NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

Similar documents
A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Tools required by installer: Materials required by installer:

Installation Guide - Evolution Series Wood Siding

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

PRIMED STRAND REVERSIBLE SHAKE

DW HORIZONTAL INSTALLATION

KS42 MF SERIES - HORIZONTAL INSTALLATION

COMPOSITE SIDING INSTALLATION GUIDE

CERACLAD.

400 SERIES VERTICAL INSTALLATION

Building Wrap and Flashing

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Flashing Materials. Rough Opening Preparation

Building Wrap and Flashing

Shapes Siding. Perfection Shingles. Chalk Line

DW VERTICAL INSTALLATION

PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS

How To Install Windows: Nail-Fin Application

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

Dear Contractor, I am glad that you are interested in our window rebate program.

8 x 10 Timber-frame Garden Shed

Integrate the Window and WRB (1/2)

Eagle clad double-hung window installation instructions

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

10x10 Shed Plans and Building Guide

8x8 Shed Plans and Building Guide

KuraStone TM Installation Guide

KS SERIES - VERTICAL INSTALLATION

CFDTT-01. Control Joint Study (General)

Before installation, check your local and state requirements for this type of install.

Sun Windows General Information New Construction Hinged Door Installation Instructions

12x12 Shed Plans and Building Guide

Curtain Wall Installation Guide

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Show them you're an InstallationMaster, and watch your business grow. InstallationMasters Training Manual Addendum Level RLC-1

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

Installation Guide Classic Series Wood Siding

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

WINDOW INSTALLATION GUIDE

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e H O W B U I L D S H E D.

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

HOW TO BUILD A 12X8 SHED

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Integrity Polygon and Round Top Installation and Finishing Instructions

eco-shake INSTALLATION INSTRUCTION

6x6 Shed Plans and Building Guide

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Installation Guide for Andersen Architectural Clad Awning Windows

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

900 SERIES WALL PANELS

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

Vinyl Windows and Doors Manufactured by VPI Quality Windows

INSTALLATION INSTRUCTIONS

I n s t a l l a t i o n I n s t r u c t i o n s

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

TYPAR WEATHER PROTECTION SYSTEM TABLE OF CONTENTS. SPECIAL INSTALLATION CONSIDERATIONS Stucco** Brick** Stone Veneer** Wood Siding**

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

application instructions

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

Harvest (8094) Mystic (8078) Niagara (8095) Shenandoah (8057) 2 DURATA MORTARLESS STONE DURATA FLAT KIT PROFILE #:

Mira Premium Series Bi-Parting French Sliding Patio Door Installation Instructions

All Window Installation Instruction

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

VINYL WINDOWS (new construction or replacement) page 2. VINYL PATIO DOORS pages WOOD CLAD WINDOWS (new construction).page 5 WOOD CLAD WINDOWS

Assembled Patio Door Installation Guide 2-Panel Patio Door with Non-Welded Frame

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Installation Instructions for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

Effective February, 2015

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding

In the 30-plus years that I ve been a remodeling contractor, I ve

UNIT 5: EXTERIOR DOORS AND WINDOWS

Kinro Metal, Vinyl, Flush Mount and Recessed Fin Windows OEM INSTALLATION MANUAL

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

Transcription:

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1

GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes FOUNDATION 1.1 Foundation at Building Wall WALLS, TRANSITIONS AND BALCONIES 2.1 Through Wall Flashing 2.2 Typical Outside Corner 2.3 Typical Inside Corner 2.4 Balcony at Building Wall 2.5 Typical Balcony Edge WINDOWS and DOORS 3.1 Window - Head 3.2 Window - Jamb 3.3 Window - Sill 3.4a Window Waterproofing Sequence (1 of 10) 3.4b Window Waterproofing Sequence (2 of 10) 3.4c Window Waterproofing Sequence (3 of 10) 3.4d Window Waterproofing Sequence (4 of 10) 3.4e Window Waterproofing Sequence (5 of 10) 3.4f Window Waterproofing Sequence (6 of 10) 3.4g Window Waterproofing Sequence (7 of 10) 3.4h Window Waterproofing Sequence (8 of 10) 3.4i Window Waterproofing Sequence (9 of 10) 3.4j Window Waterproofing Sequence (10 of 10) 3.5 Sliding Door - Head 3.6 Sliding Door - Jamb 3.7 Sliding Door - Sill at Balcony 3.8 Sliding Door - Sill at Patio 3.9 Swing Door - Head 3.10 Swing Door - Jamb 3.11 Swing Door - Sill at Balcony 3.12 Swing Door - Sill at Patio ATTACHMENTS and PROTRUSIONS 4.1 Light Fixture 4.2 Electrical Box 4.3 Pipe Protrusion 4.4 Exhaust Vent 4.5 Guard Attachment at Wall Index 0.2

DISCLAIMER THE GREATEST CARE HAS BEEN TAKEN TO VERIFY ALL INFORMATION CONTAINED HEREIN. HOWEVER, EACH SITUATION IS DIFFERENT AND READERS ARE STRONGLY ADVISED NOT TO RELY SIMPLY ON THE CONTENTS OF THIS GUIDE AS IT IS NOT INTENDED TO REPLACE PROFESSIONAL ADVICE. AVIVA, ITS SUBSIDIARIES, AFFILIATES AND THOSE INVOLVED IN THE WRITING AND PUBLICATION OF THIS GUIDE ASSUME NO LIABILITY FOR ANY STATEMENTS MADE IN THIS GUIDE OR FOR ANY DAMAGE, LOSS, INJURY, OR EXPENSE THAT MAY BE INCURRED OR SUFFERED AS A RESULT OF THE USE OF OR RELIANCE ON THIS PUBLICATION. THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME BUILDING PRACTICES AND HAS BEEN REVIEWED BY A SPECTRUM OF INDUSTRY PARTICIPANTS. THE READER IS ADVISED TO EVALUATE THE INFORMATION, MATERIALS AND TECHNIQUES CAUTIOUSLY AND TO CONSULT APPLICABLE BUILDING CODES AND GUIDELINES TO DETERMINE WHETHER THE INFORMATION, MATERIAL AND TECHNIQUES ARE SUITABLE IN EACH INSTANCE. THE DRAWINGS AND TEXT ARE INTENDED AS A GENERAL REFERENCE GUIDE ONLY. PROJECT AND SITE SPECIFIC FACTORS INCLUDING CLIMATE, EXPOSURE, COMPLEXITY, AESTHETICS, ETC. MUST ALWAYS BE TAKEN INTO CONSIDERATION. LIMITATIONS THESE DETAILS ARE INTENDED AS A PRACTICAL REFERENCE GUIDE FOR ASSEMBLING A BUILDING ENVELOPE IN WOOD FRAME CONSTRUCTION ONLY. IT IS NOT INTENDED TO REPLACE PROFESSIONAL ADVICE. ENSURE THAT ALL PROPOSED PRODUCTS AND SYSTEMS ARE ACCEPTABLE TO THE BUILDING AUTHORITY HAVING JURISDICTION PRIOR TO THE INSTALLATION. ENSURE TO FOLLOW THE BUILDING MATERIAL MANUFACTURER'S WRITTEN SPECIFICATIONS & INSTALLATION GUIDELINES. THE INFORMATION PRESENTED HEREIN IS NOT EXCLUSIVE. MANY PRODUCTS AND METHODS MAY BE USED AS ALTERNATIVES TO SATISFY REGIONAL REQUIREMENTS, COST CONSIDERATIONS, AVAILABILITY AND SPECIFIC DESIGN REQUIREMENTS. ENSURE THAT MATERIALS USED IN CONJUNCTION WITH ONE ANOTHER ARE COMPATIBLE. Disclaimer & Limitations 0.3

GENERAL NOTES: 1) STRUCTURAL FRAMING REQUIREMENTS, LINTEL, POST & BEAM REQUIREMENTS AND CONCRETE STRENGTH AND MIX REQUIREMENTS ARE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. SUCH REQUIREMENTS ARE NOT IDENTIFIED ON THE ATTACHED BUILDING ENVELOPE DETAILS. 2) WINDOWS & DOORS, MECHANICAL COMPONENTS, ELECTRICAL FIXTURES AND GUARDRAILS, WHERE SHOWN ON THE ATTACHED DETAILS ARE BY OTHERS. 3) ALL WORK SHALL BE IN ACCORDANCE WITH THE BUILDING CODE, MUNICIPAL BYLAWS AND REGULATIONS. 4) ANY EXPOSED UNDERSIDE OF FLASHING AT WINDOW / DOOR HEADS TO BE PAINTED. 5) ALL WINDOWS AND DOORS MUST MEET THE REQUIREMENTS OF THE BUILDING CODE. 6) CAULKING BETWEEN DISSIMILAR MATERIALS MUST BE INSTALLED PER BUILDING CODE. CAULKING / MUST BE INSTALLED AS PER MANUFACTURER'S WRITTEN SPECIFICATIONS. 7) ATTACHMENT OF CLADDING MUST BE INSTALLED PER BUILDING CODE AND MANUFACTURER'S REQUIREMENTS. 8) INSULATION MUST BE INSTALLED PER BUILDING CODE. 9) VAPOUR BARRIER MUST BE INSTALLED PER BUILDING CODE. 10) FLASHING DIMENSIONS, SLOPE & END DAMS MUST BE PER BUILDING CODE. VERTICAL LEG OF METAL FLASHING UP WALL SHEATHING MUST EXTEND UPWARDS NOT LESS THAN 50 mm BEHIND THE AIR BARRIER / SHEATHING MEMBRANE. METAL FLASHING MUST HAVE MINIMUM OF 6 % SLOPE TOWARDS EXTERIOR. METAL FLASHING MUST OVERLAP MINIMUM OF 10 mm VERTICALLY OVER THE BUILDING ELEMENT BELOW. METAL FLASHING MUST HAVE MINIMUM OF 25 mm END DAM AT TERMINATIONS. PROVIDE MINIMUM OF 5 mm CLEARANCE BETWEEN METAL FLASHING AND SIDING. 11) MUST BE MINIMUM 3/8" X 2" CCA TREATED EXTERIOR GRADE PLYWOOD. INSTALL VERTICAL ALIGNED WITH STUDS. THE SHALL BE NAILED TO THE UNDERLYING SHEATHING USING HOT DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS, MINIMUM 50 mm (2") LONG INSTALLED AT 8" CENTERS. ACQ TREATED WILL REQUIRE STAINLESS STEEL FASTENERS OR G165 GALVANIZED FASTENERS. 12) INSTALL BUG SCREEN (RIGID OR NYLON MESH SCREEN) AT BOTTOM AND TOP OF CAVITY. NYLON BUG SCREEN, IF USED, TO BE WRAPPED AROUND ENDS OF. General Notes 0.4

EXTERIOR SHEATHING INTERIOR FINISH (DRYWALL) VAPOUR BARRIER AIR BARRIER / SHEATHING MEMBRANE LAP AIR BARRIER / INSULATION ; INSTALL MINIMUM 25 mm OVER FOUNDATION WALL AS SHOWN BUG SCREEN 25 mm SHEATHING MEMBRANE MINIMUM 25 mm OVER FOUNDATION WALL; SEAL AIR BARRIER / SHEATHING MEMBRANE CONTINUOUSLY TO FOUNDATION WALL FOAM SILL GASKET 200 mm CLEAR 10 mm CONCRETE FOUNDATION WALL GRADE PROVIDE MIN. 200 mm VERTICAL CLEARANCE DAMPROOFING / WATERPROOFING MEMBRANE Foundation at Building Wall 1.1

NOTE: 1. MUST TERMINATE AT EVERY FLOOR LEVEL. INSULATION AIR BARRIER / SHEATHING MEMBRANE FROM WALL ABOVE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE FROM WALL BELOW AND METAL FLASHING BUG SCREEN FLOOR LINE MIN. 50 mm INTERIOR FINISH (DRYWALL) SUITE VAPOUR BARRIER 5 mm CLEAR 26 Ga. PRE-FINISHED THROUGH WALL METAL FLASHING MIN. 10 mm 5 mm 6% BUG SCREEN AIR BARRIER / SHEATHING MEMBRANE AIR BARRIER / SHEATHING MEMBRANE EXTERIOR SHEATHING SUITE INTERIOR FINISH (DRYWALL) INSULATION VAPOUR BARRIER Through Wall Flashing 2.1

NOTE: 1. INSTALL TWO ADDITIONAL STRAPS TO ALL OUTSIDE CORNERS AS SHOWN. VAPOUR BARRIER INTERIOR FINISH (DRYWALL) EXTERIOR SHEATHING INSULATION AIR BARRIER / SHEATHING MEMBRANE APPLY EXTRA LAYER OF 300mm WIDE (150mm EACH FACE) AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP OVER AIR BARRIER / SHEATHING MEMBRANE TO ALL OUTSIDE CORNERS CONTINUOUS AT BUTT JOINTS FIBRE CEMENT TRIM LEAVE CAVITY BETWEEN ADJACENT PIECES OF AT ALL CORNERS 150 mm APPLY EXTRA LAYER OF AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP OVER AT ALL OUTSIDE CORNERS AS SHOWN CONTINUOUS AT BUTT JOINTS Typical Outside Corner 2.2

NOTE: 1. INSTALL TWO ADDITIONAL STRAPS TO ALL INSIDE CORNERS AS SHOWN. INTERIOR FINISH (DRYWALL) VAPOUR BARRIER LEAVE CAVITY BETWEEN ADJACENT PIECES OF AT ALL INSIDE CORNERS 150 mm AIR BARRIER / SHEATHING MEMBRANE CONTINUOUS AT BUTT JOINT APPLY EXTRA LAYER OF 300 mm WIDE (150 mm EACH FACE) AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP OVER AIR BARRIER / SHEATHING MEMBRANE TO ALL INSIDE CORNERS CONTINUOUS AT BUTT JOINT FIBRE CEMENT TRIM CONTINUOUS AT BUTT JOINT APPLY EXTRA LAYER OF AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP OVER AT ALL INSIDE CORNERS AS SHOWN EXTERIOR SHEATHING INSULATION Typical Inside Corner 2.3

EXTERIOR SHEATHING INSULATION VAPOUR BARRIER AIR BARRIER / SHEATHING MEMBRANE LAPS OVER WATERPROOF MEMBRANE; MIN. 3" TAPE / BUG SCREEN BALCONY WATERPROOF MEMBRANE; MIN. 200 mm UP WALL SHEATHING FROM THE TOP OF FINISHED BALCONY SURFACE MIN. 2% SLOPE REQUIRED MEMBRANE MIN. 200 mm UP WALL INTERIOR FINISH (DRYWALL) SUITE EXTERIOR GRADE PLYWOOD SHEATHING ON 2 X -- TAPERED SHIMS (ONE PER JOIST) SLOPED TO EDGE PER STRUCTURAL ENGINEER'S SPECS. BALCONY FRAMING PER STRUCTURAL ENGINEER'S SPECS. VENTILATED SOFFIT PANELS 5 mm CLR. BUG SCREEN AIR BARRIER/SHEATHING MEMBRANE SUITE INTERIOR FINISH (DRYWALL) VAPOUR BARRIER Balcony at Building Wall 2.4

NOTE:- 1. TOP MOUNTED GUARDRAILS ARE NOT ACCEPTABLE. 2. STRUCTURAL ENGINEER IS RESPONSIBLE FOR THE STRUCTURAL DESIGN AND INSTALLATION INSPECTION OF GUARDRAILS. ALUMINUM AND GLASS GUARD OR ALUMINUM PICKETTED GUARD; SECURE POST BASES WITH GASKETTED STAINLESS STEEL FASTENERS THROUGH POST BASE PLATES AND SPACERS AS REQ'D; FILL PILOT HOLES WITH URETHANE CAULKING; INSTALL GUARDRAILS PER STRUCTURAL ENGINEER'S SPECS. MIN. 1070 mm WATERPROOF MEMBRANE BALCONY ROUT RECESS IN PLYWOOD FOR DECK EDGE FLASHING 26 Ga. PRE-FINISHED METAL EDGE FLASHING 100 mm MAX. MIN. 2% SLOPE REQUIRED NEOPRENE PAD AT POST LOCATIONS ONLY WOOD FASCIA - PAINT GASKETTED STAINLESS STEEL FASTENERS PER STRUCTURAL ENGINEER'S SPECS. 50 mm EXTERIOR GRADE PLYWOOD SHEATHING ON 2 X -- TAPERED SHIMS (ONE PER JOIST) SLOPED TO EDGE PER STRUCTURAL ENGINEER'S SPECS. BALCONY FRAMING PER STRUCTURAL ENGINEER'S SPECS. AIR BARRIER / SHEATHING MEMBRANE 6% 1" VENTILATED SOFFIT PANELS Typical Balcony Edge 2.5

NOTES: 1. AT HEAD LEVEL - TURN METAL FLASHINGS VERTICALLY UP WALL MIN. 25 mm TO CREATE END DAMS BEHIND SIDING AT BOTH LEFT & RIGHT JAMBS. 2. REFER TO WINDOW WATERPROOFING SEQUENCE DETAIL NOS. 3.4a -3.4i. 3. HEAD FLASHING MUST EXTEND 3/8" PAST THE WINDOW JAMBS. PROVIDE SAFETY EDGE AT ALL CUT FLASHING MATERIALS. 4. HEAD METAL FLASHING MUST NOT IMPEDE THE OPERATION OF WINDOW. EXTERIOR SHEATHING AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AND METAL FLASHING BUG SCREENS 26 Ga. PRE-FINISHED METAL HEAD FLASHING COMPLETE WITH END DAMS WOOD TRIM - PAINT 10 mm 5 mm HEAD RETAINER CLIPS; SPACING, FASTENING AND DIMENSIONS AS SPECIFIED BY WINDOW MANUFACTURER 10 mm 6% 6% MIN. 50 mm VAPOUR BARRIER INTERIOR FINISH (DRYWALL) SEAL WINDOW FLANGE TO AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP WITH URETHANE CAULKING AT HEAD AND JAMBS ONLY - DO NOT SEAL WINDOW SILL FLANGE TO ALLOW FOR DRAINAGE 26 Ga. PRE-FINISHED METAL HEAD FLASHING c/w END DAMS 5 mm 1/2" SPRAY ON FOAM INSULATION WINDOW Window - Head 3.1

NOTE: 1. REFER TO WINDOW WATERPROOFING SEQUENCE DETAIL NOS. 3.4a -3.4i. EXTERIOR SHEATHING VAPOUR BARRIER 1/2" SPRAY ON FOAM INSULATION SEAL WINDOW FLANGE TO AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP WITH URETHANE CAULKING AT HEAD AND JAMBS ONLY - DO NOT SEAL WINDOW SILL FLANGE TO ALLOW FOR DRAINAGE / TAPE WINDOW SILL FLASHING COMPLETE WITH END DAMS BELOW INTERIOR FINISH (DRYWALL) INSULATION AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AND WINDOW JAMB FLANGES AT BUTT JOINTS WOOD TRIM - PAINT Window - Jamb 3.2

NOTES: 1. AT SILL LEVEL - TURN METAL FLASHINGS VERTICALLY UP WALL MIN. 25 mm TO CREATE END DAMS BEHIND SIDING AT BOTH LEFT & RIGHT JAMBS. 2. REFER TO WINDOW WATERPROOFING SEQUENCE DETAIL NOS. 3.4a -3.4i. 3. SILL FLASHING MUST EXTEND 3/8" PAST THE WINDOW JAMBS. PROVIDE SAFETY EDGE AT ALL CUT FLASHING MATERIALS. 1/2" PLASTIC HORSESHOE SHIMS AT SILL AT 6" O.C. OR AS APPROVED BY THE WINDOW MANUFACTURER WINDOW CONTINUOUS BETWEEN METAL FLASHING AND FRAME SELF ADHESIVE MEMBRANE BEHIND FLANGE; INSTALL MIN. 3" UP WINDOW JAMBS 1/2" SPRAY ON FOAM INSULATION 26 Ga. PRE-FINISHED METAL SILL FLASHING COMPLETE WITH END DAMS WOOD TRIM - PAINT 10 mm 5 mm 6% 50 mm WOOD SILL AIR BARRIER / SHEATHING MEMBRANE UNDER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP TAPE / 25 mm SELF ADHESIVE MEMBRANE UNDER WINDOW FLANGE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP BUG SCREENS EXTERIOR SHEATHING INSULATION INTERIOR FINISH (DRYWALL) VAPOUR BARRIER Window - Sill 3.3

EXTERIOR SHEATHING VERIFY SHEATHING EDGES ARE CUT FLUSH WITH FRAMES AT ALL SIDES 12" 12" MAX. CORROSION RESISTANT STAPLES ALONG TOP EDGE (ALIGNED WITH STUDS) 12" LEAVE SILL AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP (12" WIDE) UNATTACHED AT THE BOTTOM EDGE SO THAT FIELD AIR BARRIER / SHEATHING MEMBRANE CAN BE INSTALLED UNDERNEATH IT DRILL 2" Ø VENT HOLES IN EACH STUD CAVITY BELOW WINDOW SILL Window Waterproofing Sequence (1 of 10) 3.4a

APPLY SELF ADHESIVE MEMBRANE AT JAMBS AFTER SILL APPLICATION REINFORCE AT CORNERS WITH SELF ADHESIVE MEMBRANE (CORNER GUSSETS); SEAL ALL JOINTS WITH MASTIC / TAPE 3" FIRST APPLY SELF ADHESIVE MEMBRANE ON SILL 12" 3" RETURN SELF ADHESIVE MEMBRANE UP JAMB; MIN. 3" RETURN SELF ADHESIVE MEMBRANE DOWN SILL; MIN. 3" INSTALL MINIMUM OF 6" WIDE SELF ADHESIVE MEMBRANE ACROSS SILL AND DOWN FACE; MIN. 3" NOTE: 1. PRIME ALL SURFACES TO RECEIVE SELF ADHESIVE MEMBRANE PER MEMBRANE MANUFACTURER'S SPECIFICATION. Window Waterproofing Sequence (2 of 10) 3.4b

INSTALL 12" WIDE AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AT HEAD LAPPED OVER TOP OF JAMB AIR BARRIER / SHEATHING MEMBRANE STARTER STRIPS. RETURN AIR BARRIER / SHEATHING MEMBRANE MIN. 3" INSIDE THE WINDOW ROUGH OPENING INSTALL 12" WIDE AIR BARRIER / SHEATHING MEMBRANE STARTER STRIPS AT JAMBS RETURN AIR BARRIER / SHEATHING MEMBRANE INTO WINDOW ROUGH OPENING AT HEAD AND JAMBS INBOARD ROW OF STAPLES ARE TO BE PLACED WITHIN 1/2" OF ROUGH OPENING; WINDOW FLANGE MUST COVER ALL STAPLES 12" TAPE / SEAL JOINTS FOR AIR BARRIER / SHEATHING MEMBRANE CONTINUITY NOTE:- 1. INSTALL STAPLES VERTICALLY @ 6" o.c.; HORIZONTALLY TO BE ALIGNED WITH STUDS. Window Waterproofing Sequence (3 of 10) 3.4c

APPLY CONTINUOUS ON BACKSIDE OF WINDOW FLANGES AT HEAD & JAMBS; THEN INSTALL FRAME TO OPENING; APPLY FILLET CAULK TO EDGE OF WINDOW FLANGE & NAIL HOLES TO ENSURE CONTINUOUS SEAL. DO NOT INSTALL AT SILL TO PROVIDE A PATH FOR DRAINAGE. PLACE EXTRA AT MITER CORNERS OF WINDOW FRAME TYPICAL (BACKSIDE) FASTEN AT HEAD USING HEAD RETAINER CLIPS PER MANUFACTURER'S SPECIFICATION 12" NAILING OF WINDOWS TO BE PER WINDOW MANUFACTURER'S RECOMMENDATIONS; APPLY OVER NAILS PLASTIC HORSESHOE SHIMS AT SILL AT 6" O.C. OR AS APPROVED BY THE WINDOW MANUFACTURER Window Waterproofing Sequence (4 of 9) 3.4d

INSTALL 26 Ga. PRE - FINISHED METAL HEAD FLASHING COMPLETE WITH END DAMS (25 mm) - SEE NOTE 1 NOTE:- 1. DIMENSIONS OF HEAD METAL FLASHING MUST NOT IMPEDE THE OPERATION OF WINDOW. HEAD FLASHING MUST EXTEND 3/8" PAST THE WINDOW JAMBS. Window Waterproofing Sequence (5 of 10) 3.4e

A TUCK BOTTOM SHEET OF AIR BARRIER / SHEATHING MEMBRANE UNDER THE AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP TAPE BETWEEN AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AND AIR BARRIER / SHEATHING MEMBRANE FOR AIR BARRIER CONTINUITY Window Waterproofing Sequence (6 of 10) 3.4f

TAPE ALL JOINTS FOR AIR BARRIER CONTINUITY TAPE / SEAL AIR BARRIER / SHEATHING MEMBRANE OVER WINDOW JAMB FLANGES & OVER HEAD METAL FLASHING C B B AIR BARRIER / SHEATHING MEMBRANE NOTE: INSTALLATION SEQUENCE: A,B,C A AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AT SILL Window Waterproofing Sequence (7 of 10) 3.4g

INSTALL 26 Ga. PRE - FINISHED SILL METAL FLASHING COMPLETE WITH END DAMS (25 mm) - SEE NOTE 1 VERTICAL - ALIGN WITH STUDS NOTE: 1. SILL FLASHING MUST EXTEND 3/8" PAST THE WINDOW JAMBS. Window Waterproofing Sequence (8 of 10) 3.4h

INSTALL 26 Ga. PRE-FINISHED METAL HEAD FLASHING OVER AND WINDOW HEAD TRIM AS SHOWN INSTALL WOOD TRIMS OVER AS SHOWN VERTICAL - ALIGN WITH STUDS NOTE:- 1. HEAD FLASHING MUST EXTEND 3/8" PAST THE WINDOW HEAD TRIM. Window Waterproofing Sequence (9 of 10) 3.4i

SEAL BETWEEN FLASHING END DAMS AND TRIM CAULK ALL BUTT JOINTS BETWEEN WOOD TRIM & SIDING PER MANUFACTURER'S SPECIFICATIONS & GUIDELINES CAULK GAP BETWEEN WINDOW JAMB & WOOD TRIM PER MANUFACTURER'S SPECIFICATIONS & GUIDELINES CAULK GAP BETWEEN WINDOW SILL & SILL FLASHING PER MANUFACTURER'S SPECIFICATIONS & GUIDELINES - INSTALL IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS AND SPECIFICATIONS AND PER BUILDING CODE NOTE:- 1. HEAD FLASHING MUST EXTEND 3/8" PAST THE WINDOW HEAD TRIM. Window Waterproofing Sequence (10 of 10) 3.4j

NOTES: 1. AT HEAD LEVEL - TURN METAL FLASHINGS VERTICALLY UP WALL MIN. 25 mm TO CREATE END DAMS BEHIND SIDING AT BOTH LEFT & RIGHT JAMBS. 2. HEAD FLASHING MUST EXTEND 3/8" PAST THE DOOR JAMBS. PROVIDE SAFETY EDGE AT ALL CUT FLASHING MATERIALS. EXTERIOR SHEATHING AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AND METAL FLASHING BUG SCREENS 26 Ga. PRE-FINISHED METAL HEAD FLASHING COMPLETE WITH END DAMS WOOD TRIM - PAINT HEAD RETAINER CLIPS; SPACING, FASTENING AND DIMENSIONS AS SPECIFIED BY DOOR MANUFACTURER 10 mm 5 mm 10 mm 6% 6% MIN. 50 mm VAPOUR BARRIER INTERIOR FINISH (DRYWALL) SEAL DOOR FLANGE TO AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP WITH URETHANE CAULKING AT HEAD AND JAMBS ONLY - DO NOT SEAL DOOR SILL FLANGE TO ALLOW FOR DRAINAGE 26 Ga. PRE-FINISHED METAL HEAD FLASHING c/w END DAMS 1/2" SPRAY ON FOAM INSULATION SLIDING DOOR Sliding Door - Head 3.5

VAPOUR BARRIER 1/2" SPRAY ON FOAM INSULATION SEAL DOOR FLANGE TO AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP WITH URETHANE CAULKING AT HEAD AND JAMBS ONLY - DO NOT SEAL DOOR SILL FLANGE TO ALLOW FOR DRAINAGE SLIDING DOOR SILL FLASHING c/w END DAMS EXTERIOR SHEATHING INTERIOR FINISH (DRYWALL) INSULATION AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AND DOOR JAMB FLANGES AT BUTT JOINTS WOOD TRIM - PAINT Sliding Door - Jamb 3.6

NOTES: 1. AT SILL LEVEL - TURN METAL FLASHINGS VERTICALLY UP WALL MIN. 25 mm TO CREATE END DAMS BEHIND SIDING AT BOTH LEFT & RIGHT JAMBS. 2. SILL FLASHING MUST EXTEND 3/8" PAST THE DOOR JAMBS.. SLIDING DOOR WATERPROOFING MEMBRANE; MIN. 200mm UP DOOR JAMBS FROM TOP OF FINISHED BALCONY SURFACE BALCONY 24 Ga. PRE-FINISHED METAL SILL FLASHING C/W END DAMS WATERPROOF MEMBRANE UNDER DOOR FRAME AS SHOWN - CREATE SIDE & BACK DAMS MIN. 2% SLOPE REQUIRED 1/2" CLEAR 1/4" CLEAR MIN. 3" SHIMS AS PER DOOR MANUFACTURER'S SPECS CONTINUOUS 3/4"x1"x1/8" CONTINUOUS ALUMINUM ANGLE - SEE DETAIL 'A' SUITE CORROSION RESISTANT FASTENERS @ 12" O.C.; PATCH OVER EACH FASTENER HEAD WOOD SILL BASE BOARD VAPOUR BARRIER BALCONY FRAMING PER STRUCTURAL ENGINEER'S SPECS. EXTERIOR GRADE PLYWOOD SHEATHING ON 2 X -- TAPERED SHIMS (ONE PER JOIST) SLOPED TO EDGE PER STRUCTURAL ENGINEER'S SPECS. AIR BARRIER/SHEATHING MEMBRANE 1" DETAIL 'A' NTS 3/4" Sliding Door - Sill at Balcony 3.7

NOTES: 1. AT SILL LEVEL - TURN METAL FLASHINGS VERTICALLY UP WALL MIN. 25 mm TO CREATE END DAMS BEHIND SIDING AT BOTH LEFT & RIGHT JAMBS. 2. SILL FLASHING MUST EXTEND 3/8" PAST THE DOOR JAMBS.. SLIDING DOOR PATIO WATERPROOFING MEMBRANE; MIN. 8" UP DOOR JAMBS FROM TOP OF FINISHED PATIO SURFACE 24 Ga. PRE-FINISHED METAL SILL FLASHING C/W END DAMS WATERPROOF MEMBRANE UNDER DOOR FRAME AS SHOWN - CREATE SIDE & BACK DAMS MIN. 2% SLOPE REQUIRED 1/2" CLEAR MIN. 2" SHIMS AS PER DOOR MANUFACTURER'S SPECS CONTINUOUS 3/4"x1"x1/8" CONTINUOUS ALUMINUM ANGLE - SEE DETAIL 'A' SUITE CORROSION RESISTANT FASTENERS @ 12" O.C.; PATCH OVER EACH FASTENER HEAD WOOD SILL BASE BOARD VAPOUR BARRIER 3/4" 1" DETAIL 'A' CONCRETE TOPPING / FINISHED SURFACE NTS Sliding Door - Sill at Patio 3.8

NOTES: 1. AT HEAD LEVEL - TURN METAL FLASHINGS VERTICALLY UP WALL MIN. 25 mm TO CREATE END DAMS BEHIND SIDING AT BOTH LEFT & RIGHT JAMBS. 2. HEAD FLASHING MUST EXTEND 3/8" PAST THE DOOR JAMBS. PROVIDE SAFETY EDGE AT ALL CUT FLASHING MATERIALS. EXTERIOR SHEATHING AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP & METAL FLASHING 6% 26 Ga. PRE-FINISHED METAL HEAD FLASHING COMPLETE WITH END DAMS 10 mm 5 mm MIN. 50 mm VAPOUR BARRIER INTERIOR FINISH (DRYWALL) INTERIOR FINISH (DRYWALL) BUG SCREEN AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP TRIM WOOD TRIM - PAINT 26 Ga. PRE-FINISHED METAL HEAD FLASHING COMPLETE WITH END DAMS BRICK MOLD - PAINT 10 mm 6% BUG SCREEN SWING DOOR Swing Door - Head 3.9

WOOD TRIM - PAINT BRICK MOLD - PAINT AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP SWING DOOR TRIM AT BUTT JOINTS EXTERIOR SHEATHING AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP INSULATION VAPOUR BARRIER INTERIOR FINISH (DRYWALL) Swing Door - Jamb 3.10

NOTES: 1. AT SILL LEVEL - TURN METAL FLASHINGS VERTICALLY UP WALL MIN. 25 mm TO CREATE END DAMS BEHIND SIDING AT BOTH LEFT & RIGHT JAMBS. 2. SILL FLASHING MUST EXTEND 3/8" PAST THE DOOR JAMBS. PROVIDE SAFETY EDGE AT ALL CUT FLASHING MATERIALS. SWING DOOR, CASING & THRESHOLD WATERPROOFING MEMBRANE; MIN. 200 mm UP DOOR JAMBS FROM TOP OF FINISHED BALCONY SURFACE SUITE SEE DETAIL 'A' 24 Ga. PRE-FINISHED METAL SILL FLASHING COMPLETE WITH END DAMS WATERPROOF MEMBRANE UNDER DOOR FRAME AS SHOWN - CREATE SIDE & BACK DAMS BALCONY MIN. 2% SLOPE REQUIRED 1/2" CLEAR 1/4" CLEAR 3" CURB. FRAMING WOOD SILL - PAINT VAPOUR BARRIER BALCONY FRAMING PER STRUCTURAL ENGINEER'S SPECS. EXTERIOR GRADE PLYWOOD SHEATHING ON 2 X -- TAPERED SHIMS (ONE PER JOIST) SLOPED TO EDGE PER STRUCTURAL ENGINEER'S SPECS. 24 Ga. PRE - FINISHED METAL SILL FLASHING (INSTALL MIN. 2" UP JAMBS); ADHERED WITH SILICONE AT SILL & WITH CORROSION RESISTANT FASTENERS AT JAMBS AIR BARRIER/SHEATHING MEMBRANE CONTINUOUS 3/4" X 1" X 1/8" ALUMINUM ANGLE CORROSION RESISTANT FASTENERS @ 12" O.C.; PATCH OVER EACH FASTENER HEAD WOOD SILL - PAINT SHIMS @ 6" o.c. Swing Door - Sill at Balcony WATERPROOF MEMBRANE UNDER DOOR FRAME AS SHOWN - CREATE SIDE & BACK DAMS DETAIL 'A' NTS 3.11

NOTES: 1. AT SILL LEVEL - TURN METAL FLASHINGS VERTICALLY UP WALL MIN. 25 mm TO CREATE END DAMS BEHIND SIDING AT BOTH LEFT & RIGHT JAMBS. 2. SILL FLASHING MUST EXTEND 3/8" PAST THE DOOR JAMBS. PROVIDE SAFETY EDGE AT ALL CUT FLASHING MATERIALS. SWING DOOR, CASING & THRESHOLD WATERPROOFING MEMBRANE; MIN. 200 mm UP DOOR JAMBS FROM TOP OF FINISHED PATIO SURFACE CORROSION RESISTANT FASTENERS @ 12" O.C.; PATCH OVER EACH FASTENER HEAD CORROSION RESISTANT FASTENERS @ 12" o.c.; PATCH OVER EACH FASTENER HEAD PATIO WATERPROOFING MEMBRANE; MIN. 3/8" BACKDAM 24 Ga. PRE-FINISHED METAL SILL FLASHING COMPLETE WITH END DAMS MIN. 2% SLOPE REQUIRED 1/2" CLEAR 1/4" CLEAR MIN. 2" 3/4" X 1" X 1/8" ALUMINUM ANGLE - SEE DETAIL 'A' WOOD SILL VAPOUR BARRIER CONCRETE TOPPING / FINISHED SURFACE 3/4" 1" DETAIL 'A' NTS Swing Door - Sill at Patio 3.12

VAPOUR BARRIER AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AND SELF ADHESIVE MEMBRANE EXTERIOR SHEATHING INSULATION ALLOW CAVITY TO DRAIN AROUND SIDES OF BLOCKING; HOLD UP 1" FROM TOP OF BLOCKING SELF ADHESIVE MEMBRANE LAPS OVER LIGHT PLATE FLANGE SURFACE MOUNT FIXTURE HOUSING TO WALL WITH CORROSION RESISTANT FASTENERS; FILL PILOT HOLES WITH POLYURETHANE CAULKING LIGHT FIXTURE A VINYL LIGHT TRIM PLATE (MATCH SIDING COLOUR) BACK CAULK TOP AND SIDES TO AIR BARRIER / SHEATHING MEMBRANE - INSTALL WEATHERPROOF GASKET BETWEEN FIXTURE AND TRIM PLATE ELECTRICAL BOX TAPE / NOTE: 1. LIGHT FIXTURE PROFILE MAY VARY. 4" ELEV. 'A'. 2nd 3rd PRESSURE TREATED SOLID BLOCKING; SLOPE TOP EDGE 2:1 TO ASSIST DRAINAGE SELF ADHESIVE MEMBRANE OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP TUCK AIR BARRIER / SHEATHING MEMBRANE UNDER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP 18" 1st 2nd LIGHT PLATE FLANGE SELF ADHESIVE MEMBRANE INSTALLATION SEQUENCE - 1st 2nd 3rd 18" SQUARE OF AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP Light Fixture 4.1

NOTE: 1. ELECTRICAL BOX PROFILE MAY VARY. 3" MIN. S. A. MEMBRANE VAPOUR BARRIER B SELF ADHESIVE MEMBRANE AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP STARTER INSULATION EXTERIOR SHEATHING AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AND S.A. MEMBRANE AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP VINYL MOUNTING PLATE BUG SCREEN SELF ADHESIVE MEMBRANE PRIMED TO ELECTRICAL BOX ELEV. 'B' 3rd BOX 1st 2nd 12+" TYP. 12+" TYP. ELECTRICAL SERVICE BOX EXTENSION AND WEATHERPROOF COVER SELF ADHESIVE MEMBRANE OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP BUGSCREEN ALL AROUND TUCK AIR BARRIER / SHEATHING MEMBRANE UNDER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP TAPE / Electrical Box 4.2

NOTE: 1. EXTEND HOSE BIBS AS NECESSARY TO CLEAR BACKER PLATE AND. VAPOUR BARRIER INSULATION EXTERIOR SHEATHING AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP AND GASKET AIR BARRIE / SHEATHING MEMBRANE STARTER STRIP BEHIND GASKET VINYL PIPE BACKER PLATE WITH LOCKING TRIM RING PIPE EPDM OR RUBBER GASKET SEALED TO WALL AND PIPE; LAP AIR BARRIER / SHEATHING MEMBRANE OVER GASKET AT TOP & UNDER GASKET AT BOTTOM AT PERIMETER TUCK AIR BARRIER / SHEATHING MEMBRANE UNDER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP PRESSURE TREATED SOLID BLOCKING GASKET OVER AIR BARRIER/ SHEATHING MEMBRANE STARTER STRIP TAPE / Pipe Protrusion 4.3

INSULATION EXTERIOR SHEATHING 6% AIR BARRIER / SHEATHING MEMBRANE LAPS OVER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP, SELF ADHESIVE MEMBRANE & METAL FLASHING S. A. MEMBRANE LAPS OVER VENT FLANGE BUG SCREEN 26 Ga. PREFINISHED METAL FLASHING c/w END DAMS FRESH AIR INTAKE - WALLCAP COMBO VENT W/DRIP FLANGE BY PRIMEX OR APPROVED EQUAL C SEAL TO DUCT 26 Ga. METAL 'J' TRIM; SEAL BETWEEN 'J' TRIM AND SIDES OF VENT BUG SCREEN TUCK AIR BARRIER / SHEATHING MEMBRANE UNDER AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP TAPE / VAPOUR BARRIER SELF ADHESIVE MEMBRANE VENT FLANGE VENT HOOD VENT 18" x 18" SQUARE OF AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP ELEV. 'C'. SEAL FLANGE TO AIR BARRIER / SHEATHING MEMBRANE STARTER STRIP WITH CAULKING ALL 4 SIDES; SEAL ANY EXPOSED FASTENERS Exhaust Vent 4.4

VAPOUR BARRIER INSULATION EXTERIOR SHEATHING AIR BARRIER / SHEATHING MEMBRANE TAPE / SEAL ALL AROUND THE S.A. MEMBRANE NOTE: ALLOW FOR DRAINAGE OF CAVITY AROUND BLOCKING URETHANE BEHIND FASTENERS STAINLESS STEEL, GASKETTED FASTENERS; FILL PILOT HOLES WITH URETHANE ; DO NOT OVERTIGHTEN & COMPRESS SIDING INSTALL ALUMINUM AND GLASS GUARD OR ALUMINUM PICKETTED GUARD C/W GASKETTED STAINLESS STEEL FASTENERS PER STRUCTURAL ENGINEER'S SPECIFICATIONS 100 mm MAX. CLR. PRESSURE TREATED WOOD BLOCKING AT FASTENERS LOCATION PER STRUCTURAL ENGINEER'S SPECS. APPLY 8" SQUARE SELF ADHESIVE MEMBRANE OVER AIR BARRIER / SHEATHING MEMBRANE (c/w MASTIC ALONG TOP EDGE & SIDES) Guard Attachment at Wall 4.5