Installation Guide for Andersen 400 Series Gliding Windows

Similar documents
Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

Installation Guide for Andersen 200 Series Tilt-Wash Picture, Transom and Circle Top Windows

Installation Guide for Andersen Frenchwood Patio Door Sidelights and Transoms

Installation Guide. for Andersen 400 Series Tilt-Wash Picture Windows with Stormwatch Protection (High-Performance Impact Resistant Glass)

Installation Guide for Architectural Wood Hinged Windows

Installation Guide for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006

Panel Assembly and Installation

Sash Replacement Guide for Andersen 400 Series Tilt-Wash Transom Windows

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window

Installation Guide for Andersen Architectural Clad Awning Windows

Installation Guide for Andersen Architectural Clad Inswing Entry and Patio Doors

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Guide for Andersen Architectural Clad Hinged Windows

Fixed Upper Sash Replacement Guide for Andersen 400 Series Woodwright Springline Single-Hung Windows

Sash Replacement Guide for Andersen Impact Resistant Casement Windows

for Andersen Frenchwood Hinged and Outswing Patio Doors, Sidelights, and Transoms

Steel Reinforced Joining Guide (Horizontal / Vertical)

Non-Reinforced Joining Guide (Horizontal/Vertical)

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows

1-Way Vertical Joining (Pages 2-22) 1-Way Horizontal Joining (Pages 23-44)

3/4" LVL Reinforced Joining Guide

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products

WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

Assembled Patio Door Installation Guide 2-Panel Patio Door with Non-Welded Frame

Installation Guide for E-Series/Eagle Ascent 2 or 4 Panel Gliding (Sliding) Patio Doors

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

Installation Instructions for E-Series 2 or 4-Panel Gliding and French Gliding Patio Doors

Passive Panel Replacement

Read guide from beginning to end before starting installation. Read and follow all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read and follow all warnings and cautions during unit installation.

Follow instructions from foam, sealant and flashing manufacturer regarding material application and compatibility with this product.

Stationary Panel Replacement

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

Reinforced 10 Bow Window Assembly and Installation Guide for Andersen 400 Series Transom Joined Casement Windows

Passive Panel Replacement Guide

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

Tools required by installer: Materials required by installer:

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system.

Vinyl Windows and Doors Manufactured by Pella Corporation

Flashing Materials. Rough Opening Preparation

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO

HR175 Sash Replacement Kit Installation Instructions

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

INSTALLATION INSTRUCTION FOR CLAD BOW WINDOWS WITHOUT HEAD AND SEAT BOARD

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

Sun Windows General Information New Construction Hinged Door Installation Instructions

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

INSTALLATION INSTRUCTIONS FOR FORGENT SLIDING PATIO DOORS RECOMMENDATIONS FOR COMMON INSTALLATION OF SLIDING PATIO DOORS.

Reglazing Guide for Andersen 400 Series Specialty Windows with Stormwatch Protection (High-Performance Impact Resistant Glass)

VISTALUXE CASEMENT, AWNING, & PICTURE WINDOW

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Vinyl Windows Manufactured by VPI Quality Windows

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Eagle clad double-hung window installation instructions

Vinyl Windows and Doors

RECREATIONAL VEHICLE DOOR INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION FOR WOOD DOUBLE-HUNG AND CASEMENT WINDOWS USING WOOD BRICKMOULD OR FLAT CASING

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS

Wood Hinged Patio Door Installation Instructions

Sliding Glass Door Assembly and Installation Guide

8/7/ HP SWING DOOR INSTALLATION INSTRUCTIONS

Vinyl Windows and Doors Manufactured by VPI Quality Windows

NEW CONSTRUCTION PATIO DOOR INSTALLATION INSTRUCTIONS (WITH NAILING FLANGE)

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD SLIDING PATIO DOOR PUERTA CORREDERA PARA PATIO

WINDOW REPLACEMENT INSTRUCTIONS FOR SINGLE-HUNG, DOUBLE-HUNG, CASEMENT, AWNING INTO EXISTING CASEMENT FRAME USING FRAME SCREWS

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750.

Vinyl Windows and Doors

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

Vinyl Windows and Doors

Integrity Polygon and Round Top Installation and Finishing Instructions

UNIT 5: EXTERIOR DOORS AND WINDOWS

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

INOVO 2-LITE SLIDING PATIO DOOR

Installation Materials Required: Tools Required: 6" self-adhesive flashing. Shims. 3-foot level 6-foot level Tape measure 1/8" drill bit

INSTALLATION INSTRUCTIONS FOR TEUTONIC ENTRANCE DOOR RECOMMENDATIONS FOR COMMON INSTALLATION OF ENTRANCE DOORS.

Vinyl Windows and Doors

Sash may be heavy. Use a reasonable number of people with sufficient strength to lift, carry, remove and install. Tape broken glass with duct tape bef

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.

VINYL WINDOWS (new construction or replacement) page 2. VINYL PATIO DOORS pages WOOD CLAD WINDOWS (new construction).page 5 WOOD CLAD WINDOWS

I n s t a l l a t i o n I n s t r u c t i o n s

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

INTERIOR. Checkrail. Flashing tape

26- H i n g e d P a t i o D o o r s - I n s w i n g

INSTALLATION INSTRUCTION SINGLE PANEL, SINGLE PANEL WITH SIDELIGHT COMBINATION AND 20 MINUTE FIRE RATED WOOD FRAME ENTRY DOOR

T he Double-Hung Replacement System replaces the sash and balance system of an older double-hung window. The

Transcription:

for Andersen 400 Series Gliding Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the benefits of your Andersen product are to be fully attained. Therefore, please read and follow this instruction guide completely. If your abilities do not match this procedure s requirements, contact an experienced contractor. You may direct any questions about this or other products to your local Andersen dealer, found in the Yellow Pages under Windows or call Andersen WindowCare service center at 1-888-888-7020 Monday through Friday, 7 a.m. to 7 p.m. Central Time and Saturday, 8 a.m. to 4 p.m. Central Time. Thank you for choosing Andersen. Every assembly and installation is different (windloads, structural support, etc.). Andersen strongly recommends consultation with an Andersen supplier or an experienced contractor, architect, or structural engineer prior to the assembly and installation of any Andersen product. For installation methods not covered in this guide, (i.e. through jamb) please visit the Architect Detail File on the web (www.andersenwindows.com). Andersen has no responsibility in regard to the post-manufactured assembly and installation of Andersen products. Using ladders and/or scaffolding and working at elevated levels may be hazardous. Follow equipment manufacturer's instructions for safe operation. Use extreme caution when working around window and door openings. Falling from opening may result in personal injury or death. Improper use of hand/power tools could result in personal injury and/or product damage. Follow manufacturer's instructions for safe operation of equipment. Always wear safety glasses. Weight of window/door unit(s) and accessories will vary. Use a reasonable number of people with sufficient strength to lift, carry, and install window and door unit(s) and accessories. Always use appropriate lifting techniques. Unless specifically ordered, Andersen windows and doors are not equipped with safety glass, and if broken, could fragment causing injury. Many laws and building codes require safety glass in locations adjacent to or near doors. Andersen windows are available with safety glass that may reduce the likelihood of injury when broken. Information on safety glass is available from your local Andersen dealer. Andersen Head Flashing and Installation Flanges DO NOT take the place of standard window and door flashing. Unit must be properly flashed and sealed with silicone for protection against water and air infiltration. Use non-reflective flashings. Highly reflective flashing tapes can raise the surface temperature of the vinyl to the point where vinyl deformation and product damage may occur. Do not apply any type of film to glass. Thermal stress conditions resulting in glass damage could occur. Use of movable insulating materials such as window coverings, shutters, and other shading devices may damage glass and/or vinyl. In addition, excessive condensation may result causing deterioration of windows and doors. Andersen and Andersen WindowCare are registered trademarks of Andersen Corporation. All other marks where denoted are marks of Andersen Corporation. 1998-2005 Andersen Corporation. All rights reserved. 1 Instruction Guide 0004360 Revised 06/03/05

Parts Included (1) Instruction Guide (1) Gliding Window Unit (1) Temporary Handle Component Identification Tools & Supplies Safety Glasses 1-3/4" Roofing Nails Hammer Insulation Level Caulk Gun Carpenter s Square Silicone Sealant Tape Measure Flat Blade Screwdriver Shims and Blocks Utility Knife Temporary Handle Window Unit Steel fasteners will corrode when used with ACQ Pressure Treated Lumber. Obtain and use the appropriate size stainless steel fasteners, as called out in this installation guide, to fasten unit to any rough opening made from ACQ Pressure Treated Lumber. Failure to use stainless steel fasteners may result in fastener corrosion causing product damage. 1. Unit Preparation Banding Tape Packing Blocks Weight of window and door unit(s) and accessories will vary. Use a reasonable number of people with sufficient strength to lift, move and carry window and door unit(s) and accessories. Always use appropriate lifting techniques. Exterior Side Up When joining multiple units together, a Narrow or Support Joining Kit is necessary. Please refer to instruction guide for narrow joining or support joining. 4-1/2" Do not remove banding tape and packing blocks until Installation Flange 4-1/2" Wall Thickness Step 4. Place unit on a clean, flat surface with exterior side up. For 4-1/2" wall thickness installations, carefully flip Installation Flanges up into their locked position. Start in center of Installation Flange and work out to both ends. For 4-1/8" wall thickness installations, remove Installation Flanges, reverse, and replace as shown. 4-1/8" Installation Flange Reversed 4-1/8" Wall Thickness 2

2. Prepare Rough Opening For instructions for installation into masonry and brick veneer walls, refer to Masonry and Brick Installation section on Page 7 of this guide. Frame rough opening to dimensions in the Andersen Product Guide for Professionals or prepare existing rough opening. Masonry rough opening must be 1/2" greater than unit width and height. Make sure sill plate is level by checking with a level. Shim sill plate to level. Make sure rough opening is plumb by checking with a level. Make sure rough opening is square by placing tape measure diagonally to measure across rough opening, upper left to lower right and upper right to lower left corner. If measurements are the same, opening is square. Tape Measure Level Interior View 3. Install Window Unit Weight of window and door unit(s) and accessories will vary. Use a reasonable number of people with sufficient strength to lift, move and carry window and door unit(s) and accessories. Always use appropriate lifting techniques. Banding Tape Do not install window unit directly on sill plate. Sill may bow and interfere with window operation. Elevate unit on shims. Level Unit must be installed plumb, level, and square to operate correctly. Install unit in a vertical position only. Remove Packing Blocks from unit. Apply blocks on sill plate under Side Jambs and at midpoint of Sill. Lift unit into rough opening from the exterior. Shim corners of Sill to level and center unit. Blocks at Corners Sill Plate Interior View 3

4. Check for Plumb, Level, and Square Steel fasteners will corrode when used with ACQ Pressure Treated Lumber. Obtain and use the appropriate size stainless steel fasteners, as called out in this installation guide, to fasten unit to any rough opening made from ACQ Pressure Treated Lumber. Failure to use stainless steel fasteners may result in fastener corrosion causing product damage. Carpenter s Square Nail One Corner (First Hole) Tape Measure Nail one corner of unit through Installation Flange, from the exterior, using 1-3/4" roofing nails. Plumb, level and square unit. Shim at corners as needed to level unit. Remove banding tape. Check for square using a tape measure and carpenter s square from the exterior. Place tape measure diagonally across unit, upper left to lower right and upper right to lower left corners. If measurements are the same, unit is square. If unit is not square adjust with shims as required. Check for equal space between unit and rough opening on all sides of window, then nail remaining corners. Check for bow at center of frame. Shim or block to straighten if necessary. Finish fastening through Installation Flange to rough opening, spacing nails or fasteners a maximum of 6" on center around entire frame. Hammer Banding Tape Exterior View 4

5. Apply Flashing Tape Unit must be properly flashed and sealed for protection against water and air infiltration. Use non-reflective flashings. Highly reflective flashing tapes can raise the surface temperature of the vinyl to the point where vinyl deformation and product damage may occur. This instruction step depicts one of many options for proper flashing. Moisture infiltration problems in any type of building can be reduced by properly flashing and/or sealing around all building openings, including windows and doors. Proper flashing under and around window and door openings can reduce moisture problems, but the performance of any building system depends upon the design and construction of the building system in its entirety, which should address local environment, climate, building codes and product and material limitations. The design and installation of flashing and sealing systems are the responsibility of the architect, contractor, installer, and/or the manufacturer of the building exterior specified for the project. Apply flashing tape over Installation Flange at sill. Apply flashing tape over Installation Flange at sides, overlapping flashing tape at sill. Apply flashing tape over Installation Flange at head, overlapping flashing tape at sides. Sill (apply first) Flashing Tape Head (apply third) Sides (apply second) 6. Unit Operation and Glide Adjustment Place Temporary Handle over stud on sash and turn to operate Sash (see notice). Both Sash must be closed for lock to function. Open Sash slightly and check reveal, full length, between Sash and Side Jamb. Space must be even for best weatherstrip contact. For Lower Glides adjust by carefully removing Buttons on inside meeting stile trim. Insert a flat blade screwdriver into slot on Adjustment Cam and rotate to move corner of sash up or down. For Upper Glides adjust upward as needed for proper operation in head jamb track. Temporary Handle, included with window, is to be used until permanent handle is installed. Button Utility Knife Adjustment Cam Lower Glides Flat Blade Screwdriver Stud Temporary Handle Glide Sill Correct adjustment of Upper and Lower Glides will allow sash to slide freely but will not allow it to be lifted out. DO NOT overturn Adjustment Cam. Head Flat Blade Screwdriver Adjustment Cam Upper Glides Exterior View 5

7. Insulate and Apply Silicone Sealant Insulation When insulating between unit frame and rough opening DO NOT overpack batt insulation or overfill with expandable foam. Bowed jambs may result causing performance problems and/or incorrect operation of unit. Putty Knife Interior View Insulate full perimeter between unit and interior rough opening. Apply backer rod and silicone sealant to gap around exterior between siding and frame. All exterior siding, or other finish, must have a 1/4" clearance around unit except at sill in masonry installations. Apply silicone sealant around full exterior perimeter of unit after siding, or other finish, is applied. Extension Jambs can be placed into channel of inside frame and nailed into place. Hold firmly to avoid tipping. Silicone Sealant Around Perimeter Inside frame Exterior View Extension Jamb 8. Installation of Interior Casing (Supplied by Others) Attach interior casing using 4d (1-1/2") finish nails. Locate nails following diagrams to avoid damaging frame edge. Finish Nail Interior Casing Head Finish Nail Interior Casing Side Jamb Sill Finish Nail 6

Flying particles during masonry cutting can cause personal injury and damage glass. Always wear safety glasses when cutting. Cover window unit to avoid damage. Steel fasteners will corrode when used with ACQ Pressure Treated Lumber. Obtain and use the appropriate size stainless steel fasteners, as called out in this installation guide, to fasten unit to any rough opening made from ACQ Pressure Treated Lumber. Failure to use stainless steel fasteners may result in fastener corrosion causing product damage. Provide a minimum clearance of 1/2" from top of brick or masonry to the bottom of any portion of sill. Failure to do so could result in operation problems from bowing of sill. Acid solutions commonly used to wash masonry will damage glass, fasteners, hardware, and metal flashings. Follow cleaning solution manufacturer's recommendations carefully. Protect and/or cover Andersen products during cleaning process to prevent acid contact. If solution does come in contact with unit, immediately wash all surfaces with clean water. For installations where exterior brick is already applied, remove Installation Flanges. Installation in Masonry & Brick Veneer Walls Construction using Wood Bucks When using wood bucks follow the same procedure as in wood frame construction in Step 3 on Page 3. Silicone Sealant 1/2" Wood Block Brick Wood Frame with Brick Veneer Shim Masonry Installation Using Jamb Clips by Andersen and Furring Strips Remove all Installation Flanges on head, sides, and sill. Install Metal Jamb Clips in kerfs on back of jambs and secure using 5/8" fasteners. Bend and secure Metal Jamb Clips to wall or fasten to furring strips. Use number of Metal Jamb Clips as recommended by architect or structural engineer. Install and center window in rough opening. Level, plumb, and square. Shim at all anchor locations, as needed, to level unit. Secure Metal Jamb Clips to wall furring strips. For unit operation and adjustment, refer to Step 6 on Page 5. Side Jamb Metal Jamb Clip Exterior Side Up Metal Jamb Clip Side Jamb 1/4" at Head and Side Jambs Masonry Installation Using Jamb Clips by Andersen and Furring Strips Furring Strip 7

Installation in Masonry & Brick Veneer Walls (Continued) Masonry Installation Using Jamb Clips by Andersen Bend Metal Jamb Clips around furring strips in 8" walls or secure clips into mortar joints in 12" walls. For unit operation and adjustment, refer to Step 6 on Page 5. Metal Jamb Clips Metal Jamb Clips 1/4" at Head and Side Jambs Masonry Installation Using Jamb Clips by Andersen Exterior View Finishing, Cleaning, and Maintenance Instructions INTERIOR FINISHING Read and follow finishing manufacturer s instructions and warnings on each container of finish material for priming, painting, staining, and varnishing. DO NOT expose unfinished wood to high moisture conditions, excessive heat or humidity. Finish interior wood surfaces immediately after installation. Unfinished wood surfaces will discolor, deteriorate, and/or may bow and split. DO NOT stain or paint weatherstrip, silicone beads, vinyl, glass, or hardware. Acid solutions used to wash masonry will damage glass, fasteners, hardware, and metal flashing. Follow the acid solution manufacturer's instructions carefully. Protect and/or cover Andersen products during the cleaning process to prevent acid contact. If acid does come in contact with unit, immediately wash all surfaces with clean water. CLEANING Clean exterior frame, sash members, and insect screens using a mild detergent-and-water solution and a soft cloth or brush. DO NOT use abrasive cleaners or solutions containing corrosive solvents. For persistent dirt or grime, use a nonabrasive cleanser or a mixture of water and alcohol or ammonia. MAINTENANCE Immediately sand and refinish any interior wood that becomes stained or mildewed to prevent further discoloration and/or damage. For further information, contact your local Andersen dealer. Dealers can be found in the Yellow Pages under Windows. 8

Sash Won't Stay On Track Homeowner Adjustment Guide Possible Cause: Top glide foot not adjusted up. Solution: Adjust top glide foot until it seats fully into glide rib groove. Possible Cause: Broken glide base or foot. Solution: Take sash out of frame and replace broken glide assembly. Glide Foot Sash Doesn't Slide Easily Possible Cause: Glides not engaged properly into track. Solution: Turn displaced foot until it drops into track then adjust for proper fit. Glide Adjustment Cam Sash Cannot Be Adjusted Possible Cause: Broken glide assembly. Solution: Remove sash, remove broken glide assembly, and replace. Sash Will Not Open Possible Cause: Over-rotated glide foot or foot has jumped past pin. Solution: Using a 1" wide putty knife, lift problem foot above glide rib while pulling sash open. Reposition glide foot onto track and adjust top and bottom glides to eliminate up and down movement of sash. Handle Squeaks When Turning It Possible Cause: No lubrication between parts. Solution: Remove handle from sash and disassemble by removing screw inside pivot stud (metal casing). Apply a general purpose (3 in 1 type) oil on black plastic collar between handle and base, not on washer. Reassemble and apply handle to sash. Escutcheon Plate Oil Handle 9

Lock Operates Hard Homeowner Adjustment Guide Possible Cause: Strike plate is not properly adjusted or is crooked. Solution: Loosen screws on problem strike and slide it toward the glass. Tighten screws and check operation making sure lock bolt is fully engaged into strike plate. Readjust if necessary. Strike Plate Possible Cause: Strike plate sticks out too far. Solution: Remove strike assemblies and clean out debris that might be trapped underneath. Reapply strike assembly. 10