MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

Similar documents
SECTION MANHOLES

SECTION 39 - MANHOLES TABLE OF CONTENTS

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

Standard Specifications

SECTION MANHOLES

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

STRUCTURES FOR SANITARY AND STORM SEWERS

STANDARD SPECIFICATIONS SECTION PRECAST CONCRETE 1.2 REQUIREMENTS FOR MANUFACTURERS AND SUPPLIERS BEFORE DELIVERY

SECTION PRECAST CONCRETE STRUCTURES

Pipe Product Catalog Table of Contents

Appendix C Construction Details

1. INTRODUCTION 2. REFERENCE SPECIFICATIONS. Page -1- Bonding and Grouting

Section 914. JOINT AND WATERPROOFING MATERIALS

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

STEEL PIPE GUIDERAIL 01/01/

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

ALUMINUM PIPE GUIDERAIL 01/01/

GENERAL ISOMETRIC LAYOUT

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS

PART MATERIALS. Section Fencing Materials. Description

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

4.1. Foremen 4.2. Concrete plant manager 4.3. Concrete plant operator 4.4. Personnel performing saw cutting and joint sealing

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

REQUEST FOR BIDS WELL #4 ABANDONMENT

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP TRAFFIC FLAT WALL WITH 5' x 8' OPENING

HOME STRENGTHENING GUIDE HOW TO ECONOMICALLY STRENGTHEN YOUR HOUSE AGAINST EARTHQUAKES AND HURRICANES

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following.

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

SECTION METAL FABRICATIONS

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

A. Extent of structural precast concrete work is shown on drawings and in schedules.

SECTION THERAPEUTIC POOL ACCESSORIES

CONCRETE MANHOLES.

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

Sigma Fasteners, Inc. Section 7

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

Why Do We Saw Equipment Types Matching Equipment to the Project Blade Selection Ensuring Construction Quality When Things Don t Go Right The Sawing

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Manholes Table of Contents

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

eco-shake INSTALLATION INSTRUCTION

Product Guide Specification

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 6. Published by

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

SECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting

Grease Interceptor Design Checklist

1. Architectural precast concrete cladding units.

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD.

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

Hand drilling a shallow tube-well and fitting a simple Bailer-bucket in Zimbabwe

PIPE/CONDUIT SUPPORTS

UNDERGROUND UTILITY TRENCHES AND VAULTS Page 1 of 6 ADDENDUM #1

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

Downtown Rack. Custom logo option available

Proposal PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y. Baker, MT P.O. Box 846

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings

Swerve Rack CUSTOM RACKS AVAILABLE

This addendum forms a part of the Contract Documents dated: August 10, 2012.

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

H O O P RAC K. Simple Security

"A" "A" SECTION "A-A" X-SECTION VERTICAL CURB (TYPE B) Village STREET & PAVEMENT STR-05. Engineering Department

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2

S W E RV E RAC K. Simple Security. Simple Stability.

CS3 represents manufacturers of products for use in the municipal waterworks industry.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

INSTALLATION INSTRUCTIONS

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

SECTION G ESTIMATE OF QUANTITIES

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

GOLDEN RULES FOR EASIFIX INSTALLATION

Tool 3-1 A2 Bushing 6 Check if the bushing supports (angle iron) are properly welded with the upper part of the structure pipes. welded bushing suppor

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

Product Guide Specification

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

Anti-Trust Statement

A. Suggested Tool List

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

IGGA Guide Specification: Dowel Bar Retrofit (DBR) Introduction

GENERAL INSTALLATION GUIDELINES

Transcription:

MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a precast concrete manhole base. 2) Poured in place bases will not be acceptable. 3) All precast manhole sections shall be manufactured in accordance with and meet the requirements of specification ASTM C-478, latest revision. 4) All precast manhole sections shall be manufactured by the wet cast method. 5) The minimum compressive strength of the concrete for all sections shall be 4000 psi (27 MPa). The maximum allowable absorption of the concrete shall not exceed 9 percent of the dry weight. Tests, when required, shall be in accordance with ASTM C-497, Determining Physical Properties of Concrete Pipe or Tile, latest revision. 6) Steel reinforcement for all manhole diameters shall be in accordance with ASTM C-478, latest revision. PART II: PRODUCTS A. Precast Concrete Manholes 1) Standard Manhole a) The manholes shall be constructed of precast reinforced concrete manhole sections. The sections shall be a minimum of four feet (1219 mm) in diameter for pipe sizes up to and including 20 inches (508 mm) internal diameter (for pipe sizes with an internal diameter 24 inches (610 mm) and greater, see Plans). b) The sections shall conform to the requirements of Specification for Precast Reinforced Concrete Manhole Sections (ASTM C-478, latest revision). Joints shall be sealed with a preformed plastic gasket that meets all the requirements of ASTM C-990, Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections, Butyl-Lok as manufactured by A-Lok Products Corporation, Trenton, New Jersey or D-Lok rubber gasket as specified to meet the requirements of ASTM specification C-443, as supplied by Atlantic Concrete Products Company, Tullytown, PA or an approved equal. c) Manhole Bases 1) Manhole bases shall be precast reinforced concrete. Poured in place bases will not be acceptable. 2) The bases shall be monolithically cast and shall

Manholes p.2 consist of a manhole bottom and a wall which shall extend a minimum of 10 inches (254 mm) above the top of the highest influent sewer. The top of the base section shall be carefully formed to receive the tongue of the barrel section. There shall be a minimum distance of 3 inches (76 mm) between the invert of the lowest effluent sewer and floor of the precast base to provide for the construction of a formed invert and bench wall within the manhole. No more than two lift inserts or holes shall be cast in the bases. a) All precast manhole bases shall have pipe to manhole flexible seals as manufactured by A-LOK Products Corporation Tullytown, PA., A-LOK full compression seals or an approved equal. 1) Pipe seals up to and including 20 inches (508 mm) in size shall be cast into 48 (1219 mm) diameter manhole bases. 2) 21 inch (533 mm) through 30 inch (762 mm) pipe seals shall be cast into 60 inch (1524 mm) diameter manhole bases. 3) 33 inch (838 mm) through 42 inch (1067 mm) pipe seals shall be cast into 72 inch (1829 mm) diameter manhole bases. 4) 48 inch (1219 mm) through 54 inch (1372 mm) pipe seals shall be cast into 84 inch (2134 mm) diameter manhole bases. 5) 60 inch (1524 mm) pipe seals shall be cast into 120 inch (3048 mm) diameter manhole bases. 6) Flexible pipe to manhole seals shall meet all the test and performance requirements of ASTM specification C-923, Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes and Laterals. 7) Installation of pipe to manhole flexible seals shall be made in accordance with the manufacturers suggested specifications. b) Manholes 4 feet (1219 mm) in diameter shall have a bottom at least 6 inches (152 mm) thick and a wall at least 5 inches (127 mm) thick. c) Manholes 5 feet (1524 mm) in diameter shall have a bottom at least 8 inches (203 mm) thick and a wall at least 6 inches (152 mm) thick. d) Manholes 6 feet (1829 mm) in diameter shall have a bottom at least 8 inches (203 mm) thick and a wall 7 inches (178 mm) thick. e) Manholes 7 feet (2134 mm) in diameter shall have wall at least 8 inches (203 mm) thick. f) Manholes 8 feet (2438 mm) in diameter shall have wall at least 9 inches (229 mm) thick.

Manholes p.3 g) Manholes 10 feet (3048 mm) in diameter shall have wall 10 inches (254 mm) thick. h) Manholes 12 feet (3658 mm) in diameter shall have wall 12 inches (305 mm) thick. d) Risers and Top Section 1) The top of base walls, the ends of reinforced concrete risers and the bottom ends of precast tops shall be so formed that when risers and tops are assembled with the base, they will make a continuous manhole. Joints shall be of such design as will permit effective joining and placement without irregularities in the interior wall surface of the manhole. 2) Manhole barrels shall consist of riser and top section with a minimum wall thickness of 5 inches (127 mm). The top section shall be an eccentric conical section with thickened upper walls with the smallest inside diameter equal to 24 inches (610 mm), to receive the manhole frame and cover. No more than 2 lift inserts shall be cast in each barrel or top section. B. Manhole Steps 1) Manhole steps shall be of extruded 6061-T6 aluminum or Polypropylene step #PS4B as manufactured by M.A. Industries, Peachtree City, Georgia or approved equal. 2) Manhole steps shall be cast into the walls of base, risers and conical top sections, and shall be aligned vertically and spaced so as to be on equal centers in the assembled manhole at a maximum distance apart of 12 inches (305 mm). Steps shall be located a minimum of 6 inches (152 mm) from the ends of base, riser, and top sections, and shall be securely embedded in manhole sections by mortar or cast in place polypropylene inserts. 3) Manhole step dimensions shall meet the requirements of OSHA Standard 1910.27 for fixed ladders. C. Manhole Frames and Covers 1) Casting shall be tough gray iron, free from cracks, holes, swells, and cold shuts. All manhole casting shall be made accurately to the pattern and to the dimensions shown on Plans, and shall be planed where marked, or where otherwise necessary to secure perfectly flat and true surfaces. All lids which rock and do not lie solid after construction is finished will be condemned and must be replaced by perfect lids. 2) Anchor Bolts a) Anchor Bolts for bolting manhole frame to precast or brick manholes shall be ¾ (19 mm) diameter galvanized

Manholes p.4 PART III: EXECUTION all thread steel rods with 5 inch (127 mm) hook for embedment in the manhole top and a minimum 2 inch (51 mm) projection through the bars of the frame. b) Two Bolt Slots or inserts shall be cast into the manhole top, positioned at 180 degrees at the time of manufacture. A. Precast Concrete Bases 1) All precast concrete bases shall be installed on a layer of crushed stone which shall have a minimum depth of 6 inches (152 mm). The crushed stone shall conform to the quality and grading requirements specified in Section 703.3 of the Pennsylvania Department of Transportation Specifications Form 408 for No. 1B - Type C crushed stone coarse aggregate. 2) All pipe openings shall have pipe to manhole flexible seals as previously mentioned. 3) In constructing Drop Manholes, the Contractor shall use one of the following methods: a) Encase and support the riser and incoming pipe with concrete down to undisturbed earth as shown on the Detail Sheet. The cost of this concrete shall be included in the price of the drop manhole. Encasing the riser with brick will not be acceptable. Care shall be taken to have all pipes laid to correct lines and grades before concreting is undertaken. b) Purchase precast base with a 90 degree bend precasted into the base section and protect the vertical pipe with precast Drop Collars. c) Purchase a minimum 5-0 (1524 mm) diameter manhole and run the drop inside the manhole. Internal piping to be secured by expansion bolts and stainless steel bands. B. Masonry Work 1) The top of all precast manholes may be brought to proper grade for receiving manhole frames by using not more than four courses of brick or precast concrete grade rings. Masonry construction shall be performed by experienced and qualified workmen only. All work shall be laid plumb, straight, level, square and true. Brick shall be laid in full beds of mortar and shoved into place. All joints shall be full and not more than one-half inch (13 mm) in thickness. The Contractor shall set in place and bond in the masonry all necessary steps and miscellaneous items specified elsewhere. The masonry walls shall be pargeted on the inside and outside with a one-half inch (13 mm) coat of Portland Cement mortar. 2) Mortar to be used in brickwork, setting manhole frames, and pargeting, shall be prepared by thoroughly mixing: one (1) volume of Type II Portland Cement with three (3) volumes of sand and sufficient clean water to produce a rich mass of

Manholes p.5 approved consistency. Mixing mortar on the ground or any paved surface shall not be permitted. Sand to be used in making mortar shall be clean, well-graded, and shall pass a standard No. 4 sieve. 3) All mortar to be used in joining manhole section, filling lift holes in risers shall be an approved mixture of sand, cement and Embeco aggregate. 4) Masonry shall not be constructed during cold weather (air temperature below 40 degrees F (5 C)) unless necessary precautions are observed as directed by the Engineer. C. Flow Channels and Bench Walls 1) In precast bases the flow channels and bench walls in each manhole shall be carefully formed of mortar and brick, or concrete, to 1/2 pipe section and to the dimensions indicated on the drawings. 2) The minimum depth of flow channel shall be equal to 1/2 the diameter of the pipe to which it connects. The channel shall be graded to give a smooth, uninterrupted flow through the manhole. 3) Bench walls shall be pitched a minimum of 1 inch per foot (82 mm per meter) from the inside periphery of the manhole to the edge of the flow channel. 4) The Contractor has the option to pour the flow channels or to have them precast by the manhole manufacturer. D. Manhole Frames and Covers 1) Manhole frames and covers shall be brought to proper grade as previously noted, set in ¼ (6 mm) bed of mastic, and anchored in place with the top two (2) ¾ (19 mm) diameter anchor bolts which shall be securely embedded in the top of the manhole. E. Waterproofing 1) The entire outer surface of all precast concrete manholes shall be coated with two (2) coats of an approved bitumastic coating. Coating shall be Koppers 300 M Epoxy or Pennsbury 32-B-4 Epoxy, or approved equal. 2) A pvc entry sleeve shall be installed on each manhole cone or flat slab top section to prevent surface infiltration. The sleeve shall be Water-LOK Manhole Entry Sleeve as manufactured by A-LOK Products, Tullytown, PA., or equal. PART IV: SPECIAL CONDITIONS A. Manhole liner for Sanitary Systems 1) Where indicated on the contract drawings, the manholes,

Manholes p.6 Pumping Stations and Force main manholes shall be internally lined with a corrosion resistant PVC Liner. 2) This liner shall have dove-tail ribs so it can be integrally and securely cast into the concrete structure. 3) The Liner shall be white in color in order to reflect light. 4) Liner shall be Dura-Plate 100 as manufactured by A-LOK Products, Tullytown, PA., or equal.