Three-phase monitoring relay

Similar documents
Three-phase monitoring relay

Three-phase monitoring relay CM-PBE

Three-phase monitoring relays

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Three-phase monitoring relay CM-PVE

Electronic timer CT-SDD.22

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-TGD.22

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-SDE

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-SDS.22

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Three-phase monitoring relay CM-PFS

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MFS.21

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Product group picture

Power supply CP-E 24/0.75

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Three-phase monitoring relays Table of contents

Power supply CP-D 24/1.3

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Liquid level monitoring relay CM-ENS.2x

Control module CP-A CM

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Control module CP-A CM

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Type CP-S, CP-C & CP-A Switch mode

Analog signal converters CC-E I/I

Thermistor motor protection relays

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-D 12/2.1

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Power supply CP-T 24/40.0 Primary switch mode power supply

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-T 24/10.0 Primary switch mode power supply

Thermistor motor protection relays

Power supply CP-T 48/5.0 Primary switch mode power supply

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Analog signal converters CC range

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-T 48/20.0 Primary switch mode power supply

Subject to changes 11/2003 Page 1/7

Power supply CP-T 24/20.0 Primary switch mode power supply

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Power supply CP-D 24/4.2 Primary switch mode power supply

Liquid level monitors and controls

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Primary switch mode power supplies Product group picture

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Moeller Electric Corporation

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

CP-T range Product group picture

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Signal converters Index

CP-E range Benefits and advantages

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

CP-T range Benefits and advantages

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic measuring and monitoring relays CM-range

Transcription:

1SR 550 870 F9400 Features Monitoring of three-phase mains for phase failure, over- and undervoltage Device with possibility of neutral monitoring available Device with suitability for monitoring single-phase mains available Powered by the measuring circuit 1 n/o contact 1 LED for status indication Approvals R: yellow LED - relay status A D K E L UL 508, CAN/CSA C22.2 No. GOST CB scheme CCC RMRS Marks a b CE C-Tick Order data Type Rated control supply voltage = measuring voltage Neutral monitoring Order code 3x320-460 AC, 185-265 AC yes 1SR 550 870 R9400 3x320-460 AC no 1SR 550 871 R9500 Application The are used to monitor supply voltages for over- and undervoltage and phase failure. The with neutral monitoring is also suitable for monitoring single-phase mains. For this, all three external conductors (L1, L2, L3) have to be jumpered and connected as one single conductor. Operating mode Signalling is displayed by means of the front-face LED. LED Function Output contact closed R: yellow LED ABB

Function descriptions/diagrams Function diagram legend G Control supply voltage not applied / Output contact open / LED off B Control supply voltage applied / Output contact closed / LED glowing Phase failure monitoring Applying control supply voltage begins the fixed start-up delay t S. When t S is complete and all phases are present with correcoltage, the output relay energizes and the yellow LED R glows. If a phase failure occurs, the output relay de-energizes instantaneously and the LED R turns off. As soon as the voltage returns to the tolerance range t S starts again. After t S is complete, the output relay re-energizes automatically and the LED R glows. Over- and undervoltage monitoring Applying control supply voltage begins the fixed start-up delay t S. When t S is complete and all phases are present with correcoltage and with correct phase sequence, the output relay energizes and the LED R glows. If the voltage to be monitored exceeds or falls below the fixed threshold value, the output relay de-energizes after the fixed tripping delay t is complete and the LED R turns off. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %, t S starts again. After t S is complete, the output relay re-energizes automatically and the LED R glows. with neutral monitoring L1, L2, L3, N Umax Umax - 5 % Measuring value Umin + 5 % Umin 13- R: yellow LED < < = Start-up delay fixed 500 ms = Tripping delay fixed 500 ms 2CDC 252 047 F0203 without neutral monitoring L1, L2, L3 Umax Umax - 5 % Measuring value Umin + 5 % Umin 2CDC 252 048 F0203 < < 13- R: yellow LED = Start-up delay fixed 500 ms = Tripping delay fixed 500 ms 2 ABB

Connection diagrams L1 L2 L1 L2 L3 N N 13 L3 13 1SC 110 000 F0112 L1, L2, L3, N Control supply voltage = measuring voltage 13- Output contact - closed-circuit principle with neutral monitoring L1 L2 L1 L2 L3 13 L3 13 1SC 110 000 F0113 L1, L2, L3 Control supply voltage = measuring voltage 13- Output contact - closed-circuit principle without neutral monitoring ABB 3

Type 1) Supply circuit = measuring circuit L1-L2-L3-N L1-L2-L3 Rated control supply voltage U S = measuring voltage 3x320-460 AC, 185-265 AC 3x320-460 AC Power consumption Rated control supply voltage U S tolerance -15...+10 % Rated frequency 50/60 Hz (-10...+10 %) Duty time 100 % Measuring circuit L1-L2-L3-N L1-L2-L3 Monitoring functions phase failure over- / undervoltage neutral - Measuring ranges 3x320-460 AC, 185-265 AC 3x320-460 AC Thresholds U min fixed 185 / 320 fixed 320 U max fixed 265 / 460 fixed 460 Hysteresis related to the threshold value fixed 5 % Measuring voltage frequency 50/60 Hz (-10 %...+10 %) Response time 80 ms Measuring error within rated control supply voltage tolerance Measuring error within temperature range m 0.06 % / C Timing circuit Start-up delay t S fixed 500 ms (w20 %) Tripping t at over-/undervoltage fixed 500 ms (w20 %) Indication of operational states Relay status R: yellow LED Output relay energized Output circuits 13- Kind of output 1 n/o contact Operating principle 2) closed-circuit principle Contact material AgCdO Rated voltage (DE 0110, IEC 60947-1) 250 Minimum switching voltage / Minimum switching current - / - Maximum switching voltage 250 AC, 250 DC Rated operational current AC12 (resistive) 230 4 A (IEC 60947-5-1) AC15 (inductive) 230 3 A DC12 (resistive) 24 4 A DC13 (inductive) 24 2 A Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime (AC12, 230, 4 A) 0.1 x 10 6 switching cycles Short-circuit proof, n/c contact 10 A fast-acting max. fuse rating n/o contact 10 A fast-acting AC rating Utilization category (Control Circuit Rating Code) B 300 (UL 508) max. rated operational voltage 300 AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600/360 A General data Dimensions (W x H x D) 22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 inch) Mounting position any Degree of protection enclosure / terminals IP50 / IP20 Mounting DIN rail (EN 50022) Electrical connection Wire size fine-strand with wire end ferrule 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) fine-strand without wire end ferrule 2 x 1-1.5 mm 2 (2 x 18-16 AWG) rigid 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) Stripping length 10 mm (0.39 inch) Tightening torque 0.6-0.8 mm Environmental data Ambient temperature range operation / storage -20..+60 C / -40...+85 C Environmental testing (IEC 68-2-30) 24 h cycle time, 55 C, 93 % rel., 96 h Operational reliability (IEC 68-2-6) 6 g Mechanical resistance (IEC 68-2-6) 10 g 4 ABB

Type 1) Isolation data Rated insulation volt. between supply, measuring and output circuits (DE 0110, IEC 60947-1) 400 Rated impulse withstand voltage U imp between all isolated circuits (DE 0110, IEC 664) 4 k / 1.2-50 µs Tesoltage between all isolated circuits 2.5 k, 50 Hz, 1 min. Pollution category (DE 0110, IEC 664, IEC 255-5) 3 Overvoltage category (DE 0110, IEC 664, IEC 255-5) III Standards Productandard IEC 255-6, EN 60255-6 Low oltage Directive 2006/95/EC EMC Directive 2004/108/EC Electromagnetic compatibility Interference emission EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3-6 k/ 8 k electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 Level 3-10 /m fast transients (Burst) IEC/EN 61000-4-4 Level 3-2 k / 5 khz powerful impulses (Surge) IEC 1000-4-5, EN 61000-4-5 Level 4-2 kl-l HF line emissission IEC 1000-4-6, EN 61000-4-6 Level 3-10 Interference emission EN 61000-6-4 1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured. 2) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold. Technical diagrams Load limit curves AC load (resistive) DC load (resistive) 300 200 100 80 60 50 40 30 20 2CDC 252 194 F0205 300 200 100 80 60 50 40 30 20 2CDC 252 193 F0205 10 0.1 0.2 0.5 1 2 4 6 10 I A 10 0.1 0.2 0.5 1 2 4 6 10 I A Derating factor F Contact lifetime at inductive AC load F 1.0 0.9 0.8 0.7 0.6 0.5 2CDC 252 192 F0205 Switching cycles 250 resistive load 2CDC 252 8 F0206 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Switching current [A] ABB 5

Dimensions in mm 88,5 3.48 81 3.19 22,5.886 78,5 3.09 3.07 78 2CDC 252 189 F0005 Further documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x You can find the documentation online at www.abb.com/lowvoltage R Control Products R... 6 ABB

ABB As part of the on going product improvement, ABB reserves the right to modify the characteristics of the products described in this document. The information given is noncontractual. For further details please contact (www.abb.com/contacts) the ABB company marketing these products in your country. Document number. 2CDC 112 133 D0201 (08/2008) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage R Control Products You can find the address of your local sales organisation on the ABB home http://www.abb.com/contacts R Low oltage products