Three-phase monitoring relay CM-PVE

Similar documents
Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PBE

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Three-phase monitoring relay

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-SDS.22

Liquid level monitoring relay CM-ENS.2x

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDD.22

Three-phase monitoring relays Product group picture

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-TGD.22

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Table of contents

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-D 12/2.1

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Thermistor motor protection relays

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

CP-E range Benefits and advantages

Power supply CP-D 24/4.2 Primary switch mode power supply

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

CP-T range Product group picture

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Primary switch mode power supplies Product group picture

Thermistor motor protection relays

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

CP-T range Benefits and advantages

Pluggable interface relays CR-U Universal relays

Control module CP-A CM

Power supply CP-E 24/0.75

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Control module CP-A CM

Electronic timer CT-SDE

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/2.5

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-D 24/1.3

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

Liquid level monitors and controls

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Analog signal converters CC-E I/I

Subject to changes 11/2003 Page 1/7

Analog signal converters CC range

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Moeller Electric Corporation

Signal converters Index

Transcription:

Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012 Characteristics Monitoring of three-phase mains for phase failure, over-and undervoltage With or without neutral monitoring Device with neutral monitoring can also be used to monitor single-phase mains Powered by the measuring circuit 1 n/o contact 25 mm (0.89 in) width 1 LED for the indication of operational states Order data Three-phase monitoring relays Type Rated control supply voltage = measuring voltage Neutral monitoring Order code CM-PVE 3 x 320-460 V AC, 185-265 V AC yes 1SVR550870R9400 CM-PVE 3 x 320-460 V AC no 1SVR550871R9500

Functions Operating controls 1 Indication of operational states R: yellow LED Relay status 1 2CDC 251 006 S0012 Application / operating mode The CM-PVE is designed for use in three-phase mains for monitoring the phase parameter phase failure as well as overand undervoltage. The CM-PVE with neutral monitoring is also suitable for monitoring single phase mains. For this, all three external conductors (L1, L2, L3) have to be jumpered and connected as one single conductor. The CM-PVE works according to the closed-circuit principle. 2 - Three-phase monitoring relay CM-PVE Data sheet

Function descriptions / diagrams Phase failure monitoring Applying control supply voltage begins the fixed start-up delay t S. When t S is complete and all phases are present with correct voltage, the output relay energizes and the yellow LED R glows. If a phase failure occurs, the output relay deenergizes instantaneously and the LED R turns off. As soon as the voltage returns to the tolerance range t S starts again. After t S is complete, the output relay re-energizes automatically and the LED R glows. Over- and undervoltage monitoring Applying control supply voltage begins the fixed start-up delay t S. When t S is complete and all phases are present with correct voltage, the output relay energizes and the LED R glows. If the voltage to be monitored exceeds or falls below the fixed threshold value, the output relay de-energizes after the fixed tripping delay t V is complete and the LED R turns off. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %, t S starts again. After t S is complete, the output relay re-energizes automatically and the LED R glows. CM-PVE with neutral monitoring L1, L2, L3, N Umax Umax - 5 % Measuring value Umin + 5 % Umin 13-14 R: yellow LED t s t v <t s t s <t v t v t s t s = Start-up delay fixed 500 ms t v = Tripping delay fixed 500 ms 2CDC 252 047 F0203 CM-PVE without neutral monitoring L1, L2, L3 Umax Umax - 5 % Measuring value Umin + 5 % Umin t s t v <t s t s <t v t v t s 13-14 R: yellow LED t s = Start-up delay fixed 500 ms t v = Tripping delay fixed 500 ms 2CDC 252 048 F0203 Data sheet Three-phase monitoring relay CM-PVE - 3

Electrical connection L1, L2, L3, (N) Control supply voltage = measuring L1 L2 L3 L1 L2 L3 voltage 13-14 Output contact - closed-circuit principle L1 L2 L3 13 L1 L2 L3 13 N N 13 14 14 1SVC 110 000 F0112 13 14 14 1SVC 110 000 F0113 Connection diagram CM-PVE with neutral monitoring Connection diagram CM-PVE without neutral monitoring 4 - Three-phase monitoring relay CM-PVE Data sheet

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Type CM-PVE 1) CM-PVE Supply circuit = measuring circuit L1, L2, L3, N L1, L2, L3 Rated control supply voltage U s = measuring voltage 3 x 320-460 V AC, 185-265 V AC 3 x 320-460 V AC Rated control supply voltage U s tolerance -15...+10 % Rated frequency 50/60 Hz (-10...+10 %) 1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured. Measuring circuit L1, L2, L3, N L1, L2, L3 Monitoring functions Phase failure J J Over- / undervoltage J J Interrupted neutral J - Measuring ranges 3 x 320-460 V AC, 185-265 V AC 3 x 320-460 V AC Thresholds U min fixed 185 V / 320 V fixed 320 V U max fixed 265 V / 460 V fixed 460 V Hysteresis related to the threshold value fixed 5 % Response time 80 m Accuracy within the temperature range iu m 0.06 % / C Timing circuit Start-up delay T s fixed 500 ms (w20 %) Tripping delay T v at over-/undervoltage fixed 500 ms (w20 %) User interface Indication of operational states Relay status R: yellow LED V output relay energized Output circuits Kind of output 13-14 relay, 1 n/o contact Operating principle closed-circuit principle 2) Rated operational voltage U e Minimum switching voltage / Minimum switching current Maximum switching voltage / Maximum switching current Rated operational current I e AC-12 (resistive) at 230 V 4 A AC rating (UL 508) Mechanical lifetime AC-15 (inductive) at 230 V DC-12 (resistive) at 24 V DC-13 (inductive) at 24 V Utilization category (Control Circuit Rating Code) max. rated operational voltage max. continuous thermal current at B 300 max. making/breaking apparent power at B 300 250 V 24 V / 10 ma see Load limit curves 3 A 4 A 2 A B 300 pilot duty; general purpose 250 V, 4 A, cos phi 0.75 300 V AC 5 A 3600/360 VA 30 x 10 6 switching cycles Electrical lifetime AC-12, 230 V, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve short-circuit protection n/c contact n/o contact 10 A fast-acting 10 A fast-acting 2) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold. Data sheet Three-phase monitoring relay CM-PVE - 5

General data MTBF on request Duty time 100 % Dimensions see Dimensional drawings Weight net weight 1SVR 550 870 R9400 0.069 kg (0.152 lb) 1SVR 550 871 R9500 0.066 kg (0.146 lb) gross weight 1SVR 550 870 R9400 0.080 kg (0.176 lb) 1SVR 550 871 R9500 0.078 kg (0.172 lb) Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Degree of protection housing IP50 terminals IP20 Electrical connection Connecting capacity fine strand with wire end ferrule 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) Stripping length Tightening torque fine strand without wire end ferrule rigid 2 x 1-1.5 mm 2 (2 x 18-16 AWG) 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) 10 mm (0.39 in) 0.6-0.8 Nm (5.31-7.08 lb.in) Environmental data Ambient temperature ranges operation -20...+60 C storage -40...+85 C Damp heat IEC/EN 60068-2-30 40 C, 93 % RH, 4 days Vibration withstand IEC/EN 60068-2-6 10-57 Hz: 0.075 mm 57-150 Hz: 1 g Isolation data Rated insulation voltage U i between all isolated circuits 400 V Rated impulse withstand voltage U imp between all isolated circuits 4 kv, 1.2/50 µs Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 60947-5-1, EN 50178 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kv / 8 kv) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m) electromagnetic field electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kv / 5 khz) surge IEC/EN 61000-4-5 Level 4 (2 kv L-L) conducted disturbances, IEC/EN 61000-4-6 Level 3 (10 V) induced by radio-frequency fields Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B 6 - Three-phase monitoring relay CM-PVE Data sheet

Technical diagrams Load limit curves V V 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 194 F0205 V V 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 193 F0205 AC load (resistive) DC load (resistive) F 1.0 0.9 0.8 0.7 0.6 Switching cycles 250 V resistive load 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Derating factor F for inductive AC load 2CDC 252 192 F0205 Switching current [A] 2CDC 252 148 F0206 Contact lifetime Data sheet Three-phase monitoring relay CM-PVE - 7

Dimensions in mm and inches 88.5 3.48 81 3.19 22.5 0.886 78 3.07 78.5 3.09 2CDC 252 189 F0005 Further documentation Document title Document type Document number Electronic relays and controls Catalog 2CDC 110 004 C02xx You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Electronic relays and controls -> Measuring and monitoring relays. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls. 8 - Three-phase monitoring relay CM-PVE Data sheet

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 112 190 D0201 (03.2017) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2017 ABB All rights reserved