Keysight Technologies External Source Control X-Series Signal Analyzers Option ESC. Demo Guide

Similar documents
External Source Control

Keysight Technologies N9063A & W9063A Analog Demodulation

Introduction. Part 1. Introduction...2

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies

Keysight Technologies Making Current-Voltage Measurement Using SMU

Introduction. Part 1. Introduction...2

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies Amplifier and CW Swept Intermodulation - Distortion Measurements using the PNA Microwave Network Analyzers.

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies USB Preamplifiers

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies Noise Figure X-Series Measurement Application N9069A & W9069A

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies Secondary Radar Transponder Testing Using the 8990B Peak Power Analyzer. Application Note

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight Technologies N6152A & W6152A Digital Cable TV

Keysight Technologies Compatibility of USB Power Sensors with Keysight Instruments. Application Note

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Keysight Technologies A comparison of Keysight Network Analyzers for Applications < 3 GHz. Selection Guide

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies VOR and ILS Radio Navigation Receiver Test Using Option 302 for Keysight Signal Sources. Application Note

Keysight Technologies mm-wave Source Modules from OML, Inc. for PSG Signal Generators. Technical Overview

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies Accurate Mixer Measurements Using the ENA RF Networks Analyzers Frequency-Offset Mode. Application Note

Keysight 8762F Coaxial Switch 75 ohm

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies N4985A System Amplifiers

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies A Flexible Testbed to Evaluate Potential Co-Existence Issues Between Radar and Wireless

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note

Keysight Technologies Ampliier Linear and Gain Compression Measurements with the PNA Microwave Network Analyzers. Application Note

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies Innovative Passive Intermodulation (PIM) and S-parameter Measurement Solution with the ENA. Application Note

Keysight N9310A RF Signal Generator

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies Triggering on and Decoding the PSI5 Sensor Serial Bus

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies Generating and Applying High-Power Output Signals

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies Compatibility of USB Power Sensors with Keysight Instruments. Application Note

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies Enhancing Measurement Performance for the Testing of Wideband MIMO Signals

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies UXG X-Series Agile Signal Generator, Modified Version N5191A

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Keysight Technologies N6141A & W6141A EMI X-Series Measurement Application. Technical Overview

Keysight Technologies x1149 Boundary Scan Analyzer. Data Sheet

Transcription:

Keysight Technologies External Source Control X-Series Signal Analyzers Option ESC Demo Guide

External source control for X-Series signal analyzers (Option ESC) allows the Keysight PXA, MXA, EXA, and CXA to control the Keysight Technologies, Inc. PSG, MXG, or EXG signal generators for scalar stimulus-response measurements up to 50 GHz. This demonstration guide helps you understand how to: Set up connections between the signal analyzer and the signal source Perform stimulus-response tests to characterize filters, amplifiers, and mixers Apply normalization and open/short calibration to improve measurement accuracy

Demonstration Preparation The demonstrations use an X-Series signal analyzer and Keysight signal generator. Option UNZ is recommended for MXG and EXG X-Series signal generators to obtain the fastest tracking speed. surrounded by [ ] indicate front-panel keys; keystrokes surrounded by { } indicate softkeys located on the display. The sweep modes that Option ESC offers include: Standard sweep Harmonic sweep Power sweep Offset sweep Reverse sweep Table 1. Minimum equipment configuration requirements Product type/ instrument Model number Required configurations PXA, MXA, EXA, and CXA signal analyzer N9030A, N9020A, N9010A, or N9000A Option ESC Firmware Version A.12 or later MXG RF signal generator N5181A or N5182A Firmware Rev. A.01.80 or later MXG MW signal generator N5183A Firmware A.01.80 or later EXG X-Series RF signal generator MXG X-Series RF signal generator PSG signal generator N5171B or N5172B N5181B or N5182B E8257D E8267D Firmware B.01.01 or later Firmware B.01.01 or later Firmware C.06.15 or later Demonstration Setup Connect the X-Series and MXG Figure 1 shows the system set up for this demonstration. The X-Series controls the MXG via the VISA (virtual instrument software architecture) interface which uses a connection of LAN, GPIB, or USB. In this document, we will use a LAN connection. For information about how to set up the GPIB or USB connection, please refer to the instructions displayed on the analyzer screen by pressing [Source], {Select Source...}. Additionally, more detailed information can be found in the X-Series Help files. To access the Help files, press [Help], [Source], {Select Source...}, {Add Source to List}; then press {USB}, {Add Installed USB Sources} for USB connection, or press {GPIB} for GPIB connection. The LAN connection can be made either through a LAN cross-over cable (red) or through the office LAN environment by using two normal LAN cables connected to the X-Series and the MXG, respectively. The frequency reference lock-up between the analyzer and source is not required, but may increase the accuracy. The pair of BNC cables for the triggering are only required for the hardware trigger with which the maximum measurement speed can be achieved. Two pairs of the trigger in/out connectors in the X-Series (Trigger 1 and Trigger 2) can be used interchangeably. Trigger in (or TRIG 1*) Trigger out (or TRIG 2*) Freq. ref. Trigger 1 in Trigger 1 out MXG *For the N5181B/82B MXG or N5171B/72B EXG with default trigger settings Figure 1. Setup of the demonstration system VISA interface DUT 3 X-Series signal analyzer

Configuring the IP addresses The X-Series with Option ESC controls the MXG through a LAN connection based on the TCP/IP protocol. The TCP/IP protocol can only be established with correct IP addressing. The first step is to assign an IP address to the X-Series upon connecting the X-Series and the MXG with a crossover LAN cable. To assign an IP address to the X-Series analyzer, you need to log in to the instrument as the administrator and change the TCP/IP properties. This is done using a USB mouse and a keyboard. To assign the IP address of the X-Series analyzer, log off the defaulted user (Instrument). Log in the administrator. Assign an IP address and a subnet mask to the X-Series through Control Panel ( Category View being the default setting) of the analyzer s Windows operating system. Log off the administrator. Log on the defaulted user (Instrument.) (mouse clicks) Start > Log Off > Log Off At the login prompt enter: User name: administrator Password: keysight4u Start > Control Panel > Network and Internet Connections > Connections; right click Local Area Connection to get a pulldown menu; and select Properties > In the General tab of the Local Area Connection Properties dialog box, select Internet Protocol (TCP/IP), and click Properties. In the General tab of the Internet Protocol (TCP/IP) Properties dialog box, check the Use the following IP address button, and enter: IP address: 192.168.100.1 Subnet mask: 255.255.255.0 Click OK > OK Start > Log Off > Log Off At the login prompt enter: User name: Instrument Password: measure4u Second, assign an IP address to the MXG as follows: Assign an IP address and a subnet mask to the MXG. On MXG: [Utility], {I/O Config}, {LAN Setup}, {Config Type}, {Manual}, {Manual Config Settings}, {IP Address}, {Clear Text}, [192.168.100.3], {Enter}, [Return], {Proceed with Reconfiguration}, {Confirm Change (Network will Restart)} Third, add the MXG to the controlled source list in the X-Series and verify the connection: Enter the external source control mode in X-Series and add the controlled source to the list. Select the source. Verify the source connection. [Source], {Add Source to List}, {LAN}, {Enter LAN Address}, [192.168.100.3], {Enter}, {Add}; the source added to the list will appear [Source], {Select Source }, highlight the source to be controlled by the mouse click or [ ]/[ ], {Select Highlighted Source} {Verify current source connection} 4

Figure 2 shows the source list and results of Verify the current source connection along with the instructions about the USB connection, GPIB connection, and LAN connections. Figure 2. A screen from an X-Series signal analyzer for demonstrating the source list 5

Demonstrations Demonstration 1: MXG MXA/Opt ESC Filter tests with standard sweep RF output Filter (DUT) RF input Filters are one of the most important and most commonly used frequency selective devices. With the external source control capability, you can easily characterize a filter s behavior by using the X-Series coupled with a supported external source. In this section, we use an 880 MHz bandpass filter as a device under test (DUT) to determine its pass-band width, ripple, and shape factor. In the standard sweep mode, the X-Series sweeps synchronically with the MXG at the same start and stop frequencies, and sweep rate. Connect one port of the filter to the MXG RF output, and the other to the X-Series RF input as shown in Figure 3. The standard sweep is the default setting of the source mode. In the standard sweep the start and stop frequencies of the source and analyzer are identical, as is their sweep rate. Figure 3. Setup for filter tests Preset signal analyzer. Set signal analyzer sweep range from 800 to 950 MHz. Enter external source control mode. Start source tracking. Turn on the source RF output. Adjust number of sweep point, if needed. Determine bandwidth at 3 db roll-off. Determine the filter s shape factor ( 60 db vs. 3 db.) Determine the passband ripple. [Mode Preset] [FREQ], {Start Freq} [800] {MHz}, {Stop Freq} [950] {MHz} [Source] {Source mode} {Tracking} Toggle {RF output} to underline On [Sweep/Control], {Points} [601] {Enter} [Marker] {Select Marker 1} {Normal}, rotate the knob to center of the pass band; [Meas Setup], {N db Point}, [-][3]{dB}. Read the bandwidth at -3 db roll off. Refer to Figure 4. [Meas Setup], {N db Point}, [-][60]{dB}. Read the bandwidth at -60 db roll off. Refer to Figure 6. The shape factor (-60 db vs. -3 db) of this filter can be easily calculated from this reading and the one obtained in the preceding step. [Marker] {More} {All Markers Off}, [AMPTD] {Ref Level} [10] {dbm}, {Scale/Div} [1] {db}, [SPAN] [50] {MHz}, [Marker] {Normal}, [Peak Search] {Delta}, rotate the knob to move the delta marker to the trough of passband. Refer to Figure 6. 6

Figure 4. Determine 3 db bandwidth of the filter Figure 5. Determine shape factor by applying the N-dB point markers Figure 6. Measure the passband ripple for the filter 7

Demonstration 2: MXG MXA/Opt ESC Amplifier harmonic tests with harmonic sweep RF output Amp (DUT) RF input Amplifiers are the most common active devices. Harmonic distortion is one of the critical characteristics when evaluating the quality of an amplifier. This demonstration measures harmonic distortion for a Keysight 8447F amplifier (9 khz to 1,300 MHz) with the harmonic sweep setting in the X-Series external source control. In the harmonic sweep mode, the following frequency relationship holds Freq SS = α Freq SA where, α is a multiplier and can further divided into a numerator and denominator (α: multiplier = numerator/denominator). Freq SS is the frequency of the signal source, and Freq SA is the frequency of the signal analyzer. The multiplier α is the ratio of the start and stop frequencies of the source, and sweep rate of the signal source to that of the signal analyzer. The numerator and denominator are both integers and can be set by the user individually. Connect the input port and output port of the amplifier to the MXG RF output and to the X-Series RF input, respectively (Figure 7.) The defaulted standard sweep (multiplier numerator = multiplier denominator = 1) is useful in characterizing the amplifier s frequency responses. Figure 7. Setup for amplifier harmonic tests Preset the signal analyzer. Set the signal analyzer sweep range from 20 MHz to 3 GHz. Enter external source control mode. Adjust the source RF output amplitude to a lower level. This step is of particular importance for the amplifier tests as excessive RF power may damage the amplifier and/ or the analyzer front-end. Return to the menu of source mode. Start source tracking. Turn on the source RF output. Characterize the amplifier s frequency response with standard sweep. Adjust number of sweep points, if needed. Use marker functions to quantify the amplifier s frequency response. [Mode Preset] [FREQ], {Start Freq} [20] {MHz}, {Stop Freq} [3] {GHz} [Source] {Amplitude} [ 40] {dbm} [Return] {Source Mode} {Tracking} Toggle {RF Output} to underline On Both the multiplier numerator and denominator are defaulted to 1. This defaults the standard sweep. Refer to Figure 8 for the result. [Sweep/Control], {Points} [601] { Enter} [Marker] [Peak Search], [Marker] {Delta}, then rotate the knob to move the delta marker to different frequency for the amplitude difference in db. 8

Set harmonic sweep for the higher harmonic measurements. The signal analyzer measures the responses at α times higher start/stop frequencies and sweep rate than that of the stimulus signals from the signal source. Continue from the instrument settings at the end of table shown above. Back to the main menu for external source control mode. Set the multiplier denominator to two for the second harmonic measurement. Adjust number of sweep points, if needed. Use marker functions to quantify the amplifier s frequency response. View source setup. You may set the denominator to 3 for the third harmonic, to 4 for fourth harmonic, and so on. [Source] {Frequency} {Multiplier Denominator} [2] {Enter}. The multiplier numerator is defaulted to 1. [Sweep/Control], {Points} [601] {Enter}. Refer to Figure 9 for the second harmonic measurement result. [Marker] [Peak Search], [Marker] {Delta}, then rotate the knob to move the delta marker to different frequency for the amplitude difference in db. [Source] {More 1 of 2} {Source Setup} {Show Source Capabilities & Settings }. Refer to Figure 10. Set harmonic sweep for the subharmonic measurements. The signal analyzer measures the responses at α times lower start/stop frequencies and sweep rate than that of the stimulus signals from signal source. Continue from the instrument settings at the end of table shown above. Back to the main menu for external source control mode. [Source] Reset the multiplier denominator to 1. {Frequency} {Multiplier Denominator} [1] {Enter} Set the multiplier numerator to 2 for the sub-harmonic (1/2 harmonic). Adjust number of sweep point, if needed. Use marker functions to quantify the amplifier s frequency response. You may set the numerator to 3, 4, for different orders of the sub-harmonic measurements (1/3, ¼, ). {Multiplier Numerator} [2] {Enter} [Sweep/Control], {Points} [601] {Enter}. Refer to Figure 11 for the 1/2 sub-harmonic measurement result [Marker] [Peak Search], [Marker] {Delta}, then rotate the knob to move the delta marker to different frequency for the amplitude difference in db 9

Figure 8. Standard sweep for measure the frequency responses of the amplifier Figure 9. Harmonic sweep (multiplier = 1/2) for the second order harmonic measurement for the amplifier (some abnormality appears for this DUT at 203.5 MHz stimulus for its second harmonic behavior as shown at the marker) 10

Figure 10. Show Source Capabilities & Settings indicates key information of the signal source and signal analyzer settings Figure 11. Harmonic sweep (multiplier = 2/1) for the sub-harmonic measurement for the amplifier 11

Demonstration 3: MXG MXA/Opt ESC Amplifier linearity tests with power sweep RF output Amp (DUT) RF input Another important parameter in characterizing an amplifier is the gain compression or how the amplifier behaves in saturation. Gain compression limits the amplifier s dynamic range. The power sweep mode in Option ESC enables you to easily measure the gain compression. This demonstration will perform the CW gain compression measurement. The external source is controlled so that its power out is swept linearly as the frequency remains constant, such as setting the analyzer for zero sweep span. Connect the input and output ports of an amplifier to the RF output of the MXG and the RF input of the X-Series, respectively (Figure 12.) Figure 12. Setup for amplifier gain compression tests Preset the signal analyzer. Set the signal analyzer center frequency to 870 MHz, and zero span. Set the signal analyzer amplitude reference level to +20 dbm. Enter ESC mode. Set the initial level of the power sweep to 100 dbm. Set the power sweep range to 80 db. Note: It is of paramount importance to carefully set the initial power sweep level and range properly according to the input limits of the amplifier and analyzer, and the amplifier s gain specifications. Excessive RF power may damage the amplifier and/ or analyzer front-end. Return to the menu of source mode. Start source tracking. Turn on the source RF output. Adjust number of sweep point, if needed. Use marker functions to characterize the amplifier s power responses, such as the cut-off level, linear region, and 1-dB compression. [Mode Preset] [FREQ] {Center Freq} [870] {MHz}, [SPAN] {Zero Span} [AMPTD] {Ref Level} [20] {dbm} [Source] {Amplitude} [ 100] {dbm} {Power Sweep} [80] {db} [Return] {Source Mode} {Tracking} Toggle {RF output} to underline On [Sweep/Control], {Points} [601] {Enter} [Marker], then rotate the knob to move the marker to the appropriate input power (X-axis) to characterize the amplifier s power response. Refer to Figure 13 for the result. Figure 13. The power sweep at a fixed frequency tests the amplifier s cut-off level, linear region, and gain compression 12

Demonstration 4: MXG MXA/Opt ESC Mixer tests with offset sweep RF output RF Mixer (DUT) IF RF input Mixers are widely used as frequency translation devices. They provide a signal at the output whose frequency is the sum and difference of the signals on the two inputs. The offset sweep mode available in Option ESC allows you to measure the behavior of a mixer while synchronizing the MXG to sweep with a certain offset frequency, to generate an appropriate intermediate frequency (IF) span. Connect the RF input and IF output of the mixer to the MXG RF output and the X-Series RF input, respectively. For the mixer tests we need an additional signal source to generate a CW signal with a fixed frequency as the LO input. Refer to Figure 14 for the test system setup. Figure 14. Setup for mixer tests LO Second signal source at a fixed frequency Set the second signal source to 700 MHz and 5 dbm RF output as the fixed LO signal. Preset the signal analyzer. Set the signal analyzer start frequency = 800 MHz and stop frequency = 1.3 GHz. Enter external source control mode. Turn the offset sweep mode on and set the offset to 700 MHz (same as the fixed LO frequency). Return to main menu. Set the source RF out level to 0 dbm. Turn on source tracking. Turn on source RF output. Check the source setting. On second MXG signal generator: [FREQ] [700] {MHz}, [AMPLD] [5] {dbm}, toggle [Mod On/Off] to turn off the modulation (LED indicator off); toggle [RF On/Off] to turn on the RF off (the LED indicator is lit) [Mode Preset] [FREQ] {Start Freq} [800] {MHz}, {Stop Freq} [1.3] {GHz} [Source] {Frequency} {Freq Offset} [700] {MHz} [Return] {Amplitude} [0] {dbm} [Source] {Source Mode} {Tracking} [Return], toggle {RF output} to underline On. Refer to Figure 15 for the result of mixer s IF out. [Source] {More 1 of 2} {Source Setup} {Show Source Capabilities & Settings }. Refer to Figure 16. 13

Figure 15. Mixer s IF output when frequency offset is set to 700 MHz Figure 16. Show Source Settings demonstrates that the signal analyzer sweeps from 800 MHz to 1.3 GHz and the signal source from 1.5 to 2.0 GHz 14

In some use cases, particularly for analyzing negative mixing products in a mixer, a reverse sweep becomes desirable. By enabling the reverse source sweep, the signal analyzer controls the source such that it sweeps from a higher frequency to a lower frequency while the signal analyzer itself always sweeps from a lower frequency to a higher frequency. Set the second signal source to 2 GHz and 5 dbm RF output as the fixed LO signal. Preset the signal analyzer. Set the signal analyzer start frequency = 800 MHz and stop frequency = 1.3 GHz. Enter ESC mode. Turn the offset sweep mode on ad set the offset to 2 GHz (same as the fixed LO frequency). Return to main menu. Set the source RF out level to 0 dbm. Turn on reverse sweep. Turn on source tracking. Turn on source RF output. Check the source setting. On second MXG: [FREQ] [2] {GHz}, [AMPLD] [5] {dbm}, toggle [Mod On/Off] to turn off the modulation (LED indicator off); toggle [RF On/Off] to turn on the RF off (the LED indicator is lit) [Mode Preset] [FREQ] {Start Freq} [800] {MHz}, {Stop Freq} [1.3] {GHz} [Source] {Frequency} {Freq Offset} [2] {MHz} [Return] {Amplitude} [0] {dbm} {Frequency}, toggle {Source Sweep} to underline On [Source] {Source Mode} {Tracking} [Return], toggle {RF output} to underline On [Source] {More 1 of 2} {Source Setup} {Show Source Capabilities & Settings }. Refer to Figure 17. Figure 17. Show source settings indicates the source sweeps from a higher frequency to a lower frequency which is opposite to the signal analyzer sweep direction 15

Demonstration 5: MXG RF output RF input MXA/Opt ESC Normalization Normalization is often used in a transmission measurement to correct for systemic errors. The frequency response of the test system must first be measured and then normalization is used to eliminate the frequency response errors caused by the system. V incident (DUT) Thru connection Figure 18. Setup for normalization V transmitted To measure the frequency response of the test system, set up the system as desired for the DUT tests. Then, replace the DUT with a "thru" connection (See Figure 18). Normalization is implemented under the signal analyzer s Trace/Detector menu. A filter used in the standard sweep section is employed here as the DUT. Preset the signal analyzer. Set the signal analyzer sweep range from 800 to 950 MHz. With the thru connection connected, measure the frequency response of the test system. Adjust number of sweep point to 601. Store the frequency response curve of the test system as the reference. Replace the thru with the DUT by removing the thru connection and reconnect the DUT as shown in Figure 18 (with the dashed lines). Activate the normalization, and observe the active trace is now the ratio of the input to the stored reference in db. [Mode Preset] [FREQ], {Center Freq} [870] {MHz}, [SPAN] [150] {MHz} [Source] {Source Mode} {Tracking}, toggle {RF Output} to underline On [Sweep/Control] {Points} [601] {Enter} [Trace/Detector] {More} {More} {Normalize} {Store Ref (1->3)} Toggle {Normalize} to underline On Refer to Figure 19 Figure 19. Results of Normalization with the reference (test system response) displayed in pink and the DUT response displayed in yellow and in db relative to the reference 16

Demonstration 6: Open/short calibration The X-Series with a tracking source and an external directional coupler or directional bridge enables reflection measurements. Performing reflection measurements allows you to determine some critical characteristics for a device, such as reflection coefficient, return loss, and SWR (standing wave ratio). An open/short calibration is used for reflection measurements and corrects for system frequency response errors. Essentially, this type of calibration is a normalized measurement in which a reference trace is stored in memory and will then be subtracted from later measurement data. A calibration created by measuring both an open and a short is more accurate than using only one or the other. Since the open data and short data are 180 degrees out of phase, they tend to average out the calibration errors. Figure 20 is a diagrammatic presentation for reflection measurements and the open/short calibration. The Keysight E4440AU-015 (6 GHz returnloss measurement accessory kit) is recommended in case you need the accessory parts, such as a directional bridge, short, and coaxial cables, required for reflection measurements. MXG V incident MXA/Opt ESC V relected Directional bridge Figure 20. Setup for one-port open/short calibration Preset the signal analyzer. Enter source tracking mode. Start the Open/Short calibration. Follow the graphical instructions given on the X-Series display, Open the bridge output and proceed. Follow the graphical instructions given on the X-Series display, connect a coaxial Short to the output of the directional bridge and proceed. Once done, exit from the Open/Short Cal. Open/Short DUT [Mode Preset] [Source] V transmitted [Trace/Detector] {More} {More} {Normalize} {Open/Short Cal}, Refer to Figure 21 for an example of graphical instructions. {Continue} {Continue} {Done Cal} Figure 21. Graphical instructions displayed on the X-Series lead you through the open/short calibration procedure 17

18 Keysight External Source Control X-Series Signal Analyzers Option ESC Demo Guide mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. Related Literature "Option ESC Technical Overview" 5990-6088EN Web For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-05-19-14) X-Series signal analyzers: www.keysight.com/find/x-series X-Series measurement applications: www.keysight.com/find/x-series_apps X-Series signal generators: www.keysight.com/find/x-series_sg PSG signal generator: www.keysight.com/find/ps This information is subject to change without notice. Keysight Technologies, 2013-2014 Published in USA, August 3, 2014 5990-5922EN www.keysight.com