6000-R12 110 230 12 Yes No No B44066R6012E230 BR6000-R12/F 110 230 12 Yes Yes No B44066R6212E230 BR6000- R12/S485* * including new Windows-Software V5.0 110 230 12 Yes Yes RS485 B44066R6412E230 Please read Cautions and warnings and Page 4 of 6

Connection plan U Cautions and warnings Controller hunting: When putting the capacitor bank into operation, it is required to avoid needless switching cycles (means permanent switching on and off of steps without significant change of consumer load). This so called controller hunting would increase the number of switching operations of the connected contactors and capacitors and decrease the expected life cycle (wear out) and, in worst case, capacitor bursting and fire, etc. This can be avoided by a proper programming of the BR6000 with the actual system parameters (current transformer prim. and sec., first kvar step, control series, switching time). Accessory for PFC-Controller BR6000 USB to RS485 converter to connect the BR6000 or other devices with interface RS485 to a PC with USB-interface. Connection of several devices at RS485 possible. Technical data see separate data sheet B44066R3333E230. U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering. Please read Cautions and warnings and Page 5 of 6

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 6 of 6