KIT FOR CAR BRAKE TESTERS SRT047BTH OPERATOR S MANUAL
CONTENTS 1. INTRODUCTION...1 2. Description of SRT047BTH Kit...2 3. Positioning the SRT047BTH Kit...2 4. CONFIGURATION...3
1. INTRODUCTION This manual provides detailed instructions for the customer, for the purpose of connecting the pedal pressure measuring devices on RAVAGLIOLI car brake testers. device functionality is ensured on brake tester systems with FW versions 1.63 or later (the FW version can be read on the first page of the program at lower right and should be available from April 2006, see example in Figure 1). FW version 1.63 Figure 1 IMPORTANT: A number of program parameters need only be changed during first installation of devices. This operation must only be performed by the RAVAGLIOLI S.p.A. skilled technical assistance personnel; for this reason access requires a password. If these parameters are not changed, even if all the following instructions are followed, the device will not work. The measuring devices besides providing excellent transmission, also make it possible to have several units interact in the same environment. The transmitter comes on by pressing the ON key, the red LED comes on. After a few seconds, the transmitter connects with the receiver and this condition is shown by the flashing red LED. To switch off press the OFF key. Switch-off occurs after about 2 sec.; the red LED goes off. Green LED ON key Red LED OFF key When not used, the transmitter goes off automatically, after it has not been connected for a few minutes (e.g., because the console is off) or after a few minutes when no pressure is applied to the cell. When the transmitter is put under charge, the green LED comes on; to ensure charge is correct, the transmitter must be off (red LED off). Page 1/4
2. Description of SRT047BTH Kit 2 1 Figure 2 3 1) Pressure-meter pedal with transmitter 2) Battery charter for the transmitter 3) Receiver to place on the console and connection cable of receiver. 3. Positioning the SRT047BTH Kit Do not position the receiver directly on metal surfaces. In the case of the console units RAVRT009/4S and RAVRT011/4S, remove the thermoformed and position this as shown below, in the inside part, using adhesive supports. Remove the thermoformed and position the receiver in the inside part using adhesive supports RAV RT011/4S RAV RT009/4S Remove the thermoformed and position the receiver in the inside part using adhesive supports Figure 3 The wiring harness must be connected between the on the CPU board inside the console. receiver and the JP14 connector JP14 Figure 4 Page 2/4
4. CONFIGURATION The transmitter and the receiver are associated in the factory. On the transmitter and on the receiver, labels are shown indicating the same address (12-figure code). See Figure 5 Same address on receiver and transmitter OFFSET GAIN Figure 5 In case of a fault affecting one of the two, both the transmitter and the receiver will have to be replaced. The transmitter is also factory set and, for this reason, during installation, the Offset and Gain parameters must be attributed. These are shown on the transmitter label. To enter the OFFSET and GAIN values, proceed as follows: Press key F1 from the initial program page (Figure 6). Figure 6 Using key F2 select TECHNICAL ASSISTANCE and press the ENTER/F3 key to confirm selection (Figure 7). Figure 7 Page 3/4
Q Using key F2 select BTH DEVICES CONFIGURATION PARAMETERS and press the ENTER/F3 key to confirm selection (Figure 8). Figure 8 Insert the following password: "F2- F2-F3-F3-F4-F4 " Using key F2 select the device to be configured and press ENTER/F3 to confirm selection (Figure 9). The grey icons indicate that the device is not available. Figure 9 Using key F2 select OFFSET and press the ENTER/F3 key to introduce the OFFSET value shown on the transmitter label (Figure 5). Enter the OFFSET value and press ENTER/F3 again to confirm (Figure 10). Using key F2 select GAIN and press ENTER/F3 to enter the GAIN value shown on the label of transmitter (Figure 5). Enter the GAIN value and press ENTER/F3 again to confirm (Figure 10). Figure 10 Press F1 to end procedure and return to initial program page. Page 4/4