LINAX 4000L Continuous-line recorder

Similar documents
POINTAX 6000L2 Point Recorder

LINAX 4000H Continuous line recorder

POINTAX 6000M Point recorder

DIGEM f 96 x 48 EK. Applications. Description

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

TZIF 4. Current-to-Pulse Converter 10/ EN

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Switching power supplies CP range, Linear power supplies CP-L range. Content

Overcurrent Protection / 7SJ45

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

MINI-PS AC/24DC/1.3

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Paperless Recorder PR20

Electronic timer CT-TGD.22

XUA1 - AC Voltage and phase balance relay

For Immediate Delivery call KMParts.com at (866)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

QUINT-PS-24DC/24DC/10

Light-strip indicator

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

METRATESTER 5+ Tester for DIN VDE /6.15

Electronic timer CT-SDD.22

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

T22. Torque transducer. Special features. Data sheet

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Analog indicators. 1/2 Regulations and standards. 1/4 Technical descriptions

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

RS Pro ENGLISH. Datasheet

XF2 Frequency Relay. Manual XF2 (Revision A)

SINEAX B 811 Power Pack with additional Functions

MAVOWATT 4 Multifunction Power Meter

MINI-PS AC/2X15DC/1

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

Electronic Thermostat TE-1 Version according to EN

U1601 ENERGY CONTROL SYSTEM

OPTITEMP TT 20 Technical Datasheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

v v PMA With numerous functions and robust construction, the KS 3930 A/B line recorders are ideal for universal industrial applications.

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-MFS.21

METRISO 5000 D-PI Digital High-Voltage Insulation Tester

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

High precision measurement system for current and voltage IHC-A/B-RM01/03

J IPC IGBT power converter

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Electronic timers CT-S range Selection and ordering details

Transformers, Power Supply Units and Socket Outlets

KINAX SR 719 Programmable Transmitter for Position Feedback

Analog signal converters CC range

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Wind Transmitter First Class

RS Pro ENGLISH. Datasheet

Coupling Relays and Converters

SINEAX U 553 Transducer for AC Voltage

Power supply CP-D 24/1.3

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Temperature head transmitter itemp TC TMT 188

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

Type CP-S, CP-C & CP-A Switch mode

Differential pressure sensors

Electronic timer CT-SDS.22

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Power supply CP-D 12/2.1

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

IRI1-ER - Stabilized Earth Fault Current Relay. Manual IRI1-ER (Revision A)

Temperature transmitter itemp RTD DIN rail TMT 127

Technical features table for miniature circuit-breakers SH 200 Series

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

MINI MCR-SL-UI-f(-SP)

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

T40FH. Torque flange. Special features. Data sheet

Analog signal converters CC-E I/I

QUINT-PS AC/24DC/40

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

T40B. Torque Flange. Special features. Data sheet. Overall concept

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Thermistor motor protection relays

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Transcription:

-48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged design Applications The configurable continuous-line recorder LINAX 4000L serves to record slowly changing measured quantities. DC current and DC voltage can be connected directly. The recorder is meant for installation in panels. Description The LINAX 4000L is a microprocessor-controlled, continuous-line recorder. It is supplied with 1 to 4 line channels. The recorder is connected to transducers and is served to measure process-related signals. The recorder is supplied with signal inputs DC 0... 20 ma / 0... 10 V or DC 4... 20 ma. High electromagnetic compatibility (EMC) as well as high common mode and series mode rejection of interference voltages ensure non-problem use of the LINAX 4000L even in rough environments. Applied rules and standards A) International standards IEC 484 IEC 1010-1 IEC 664 IEC 68-2-6 IEC 68-2-27 IEC 529 IEC 801, EN 60801 EN 55011 IEC 721-- IEC 742 B) German standards DIN 4802 DIN 1624 DIN 481 Potentiometric recorders Safety requirements for electrical equipment for measurementontrol and laboratory use Overvoltage category, degree of pollution Mechanical stress (vibrations) Mechanical stress (shock) Degrees of protection provided by enclosures Immunity to interference of electromagnetic influences Radio interference suppression Climatic environmental conditions Isolating transformers and safety isolating transformers requirements Scales Recording paper Cases Symbols and their meaning Symbol X1n X2n X2n X1n Meaning Lower range limit nom. range Upper range limit nom. range Range span nom. range GOSSEN-METRAWATT GMBH

Technical data Analog inputs and measuring ranges DC current 0... 20 ma; Ri = 40 Ω 4... 20 ma; Ri = 50 Ω DC voltage 0...10 ma; Ri = 500 kω Deadband Setting time Reference conditions Accuracy Variations Display 0.25 % of range span 2s, 5s, 20s, 60s Ambient temperature 25 C ± 1K Relative humidity 45... 75 % Auxiliary voltage Hn ± 2 %, nominal frequency ± 2% Mounting position Front upright ± 2 Warm-up time 0 min Deviation according to IEC 484 Temperature Humidity Scale One graduation per measuring system Scale face 5 mm wide Character size 2 mm Class 0.5 referred to range span 0.2 %/10 K, additionally Note influence on recording paper according to DIN 1624 Auxiliary voltage Hn 0.1 % at 24 V AC/DC ± 20 % 0.1 % at 24 V AC +10 % / 15 % 0.1 % at 115 V AC +10 % / 15 % 0.1 % at 20 V AC +10 % / 15 % AC interference voltages (see perm. interference voltages) 0.5 % of range span Magnetic field of external origin 0.5 mt 0.5 % of range span Mechanical stress according to DIN IEC 68-2-6/27 Transport Impact: 0 g/18 ms Vibration: 2 g/ 5... 150 Hz in function Vibration: 0.5 g/± 0.04 mm/ 5...150 Hz/ 2cicli During and after the effect ± 0.5 % of range span Recording Arrangement of measuring systems and color correlation 1 2 4 No. of line channels green rd channel red 2nd channel blue 1st channel violet 4nd channel Line recording Fiber recording pen with inkwell of approximately 1.4 ml, line length approximately 100 m, distance between the tips of the fiber recording pens 2 mm. Recording Chart speed Recording chart Visible chart length Recording width Chart intake (with roll chart) Auxiliary voltage 24 V AC/DC ± 20 % Power consumption with max. fitting approx. 15 W/20 VA 24/110/20 V AC +10 %/ 15 % Frequency range 47.5... 6 Hz Power consumption with max. fitting approx. 20 W/25 VA Climatic suitability Speed selectable on control panel: 1/5/10/20/60/120/00/600 mm/h 2 m roll chart or 16 m fanfold chart 60 mm 100 mm (chart width 120 mm, DIN 1620) Via automatic paper take-up device (daily tear-off or take-up of the 2 m possible) Ambient temperature 0... 25... 50 C Transport and storage temperature 40... +70 C Relative humidity 75 % annual average; max. RH 85 % in function Climatic class K acc. to IEC 721-- 2 GOSSEN-METRAWATT GMBH

Electrical safety Test according to DIN EN 61010-1 (classification VDE 0411) and/or IEC 1010-1I Protection class I Overvoltage category III at the power input II at inputs Degree of pollution 2 in the device and at the connection terminals according to VDE 0110, parts 1 and 2 Test voltage.75 kv measuring channels to energy supply 2.20 kv protective conductor to energy supply Immunity to interference: test according to IEC 801 Type of test Test severity Variation Severity level ESD (1/0 ns) 6 kv HF field radiated 80 MHz... 1 GHz line-guided 0.15... 80 MHz Burst (5/50 ns) on Power line Test lead Surge (1,2/50 µs) on Power line common differential 1 MHz pulse on Power line common differential 10 V/m 10 V/m 2kV 1kV 2kV 1kV 2kV 1kV The NAMUR industry standard EMC is met (Interface cables shielded). 2 Functional extra low voltage with protective separation (PELV) Between power input measuring channels, control leads, interface cables acc. to VDE 0100 part 410 and VDE 0106 part 101. Electromagnetic compatibility The protection goals of the EMC directive 89/6/EWG as to radio interference suppression according to EN 55011 and as to immunity to interference according to EN 50082-2 are complied with. Radio interference suppression Limit class B according to EN 55011 or Post decree 24/92. Permissible interference voltages Test Type Series mode interf. voltage Peak-peak Push-pull rejection Common mode interference voltage Common mode rejection Scope of delivery Permissible interference 0. meas. span max. V 5 db 60 V DC /250 V AC 8 db for DC / 96 db for AC 1 copy of operating instructions 2 fasteners 1 chart roll or fanfold pack, inserted in the unit 1 fiber recording pen per measuring channel Additionally, depending upon the order: Centering angle bracket for installation in mechanical grids; reading ruler(s) GOSSEN-METRAWATT GMBH

Connection, case and installation Electrical connections Protection type IP 20 Screw and plug terminals for signal inputs Max. wire cross section 2 x 1 mm 2 Screw terminals for line connection Max. wire cross section 4 mm 2 Case Molded material for installation in panels or mechanical grids (see dimensional drawing for dimensions) Protection type of case according to IEC 529 Front panel IP 54 Rear panel IP 20 Position of use Lateral [ 0... 0... +0 ], inclined to the rear 20, to the front 20 Mounting distance Horizontal or vertical 0 mm, it must be possible to open the door of the case through 100 Weight kg, approx. Dimensional drawing (dimensions in mm) Color of case Silica-gray according to RAL 702 Door of case Molded material or door with metal frame RAL 702 and glas pane, anti-glare Fastening of case With 2 fasteners (optionally for installation in panel or mechanical grid), centering angle brackets are required for installation in mechanical grids Panel cutout Wirung diagrams Signal inputs 4 GOSSEN-METRAWATT GMBH

Order code (cont.) Descrizione LINAX 4000L with identical DC measuring ranges for all channels A4150 Front dimensions 144 144mm 1 line channel AA001 2 line channels AA002 line channels AA00 4 line channels AA004 Meas. ranges DC 0... 20 ma, selectable DC 0... 10 V Lower range limit X1 Upper range limit X2 X1 = 0 ma X2 = 20 ma BA001 Meas. ranges DC 4... 20 ma X1 = 4 ma X2 = 20 ma BA002 Scale 1st channel: same as measuring range BB001 without graduation BB002 0... 100 BB00 as per request BB900 Reading ruler 1st channel: without reading ruler BC000 same as scale BC001 0... 100 BC002 as per request BC900 Scale 2nd channel, only for 2-channel or multi-channel versions: same as scale 1st channel, but markings CB... Reading ruler 2nd channel, only for 2-channel or multi-channel versions: same as 1st channel, but markings CC... Scale rd channel, only for -channel or 4-channel version: same as scale 1st channel, but markings DB... Reading ruler rd channel, only for -channel or 4-channel version: same as 1st channel, but markings DC... Scale 4th channel, only for 4-channel version: same as scale 1st channel, but markings EB... Reading ruler 4th channel, only for 4-channel version: same as 1st channel 1, but markings EC... CBxxx CCxxx DBxxx DCxxx EBxxx ECxxx Recording type for roll (2 m) KA001 for fanfold pack (16 m) KA002 Auxiliary voltage: AC: 21 V... 24 V... 26 V LA001 AC: 98V...115V... 126 V LA002 AC: 196 V... 20 V... 25 V LA00 DC/AC: 20 V... 24 V... 28 V LA004 (Cont d next page) GOSSEN-METRAWATT GMBH 5

Order code (cont.) Descrizione A4150 Front door Plastic MA001 Metal MA002 Label Blank with GOSSEN-METRA- WATT logo Blank without logo With inscription as per request, 1 line/meas. point with max. 1 characters NA000 NA001 NA900 Test protocol None PA000 With factory certificate according to DIN 50049 PA001 Operating instructions German RA000 None RA001 English RA002 French RA00 Italian RA004 Ordering examples Clear text Ordering code LINAX 4000L with identical DC meas. range for all channels A4150 continuous-line recorders AA00 Meas. range DC 0... 20 ma BA001 Scale 1st channel: 0... 100 BB00 Scale 2nd channel: 0... 5 MW CB900 Scale rd channel: 0... 00 C DB900 Recording type for fanfold pack (16 m) KA002 Auxiliary voltage AC: 20 V LA00 Front door Plastic MA001 Ordering code: A4150 / AA00 / BA001 / BB00 / CB900 0... 5 MW / DB900 0... 00 C / KA002 / LA00 / MA001 6 GOSSEN-METRAWATT GMBH

Accessories s ending with a letter are complete and need not to be commented. s ending with a numeral must be commented with the following markings. Description Scale without graduation, beginning and end marked Scale, graduation as per request Graduation: A410A A410 AA900 Reading ruler, graduation as per request Graduation: A4120 AA900 Label for measuring point with GOSSEN-METRAWATT logo without GOSSEN-METRAWATT logo Channel green without inscription Channel green with inscription Channel red without inscription Channel red with inscription Channel blue without inscription Channel blue with inscription Channel violet without inscription Channel violet with inscription A4110 AA000 AA001 BA001 BA900 BB001 BB900 BC001 BC900 BD001 BD900 Screw terminal with 5 connectors Screw terminal with connectors A404A A404B 4 each centering angle (with installation in grid) A416A Consumable items (cont d) s ending with a letter are complete and need not to be commented. s ending with a numeral must be commented with the following markings. Description Recording chart, chart width 120 mm, recording width 100 mm Chart roll 2 m, graduation 0... 100, minimum ordering quantity 25 rolls Time graduation/ speed None A401A 10 mm/h A401B 20 mm/h A401C 60 mm/h A401D 120 mm/h A401E Chart roll 2 m, graduation 0... 100, minimum ordering quantity 25 rolls A4070 Time graduation/ speed as per request CA900 (cont d) GOSSEN-METRAWATT GMBH 7

Consumable items (cont d) s ending with a letter are complete and need not to be commented. s ending with a numeral must be commented with the following markings. Description Chart roll 2 m, with calibrated graduation, minimum ordering quantity 25 rolls A4071 Calibrated graduation as per request AA900 Inscription as per request BA900 Time graduation/ speed as per request CA900 Fanfold pack 16 m, graduation 0... 100, minimum ordering quantity 25 packs Time graduation/ speed None A401L 10 mm/h A401M 20 mm/h A401N 60 mm/h A401P 120 mm/h A401Q Fanfold pack 16 m, graduation 0... 100, minimum ordering quantity 25 packs A4075 Time graduation/ speed as per request AA900 Fanfold pack 16 m, with calibrated graduation, minimum ordering quantity 25 packs A4074 Calibrated graduation as per request AA900 Inscription as per request BA900 Time graduation/ speed as per request CA900 Recording styli Stylus green Stylus red Stylus blue Stylus violet A406B A406A A406C A406D Printed in Germany Subject to change without notice GOSSEN-METRAWATT GMBH Thomas-Mann-Str. 16-20 90471 Nürnberg, Germany Phone +49 911 8602-0 Fax +49 911 8602-669 http://www.gmc-instruments.com e-mail: info@gmc-instruments.com