HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

Similar documents
HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

3" [76.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

3 11/16" [94.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY 6" [152.4mm]

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

3 1/2" [88.9mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

4 1/2" [114.3mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

CRASH RAIL INSTALLATION HEIGHT

CRASH RAIL INSTALLATION HEIGHT

Please read these instructions thoroughly prior to beginning the Acrovyn Z-Clip Wall Panel installation!

Installation Instructions

Installation Instructions 800/800W/855/G2-800 Continuous Bracket Handrails

Install Instructions. SCR-48N Crash Rail. Please read these instructions thoroughly prior to beginning the SCR-48N Crash Rail installation!

Installation Instructions

Installation Instructions 3530VS/3530FVS/G2-3530VS/A3530VS HANDRAILS

Installation Instructions 3520WW/3520WWB Handrail

BSM, GSM & GSS. Joint Kit Instruction. (Modified for IMPACT) (NSF Certified) Curved Glass Fresh Meat Delicatessen and Seafood Merchandisers

Installation Instructions 2000/2000W/G Handrail

Installation Instructions 1200/1255/G Handrails International Compliant

Installation Instructions

Assembly Instructions 10 X 10 Aluminum Frame Building

Installation Instructions HR910 Handrail

WG-4 Wall Guard Installation Instructions

Two Panel Frameless Bypass Door

Installation Instructions 800/800W/855/G2-800 Handrails

INSTALLATION INSTRUCTIONS

Installation Instruction

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS Lateral Shift Accessory Model: PAC-800

3/8 FRAMELESS BYPASS SLIDING SHOWER ENCLOSURE

Installation Instructions

Track Rack. * Track Racks are not lockable

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Installation Instructions

Installation Instructions HR910 International Compliant Handrail

Assembly Instructions 10 X 10 Aluminum Roof Support

UNIT No FRAMELESS PIVOT SHOWER DOOR

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

TREX POST MOUNT DECKING AND CONCRETE

INSTALLATION INSTRUCTIONS

INOVO 2-LITE SLIDING PATIO DOOR

INSTALLATION GUIDE. 5" Balustrade System

INSTALLATION INSTRUCTIONS

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

Installation Instructions

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

NX7 SERIES 5-1/2 HANDRAIL

INSTALLATION INSTRUCTIONS

Vanity Installation Instructions

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

Assembly Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

INSTALLATION INSTRUCTIONS / DODGE RAM CREW CAB 2500/3500

PREPARATION & TOOL CHECK LIST

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

Double Beam Freestanding Pergola Installation Guide

Installation Instructions 1000/1000W/G Handrail

INSTALLATION INSTRUCTIONS

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Installation Instructions

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

Vanity Installation Instructions

Quill Stop V2 Installation Guide 11/16/2014

TREX PERGOLA INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

Original Gallery System

Salter Industries Spiral Stair

THANK YOU FOR PURCHASING FROM HERITAGE PATIOS

MTS-ACB. RENOGY Photovoltaic Module Adjustable Curved Bracket E Philadelphia St, Ontario, CA Version: 1.

INSTALLATION INSTRUCTION

Assembly Instructions

Independent Containment System (ICS)

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

Bumper Sign INSTALLATION INSTRUCTIONS

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

INSTALLATION INSTRUCTION

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

Installation Instructions

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1.

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE 1400A-1700A-1800A

MODEL AL-HD & AL-HDM INSTALLATION INSTRUCTIONS

Prepare Base Assembly. (If pump is pre-assembled on base, go to step#8.)

Desk/Wall-Mount Rack

Installation Manual for Metal Toilet Partitions Standard Series

GENERAL INSTALLATION GUIDE: WARRANTY: PRODUCT INFORMATION T F

Installation Instructions for Vista Air Vertically Folding Walls

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

Ford Pick Up Rear leaf Spring Kit Installation Instructions

FIXED MOUNTING SHUTTERS INSTALLATION

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE

RBP-1215B-RX DODGE RAM QUAD CAB RX3

Transcription:

PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION OF THIS. CONTAINED WITHIN IS THE TECHNICAL INFORMATION AND INSTALLATION TECHNIQUES REQUIRED TO COMPLETE AN EFFICIENT, NEAT AND LONG-LASTING INSTALLATION. INSPECT ALL MATERIALS FOR DAMAGE OR MISSING PARTS. IF YOU DISCOVER DAMAGED OR MISSING MATERIALS, IN THE USA PLEASE NOTIFY THE FACTORY AT (800) 233-8493, AND IN CANADA (888) 895-8955 FOR CUSTOMER SERVICE. HEIGHT PER LOCAL CODE AUTHORITY 3 1/2" [88.8mm] 6 3/8" [161.9mm] 3 3/4" [95.3mm] 5 11/32" [135.6mm] MUST BE INSTALLED IN ACCORDANCE WITH THESE INSTRUCTIONS! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY VOID ANY PRODUCT WARRANTIES AND RESULT IN AN UNSUCCESSFUL INSTALLATION. FOR SPECIFIC QUESTIONS REGARDING THE INSTALLATION OF THIS PLEASE CALL THE FACTORY IN THE USA AT (800) 233-8493 OR EMAIL IWPTECHSUPPORT@C-SGROUP.COM. IN CANADA CALL (888) 895-8955. SECTIONAL VIEW IMPORTANT NOTES 1. THIS HAS BEEN MANUFACTURED TO CUSTOMER SPECIFIED DIMENSIONS AND CAN NOT BE CUT OR MODIFIED ON SITE. TO DO SO COULD VOID THE WARRANTY. 2. ALL DIMENSIONS ARE TYPICAL. 3. FOR DRYWALL/PLASTER WALL CONSTRUCTION, IT IS RECOMMENDED FOR FASTENERS TO BE ENGAGED INTO METAL/WOOD STUDS TO MAINTAIN MAXIMUM PULLOUT STRENGTH. IF DURING INSTALLATION YOU ENCOUNTER SPECIAL WALL CONDITIONS THAT DO NOT ALLOW FOR DIRECT ATTACHMENT TO THE STUDS PLEASE CONSULT YOUR LOCAL AUTHORITY HAVING JURISDICTION. 4. INSTALL S FIRST. 5. INSTALL LONGEST RUN OF FIRST. 6. AND SPLICE SHOULD NOT EXCEED 3" [76.2mm] DISTANCE FROM A BRACKET. 7. MATERIAL MUST REACH 65 F MIN. TO 75 F MAX. 24 HOURS PRIOR TO INSTALLATION. THIS IS ESSENTIAL TO MINIMIZE EXPANSION AND CONTRACTION. 8. MAY REQUIRE USE OF FIRE PUTTY WHEN INSTALLED ON FIRE WALL WITH TOGGLE BOLTS. REFERENCE INSTRUCTIONS 24FIREPUTTY FOR FIRE PUTTY INSTALLATION. 9. THIS REQUIRES A MINIMUM OF 2 MOUNTING BRACKETS PER UNIT. THE MINIMUM -TO- LENGTH IS 12 3/4" [323.9mm]. 10. FOR MORE INFORMATION ON SEE OUR WEBSITE AT www.c-sgroup.com.

COMPONENTS & WALL FASTENERS (80M160001) (24A223xxx) (24M067xxx) ENDCAP (24S119000) FASTENER #1 1/4" LOCK WASHER (90H006003) RETAINER SPLICE BAR (24I976000) DOUBLE POST SADDLE PLATFORM BRACKET (24M993XXX) MOUNTING PLATE (90H181010) INSIDE/OUTSIDE CORNER (24S120000) FASTENER #2 1/4-20 HEX NUT (90H010001) FASTENER #3 #6-32 X 3/4" S/S PHILLIPS FLAT HEAD MS (90H811002) MOUNTING BRACKET JIG (90H222010) 6-32 NC PLUG TAP (90H226010) SPLINE (24F220000) FASTENER #4 1/4" FLAT WASHER (90H007003) MIXING NOZZLE (90M022000) EPOXY (90M089001) CAULKING GUN CONVERSION KIT SLEEVE (90M023000) CAULKING GUN CONVERSION KIT PLUNGER (90M023000) FASTENER #5 1/4-20 X 3/4" S/S HEX HEAD MACHINE SCREW (90H008006) WALL CONDITION SPECIFIED FASTENER DRILL DIAMETERS WALL RETAINER CS PART NUMBER STEEL STUD/GYPSUM WALL 1/4-20 X 3" S/S FLAT HEAD BOLT WITH TOGGLE 3/4" N/A 90H184002 CONCRETE/CONCRETE BLOCK 1/4" X 1 3/4" S/S FLAT HEAD MASONRY ANCHOR 3/16" N/A 90H390000 WOOD STUD/GYPSUM WALL #14 X 3" S/S PHILLIPS FLAT HEAD WOOD SCREW 7/32" N/A 90H538004

LAYOUT VIEW 4 1/16" [104.0mm] 1" [25.5mm] 5/8" [16.2mm] STAINLESS STEEL LENGTH 6" 3" [152.4mm] [76.2mm] 4" [101.6mm] 9/16" [14.7mm] 3" [76.2mm] MAX. FIRST BRACKET LOCATION FROM CORNER OF WALL 5/8" [15.9mm] SPLICE FASTENERS 32" O.C. MAX. [812.8mm] LAYOUT VIEW POWDER COATED LENGTH 2" [51.2mm] 3 1/2" [89.3mm] FIELD DIMENSION (TYPICAL ALL WALLS) 3" [76.2mm] 1" [25.4mm]

TYPICAL ASSEMBLY PLATFORM MOUNTING BRACKET RETAINER SPLICE BAR AND FASTENERS #1, #2, #5 SPECIFIED FASTENER 32" O.C. MAX. [812.8mm] FASTENER #3 FASTENERS #2, #4, #5 FASTNERS #2, #4, #5 FASTENERS #2, #4, #5 MOUNTING PLATE

TYPICAL ASSEMBLY ALUMINUM SPLINE APPLY ADHESIVE TO INSIDE SURFACE APPLY ADHESIVE TO INSIDE SURFACE NOTE: THIS MATERIAL HAS BEEN MANUFACTURED TO CUSTOMER SPECIFIED DIMENSIONS AND CAN NOT BE CUT OR MODIFIED ON SITE. TO DO SO COULD VOID THE WARRANTY. 1. USING "LOCAL CODE" REQUIREMENTS, ESTABLISH HEIGHT ABOVE FINISHED FLOOR. DEDUCT 3 3/4" [95.3mm] AND SNAP A CHALK LINE AT THAT HEIGHT. THIS MARKS THE LOCATION OF THE HOLE FOR THE MOUNTING BRACKET FASTENERS. REFER TO SECTIONAL VIEW. 2. DISTRIBUTE MATERIAL. MATCH THE NUMBER ON THE RAIL TO THE MARK NUMBER ON THE DRAWING. SOME LARGE RUNS REQUIRE MORE THAN ONE PIECE OF. THESE ARE NOTED WITH A MARK NUMBER AND A LETTER, I.E., 2001A, 2001B. 3. ATTACH S AND/OR INSIDE/S (A FLAT SURFACE IS REQUIRED): TO PROTECT FINISHED SURFACES FROM ADHESIVE DURING ASSEMBLY APPLY MASKING TAPE TO END OF 'S SURFACE AND ALSO TO EXTERIOR SURFACE OF (OR INSIDE/). USING 100 GRIT SANDPAPER, SAND THE INTERIOR SURFACE OF THE. CLEAN THE INTERIOR SURFACE OF WITH ISOPROPYL (RUBBING) ALCOHOL. DRY FIT THE ALUMINUM SPLINE BEFORE APPLYING ADHESIVE. THE ALUMINUM SPLINE SHOULD BE INSTALLED WITH 1" [25.4mm] OF THE ALUMINUM SPLINE PROTRUDING FROM THE END OF THE. ONCE TESTED, REMOVE AND APPLY 1/8" BEAD OF ADHESIVE TO SANDED, INTERIOR SURFACE (REFERENCE CAULKING GUN CONVERSION KIT FIGURES 3 & 4) AND PERMANENTLY ATTACH ALUMINUM SPLINE. USING 100 GRIT SANDPAPER, SAND THE INTERIOR SURFACE OF THE (OR INSIDE/). CLEAN THE INTERIOR SURFACE OF (OR INSIDE/) WITH ISOPROPYL (RUBBING) ALCOHOL. APPLY 1/8" BEAD OF ADHESIVE TO SANDED, INTERIOR SURFACE. THE ADHESIVE ONLY ALLOWS FOR 8 TO 12 MINUTES OF WORKING TIME. INSTALL (OR INSIDE/) OVER ALUMINUM SPLINE. FOR A PROPER SEAM, (OR INSIDE/) MUST BE TIGHTLY FITTED TO THE. PARTS CAN BE HANDLED IN 1-1/2 HOURS AND WILL BE FULLY CURED AFTER 24 HOURS. IF SPLICE IS REQUIRED, INSTALL BEFORE SECOND. INSTALL SECOND (OR INSIDE/) AS PREVIOUSLY DESCRIBED. USING A FLAT SURFACE, ROTATE SECOND (OR INSIDE/OUTSIDE CORNER) UNTIL PARALLEL AND PROPERLY ORIENTED.

TYPICAL ASSEMBLY MOUNTING BRACKET SPECIFIED FASTENER 32" O.C. MAX. [812.8mm] FASTENER #3 4. ATTACH MOUNTING BRACKET ASSEMBLIES (A FLAT SURFACE IS REQUIRED). REMOVE PACKAGING FROM AND S (OR INSIDE/S). USING A FLAT SURFACE, ORIENT THE (WITH S) UPSIDE DOWN. DRILL PILOT HOLES IN BOTTOM SURFACE OF AS PER MOUNTING BRACKET DRILL JIG INSTRUCTIONS (SEE FIGURE 2). MOUNTING BRACKETS ARE TO BE LOCATED AT A MAXIMUM OF 32" [812.8mm] O.C. AND NO LESS THAN 3" [76.2mm] FROM END OF. CAUTION: BE SURE THE DOES NOT ROTATE WHEN DRILLING PILOT HOLE. BEFORE DRILLING CONSECUTIVE BRACKET LOCATIONS, INSERT A #36 DRILL BIT THROUGH MOUNTING BRACKET DRILL JIG AND INTO PILOT HOLE. THIS STEP WILL HELP ENSURE DOES NOT ROTATE WHEN DRILLING FOR ADDITIONAL MOUNTING BRACKETS. A SECOND MOUNTING BRACKET DRILL JIG HAS BEEN PROVIDED TO DRILL FOR ADDITIONAL MOUNTING BRACKETS. 5. FASTEN THE TO THE WALL BRACKETS IN SUCCESSION BY INSERTING TWO (2) #6-32 X 3/4" S/S PHILLIPS FLAT HEAD MACHINE SCREWS THROUGH THE UNDERSIDE OF THE BRACKET INTO THE. 6. USE ASSEMBLED AS A TEMPLATE TO DRILL CLEARANCE HOLES IN WALL SURFACE FOR MOUNTING HARDWARE BY LINING UP MOUNTING HOLE OF MOUNTING BRACKET WITH CHALK LINE. 7. ATTACH ENTIRE ASSEMBLY TO THE WALL USING APPROPRIATE FASTENERS. CAUTION: OVER TORQUEING MAY CAUSE DAMAGE TO THREADS.

#36 DRILL BIT 6-32 NC TAP 9/64" DRILL BUSHING #36 PILOT HOLE BUSHING MOUNTING BRACKET DRILL JIG 0.7" [17.8mm] 1.4" [35.6mm] 3" [76.2mm] FIGURE 2. MOUNTING BRACKET DRILL JIG MOUNTING BRACKET DRILL JIG INSTRUCTIONS. REFER TO FIGURE 2. 1. PLACE ON A FLAT WORKING SURFACE AND ROTATE UNTIL BOTTOM OF IS FACING UPWARD. 2. POSITION DRILL JIG OVER. THE DRILL JIG'S FEET MUST SIT FLAT ON LEVEL WORKING SURFACE. LOCATE CENTER OF #36 PILOT DRILL HOLE OVER CORRESPONDING LOCATION FOR MOUNTING BRACKET ASSEMBLY. 3. DRILL A #36 PILOT HOLES IN BOTTOM OF. 4. POSITION TAP END OF MOUNTING BRACKET JIG OVER PREVIOUSLY DRILLED #36 PILOT HOLE. USE 9/64" DRILL BUSHING TO CORRECTLY THREAD PILOT HOLE WITH 6-32 NC TAP (PLUG CHAMFER TYPE RECOMMENDED).

EPOXY CARTRIDGE CONVERSION KIT PLUNGER MIXING NOZZLE EPOXY CARTRIDGE AND MIXING NOZZLE CONVERSION KIT SLEEVE FIGURE 3. OPEN END STANDARD 10 OZ. CAULKING GUN FIGURE 4. CAULKING GUN CONVERSION KIT EPOXY CARTRIDGE AND MIXING NOZZLE. REFER TO FIGURE 3. 1. REMOVE CAP AND GASKET FROM THE END OF EPOXY CARTRIDGE BY TWISTING 90. 2. INSTALL MIXING NOZZLE ON THE FRONT OF EPOXY CARTRIDGE AND LOCK IN PLACE BY TWISTING 90. CAULKING GUN CONVERSION KIT. REFER TO FIGURE 4. 1. INSERT EPOXY CARTRIDGE AND MIXING NOZZLE INTO OVAL OPENING OF SLEEVE. NOTE THE LOCATION OF OPEN END. 2. PLACE PLUNGER IN THE BACK END OF CARTRIDGE. 3. PLACE THE CONVERSION KIT, WITH MIXER NOZZLE AND EPOXY CARTRIDGE, IN A STANDARD 10 OZ CAULKING GUN AS SHOWN IN FIGURE 4. PLUNGER WILL ATTACH TO CIRCULAR PUSH PLATE ON CAULKING GUN.

TYPICAL ASSEMBLY RETAINER SPLICE BAR AND FASTENERS #1, #2, #5 FASTENERS #2, #4, #5 FASTENERS #2, #4, #5 FASTENERS #2, #4, #5 MOUNTING PLATE 8. ATTACH S AND S: SLIDE 1/4-20 X 3/4" HEX HEAD BOLTS IN THE RECEIVER SLOT OF THE RETAINER FOR ALL WALL BRACKETS. PARTIALLY FASTEN 1/4-20 X 3/4" HEX HEAD BOLTS ONTO MOUNTING PLATE (NOTE THE ORIENTATION IN DRAWING ABOVE). SLIDE HEAD OF BOLTS INTO GROOVES OF THE AND. ALIGN WITH SO THEY ARE FLUSH TOGETHER. SECURELY TIGHTEN ALL FASTENERS. 9. ATTACH TO THE WALL BRACKETS: ALIGN HEX HEAD BOLT WITH MOUNTING BRACKETS. INSERT HEX HEAD BOLT INTO THE MOUNTING BRACKET HOLE. PLACE A 1/4" FLAT WASHER AND 1/4-20 HEX NUT ONTO THE HEX HEAD BOLT. TIGHTEN AS REQUIRED. Muncy, Pennsylvania (800) 233-8493 Fax (570) 546-5169 Mississauga Ontario (888) 895-8955 Fax (905) 274-6241 www.c-sgroup.com This document is the property of Construction Specialties, Inc. and contains CONFIDENTIAL PROPRIETARY INFORMATION that is not to be disclosed to third parties and is not to be used without approval in writing from Construction Specialties, Inc.