Laser Confocal Fluorescent Microscope

Similar documents

Quality Performance, Innovative Design

Things to check before start-up.

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Zeiss 780 Training Notes

Microscopy from Carl Zeiss

Practical work no. 3: Confocal Live Cell Microscopy

Leica SP8 TCS Users Manual

Leica TCS SP8 Quick Start Guide

Operating Instructions for Zeiss LSM 510

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Lecture 20: Optical Tools for MEMS Imaging

b. Turn the power switch and key to on position for blue laser.

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

ScanArray Overview. Principle of Operation. Instrument Components

Guide to Confocal 5. Starting session

Leica TCS SP8 Quick Start Guide

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

LSM 780 Confocal Microscope Standard Operation Protocol

Zeiss LSM 880 Protocol

Nikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.

ZEISS LSM510META confocal manual

Olympus LEXT OLS 4000 Confocal Laser Microscope

Leica SP8 TCS Users Manual

LSM 510 Meta Training Notes

LSM 710 Confocal Microscope Standard Operation Protocol

Cell Biology and Bioimaging Core

TRAINING MANUAL. Olympus FV1000

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

Model SU3500 Scanning Electron Microscope

Standard Operating Procedure

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

Zeiss 880 Training Notes Zen 2.3

Supplemental Method Information Zeiss LSM710

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

INTRODUCTION We believe that every laboratory working in the field of nanotechnology needs an SEM, therefore we would like to introduce to you our IEM

KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017)

Leica SPEII confocal microscope. Short Manual

LSM 510 Training Notes

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Zeiss LSM 780 Protocol

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Renishaw InVia Raman microscope

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Microscopic Structures

Scanning electron microscope

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Title: Leica SP5 Confocal User Manual

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Quick Start Guide. Leica SP5 X

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

RENISHAW INVIA RAMAN SPECTROMETER

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

1 Set up the confocal light path for imaging a green dye (Alexa488-EGFP). For example, the

Basic Users Manual for Tecnai-F20 TEM

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Operating Checklist for using the Scanning Electron Microscope, JEOL JSM 6400.

OPERATING INSTRUCTIONS

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

SECONDARY ELECTRON DETECTION

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

Quick Operation Guide

Scanning electron microscope

RAITH e-line OPERATING INSTRUCTIONS

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

(Refer Slide Time: 00:10)

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

Instructions for easyscan Atomic Force Microscope

Manufacturing Metrology Team

Be aware that there is no universal notation for the various quantities.

End-of-Chapter Exercises

Rotary Fixture M/V/X CLASS LASER SYSTEMS. Installation and Operation Instructions

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

SEM Training Notebook

Fluorescence Imaging of Single Spins in Nitrogen-Vacancy centers using a Confocal Microscope. Advanced Lab Course University of Basel

Brightfield Microscopy and Image Acquisition on Spotcam1. by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

1. Preliminary sample preparation

Scanning Electron Microscopy SEM. Warren Straszheim, PhD MARL, 23 Town Engineering

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Instructions for Tecnai a brief start up manual

A Laser-Based Thin-Film Growth Monitor

Contents. Introduction

Scanning Electron Microscopy

Transcription:

Laser Confocal Fluorescent Microscope Olympus Fluoview FV10i-LIV Laser Light Source: Ultraviolet/Visible light LD lasers - 405nm (18mW), 473nm (12.5mW), 635nm (10mW), 559nm Scanning: 2 galvanometer scanning mirrors Pixel size: 256 256-1024 1024 Scanning speed: 1.1 s / frame (for pixel size 512 512, High Speed scanning mode) Focusing scanning: High frame rate scan by Y- direction interlace scanning ( 1, 2, 4) Dimension: XYT, XYZ, XYZT Rotation scanning: 0-359.9 in 0.1 increments Detection: Fluorescence: 2 channels Phase Contrast: 1 channel

Analog integration detection by Photomultiplier Single motorized pinhole. Pinhole diameter: ø50-800μm automatic setting (adjustable to 1.0, 1.5, 2.0, and 2.5) Optical zoom: 10 objective: 1 6 in 0.1x increments and 60 objective: 1 10 in 0.1x increments Automatic Exposure Focus: Z-drive motorized focus with minimum increment: 0.01μm Objectives: exclusively designed 10 phase contrast objective NA 0.4 (equivalent to UPLSAPO 10x) Exclusively designed 60 phase contrast water-immersion objective NA 1.2 (equivalent to UPLSAPO 60 W) Remote switching from software by electric revolver Automatic detection of cover glass thickness and automatic setting of motorized correction collar. Automatic detection of interface between specimen and cover glass by laser reflection light detection Manual oil supply for 60x lens. As supporting mechanism, automatic moving of XY stage to oil supply position when switching to 60x Motorized XY stage module by stepping motor Minimum increment: 0.3μm Specimen Holder: Only the dedicated specimen holder can be mounted For three glass bottom dishes with 35mm diameter For a single cover glass chamber with 8 wells For a single glass slide or well slide with 8 wells Culture pod (for a glass bottom dish with 35mm diameter) XY Stage Environment: Temperature: 37+0.1 C,0.5 Humidity: more than 90% CO2 concentration: 5% (recommended)

Controller: Dedicated controller PC/AT-compatible OS: Windows Vista Business, 32 bit CPU: Intel Core2Duo 3.0GHz RAM: 2GB 2 DVD-Multi drive built-in 24 inch LCD monitor x 1, WUXGA (1920x1200) Image acquisition mode: map image, one shot, time-lapse (XYT), Z-stack (XYZ), Z- stack time-lapse (XYZT), multi area time-lapse (Multi Area XYT), multi area Z- stack time-lapse (Multi Area XYZT) Software: Automatic setting for fluorescence channel and laser according to dye selected from list Automatic selection of map image of 3 3 9x9 fields according to 10 objective lens, and manual selection of map acquisition area Image display by channel, overlaid channels display, image in progress review Save file formatted as OLYMPUS image format (OIF, OIB), Multi-TIFF format (8/16 bit grey scale, index color, 24/32/48 bit color), JPEG, BMP, TIFF Image editing using pseudo color setting, contrast adjustment, Comment: inputting graphic, text, scale etc., image extraction, combination 3D image construction: alpha Blend method, Maximum intensity projection method, 3D animation display, free orientation of cross section display Room Environment: 18-28 C 30-80% (non-condensing) humidity

LCFM Diagram Excitation pinhole Unused Light Dichroic Mirror (Bean Splitter) Laser Light Laser light source (4 possible wavelengths) Galvanometer scanning mirrors Lens Point of interest 2 lasers can emit at one time. Both laser beams will act the same, but each will be treated by a different galvanometer scanning mirror. This diagram shows one laser beam. Sample Fluorescent light from sample Objective Photomultiplier Pinhole Confocal Plane Detector This is the lens on the machine. It is where the laser light source will come from that the sample is exposed to. Within the machine you can find the dichroic mirror and the galvanometer. This is the objective and the detector part of the machine. It will let in light, process it, and send it out to the computer monitor as our image

1. A Laser provides high energy excitation light. 2. The laser s directed through an excitation pinhole that splits the beam. 3. Next, the light goes through a dichroic mirror (beam splitter) to separate out unneeded light and refocus the necessary light. 4. The light is focused by a lens onto a point of interest on the galvanometer mirror that is associated with a specific point on the sample 5. The light is then focused to a point on the galvanometer scanning mirror, which rasterizes an image in that region. 6. Then the light is refocused through another lens onto the sample. 7. The fluorophores in the sample are then excited and emit fluorescence. The fluorescent light is emitted through the objective. 8. That fluorescent light goes through a pinhole confocal plane and a photomultiplier before it is able to be recorded by the detector. Only the light that is able to go through the pinhole is detected, thus allowing us to view only single points of our sample, creating a 2D image. This method is useful when imaging specific sections/depths of a sample. This microscope allows for much more specificity when imaging a sample; as well as provides information about the chemical makeup of a material. However, there is a greater risk of photo bleaching due to the higher intensity energy that is entering the system. The photomultiplier allows us to adjust the sensitivity of light absorption for specific wavelengths so that we can attain high quality images.

74.247 μm

Aspex EXplorer Performance Specifications: Particle detection efficiency greater than 95% Particle detection range 30nm to 5mm Detectors SED, Quad BSED, SDD EDX Accelerating voltage 0.2 to 25 kev Continuous High vacuum and variable pressure EDX Resolution 135 ev

X-ray production and detection during SEM operation. The white circle represents the atom s nucleus. The thin white rings represent electron shells. The thick yellow circles represent electrons. The thin yellow circles represent electron holes. The green circle represents an x-ray photon Electrons penetrate the lower energy shells of the atom Low energy electrons are ejected from their shell out of the atom resulting in an electron hole. An electron from a higher energy shell drops down to a lower energy shell to fill the void During this process of moving from a higher energy to a lower energy state the electron emits an x-ray photon Bombarding electrons penetrate the surface atom s lower electron shells ejecting other electrons and creating holes in the process. These shells are then filled by higher energy electrons which create X-ray energy as a byproduct of their migration. The EDS system determines the elements present in the sample by detecting the energy levels of emitted X-rays and counting the number of x-ray photons detected at that energy level. Combining this data with the known characteristic energy value that each element emits when bombarded with electrons we are able to determine the composition of the sample.

SEM Diagram A beam of electrons is generated by the electron gun. This beam goes through condenser lenses that focus the beam down to the desired diameter on the sample s surface. The focused beam then hits the sample causing the different reactions that allow us to produce an image. Either electrons are displaced creating secondary electrons and X-rays, or the bombarding electrons bounce off the surface of the sample. This information is recorded and is used to generate an image. The angles and velocities from which certain particles have been detected are the primary piece of data that can be analyzed and converted into a topographic image. Backscattered electrons are used for an image s contrast because the intensity of the signal being recorded from the electrons depends on the angle between the incident beam and the sample surface. So the resolution is limited by the wavelength of an electron. If the beam is able to penetrate into a feature we will likely see that feature due to the backscattered electrons. But once we get to a certain small size we will see less electron able to permeate into a feature, which will not yield any backscattering from that feature and thus no image. Two characteristic interactions can occur once an electron hits the surface of the sample. The interaction can be either elastic or inelastic. Elastic interactions occur when the beam hits the sample and there is a change in direction but not in the energy level of the electron. These are called backscattered electrons. These penetrate the sample and are affected by subsurface features, thus they cannot yield very high resolution images. Inelastic interactions occur when an electron hits the orbital of an atom and ejecting another electron that was weakly bonded, these are called secondary electrons. Secondary electrons are created near the surface of the sample and thus provide a lot of information of the finer details on a sample s surface, yielding a high resolution image. These inelastic interactions can also occur with photons. An electron will hit an atom which causes it to become excited and emit x-rays which can then be detected. X-rays are used for chemical analysis because the magnitude of an X-ray is dependent upon the type of material that produces it.

AFM Cantilever Tip

Beetle Limb

304 Stainless Steel

NBS SRM 115 ANSI 316 Stainless Steel Calibration Standard Sample Bombarding electrons penetrate the surface atom s lower electron shells ejecting other electrons and creating holes in the process. These shells are then filled by higher energy electrons which create X-ray energy as a byproduct of their migration. The EDS system determines the elements present in the sample by detecting the energy levels of emitted X-rays and counting the number of photons detected at that energy level. Combining this data with the known characteristic energy value that each element emits when bombarded with electrons we are able to determine the composition of the sample. These peaks represent the composition of the sample material. The x axis represents the energy level, in kev, of the detected photons. The y axis represents the number of photons detected at different energy levels. Higher peaks mean a greater concentration of that atom. On this graph we can see that iron has the highest peak and makes up roughly 60.0% of the samples composition. This makes sense for the 316 stainless steel sample, which typically has an iron composition of 61.995 72%. All other elements measured in this sample are within a reasonable range of the actual composition of 316 stainless steel. http://www.vcbio.science.ru.nl/en/fesem/eds/ http://www.matweb.com/search/datasheet.aspx?matguid=5edc39d3b0fd44efa9fdd90d049c3737&ckck=1

The Nanosurf EasyScan 2 AFM Specifications: Electronics Spectroscopy modes: single point measurements or multiple measurements along a vector Scan speed: up to 60ms / line at 128 data-points / line Spectroscopy data points: up to 2048 Display Line graph, color map, 3D view and various others charts of the scan data can be displayed simultaneously XY resolution <.5um Modules Imaging modes include dynamic force (intermittent contact, etc.), const. amplitude (topography), const. height (amplitude), static force (contact), const. force (topography), const. height (deflection)

Atomic Force Microscope Piezoelectric xyz scanning Mirror Laser Diode Laser Light Focusing Lens Oscillating cantilever Laser light deflected by cantilever Photodiode detector Sample Surface AFM Apparatus Cantilever and Laser Diode Stage Vibration Isolation

AFM functionality is fairly easy to understand. At its core the AFM is simply recording the changes in the interactions between the AFM tip and sample of which it is imaging. First, the AFM will touch down on the surface of the sample. At this point a laser diode emits a beam on the cantilever which reflects back to the photo-detector, which acts as the base angle from which topography and surface amplitude can be measured. Next, in the software the user has to select the size of the area on the sample that they want to image. Once the area has been set, the oscillating cantilever will go line by line over the selected area. The AFM tip is so small that it is able to detect the changes in the atomic forces as it moves over the sample. These changes will change the orientation of the cantilever. That change in orientation will change the angle of deflection of the laser, which is recorded by the photo detector. During this entire imaging process the cantilever is measuring two things. First is the angle of laser deflection which helps us determine the surface topography of the sample. The second is the actual motion of the cantilever, which helps us determine the surface amplitude of the sample. So at every single point on the sample the AFM will be mapping the change in the z direction of the probe, giving us the depth of the sample at a given point, and detecting the angle of deflection by the laser off of the cantilever. In the end, we have not actually taken any sort of optical image. Instead we have a set of data, that when combined, can yield topographic, amplitude and 3D images of your sample.

Microstructure Canals Amplitude View Topographic View 3D View Color Coded Topographic View

Microstructure Square Grid Amplitude View Topographic View 3D View Color Coded Topographic View

Amplitude View CD Microstructure Topographic View 3D View (Inversed) Color Coded Topographic View

Bruker DektakXT Specifications: Measurement Technique: Stylus profilometry (contact measurement) Measurement Capability: Two-dimensional surface profile measurements; Optional three-dimensional measurement/analyses Sample Viewing Digital magnification, 0.275 to 2.2mm vertical FOV Stylus Sensor Low Inertia Sensor (LIS 3) Stylus Force 1 to 15mg with LIS 3 sensor Low Force Option N-Lite+ Low Force with 0.03 to 15mg (optional) Stylus Options Stylus radius options from 50nm to 25_m; High Aspect Ratio (HAR) tips 10_m x 2_m and 200_m x 20_m; Custom tips available upon request

Sample X/Y Stage Manual 100mm (4 in.) X/Y, manual leveling; Motorized 150mm (6 in.) X/Y, manual leveling Sample R-Theta Stage Manual, continuous 360 degrees; Motorized, continuous 360 degrees Computer System 64-bit multi-core parallel processor, Windows 7.0; Optional 23in. flat panel display Software Vision64 Operation and Analysis Software; Stress Measurement; Microform; Optional: Stitching; 3D Mapping; 3D Stress Vibration Isolation Vibration isolation solutions available Scan Length Range 55mm (2in.); 200mm (8in.) with scan stitching capability Data Points Per Scan 120,000 maximum Max. Sample Thickness 50mm (1.95in.) Max. Wafer Size 200mm (8in.) Step Height Repeatability <5Å, 1sigma on 0.1μm step Vertical Range 1mm (0.039in.) Vertical Resolution 1Å max. (@ 6.55_m range) Input Power 100 240 VAC, 50 60Hz Temperature Range Operating Range, 20 and 25 C (68 to 77 F) Humidity Range _80%, non-condensing System Dimensions and Weight 455mm W x 550mm D x 370mm H (17.9in. W x 22.6in. D x 14.5in. H); 34kg (75lbs.); Enclosure: 550mm L x 585mm W x 445mm H (21.6in. L x 23in. W x 17.5in. H); 5.0kg (11lbs.)

Profilometer Linear Variable Differential Transducer Pivot Profilometer Stylus Sample Surface The profilometer s stylus is attached to the core of the LVDT. Around the core are displacement transducers that have equal voltages in opposition yielding a net voltage of zero. As the stylus moves across the sample surface it causes this core to move up or down. This change in magnetic fields generates flux which causes a voltage. Based on the variation and the changes in voltages the machine can then determine the height of a feature. The profilometer rasters and image line by line, allowing it to create a 3D image by combining all of the line scans.

Vinyl Record

Sputter Coater Deposition Thickness Investigation We took a 2.5 cm x 7.5 cm glass slide and sputter coated it with gold for 11 minutes. We then took a needle and made scratches along the slide at different distances from the edge. Below are the results from the profilometer. In Image 1 you can see the initial results. We can see that the entire data set curves, which indicates curvature in the glass slide. From this data we can also see how the thickness of gold is changing as we approach the center of the glass slide. Image 2 is this same information but leveled out so that we could analyze that data easier. There is approximately a 20nm standard deviation with the data. Image 1 Image 2

Thickness (Angstroms) The graph below shows the results from the profilometer. It shows that as we move closer to the center of the slide the thickness of gold deposited by the sputter coater decreases. This is likely due to the fact that during sputter coating the bombarding particles are directed at the center of the gold target which causes the gold particles to fall in a cone shape. This is why we see a greater concentration of particles near the edge of the glass slide compared to the center. 1400 1200 Distence from Edge of Slide vs Thickness of Deposited Gold 1000 800 600 400 200 0 0 0.5 1 1.5 2 2.5 3 3.5 4 Distance From Edge of Slide (cm)

Fluoview fv10i specifications. (n.d.). Retrieved from Work Cited http://www.olympusamerica.com/seg_section/product.asp?product=1064&p=215&sub=2&c=6

NORTH SEATTLE COMMUNITY COLLEGE Standard Operating Procedures Olympus Fluoview FV10i Confocal Microscope Prepared by: Anton Leitner 6/7/2013

Startup Procedure: 1. Turn on the Fluoview Confocal Microscope Press and hold power button The red light will begin flashing green and the second light will stay a solid orange After about 10 minutes both lights will remain a solid color, and the machine is ready to use

2. Turn on the computer tower 3. Log in to computer (The password is always the same as the user name) Username: fluoview Password: fluoview 4. Insert Sample into the microscope stage (Look to Section 2)

5. Open imaging program FV10i-SW.exe 6. Sign in to program User ID: Administrator Password: Administrator

Sample Stage Preparation: 1. Gather necessary resources For small cylindrical sample holders For glass slides Sample Locks Hold sample firmly in place Sample Site Where the sample is held on the stage during imaging Oil deposition site where oil is deposited before using the 60x Objective Stage key Used to align to microscope when inserting stage

2. Place sample into sample site on the stage For small cylindrical sample holders place the sample onto the sample site and lock it in with the sample locks For glass slides, place sample into sample site so that the area you are interested in imaging is located near the 3 marker on the stage (this is good practice because the machine will start imaging at this center point). Ensure that the cover slip side of the glass slide is facing down away from you. One aspect is absolutely essential; you must make sure that your cover slip has a height equal to or less than a #1.5 cover slip, otherwise you run the risk of damaging the sample and the instrument. Once slide is in place, secure it in place by using the sample locks.

3. Open microscope hood and insert stage Hood open button Align the stage key hole with the cylindrical piece of metal on the microscope that fits inside it. They will line up and snuggly fit together. Close the hood, and now the sample is ready to be imaged

Dye Selection: 1. Select Set From Dye Data Base tab, near the top left of the yellow highlighted window above. 2. Identify the type of dye of which the sample is stained. If no dye is given, select a wavelength of light that is known to excite fluorophores in that sample. If that information is unknown then you will first test the four basic excitation wavelengths provided (Blue, Green, Red and FarRed). 3. Select a dye name on the list and then click Apply The dye name will now be registered on the Selected Dyes list (denoted by the green highlighted window in the image above) No more than four and at least two wavelengths must be selected before imaging can begin. 4. Click Start, near the bottom center of the screen (denoted by the red highlighted window in the image above).

Acquisition of Map Image: 1. Select dyes for mapping When 3 or more dyes have been selected then you must choose a combination of two for the initial image mapping. Click on the combination you want and then click OK at the bottom of the window.

2. Select container of interest For glass slides, the number on the stage of which you have already placed the glass slide corresponds to the container number. Whichever container, indicated by the light grey box in the image to the left, is selected will be the container that is mapped. You can look at other parts of the glass slide by switching containers, or you can click register to mark down all the containers that you would like to map. Use the Delete button to remove registered containers.

3. Start map acquisition In this window you can adjust the brightness of your map image Under the Scanning Order section you can select to either image the current container, containers that you have registered, or you can manually pick out the sections of the container that you would like to image. If you chose to manually select sections then you simply double click on the acquisition screen inside one of the large squares and the machine will raster that site. You are now ready to acquire the map image. Click Start located at the bottom left of this window.

4. During map acquisition Once you have clicked start you will see a progress bar on the bottom of the screen, which indicates the machine is conducting autofocus and auto brightness. Once the progress bar disappears, the map image acquisition will begin. It is at this point that you can manually select the boxes for the machine to raster if Manual was selected. At any time you can click Stop. If you find the feature that you re looking for and want to move on, or if you see some mistakes and want to move back. Stop can be an excellent time saver, allowing you to move forward or backward in the imaging process whenever you like.

5. Before we move on: Look to the section of the window indicated by the green square above. In this area you can select the channels that the image is being displayed on. By turning these channels on and off you will see very different images and features. Try turning off the phase contrast first. If most of your image is in phase contrast then it means you need to select a new set of dyes that will cause the sample to fluoresce, unless your primary concern is a phase contrast image. When you re ready to move on click NEXT, indicated by the red box on the image above. DO NOT CLICK Start or you will have to start this acquisition process over.

Observation Window Layout: The highlighted sections of this window are explained on the following pages 1 2 3 5 6 7 8 4

1. This window is the image map created during the previous steps. In this window you can navigate your way around your sample in order to find the points of interest. Double click anywhere on the image to focus the lasers at that point. Use the channel buttons above the image to adjust which wavelength you are observing. Use the Zoom bar on the side to identify important features first. You do not want to waste time using the laser to look around your image; it is a slow process and it can damage your sample. Use the container selection tool, located at the very top of this window, to change the container, and thus area of the slide, of which you are observing.

2. This is one of the most important features to utilize during the imaging process. This is the Repeat button which determines the rate at which the microscope rasters an image. At 1x the machine rasters at a standard speed and yields much clearer images. When you set it to 4x the image is generated much quicker but the resolution is poor. This tool is used to locate and isolate features that you want to image, so the raster speed does not effect your final image. However, the raster speed does have an effect on the rate of photobleaching of the sample. A quicker rastering speed means more passes by the laser over the area of interest. More passes means more excitation which inevitably leads to photobleaching, resulting in an unimagable section of your sample. 3. In this area you can select the channels that the image is being displayed on. By turning these channels on and off you will see very different images and features. When multiple dyes were selected you can only have two activated at one time during image observation. As you switch between lasers an image is generated that combines all the different channels into a single image.

4. This is the area of observation. As you move around the map image you will see this image change (Make sure Reapeat is ON). Each square represents a different wavelength being recorded. The bottom right square combines all other images into one. By adding and removing channels you will affect individual squares that are associated with those channels, and you will alter the combined image. Again, this will not effect your final image capture. By clicking and dragin within these squares you can move the focus of the laser which alows for precise feature alignment. 5. This section affects the depth of focus and the magnification being used. By clicking on the 10x button you will activate the 60x magnification. If 60x magnification is activated, click on the button to change it back to 10x magnification. Look to 60x Lens Oil Deposition section bfore changing magnification. By clicking Drop Oil you will prepare the 60x lense for oil deposition. By sliding the bar, located at the very bottom, you will either zoom in or out at the lasers point of focus.

7. Depth Tab AF arrow indicates the point of autofocus. If you slide this arrow up and down you will change the depth of focus, being able to see the top and bottom of a feature. End and Start bars are used to take stacks of images. Stacks can be used to generate 3D images. 6. Other Parameter Tab Use Image Size menu to choose the desired size for saved images. Higher resolution means a much larger file size and a much longer image acquisition period. Speed & Quality is responsible for image quality. We will typically always see this on High Quality Confocal Aperture affects the size of the aperture. Smaller aperture means less light is being captured. We typically want to see this set at x1.0

7. Sensitivity Tab This tab is used to change the sensitivity of the machine to specific lasers being emitted onto the sample. A higher sensitivity means the machine will detect more photons at that wavelength. This feature can be useful when isolating areas of interest on the sample. 8. Laser Tab This tab is used to change the intensity of specific lasers being emitted onto the sample. A higher intensity means more photons of that wavelength are being emitted. Be careful not to have these too high. High energy lasers can cause easy photobleaching effects and other sample damage.

60x Lens Selection and Oil Deposition: 1. Look to Area 5 on the Observation Window Layout 2. Click on the 10x button 3. A window will pop up saying Please replenishes objective lens with oil 4. Open the microscope hood 5. Look to the sample stage and find the oil deposition site

6. Take the vial of Olympus brand oil. Push the fluid out until the bubbles in the shaft are gone and a small drop is at the tip. Wipe this drop off on a tissue as shown below 7. Push another drop out onto the tip and gently place it on the oil deposition site, do not touch the lens with the plastic vial. 8. Close the hood, press ok, and now you are ready to image at 60x magnification.

Basic 2D Image Observation and Acquisition: (Reference image acquisition window layout) 1. In Area 1 use the map image to locate an area on your sample that you would like image. 2. Use the Repeat button in Area 2 to start generating an image. The image will appear in Area 4 3. Use the channel buttons in Area 3 to isolate specific wavelengths that are of interest. 4. Area 4 will contain the images from all channels. Click and drag your mouse around this area to move around the sample. 5. Use the focus bar in Area 5 to zoom up on the feature of interest. Use the 10x button if you would like a deeper zoom. Reference 60x lens oil deposition section before changing the magnification. 6. In Area 6 select the Other Parameter tab and change the image size to 1024x1024. Change Speed & Quality to High Quality. Change the Confocal Aperture to x1.0 Use the depth tab if you would like to change the depth of focus.

7. In Area 7 adjust the sensitivity and the laser intensity. There is no formula for this. Use simple trial and error to find the best possible image quality. Before you re ready to save, go back to Area 2 and turn the repeat to 1x. This will give you a good idea of what the final saved image will look like. 8. Area 8 is relatively straightforward. There are two lines. The first asks you to select a save location. The second line asks for the file name. Series Start is only used during 3D image acquisition. One Shot is used when only taking a single image. When you re ready to image click One Shot and move away from the computer to avoid vibrations. It may take a few minutes depending on some of the settings

Basic 3D Image Observation and Acquisition: (Reference image observation window layout) 1. In Area 1 use the map image to locate an area on your sample that you would like image. 2. Use the Repeat button in Area 2 to start generating an image. The image will appear in Area 4 3. Use the channel buttons in Area 3 to isolate specific wavelengths that are of interest. 4. Area 4 will contain the images from all channels. Click and drag your mouse around this area to move around the sample. 5. Use the focus bar in Area 5 to zoom up on the feature of interest. Use the 10x button if you would like a deeper zoom. Reference 60x lens oil deposition section before changing the magnification. 6. In Area 6 First select the Other Parameter tab and change the image size to 1024x1024. Change Speed & Quality to High Quality. Change the Confocal Aperture to x1.0 Adjust the End and Start bars located under the Depth tab in Area 6. These are the z-stack markers. For a complete

3D image you will want to move these markers to the highest and lowest points of the observed feature. Once you find a place where you can barely make out the feature then you have reached one of these extremes, so click the Set button to anchor that marker in place. Adjust the Step section. More steps mean a more complete image, but a longer imaging period. Fewer steps is quicker, but will only image a limited number of slices between the two specified heights and thus the resolution will not be as good. Look to the Time & Number section located right below Area 7. As you adjust the max/min points and change the number of steps you will see the timeframe change. Often your image quality will be limited to the amount of available time you have to take images. 7. In Area 7 adjust the sensitivity and the laser intensity. There is no formula for this. Use simple trial and error to find the best possible image quality. Before you re ready to save, go back to Area 2 and turn the repeat to 1x. This will give you a good idea of what the final saved image will look like.

8. Area 8 is relatively straightforward. There are two lines. The first asks you to select a save location. The second line asks for the file name. Series Start is only used during 3D image acquisition. When you re ready to image click Series Start and move away from the computer to avoid vibrations. The machine will begin taking images between the two specified points. You will know how long it takes by looking at the Time & Number section.

Image Editing: 1. Open Editing Program FV10-ASW 3.1 2. Sign in to program User ID: Administrator Password: Administrator 3. You will now see this window

4. Navigate the Explore window and locate where you saved your image. Double click on it to open it. 5. You will now see a window like this

6. Using the toolbar b c d a a) The orange highlighted area is the channel select bar. Turning these channels on and off has the same effect as it does when acquisitioning an image. Only the wavelengths selected will be displayed. b) The red highlighted arrow button opens the 2D control panel. Features in this window have not been thoroughly explored, so as far as image editing goes it will entail a lot of trial and error.

c) The green highlighted rainbow button with the scale on it opens the LUT window. In this window you have the freedom to color your image in any way. Each channel has its own set of RGB settings, and each of those has their own sub-settings. Image editing is preferential, and this window allows you to cater your images to your own style. There is no define method for maximizing image quality here, so trial and error will be your primary tool to maximize the quality. d) The pink highlighted button with the pencil on it is the basic shapes tool bar. Here you can draw a number of different shapes. Our primary concern in this toolbar is the Scale feature and the Text feature. Click on the giant A near the top of the toolbar. It will ask you to specify the location of the text. Once you ve clicked somewhere a window opens where you can write your text Click on the ruler at the bottom of the toolbar. Once selected just click and drag across the area where you want the scale bar to go

7. Saving your image Right click on the screen to pull up the available saving options. Clicking Save and Save As will save only the image. Anything you added to it will not be saved. Clicking on either either of the Export buttons will allow you to save the image as you have edited it and in various formats. Clicking Save Display will capture whatever is on the image screen at that time

3D Image Editing: All the previous editing techniques can also be applied to 3D images 1. When you open a 3D image you will see a slightly different window. Two boxes in the top right corner will now be highlighted. The box to the left opens 3D Animation. This takes your entire stack of images and creates a slideshow that makes them appear as one rotating image The box to the right combines all the images into a 3D rendering for further editing. After clicking the right box your window will look like the one below. In this view you can click and drag around the image to rotate it 360 degrees in any direction. In this view you also have access to the 3D control panel and the 3D image settings, and you can access these panels the same way as you did in the 2D view. In the 3D Control Panel try switching between the two rendering modes, both will give you a unique image. In the 3D Image Settings window go to the Image tab and try adjusting the resolution with the slide bar. This usually helps increase the image quality

2. Right click on the image to open up more settings. We are mainly concerned with the scale bar. Write down the dimensions of you feature. When converting back to a 2D image the scale does not carry over, and so you will have to manually create a scale bar. 3. Once you have oriented and edited your image the way you like, go to the top left of the 3D window. You will see a button the shows a box turning into a square, this is the 3D to 2D button. Once you have converted your image to 2D, it behaves the same way as all other 2D images, with one small difference. If you try and add a scale bar now, it will only give you dimension in pixels. There is a pixel to distance conversion, but all aspects of the image quality must be known. This is why we must manually create a scale bar using the scale bar function and the text function

Item Supplier Item Number Price #1.5 Cover Slips VWR 48366-227 $21.68 1oz Confocal Supplies Order Quantity Order Location https://us.vwr.com/store/catalog/product.jsp?catalog_number=48366-227 https://us.vwr.com/store/catalog/product.jsp?catalog_number=52846- Lens Cleaning Tissues VWR 52846-001 $49.87 600 Sheets 001 Light-Duty Tissue Wipers VWR 82003-820 $5.15 280 Sheets https://us.vwr.com/store/catalog/product.jsp?product_id=4613634 Nitrile Gloves VWR 82026 $19.82 100 Gloves https://us.vwr.com/store/catalog/product.jsp?catalog_number=82026-423 Olympus Immersion Oil Type-F Sparkle Lens Cleaner Olympus Contact Olympus Direct Home Depot 50104 $6.47 30cc phone: 1-800-455-8236 email: Nicolas.George@olympus.com visit: http://www.olympusamerica.com/oil http://www.homedepot.com/p/sparkle-4-oz-bottle-optical-lens- Cleaner-50104/203261409#.Ua-2uUCsiSo

Olympus Technician: Tim Murphy Email: timothy.murphy@olympus.com Instrument Model: FV10C-O3 Serial Number: 2B08862

Anton Wolfe Leitner 7728 21 st Ave NE Seattle, Washington, 98115 206.409.2883 aleitner29@gmail.com Skills Various Photolithography Techniques (UV, X-Ray, E-beam) Silicon Wafer Preparation (Cleaning, Surface Oxide Treatment, Spin Coating) Wet and Dry Resist Stripping Techniques Etch-Back and Lift-Off Etching Techniques Chemical Vapor Deposition Scanning Electron Microscopy EDX Material Characterization Sputter Coating Profilometry AFM Microscopy Statistical Data Analysis Confocal Microscopy AutoCAD for Mechanical and Electrical Building Design Education North Seattle Community College Seattle, Wa Nanotechnology Associate Degree of Applied Science expected 2013 Clvl GPA: 3.7 Member of Vice President s/dean s list Professional Experience Rushing Company, Seattle, WA January 2012 - Present Administrative Assistant Manage day to day administrative operations such as filing, document formatting, preparing company credentials for potential clients, routine maintenance, and office organization Preparing standard operating procedures for various devices around the office such as large document printers, airflow meters, multimeters and CO2 detectors. Maintain wireless network functionality by establishing and monitoring network drives, running frequent scans, addressing connectivity issues and setting up phones lines. Handle clients, vendors and support personnel while they are in the office.

Provide support to all other employees in the office for whatever they may need by learning new information and techniques in order to complete a task for which I had no previous knowledge. UW Department of Bioengineering, Seattle, WA April 2013 - Present Lab Assistant Assisted in synthesizing various solutions Used fluorescent microscope to conduct experiments Gather, analyze and present data Use AutoCAD to create experimental apparatuses UW Electrical Engineering Department, Seattle, WA January 2012 March 2012 Lab technician Developed photo-detectors and micro-fluidic chemical mixing chambers in a research oriented environment Utilized silicon wafer preparation, photolithography techniques, CVD, sputter coating, etching techniques and profilometry Approximately 30 hours of lab experience in this cleanroom Rushing Company, Seattle, WA January 2008 September 2009 Mechanical and electrical systems drafter Interpreted engineering hand drawn schematic designs into a mechanical or electrical digital format building schematics for use during the construction process. Happily worked under the pressure of a deadlines Utilized AutoCAD to create the 3D digital format building schematics Managed a group of 3 fellow trainees in order to define our objectives and develop a path to meet those objectives. Activities SHINE (Seattle Hub for Industry-driven Nanotechnology Education), 2010 Present Developed experiments that catered to the various audiences to which we presented (elementary school through high school levels) Interacted with the audience in order to convey a clear message that could be easily understood Practice presentation techniques and etiquette Seattle s Austrian Club, 2004 Present Help prepare large gatherings by soliciting information from our members Cooked for large gatherings