SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

Similar documents
High Performance Wire and Cable

WIRE & CABLE. 55 Wire High performance wire and cable

High Performance Wire and Cable SPEC 55. Product Facts. by hot stamp, ink jet or laser, and can be potted without pre-etching.

Wire and Cable. 55 Wire Single or Dual Wall 200ºC rated, XLETFE High performance wire and cable. Features & Benefits

Spec wire. Performance Wire and Cable

SPEC 44. Wire and cable

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C

LGH High Voltage Connectors

Airport Cables & Connectors

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

System Oper. Used on Part No. Product. Environmental Solder Flux Insulation Temperature Cables Rated. Selection Series

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Heat-Shrinkable Tubing

CIR (Crush & Impact Resistant) VFD Power Cable

For tough, seaworthy wire

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, DUAL-WALL, OUTER WALL CROSSLINKED

High Temperature Flexible Control Cable OLFLEX

AEE. Canada. Australia

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

Glenair s Series 80 ASAP Cordsets for High-Speed Ethernet, USB and Firewire Applications

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, LOW NOISE, LOW SMOKE, ENHANCED INSULATION RESISTANCE

Creating. There is one basic question every customer needs to address when creating custom

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

Suflex Astra 703/105. Features. Product Description. Suggested Applications VW-1 Rated Mechanical Tubing

14 AWG 2 AWG: 600 Volt

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG

Interconnect and Termination Devices

DNVGL-CP-0400 Edition December 2015

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

HOOK-UP WIRE A STYLE TO SUIT ANY NEED

MILITARY SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

GORE Aerospace high speed data cables

Wire-to-Wire Splicing

EcoCable and EcoFlex Cable. Smaller. Lighter. 100% Recyclable.

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

Heatex Identification System. The Heatex Product Programme Offers:

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

High Temperature Flexible Control Cable

Microwave Coax. w w w. t e m p f l e x. c o m ( ) M i l f o r d R d. S o u t h G r a f t o n, M A

WIRE, ELECTRIC, MODIFIED PERFLUOROALKOXY COPOLYMER RESIN-INSULATED, NICKEL-COATED COPPER

TYGADURE FOR EXTREME APPLICATIONS

MASTER CATALOG TABLE OF CONTENTS

GEXOL WORLD CLASS OIL & GAS CABLES

MIL-Spec Application Guide

SolderSleeve One-Step Wire and Cable Terminators. Selection Guide

Stripmaster Wire Strippers

Quality: Value: Service:

COMMERCIAL ITEM DESCRIPTION

MachFlex Industrial Cables

Detailed Specifications & Technical Data

Continuous Flex Data Cable

Our wires. & cables INDEX. Insulated wires p2-p3. TAU cables p12-p15. Twisted wires p4-p7. TFA cables p16-p19. Shielded wires p8-p11

Custom Stripmaster & Custom Stripmaster Lite Wire Strippers

Gain flexibility. Save weight. Radio frequency coaxial cables

CUSTOM STRIPMASTER AND CUSTOM STRIPMASTER LITE WIRE STRIPPERS

ADVANCED FLAT CABLE SOLUTIONS

Interconnect and Termination Devices

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, UNARMORED M17/74-RG213, AND ARMORED M17/74-RG215

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/75-RG214 AND M17/75-RG365

Field Instrument Cable. Electrical Noise

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks

Stripmaster Wire Stripper. Specifications Stripping Hole Diameter in Inches (mm) Wire Size AWG

ELECTRONIC WIRE,CABLE AND TUBING FOR THE TWENTY-FIRST CENTURY AND BEYOND

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

General Information and Selection

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/28-RG058

Series 791 Connectors

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS

I-PEX MHF Micro Coaxial Connector Applicable Cable for O.D. 1.37mm Cable

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

SIMpull THHN, it slips and slides - all with NoLube.

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, M17/6-RG11 UNARMORED, M17/6-RG12 ARMORED

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/60-RG142.

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

Information technology. Generic cabling systems, General requirements

Instrumentation Cables

LTE high-performance coaxial cables (RG replacement)

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Times Microwave Systems Hermetically Sealed Assemblies

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Communication, Control, and Industrial Cable

Powerpole Connectors - PP75: up to 120 Amps

Transcription:

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C Applications Hookup and signal wire and cable used in aircraft, avionics, military electronics, satellites, helicopters, missiles, automobiles, and appliances. Features/Benefits Temperatures of 65 C to 200 C. Single- or dual-wall constructions. Small size; light weight. Exceptional chemical resistance. Mechanical ruggedness. Excellent shop handling and flexibility. Pottable insulation system. Solderable conductor. Choice of marking with hot stamp, ink jet, or excimer laser equipment. Resistance to electrical arc tracking in wet or dry conditions. Primary wire and cable configurations. SPEC 55 Insulation System Dual Wall Conductor - 19 Strand Insulations Radiation-crosslinked, modified ETFE SPEC 55 Insulation System Single Wall Conductor - 19 Strand Insulation Radiation-crosslinked, modified ETFE -8

Specifications UL Military Industry Agency Raychem 3467 MIL-W-22759/32 35 and /41 46 MIL-C-27500 (cables) 3523 Def. Stan. 61-12, Part 21, Types 1, 2, and 3 3557 Def. Stan. 61-12, Part 29 3560 British Standard G233 Civil Aviation Authority Accessory NASA preferred product list Specification 55 Approval E11749 Boeing material specification (BMS)13-48F European Space Agency 3901/011 and 3901/012 Typical Properties Typical value Test method Electrical Dielectric breakdown (.0 in) 27 kv ASTM D3032 Volume resistivity (ohm-cm) 16 ASTM D257 Surface resistance (megohms-in) 5 9 ASTM D257 Dielectric constant (permittivity) 2.7 ASTM D150 Dissipation factor.001 ASTM D150 Insulation resistance (megohms for 00 ft) 50,000 M22759/34 Physical Tensile strength (psi) 6,000 8,000 M22759/34 Elongation (%): Primary insulation (core) 170 M22759/34 Overall 0 M22759/34 Electrical arc tracking Pass ASTM D3032 Flammability Oxygen index (%) 40 ASTM 2863 Vertical flame test: Afterburn (sec) 0 Raychem Spec. 55 Burn length (in) 2.25 Raychem Spec. 55 Thermal properties Crosslinking proof test (7 hr @ 300 C) Pass M22759/34 Cold bend ( 65 C) Pass M22759/34 Chemical resistance Water absorption (%).03 ASTM D570 Hydrolytic stability Will not hydrolyze ASTM D570 Fluid immersion Pass M22759/34 Mechanical* Dynamic cut-through (lb)* 45 Raychem Spec. 55 Scrape abrasion (cycles)* 75 Raychem Spec. 55 Crush resistance (lb)* 135.062-inch-diameter mandrel Impact resistance (in-lb)* 14.2 ASTM D256 (.031 rad, 1 ft-lb arm) * Mechanical tests performed at room temperature on dual-wall 20 AWG SPEC 55 wire (55A0811-20). -9

SPEC 55 Wire Number System 55 A X X X X - AWG - XX/XX/XX - X Base color of primary wire or cable jacket. Replace X by number indicating base color for primary wire or cable jacket (0 = black; 1 = brown; 2 = red; 2L = pink; 3 = orange; 4 = yellow; 5 = green; 6 = blue; 7 = violet; 8 = gray; 9 = white). Additional number(s) after base color indicates stripe(s) color(s); for example: 95 = white wire with a green stripe; 952 = white wire with a green stripe followed by a red stripe (see example below). Component color code (required for cable constructions only). Replace XX by number(s) indicating base color followed by stripe(s) as required (see example below). Slashes are used to separate individual component wire colors. Wire size (American Wire Gauge). Conductor type. 1 = tin-coated copper; 2 = silver-coated copper; 3 = nickel-coated copper; 4 = silver-coated high-strength copper alloy (HSCA); 6 = nickel-coated HSCA. Number of conductors. 1 through 9. Class of wire. 1 = 600-V lightweight hookup wire; 2 = 600-V dual-wall hookup wire; 7 = 600-V extra-rugged airframe wire; 8 = 600-V dual-wall airframe wire. Construction. 0 = primary wire and unshielded, un cable; 1 = round-braid shielded, cable; 2 = flat-braid shielded, cable; 3 = round-braid shielded, un cable; 4 = unshielded, cable; 5 = spirally shielded, cable; 6 9 = special constructions. Example: 55A1131-22-9/96/93-9 Round-braid shielded, cable with three components of 600-V lightweight hookup wire that is 22 AWG tin-coated copper. Components are coded white, white with a blue stripe, and white with an orange stripe, with an overall white, crosslinked, modified ETFE jacket. SPEC 55 Part Numbering System Temperature rating Conductor material AWG range available Raychem part no. MIL-SPEC no. 600-V lightweight single-wall hookup wire,.006-inch nominal wall 150 C Tin-coated copper 12 30 55A0111 M22759/32 200 C Silver-coated copper 12 28 55A0112 M22759/44 200 C Nickel-coated copper 12 28 55A0113 M22759/45 200 C Silver-coated high-strength alloy 20 30 55A0114 M22759/33 200 C Nickel-coated high-strength alloy 20 28 55A0116 M22759/46 600-V lightweight dual-wall airframe wire,.008-inch nominal wall 150 C Tin-coated copper 6 26 55A0211 200 C Silver-coated copper 26 55A0212 200 C Nickel-coated copper 26 55A0213 200 C Silver-coated high-strength alloy 18 30 55A0214 200 C Nickel-coated high-strength alloy 16 26 55A0216 600-V dual-wall airframe wire,.0-inch nominal wall 150 C Tin-coated copper 00 24 55A0811 M22759/34 200 C Silver-coated copper 00 26 55A0812 M22759/43 200 C Nickel-coated copper 00 26 55A0813 M22759/41 200 C Silver-coated high-strength alloy 20 26 55A0814 M22759/35 200 C Nickel-coated high-strength alloy 20 26 55A0816 M22759/42 600-V medium-weight dual-wall airframe wire,.015-inch nominal wall 150 C Tin-coated copper 24 55A0711 200 C Silver-coated copper 16 24 55A0712 200 C Nickel-coated copper 16 24 55A0713 200 C Silver-coated high-strength alloy 16 24 55A0714 200 C Nickel-coated high-strength alloy 16 26 55A0716 -

Product Dimensions (SPEC 55 primary wire) Wire size (AWG) Raychem part number a,b Conductor stranding (no. AWG) Diameter in inches (mm) Max. weight in lb/00 ft c (g/m or kg/km) Hookup wire 600-V 55A011X a.006-inch wall thickness 30 55A011X-30-Y 7 38.024 (.61).66 (.98) 28 55A011X-28-Y 7 38.027 (.69).91 (1.35) 26 55A011X-26-Y 19 38.032 (.81) 1.4 (2.08) 24 55A011X-24-Y 19 36.037 (.94) 2.0 (2.98) 22 55A011X-22-Y 19 34.043 (1.09) 2.8 (4.17) 20 55A011X-20-Y 19 32.050 (1.27) 4.3 (6.40) 18 55A011X-18-Y 19 30.060 (1.52) 6.5 (9.67) 16 55A011X-16-Y 19 29.068 (1.73) 8.3 (12.35) 14 55A011X-14-Y 19 27.085 (2.16) 13.0 (19.35) 12 55A011X-12-Y 37 28.3 (2.62) 19.7 (29.30) Airframe wire 600-V 55A081X a.0-inch wall thickness 26 55A081X-26-Y 19 38.040 (1.02) 1.7 (2.53) 24 55A081X-24-Y 19 36.045 (1.14) 2.3 (3.42) 22 55A081X-22-Y 19 34.050 (1.27) 3.2 (4.76) 20 55A081X-20-Y 19 32.058 (1.47) 4.7 (6.99) 18 55A081X-18-Y 19 30.070 (1.78) 7.2 (.71) 16 55A081X-16-Y 19 29.077 (1.96) 9.0 (13.39) 14 55A081X-14-Y 19 27.094 (2.39) 13.8 (20.54) 12 55A081X-12-Y 37 28.111 (2.82) 20.5 (30.51) 55A081X--Y 37 26.134 (3.40) 32.4 (48.22) 8 55A081X-8-Y 133 29.195 (4.95) 60.3 (89.74) 6 55A081X-6-Y 133 27.241 (6.12) 94.5 (140.63) 4 55A081X-4-Y 133 25.3 (7.87) 150.0 (223.22) 2 55A081X-2-Y 665 30.408 (.36) 239.0 (370.51) 1 55A081X-1-Y 817 30.470 (11.94) 290.0 (483.60) 0 55A081X-0-Y 45 30.5 (12.95) 377.0 (569.90) 00 55A081X-00-Y 1330 30.570 (14.78) 487.0 (744.00) a X = conductor type (see Part Numbering System on previous page) b Y=color as specified c Weight is for tin-coated copper conductor Note: MIL-W-22759 requires a fabric overbraid on 2 through 00 AWG; special Raychem part numbers are assigned to these MIL-SPEC constructions. -11

SPEC 55 Cable Constructions Construction Unshielded, un Unshielded, Shielded (round braid), Shielded (flat braid), Number of components a Type of conductor or shield material: 1 = tin-coated copper 2 = silver-coated copper 3 = nickel-coated copper 4 = silver-coated high-strength copper alloy 6 = nickel-coated high-strength copper alloy Component conductor a Shield material a Part number Light wt. b Medium wt. 2 9 1 55A01X1-AWG-Y 55A08X1-AWG-Y 2 55A01X2-AWG-Y 55A08X2-AWG-Y 3 55A01X3-AWG-Y 55A08X3-AWG-Y 4 55A01X4-AWG-Y 55A08X4-AWG-Y 6 55A01X6-AWG-Y 55A48X6-AWG-Y 2 9 1 55A41X1-AWG-Y 55A48X1-AWG-Y 2 55A41X2-AWG-Y 55A48X2-AWG-Y 3 55A41X3-AWG-Y 55A48X3-AWG-Y 4 55A41X4-AWG-Y 55A48X4-AWG-Y 6 55A41X6-AWG-Y 55A18X6-AWG-Y 1 9 1 1 55A11X1-AWG-Y 55A18X1-AWG-Y 2 2 55A11X2-AWG-Y 55A18X2-AWG-Y 3 3 55A11X3-AWG-Y 55A18X3-AWG-Y 4 1 55A11X4-AWG-Y 55A18X4-AWG-Y 6 3 55A11X6-AWG-Y 55A18X6-AWG-Y 1 9 1 1 55A21X1-AWG-Y 55A28X1-AWG-Y 2 1 55A21X2-AWG-Y 55A28X2-AWG-Y 3 1 55A21X3-AWG-Y 55A28X3-AWG-Y 4 1 55A21X4-AWG-Y 55A28X4-AWG-Y 6 1 55A21X6-AWG-Y 55A28X6-AWG-Y b X = no. of wire components Y = color code For complete part number, see Part Numbering System on page -. MIL-C-27500 Cable Part Numbering System M27500 - AWG XX X X XX Jacket style and material 00 = no jacket; 23 = crosslinked, modified ETFE, white; 73 = double jacket crosslinked, modified ETFE, white Shield material and style U = no shield; T = tin-coated copper, round; J = tin-coated copper, flat; S = silver-coated copper, round; G = silver-coated copper, flat; N = nickel-coated copper, round; V = tin-coated copper, round, double shield; W = silver-coated copper, round, double shield Number of components. 1 through 9; components = 0 Basic wire spec (MIL-W-22759) and slash sheet SB = 32 = 55A0111; SC = 33 = 55A0114; SD = 34 = 55A0811; for 2 AWG and larger, use 55A8039; SE = 35 = 55A0814; SM = 41 = 55A0813; for 2 AWG and larger, use 55A8595; SN = 42 = 55A0816; SP = 43 = 55A0812; for 2 AWG and larger, use 55A6089; SR = 44 = 55A0112; SS = 45 = 55A0113; ST = 46 = 55A0116 Example: M27500-20SB3T23 = 55A1131-20-9/96/93-9 Military part no. Raychem part no. SPEC 55 is a registered trademark of Raychem Corporation. -12