OFFICE CHANNEL UNIT AND AUXILIARY DIGITAL DATA SYSTEM

Similar documents
DATA SET 109B TYPE DESCRIPTION

DATA SETS 1 08D- AND 1 08E-TYPES SINGLE PRIVATE LINE STATION ARRANGEMENT USING DATA AUXILIARY SET 820D TEST PROCEDURES

E2 STATUS REPORTING AND CONTROL SYSTEM STATUS DESCRIPTION

INPUT AND OUTPUT POWER ADJUSTMENTS PRIMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRIER ANALOG MULTIPLEX TERMINAL EQUIPMENT

INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES OR ES

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

AUXILIARY KHZ PILOT SUPPLY TESTS

DMS-1 * DIGITAL MULTIPLEX SYSTEMS

SERIES 5-COMPATIBLE INTELLIGENT 4W ETO CHANNEL UNIT MODEL AUA441C (ISSUE 2) (*CLEI Code: 5SC2XM02AA)

1995 Metric CSJ , etc. SPECIAL SPECIFICATION ITEM D-I Muldem (Drop/Insert Multiplexor/Demultiplexor)

Advanced Test Equipment Rentals ATEC (2832)

) #(2/./53 $!4! 42!.3-)33)/.!4! $!4! 3)'.!,,).' 2!4% ()'(%2 4(!. KBITS 53).' K(Z '2/50 "!.$ #)2#5)43

Complete Self-Test. Plug-in Module Self-Test

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

4-WIRE ORDER CIRCUIT TESTS

MAINTENANCE MANUAL FOR CONVENTIONAL NETWORK INTERFACE

MULTI-TONE GENERATOR V

QWEST Communications International Inc. Technical Publication

DIGITAL LINK MEASURING INSTRUMENTS MS371A/A1 GPIB PCM CHANNEL ANALYZER. For Simultaneous Measurement of 30 Channels with MS120A

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Chapter 5 Diagnostics

KiloStream Data Sheet

R PROFLAME Instruction Book Collection

Figure FXS Front Panel. Figure FXS Front Panel

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide

Part IV: Glossary of Terms

ZT-30 ZeroTEM TRANSMITTER MANUAL

SMS control unit for SRK transmitters

Electronics II Physics 3620 / 6620

SPECIFICATION EP 1000/1500/2000 Series

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

BCV-1203 Barcode Verification System Users Guide Version 1.2

Appendix C T1 Overview

Sage Instruments 935AT. Test Options Guide

Remote Switching. Remote Gates. Paging.

Remote Switching. Remote Gates. Paging.

MAINTENANCE MANUAL DIGITAL SELECTOR MODULE 19D902519G1 TABLE OF CONTENTS

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

Inductive Loop Detector

SmartRadio Transmitter / Receiver

XR-T6165 Codirectional Digital Data Processor

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

XR-T6164/T6165/T6166. Evaluation System User Manual

8-Bit A/D Converter AD673 REV. A FUNCTIONAL BLOCK DIAGRAM

Technical Application Note #3

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

PRIVATE LINE LOCAL CHANNEL SERVICES TARIFF

HC900 Hybrid Controller

Product Guide Verizon Delaware LLC. Section 31 Delaware LLC Original Sheet 1. Connection With Certain Facilities of Others

INTERCONNECTING DEVICES COMMON EQUIPMENT 75A CONTROL UNIT

Complimentary Reference Material

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

The HC-5560 Digital Line Transcoder

Announcements. Advanced Digital Integrated Circuits. Midterm feedback mailed back Homework #3 posted over the break due April 8

PA FAN PLATE ASSEMBLY 188D6127G1 SYMBOL PART NO. DESCRIPTION. 4 SBS /10 Spring nut. 5 19A702339P510 Screw, thread forming, flat head.

Operator Manual 1.4 FRACSIM MINI

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

Introduction Identification Implementation identification Protocol summary. Supplier 1

TCI Library-

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

Exercise 1-4. Pulse Dialing

GDC 086R Issue 4, 10/17/97. Installation and Operation. Metroplex Flexi-Voice Plus Model MP General DataComm

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

MAINTENANCE MANUAL DIGITAL SELECTOR MODULE 19D902519G1 INCLUDING DIGITAL SELECTOR 1 (150 BAUD DATA) AND DIGITAL SELECTOR 2 (9600 Hz CLOCK)

MULTIMETER TRAINING UNIT QUICKSTART GUIDE

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

Department of Electronics & Telecommunication Engg. LAB MANUAL. B.Tech V Semester [ ] (Branch: ETE)

GCSE Electronics 44301

ACCESS SERVICE TARIFF S.C.C.-Va.-No Verizon Virginia LLC Section 7 1st Revised Page 1 Cancels Original Page 1 SPECIAL ACCESS SERVICE

HT101V Reference Manual

1.1 End-to-End Testing Conditions End2End Step-by-Step Local ATV-25 Remote ATV-25

HEATHKIT HD-1410 ELECTRONICKEYER

Westell DS1 Network Interface Unit

The Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis

Application Note 5044

SIN 57 Issue 2.4 May 2018

DS2186. Transmit Line Interface FEATURES PIN ASSIGNMENT

Somfy RTS Motor Programming Instructions Motor Programming Instructions have been rewritten by

MFJ ENTERPRISES 300 INDUSTRIAL PARK STARKVILLE, MS USA

USB 3.1 ENGINEERING CHANGE NOTICE

B & D Enterprises 1P repeater controller pg 1 INTRODUCTION:

Part VI: Requirements for ISDN Terminal Equipment

ericssonz MAINTENANCE MANUAL ORION BUFFER BOARD ROA SPECIFICATIONS TABLE OF CONTENTS

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Product type designation. General information. Supply voltage

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES

DS V Bit Error Rate Tester (BERT)

DSTS-3B DEPTHSOUNDER TEST SET OPERATOR S MANUAL

4. Digital Measurement of Electrical Quantities

Product Guide Verizon Delaware LLC. Section 11 Delaware LLC Original Sheet 1. Channels

PAiA 4780 Twelve Stage Analog Sequencer Design Analysis Originally published 1974

mat-30 HF-SSB Automatic Antenna Tuner Instruction Manual Version V1.0

Analog Inputs and Outputs

OEM WIRELESS DIALLER INSTALLATION & USER MANUAL. (Product No )

Motorola APX. G1 SCBA Radio Pairing Guide Motorola APX. G1 SCBA Radio Pairing Guide for

SERVICE 2565HK AND 2565HKM TELEPHONE SETS

Blue Point Engineering Inc.

MultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

METALLIC FACILITY TERMINAL LOOP-START AND GROUND-START TO DX OR E&M SIGNALING CONVERTERS (J99343FA, FB, FC, AND FD)

Transcription:

AT& T PRACTCE!krnclarct AT&T 314-910-500 ssue 6, December 1986 OFFCE CHANNEL UNT AND AUXLARY CRCUTS TEST S DGTAL DATA SYSTEM CONTENTS PAGE nstallation Testing 1. GENERAL...........1 2. LATCHNG LOOPBACK CONTROL ON HL220 AND HL222...........1 3. CHARTS............3 Figures 1. DDS Network Loopback Applications.. 15 1.03 f at some time after initial installation, a new customer is to be added to the DDS, perform the following tests in the sequence given: Chart 1 on any added power units Chart 2 on all added OCUS $Chart 3 on all added OCU units with latching loopback.4 Tables Maintenance Testing A. KS-20909/20908 DTS Connections on D-T HL7and HL89......... 11 1.04 Any or all of the tests provided herein may be used in troubleshooting an OCU. B. c. 1. GENERAL SMX (HL8/HL8B) Test Point and Jack Use.............. 12 SMX (HL88/HL88B) Test Point and Jack Use.............13 CAUTON: Performance of the OCU loopback test, chart 2, will interrupt customer service. Therefore, chart 2 must not be performed except after prior notice has. been given to the customer or when the channel is known to be idle or out of service. 1.01 This practice describes the test procedures to be used when troubleshooting an OCU (office channel unit) or as installation tests of the OCU when a customer is added to the DDS (Digital Data System) at some time after the initial installation. The following text has been written with the assumption that the reader has a general knowledge of the operation, terminology, and physical appearance of the OCU assemblies. This information is provided in the practice entitled Digital Data System Office Channel Unit and Auxiliary Circuits Description (314-910-100). 1.02 This practice is reissued to add the OCU latching loopback test. Revision arrows are used to emphasize the more significant changes. RECEVED Copyright 1986 AT&T ~F~ 27 ~y~7 All Rights Reserved 1.05 Chart 2 requires the use of the practices entitled Digital Data System KS-20909 Data Test Set (Transmitter) Description and Operation (107-600-100) and Digital Data System KS-20908 Data Test Set (Receiver) Description and Operation (107-601-100). 2. *latc+ng LOOPBACK CONTROL ON HL220 AND HL222 2.o1 To detect the presence of an OCU with latching loopback, a latching loopback must be executed. Some OCUS respond only to the non-latching loopback sequence used in the DDS network. The HL220 OCU will respond to both latching and nonlatching loopback control sequences. Therefore, if the OCU fails to respond to a latching loopback control Printed in U.S.A. Page 1 NETWORK lnformatcli cfnter

AT&T 314-910-500 sequence and successfully responds to the nonlatching ioopbaek, it is not an HL220 OCU. 2.o2 The latching loopback sequence uses three control codes and one equipment-specific data code. The control codes are: TP (transition in progress) LBE (oopback enable) FF.V (far-end voice). The LBE code is mapped in the forward direction to allow the loopback of one of several identical plug-ins in tandem. MAP O or MAP 1 is also returned in the reverse direction in response to LBE codes sent during the looped state and may be used to differentiate between loopback locations. 2.03 The latching loopback bit patterns are: MAP Oor MAP 1 is also returned in the reverse direction in response to LBE codes sent during the looped state and may be used to differentiate between loopback locations. 2.05 Loopback processors on each type of equipment are programmed (during manufacture) to respond to these unique data codes which must be received in the data stream before the loopback can be enabled. 2.06 There are two latching loopback procedures that may be used to establish a loopback in the network. The two procedures are: (a) Only one specific unit of equipment is on the circuit or the first of several identical units in tandem is to be looped back. (b) The second of two identical units in tandem is to be looped back. TP = 00111010 L13E = 01010110 FEV = 01011010 2.07 used. (1) To establish a loopback as described in paragraph 2.06 (a), the following procedure may be TP - is sent to clear the channel. Note: 0 = Don t care symbol. 2.04 The latching loopback data codes are referred to as LSCS (loopback select codes). One of the following LSC bit patterns must be transmitted as part of the latching loopback sequence to select the loopback location: (2) LSC - is sent to identify a particular unit of equipment, enables the equipment to recognize and respond to subsequent data bursts. (3) LBE - is sent to enable the equipment to be looped back. The first unit to receive this code maps it into MAP O or MAP 1 and sends these MAP data codes downstream. LSC BT MAP CODE Ocu 01010101 MAP 1 CSU (channel)?o110001 MAP O LS HL222 01000111 MAP 1 (4) FEV - is then sent to actually cause the loopback. The equipment returns FEV in the SC mode or 01111010 in the nonsecondary channel mode to the tester when the loopback is successfully latched. 2.08 f the loopback is as described in paragraph 2.06 (b), the following procedure applies. Note: No LSC can equal 11111111. MAP O = 10010011 MAP 1 = 01101101 (1) TP - is sent to clear the channel (2) LSC - is sent to identify a particular unit of equipment, enables the equipment to recognize and respond to subsequent data bursts. Page 2

1 1SS6, AT&T 314-910-500 (3) LBE - is sent to enable the equipment to be looped back. The first unit to receive this code maps it into MAP O or MAP 1 and sends these MAP data codes downstream. (4) ALL ONES - burst is sent and the equipment will cease to send mapped code downstream. nstead, it will send through whatever is received. Thus, the sequence shown addresses the second of two identical units in tandem. 71C1 (or 76C1) power units and the central office battery supply ( 24 V or 48 V) to the power units. Chart 2. OCU Loopback Test: This test checks the loopback feature of the OCU from the following DDS Hub Office Test points on the faceplate of the D-T (digital-terminal) CP (HL7) (5) LBE - is sent to enable the equipment to be looped back. (6) FEV - is sent for the second unit to loop back and return FEV in the SC mode or 01111010 in the non-sc mode to the tester. This procedure (i.e., repetitions of LBE and ALL ONES) can be repeated as often as necessary to loop back any one of an unlimited number of identical tandem units. 2.09 Termination of the loopback is accomplished by sending a TP code. DDS Local Office OCU used with D-T CP HL7 M-JCP (multiplexer jack and connector panel) or SM-JCP (submultiplexer jack and connector panel) OCU used with D-T CP HL89 test jacks on the faceplate of the D-T CP OCU used with SMX (integral subrate multiplexer) CP HL8/HL8B or HL88/HL88B test points on the faceplate of the SMX CP. 2.10 The OCU latching loopback tests are covered in Chart 3.4 n addition, an error run is made on the data being looped back by the OCU. 3. CHARTS 3.01 The tests covered are as follows: Chart 1. Power Unit Test: This test checks the +12, 12, and +15 volt outputs of the 71C (or 76C) and $Chart 3. Latching Loopback Test: This test checks the latching loopback feature of the HE220 OCU and the HL222 LS (loop side interface). Also, this test detects the presence of an OCU or LS without latching loopback.t Page 3

AT&T 314-910-500 CHART 1 POWER UNT TEST APPARATUS: 1 KS-16979-L1 VOM (volt-ohm-milliammeter) or equivalent 1 2 3 Condition the VOM to measure 48 V de (71C or 71C1 power unit) or 24 V dc (76C or 76C1 power unit). Connect the positit e (+) meter lead to the BAT RTN test point of the power unit. Connect the negative ( ) meter lead to the 48 V (or 24 V) test point of the power unit. Requirement: Meter indicates between 42 and 52 volts (71C or 71C1) or between 20 and 27 volts (76C or 76C1). 4 5 6 Disconnect both meter leads. Connect the negative ( ) meter lead to the SG test point of the power unit. Connect the positive (+) meter lead to the +12 V test point of the power unit. Requirement: Meter indicates between 11 and 13 volts. 7 Disconnect the positive (+) meter lead and connect it to the +5 V test point of the power unit. Requirement: Meter indicates between 4.5 and 5.5 volts. 8 9 10 Disconnect both meter leads. Connect the positive (+) meter lead to the SG test point of the power unit. Connect the negative ( ) meter lead to the 12 V test point of the power unit. Requirement: Meter indicates between 11 and 13 volts. 11 Disconnect both meter leads. Page 4

1SS6, AT&T 314-910-500 CHART 2 OCU LOOPBACK TEST APPARATUS: 1 KS-20909 DTS (data test set) transmitter 1 KS-20908 DTS receiver 1 Plug the clock input cords of both DTSS into TST1 and TST2 of the BCPA (bay clock, power, and alarms) or LTS (local timing supply) assembly. 2 Plug the power cords of both DTSS into 117-volt, 60-Hz outlets and operate both POWER ON switches. Requirement: POWER ON switches and CLOCK LED (light-emitting diode) indicators on both DTSS lighted. 3 Set switches on KS-20908 DTS receiver as follows: NPUT to BPOLAR for OCU or LS (loop side interface [HL222] ) with HL7 D-T CP or NEAR LOGC for OCU or LS HL222 with SMX or HL89 D-T CP DATA RATE to speed of OCU or LS (HL222) under test COUNTER to BLOCK ERRORS TESTWORD to LOOPED SUBRATE CHANNEL to SNGLE COUNTER MODE to HOLD. 4 Set switches on KS-20909 DTS transmitter as follows: OUTPUT to BPOLAR for use with HL7 D-T CP or NEAR LOGC for use with SMX or HL89 D-T CP DATA RATE to speed of OCU or LS (HL222) under test FUNCTON to LOOPBACK TEST. 5 Connect the data input cord of the KS-20908 DTS receiver as follows: DDS hub offices Connect to appropriate transmit (OUT) test points on HL7 D-T CP in accordance with Table A. Page 5

AT&T 314-910-500 CHART 2 (Contd) DDS local office OCU or LS (HL222) with HL7 D-T CP Connect to appropriate FROM (NEAR) jack on SM-JCP or M-JCP. f the KS-20908 DTS is equipped with a TERMNATE key, depress the key and/or observe that the TERMNATE LED is lighted. DDS local office OCU or LS (HL222) with SMX (HL8/HL8B or HL88/HL88B) CP Connect to appropriate test points (test points 7 through 20 only) on SMX (HL8/HL8B) CP in accordance with Table B, or appropriate test points (test points 3 through 12 and 17 through 26) on SMX (HL88/HL88B) CP in accordance with Table C. DDS local office OCU or LS (HL222) with HL89 D-T CP Connect to TEST jack on HL89 D-T CP. 6 Connect data output cord of KS-20909 DTS as follows: DDS hub office Connect to appropriate receive (N) test points on HL7 D-T CP in accordance with Table A. DDS local office OCU or LS (HL222) with HL7 D-T CP Connect to appropriate TO (NEAR) jack on SM-JCP or M-JCP. DDS local office OCU or LS (HL222) with SMX (HL8/HL8B or HL88/HL88B) CP Connect to appropriate test jack on SMX CP in accordance with Table B or C. DDS local office OCU or LS (HL222) with HL89 D-T CP Connect to appropriate jack (J1-J5) on HL89 D-T CP in accordance with Table A. 7 8 f testing an OCU in a DDS hub office Request the testing technician to insert a dummy plug into the TO (NEAR) jack of the $associated JCP4 under test. Momentarily operate the KS-20909 DTS RESET key. Requirement: All CONTROL CODES and LOOPBACK TEST indicators extinguished. 9 Depress and hold the KS-20909 DTS OCU LOOPBACK TEST key. Requirement: On KS-20908 DTS, BYTE PATTERN LED 8 and one other lighted. All others extinguished, Note: f the requirement for Step 9 is not met, troubleshoot the OCU as directed in Practice 314-910-300. 10 11 Release the OCU LOOPBACK TEST key. Momentarily operate the COUNTER MODE switch on the KS-20908 DTS to RESET and start timing a 15-second interval. Requirement: OVERFLOW indicator extinguished and COUNTER resets to all zeros. Page 6

1SS6, AT&T 314-910-500 CHART 2 (Contd) 12 At the end of the 15-second interval Operate COUNTER MODE switch to HOLD. Requirement: KS-20908 DTS counter indicates zero errors. Note: f errors are recorded, troubleshoot the OCU as directed in Practice 314-910-300. 13 Disconnect both DTSS. 14 f testing an OCU in a DDS hub office Request the testing technician to remove the dummy plug inserted in Step 7. OCHART 3 HL220 or HL222 LATCHNG LOOPBACK TEST The DDS network latching loopback sequence can be generated with the existing DDS KS-20909 DTS transmitter or the BATS (Bit Access Test System) panel through the use of the byte encoder and all ones in the switches. The procedure requires the circuit to be accessed at DS-OA level. This test can be used to indicate compatibility of the OCU. The DDS network loopback application is shown in Fig. 1. APPARATUS: 1 KS-20909 DTS transmitter 1 KS-20908 DTS receiver 1 Plug the clock input cords of both DTSS into TST1 and TST2 of the BCPA (bay clock, power, and alarms) or LTS (local timing supply) assembly. 2 Plug the power cords of both DTSS into 117-volt, 60-Hz outlets and operate both POWER ON switches. Requirement: POWER ON switches and CLOCK LED (light-emitting diode) indicators on both DTSS lighted. 3 Set switches on KS-20908 DTS receiver as follows: NPUT to BPOLAR for use with HL7 D-T or NEAR LOGC for use with SMX or HL89 D-T CP DATA RATE to speed of OCU or LS under test Page 7

AT&T 314-910-500 *CHART 3 (Contd) COUNTER to BLOCK ERRORS TESTWORD to LOOPED SUBRATE CHANNEL to SNGLE COUNTER MODE to HOLD. 4 Set switches on KS-20909 DTS transmitter as follows: OUTPUT to BPOLAR for use with HL7 D-T CP or NEAR LOGC for use with SMX or HL89 D-T CP DATA RATE to speed of OCU or LS under test FLTNCTONT to BYTE ENCODER,5 Connect the data input cord of the KS-20908 DTS receiver as follows: DDS hub offices Connect to appropriate transmit (OUT) test points on HL7 D-T CP in accordance with Table A. DDS local office OCU or LS with HL7 D-T CP Connect to appropriate FROM (NEAR) jack on SM-JCP or M-JCP. f the KS-20908 DTS is equipped with a TERMNATE key, depress the key and/or observe that the TERMNATE LED is lighted. DDS local office OCL or LS with SMX (H.8/HL8B or HL88/HL88B) CP Connect to appropriate test points (test points 7 through 20 only) on SMX (HL8/HL8B) CP in accordance with Table B, or appropriate test points (test points 3 through 12 and 17 through 26) on SMX (HL88/HL88B) CP in accordance with Table C. DDS local office OCU or LS with HL89 D-T CP Connect to TEST jack on HL89 D-T CP. Caution: f receiver B YTE PATTERN indicator lamp number 8 is lighted, and indicators 2 through 7 are dimly lighted, customer data is being sent over that channel. Obtain customer permission to test before disturbing the circuit. 6 Connect data output cord of KS-20909 DTS as follows: DDS hub office Connect to appropriate receive ( NT)test points on HL7 D-T CP in accordance with Table A. DDS local office OCLT or LS with HL7 D-T CP Connect to appropriate TO (NEAR) jack on SM-JCP or M-JCP. DDS local office OCU or LS with SMX (HL8/HL8B or HL88/HL88B) CP Connect to appropriate test jack on SMX CP in accordance with Table B or C. Page 8

1SS6, AT&T 314-910-500 $CHART 3 (Contd) DDS local office OCU or LS with HL89 D-T CP Connect to appropriate jack (J1-J5) on HL89 D-T CP in accordance with Table A. 7 8 f testing an OCU in a DDS hub office Request the testing technician to insert a dummy plug into the TO (NEAR) jack of the associated JCP under test. Momentarily operate the KS-20909 DTS RESET key. Requirement: All CONTROL CODES and LOOPBACK TEST indicators extinguished. Setting of Switches on KS-20909 DTS 9 Set BYTE ENCODER to TP (00111010) code. 10 Depress and hold ALL-ONES button. This transmits an all 1s data pattern while the BYTE ENCODER switches are changed. 11 Set BYTE ENCODER switch to 01010101 (OCU LSC) or 01000111 (LS LSC). 12 Release ALL-ONES button to transmit LSC. Transmit the LSC for at least one second. 13 Depress ALL-ONES button and set BYTE ENCODER to LBE (01010110) code. 14 Release ALL-ONES button to transmit LBE code. 15 Depress ALL-ONES button. 16 Set BYTE ENCODER to FEV (01011010) code. 17 Release ALL-ONES button and observe code display on receiver to confirm a successful loopback. HL222 =EE * NSC = non-secondary channel 18 Perform error rate tests using any using applicable AT&T practices. pattern of data except TP (00111010) or LBE (01010110) codes Page 9

AT&T 314-910-500 $CHART 3 (Contd) 19 When testing is completed, ensure that the KS-20909 DTS FUNCTON switch is set to BYTE ENCODER. Set BYTE ENCODER to TP (00111010) code and transmit to release loopback. 20 Disconnect both DTSS. 21 f testing an OCU in a DDS hub office Request the testing technician to remove the dummy plug inserted in Step 7.4 4. SSUNG ORGANZATON Published by the AT&T Documentation Management Organization. Page 10

1SS6, AT&T 314-910-500 TABLE A KS-20909/20908 DTS CONNECTONS ON D-T HL7 AND HL89 CHANNEL OF OCU D-T CP D-T CP SHELF UNDER D-T RECEVE TRANSMT HL89 D-T TEST POSTON TEST PONTS* TEST PONTS CP JACKSt 1 33 N 1 OUT 1 J1 2 33 N 2 OUT 2 J2 3 33 N 3 OUT 3 J3 4 33 N 4 OUT 4 J4 5 33 N 5 OUT 5 J5 6 35 N 1 OUT 1 J1 7 35 N 2 OUT 2 J2 8 35 N 3 OUT 3 J3 9 35 N 4 OUT 4 J4 10 35 N 5 OUT 5 J5 * The signal at these test points is at the bipolar level. ~ The signal present at these jacks is at the logic level, and can be checked by inserting the KS-20909 DTS plug into the appropriate jack (J1-J5) and inserting the KS-20908 DTS plug into the TEST jack. Page 11

AT&T 314-910-500 TABLE B SMX (HL8/8B) TEST PONT AND JACK USE TEST PONT(S) OCU OR 1S1 OR CHANNEL(S) TEST JACKt ACCESSED TYPE SGNAL FROM TO USE TP1 and TP2 1 through 5 64-kb/s composite M-JCP HL8/8B Monitor composite 5-channel 5-channel bipolar data signal. TP3 and TP4 HL8/8B M-JCP TP7 1 64-kb/s Ocu HL8/8B Monitor individual channel single data. TP8 channel HL8/8B Ocu logic TP9 2 level Ocu HL8/8B TP1O HL8/8B Ocu TP13 3 Ocu HL8/8B TP14 HL8/8B Ocu TP17 4 Ocu HL8/8B TP18 HL8/8B Ocu TP19 5 Ocu HL8/8B TP20 HL8/8B Ocu J1 1 Signal flow direction Transmit individual channel depends on portable data with portable DTS. J2 2 DTS OUTPUT LQGC NEAR/FAR switch J3 3 setting. J4 4 J5 5 TP12 Signal ground point * The use of the test points alone does not interrupt the OCU or LS channel. t The use of test jack interrupts the OCU or LS channel.

1SS6, AT&T 314-910-500 TABLE C nitialize CP during nstallation. SMX (HL88/88B) TEST PONT AND JACK USE El== TYPE SGNAL FROM TO USE 1=-1-=- 64-kb/s single channel logic Ocu HL88/88B level HL88/88B * Ocu TP7 Ocu HL88/88B HL88/88B Ocu Monitor individual channel data Ocu HL88/88B HL88/88B Ocu Ocu HL88/88B TP12 HL88/88B Ocu 1 64-kb/s composite 10- channel binolar M-JCP HL88/88B HL88/88B M-JCP TP17 1 64-kb/s single Ocu HL88/88B TP18 channel logic HL88/88B Ocu 1 ----- PVP, 4 TP19 2 TP21 3 TP22 TP23 4 TP24 Ocu HL88/88B ] HL88/88B Ocu Ocu HL88/88B Monitor composite 10- channel data signal Monitor individual channel data TP25 5 TP26 Ocu HL88/88B HL88/88B Ocu Page 13.

AT&T 314-910-500 [ TABLE C (Contd) SMX (HL88/88B) TEST PONT AND JACK USE TEST PONT(S) OR TEST JACKt OCU OR 1S1 CHANNEL(S) ACCESSED TYPE SGNAL FROM TO USE J] J2 J3 J4 1 2 3 4 64-kb/s single channel logic level Signal flow direction depends on portable DTS OUTPUT LOGC NEAR/FAR switch setting. Transmit individual channel data with portable DTS. J5 5 J6 6 J7 7 J8 8 J9 9 J1O 10 TP27 Signal ground point * The use of the test points alone does not interrupt the OCU or LS channel. * The use of a test jack interrupts the OCU or LS channel. Page 14

.- - _ - - - DOSHUB OFFCE 100S ENOOFFCE DATAPORT TANOEM CLSTOMERPREFSES 1 $ OFFCE $ 1 LSC LSC2 i i$lsc2 LSC2 A B 11 HL 0s0 0s0 0s0 Ocu OS-OA L36 1HL18 HLB 222 OP OP OP * OP T-1 1 T-1-1 TEST [ ~~ Osu Osu CENTER w 11 SLC@ SLC@ D-BAN O-BAN COT RT SROM TOM TDH SMX J L +.- 1 L -. -J 1-, _J L-.. _. LEGENO: CSU = CHANNEL SERVCE UNT SLC@ COT = OSU = OATA SERVCE UNT SLC@RT = DP = DATAPORT SROM = SPX = NTEGRATE SUB-RATE TOM = OATA ULTPLEXER OCU = OFFCE CHANNEL UNT CENTRAL OFFCE TERMNAL REMOTE TERMNAL SUB-RATE OATA MULTPLEXER T1 OATA MULTPLEXER NOTE : 1. SEQUENCES SENT FROM HUB TO LOOPBACK CONTROL OF NOCATEO PLUG-NS HL222 OSO-OP OSO-OP OSO-DP TP TP TP TP TP = TRANSTON N PROGRESS----(OO1O1O) LSC1 LSC2 LSC2 LSC2 LSC = LOOPBACK SELECT COOE -----(SEE PAR. 2.04) LEE LEE LEE LEE LEE = LOOPBACK ENABLE ----------(O1O1O11O) FEV FEV ALL-ONES ALL-ONES FEV = FAR-ENO VOCE ------------- (01011010) LEE LEE FEV ALL-ONES LEE FEV Fig. l DDSNetwork Loopback Applications (Note 1)