Tutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes

Similar documents
Accredited Standards Committee C63 - EMC

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

Test specification: Section (e)(1), Radiated emissions below 40 GHz Test procedure: ANSI C63.4, Sections 8.3.2, 13.2, 13.4 Test mode: Compliance

FCC ID: A3LSLS-BD106Q. Report No.: HCT-RF-1801-FC003. Plot Data for Output Port 2_QPSK 9 khz ~ 150 khz Middle channel 150 khz ~ 30 MHz Low channel

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd.

STC Test Report. Date : Page 1 of 13 No. : HM161169

FCC Verification TEST REPORT

To «Test_Standards» Test of: Radwin Ltd. Outdoor Subscriber Radio Unit. To: FCC CFR 47 Part 15B; ICES-003 Issue 6: 2016

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

FCC PART 15 B CLASS B TEST REPORT

Fully Anechoic Room Validation Measurements to CENELEC pren

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCE EMITTED FROM TELECOMMUNICATIONS EQUIPMENT

Verification Test Report

King Pigeon Communication Co., Limited

Test sites for EMC measurements

Radiated emission is one of the most important part of. Research on the Effectiveness of Absorbing Clamp Measurement Method.

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

FCC PART TEST REPORT. Weccan Industrial Limited

US Council of EMC Laboratories [USCEL] Technical Issues having Significant Cost Implications for EMC Laboratory Owners/Operators

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

TEST REPORT. Issued for:

Large E Field Generators in Semi-anechoic Chambers for Full Vehicle Immunity Testing

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

REPORT REVISION HISTORY...

FCC PART 15B TEST REPORT SZ DJI TECHNOLOGY CO., LTD

RADIO TEST REPORT SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD. Prepared By : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD

D. Guarnone (verifier)

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

EMC TEST REPORT - Addendum

FCC & IC Certification. Test Report. FCC & Industry Canada Certification. Test Report. for Hetronic USA FCC ID: LW9-CS434TXN IC ID: 2219A-CS434TXN

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

SIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION

CENTRE OF TESTING SERVICE INTERNATIONAL

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

EMI T E S T R E P O R T

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

STC Test Report. The Hong Kong Standards and Testing Centre Ltd.

EMC Test Report. Report Number: M030826

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

2310 to 2390 MHz, 3m distance MCS8 (MIMO) to 2500 MHz Restricted band MCS8 (MIMO)

TEST REPORT... 1 CONTENT...

Pico 900MHz 1W FHSS Module Model: p900 FCC ID: NS913P900. Applicant:

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

TEST REPORT. Table of Contents

CHARACTERISATION OF IN -HOUSE EMC TESTING FACILITIES FOR PRODUCT DESIGNERS. Paul Kay* and Andrew Nafalski**

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

RADIO TEST REPORT. For MODEL NO FCC ID: C3K1703 IC ID: 3048A Test Report No. R-TR190-FCCIC-UNII-1 Issue Date: 14 September 2015

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

Compliance Engineering Ireland Ltd

ACCORDING TO: FCC part 15 subpart C, and subpart B FOR:

VSWR AND ANTENNA SYSTEMS Copyright by Wayne Miller 2018 Revision 4 page 1 of 6

9. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY

Normalized Site Attenuation Test Report

TEST REPORT Title 47-Telecommunication

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

PMM 7010 EMI RECEIVERS. The EMI Receiver with built-in LISN

TEST REPORT. Table of Contents

FCC PART TEST REPORT. POSH Mobile Limited

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

15.247(d) RF Conducted Emissions & Band Edge

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCE EMITTED FROM TELECOMMUNICATIONS EQUIPMENT

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

FCC CERTIFICATION TEST REPORT

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

This is a preview - click here to buy the full publication

TEST REPORT. Table of Contents

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4

SERIES K: PROTECTION AGAINST INTERFERENCE

A Complete Simulation of a Radiated Emission Test according to IEC

ENGINEERING TEST REPORT

STC Test Report. Date: Page 2 of 25 No.: MH The Hong Kong Standards and Testing Centre Ltd.

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

TEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

SILENT PARTNER Model No.: SCOOP FCC ID: WXMSCOOP. In Accordance With

COMMUNICATION CERTIFICATION LABORATORY 1940 West Alexander Street Salt Lake City, UT

SHURE ELECTROMAGNETIC COMPATIBILITY LABORATORY TEST REPORT

UL Japan, Inc. Head Office EMC Lab Asama-cho, Ise-shi, Mie-ken JAPAN Telephone : Facsimile :

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

TEST REPORT CONCERNING THE COMPLIANCE OF AN INDUCTIVE LOOP VEHICLE DETECTOR, BRAND NORTECH, MODEL PD231 AND PD234 WITH 47 CFR PART

ANALYSIS AND EVALUATION OF UNCERTAINTY FOR CONDUCTED AND RADIATED EMISSIONS TESTS MOHAMED EMHEMED ABDURRAHIM

Model: M /800 MHz Mobile Radio

LTE Band 7. Channel

FCC Test Report. Report No.: PTCDQ FC01

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Transcription:

Tutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes Note: For the benefit of those who are not familiar with details of ISO 13528:2015 and with the underlying statistical principles upon which it relies, the following very brief and highly simplified tutorial has been prepared as an aid to understanding the process involved. Part 1: Determining the Assigned Values Suppose we assign an PT Test Artifact to be measured by a "Perfect Test Operator" who works in a "Perfect Test Lab". This "Perfect Test Operator" then makes emissions measurements (i.e., collects measured data) that are error free, and those "error free" measurements are made using an instrumentation chain (that includes a non-weatherprotected OATS equipped with an infinite, perfectly conducted Ground Plane and located in a completely ambientfree environment) that is "error free" as well. After reducing the measured data, the resulting final measurements will be "perfectly accurate" (i.e., will be un-biased, and will have a measurement uncertainty equal to 0.00...0 db). Thus, this set of "perfect" measurements would be the "true" values of the emissions from that PT Test Artifact. If these "Perfect Results" could then be compared to actual PT results obtained by real (i.e., imperfect) Test Operators using real (i.e., imperfect) test instrumentation on a real OATS or in a real RF Anechoic Chamber, it would be a relatively simple matter to determine the "quality" of each set of actual PT results. Of course, there are no "Perfect Test Operators" and there are no "Perfect Test Labs". So, the first thing that needs to be done in a Proficiency Test is to use the measurements collected by each participating Test Lab for each of the types of measurements made (e.g., Antenna Port Conducted Emissions, Radiated Average Emissions at 3 m in Horizontal Polarization, etc.) at each RF Frequency (e.g., 1 GHz, 2 GHz, etc.) to determine a set of estimates of the "true" values, and, to determine the amount of error inherent (i.e., the uncertainty) in each such estimate. Without going into a lot of detail, the estimates of the "true" values are best determined using some kind of averaging technique to determine the central tendency of the data. The use of a simple arithmetic mean (of the data) readily suggests itself. Unfortunately, the results of simple arithmetic mean calculations are severely affected by "outliers". (Note: an "outlier" is a measurement that has a value that is significantly larger or smaller than most of the other measurements in the same PT Data Set). The results of simple arithmetic mean calculations are even more significantly affected by measurements that are bi-modal or tri-modal. (All three of these conditions are common in Antenna Conducted Emissions and Radiated Emissions PT Data Sets). What is actually needed to determine the central tendency of the PT data is some kind of weighted averaging technique that is not very sensitive to "outliers", and to bi-modal or tri-modal data distributions. Statisticians call such techniques "Robust". Appendix C.3 of the ISO 13528:2015 Standard contains an iterative algorithm (the socalled "Algorithm A") that produces a robust estimate of central tendency called the "ISO 13528 Algorithm A Robust Average". Hereafter we refer to the result (i.e., the statistic) obtained by inputting measured PT Data (collected at a specific RF Frequency from a specific PT Data Set) into the "ISO 13528 Algorithm A" as the Robust Average, and it will hereafter be denoted as X*). As might be expected, the use of the "ISO 13528 Algorithm A" also produces a statistic that is a measure of the dispersion (i.e., "spread") of the PT data. This statistic, denoted as S*, is the Standard Deviation of the Robust Average. [Note: S* is often called the Robust Standard Deviation]. Additionally, and very importantly, the "ISO 13528 Algorithm A Robust Average" technique also produces a statistic called u x, which is the (derived) Uncertainty of the Robust Average (i.e., of X*). This uncertainty value (i.e., u x ) depends on both S* and the number of participants (denoted as "p").

Part 2: Procedure for the computation of the Performance Statistics (i.e., X*, S* & u x ) As stated above in Part 1 of this tutorial, in all ACE-PT Inc.'s PT Schemes, the Assigned Values (X*s) are to be determined in accordance with Clause 7.7 "Consensus value from participants" of ISO 13528:2015, using the iterative algorithm (the so-called "Algorithm A") detailed in Appendix C.3 of the ISO 13528:2015 Standard. Using the "ISO 13528 Algorithm A", X*, S* and, u x, are calculated for each RF Frequency in each PT Data Set. Thus, if a particular PT Data Set in a given "Round" of a given PT Scheme (say, the Direct Peak Antenna Conducted Emissions PT Data Set from an Initial Round using a particular PT Test Artifact) had 10 RF Frequencies at which measurements were made, then 10 sets of X*, S*, and, u x values will be calculated by the algorithm - one set of X*, S*, and, u x values for each RF Frequency in that PT Data Set. In ISO 13528:2015, the term "Assigned Value" is defined as a: "value attributed to a particular property of a proficiency test item". In a more general sense, the term "Assigned Value" can also be understood as a value attributed to a particular quantity and accepted, sometimes by convention, as having an uncertainty appropriate for a given purpose. In accordance with Clause 7.7 "Consensus value from participants" of ISO 13528:2015, for the purposes of all of ACE-PT Inc.'s PT Schemes, we have chosen to denote the Robust Average, X*, as the Assigned Value. This means that we use X* as our best estimate of the "true value" (which is unknown and is unknowable), and we use u x as the derived Uncertainty of the Assigned Value (i.e., of X*). What this means in practice is that the idea of a "true value" (i.e., a "perfect measurement") has been replaced with the idea of an "estimate of the true value" that has a non-trivial Uncertainty associated with it (and, that we cannot ignore this Uncertainty of the estimate of the "true value"). The calculations of X* and S*, using the "ISO 13528 Algorithm A" is an iterative process. Typically between three (3) and six (6) separate iterations of the algorithms are required in order to achieve a properly converged solution (i.e., a solution where the X*, and, S* values are identical between iterations to at least the second decimal place, and preferably to the third decimal place). [Note: it is ACE-PT Inc.'s standard practice to carry out six iterations of the algorithms in all cases. This conservative practice serves to simplify the setup of the spreadsheets, because the number of iterations is always constant]. Consequently, a set of custom-designed spreadsheets and plots were developed in order to mechanize the extremely large number of calculations that result from the use of the "ISO 13528 Algorithm A". All of these customdesigned spreadsheets and plots were developed by ACE-PT Inc.'s Senior Statistician in close consultation with the ACE-PT Inc. PT Technical Manager. The spreadsheets and plots were produced using Microsoft Excel 2007. The computations contained in the spreadsheets have been validated by using the PT data set "d1", the contents of which are listed in the leftmost column of Table 2 of the previous version of ISO 13528 (i.e., ISO 13528:2005). The results of this validation exercise matched those provided at the bottom of Table 2 of ISO 13528:2005 to within two decimal places for the value of X* and within one decimal place for the value of S*. The differences, which were not numerically significant, were due to the fact that the calculations were performed using Microsoft Excel 2007, which employs IEEE Standard 754 floating point arithmetic with 15 digits of precision, whereas the calculations used to produce the values at the bottom of Table 2 of the previous version of ISO 13528 (i.e., ISO 13528:2005) were performed using fixed point arithmetic. [Note: When iterative calculations are performed in floating point arithmetic, the representational and rounding errors propagate through each iteration, whereas calculations performed in fixed point arithmetic (e.g. hand calculations) do not suffer such errors]. The numerous other calculations (viz. the Z-Scores, the Control Limits, etc.) were validated by as series of spot-checked hand calculations.

Part 3: Procedure for the Computation of the Performance Evaluation Parameters (i.e., the Control Limits) in db Units It is a practical necessity to analyze each PT Data Set in such a manner that the results are expressed in the original db units of measure (i.e., in dbμv units or in dbμv/m units, as applicable) and the Control Limits are also expressed in the original db units of measure (i.e., dbμv units or dbμv/m units, as applicable). This procedure is highly desirable because most EMC and Wireless/RF Test personnel will find it easier to understand their PT results if those results are expressed in the "natural" units (i.e., dbμv or dbμv/m, as applicable) used to collect the data. For all of ACE-PT Inc.'s current PT Schemes, when using db units (i.e., either dbμv or dbμv/m as applicable), each Upper Control Limit [UCL] and each Lower Control Limit [LCL] will be calculated as follows: UCL = X* + (U p + u x ) LCL = X* - (U p + u x ) X* is the Robust Average derived using Algorithm A from ISO 13528; and, U p is a prescribed measurement uncertainty that is treated as having a fixed value (i.e., is a constant) for a specific PT Test Process in a given round of Proficiency Testing; and, u x is the standard measurement uncertainty for the Assigned Value (i.e., X*) for a specific PT Test Process being examined in a given round of Proficiency Testing. Note 1: For PT Schemes based on normative commercial EMC and Wireless/RF Test Method Standards such as ANSI C63.10-2013 and/or ANSI C63.4-2014, the prescribed Up values are obtained from the applicable expanded measurement uncertainties for a k=2 coverage factor (corresponding to approximately 95% confidence) that are to be found in normative standards such as CISPR 16-4-2 or ETSI TR 100 028. Regardless of the source of the prescribed U p values, they are always treated as fixed values (constants) for a specific PT Test Process being examined in a given round of Proficiency Testing. Note 2: In the computation procedures described above, the computed UCL and LCL values are fixed thresholds for performance evaluation for a specific PT Test Process being examined in a given round of Proficiency Testing. Each UCL and LCL consists of two component parts one part from the prescribed test methods (i.e., U p - which is treated as a fixed value [constant] for each measured frequency in a given data set from a given round), relaxed by adding the second part, u x [i.e., the uncertainty value of the assigned value (X*)]. Note: u x is treated as a constant within each measured frequency and as a variable for the different measured RF Frequencies in a given Data Set from a given round of Proficiency Testing. It is important to note here that the MU (i.e., U p ) values given in CISPR 16-4-2 are for a coverage factor k=2, corresponding approximately to a 95% Confidence Interval, whilst the MU (i.e., U p ) values given in ETSI TR 100 028 V1.4.1 are stated for a coverage factor of k=1.96. ACE-PT Inc. has chosen to follow the now universal practice in the commercial EMC and Wireless/RF Testing Community - i.e., to employ the MU (i.e., U p ) values for a k=2 coverage factor in all cases. [Note: The MU (i.e., U p ) values in ETSI TR 100 028 V1.4.1 are easily transformed from their k=1.96 to a k=2 coverage factor]. In Clause 9.2 "Limiting the uncertainty of the assigned value" of ISO 13528:2015, it is noted that if u x > 0.3S*, then the uncertainty of the assigned value is NOT negligible. Because of this, and in accordance with Clause 9.2.1 of ISO 13528:2015, we have chosen in all cases to use the uncertainty of the assigned value in the interpretation of the proficiency testing. Part 4: Applicable U p Values for ANSI C63.10-based and ANSI C63.4-based PT Schemes CISPR 16-4-2:2003-11, CISPR 16-4-2:2011-06 + A1:2014-02, ETSI TR 100 028-1 V1.4.1, and ETSI TR 100 028-2 V1.4.1 are all extremely lengthy documents that address the Measurement Uncertainty MU (U p ) values for a great many kinds of EMC and Wireless/RFR measurements. However, the measurements addressed by ACE-PT Inc. s PT Schemes have the following MU values (i.e., U p = U CISPR (k=2) or U p = U ETSI TR 100 028 (k=2) ): - for Antenna Port Conducted Emissions from 150 khz to 30 MHz: U p = U ETSI TR 100 028-1(k=2) = 4.10 db. - for Antenna Port Conducted Emissions from 30 MHz to 1000 MHz: U p = U ETSI TR 100 028-1(k=2) = 4.10 db. - for Antenna Port Conducted Emissions from 1 GHz to 18: U p = U ETSI TR 100 028-1(k=2) = 4.10 db.

- for Radiated Emissions in all ANSI C63.4 PT Schemes at 3 m in Horizontal Polarization from 30 MHz to 1000 MHz in either a Semi-Anechoic Chamber or on an OATS: U p = U CISPR (k=2) = +/- 5.06 db from 30 MHz to 200 MHz, and, U p = U CISPR (k=2) = 5.24 db from 200 MHz to 1000 MHz. - for Radiated Emissions in all ANSI C63.4 PT Schemes at 3 m in Vertical Polarization from 30 MHz to 1000 M Hz in either a Semi-Anechoic Chamber or on an OATS: U p = U CISPR (k=2) = 5.07 db from 30 MHz to 200 MHz, and U p = U CISPR (k=2) = 5.26 db from 200 MHz to 1000 MHz. - for Radiated Emissions in all ANSI C63.4 PT Schemes at 10 m in Horizontal Polarization from 30 MHz to 1000 M Hz in either a Semi-Anechoic Chamber or on an OATS: U p = U CISPR (k=2) = 5.05 db from 30 MHz to 200 MHz, and U p = U CISPR (k=2) = 5.21 db from 200 MHz to 1000 MHz. - for Radiated Emissions in all ANSI C63.4 PT Schemes at 10 m in Vertical Polarization from 30 MHz to 1000 M Hz in either a Semi-Anechoic Chamber or on an OATS: U p = U CISPR (k=2) = 5.03 db from 30 MHz to 200 MHz, and, U p = U CISPR (k=2) = 5.22 db from 200 MHz to 1000 MHz. - for Radiated Emissions in all ANSI C63.4 PT Schemes from 1 GHz to 18 GHz at 3 m in an Fully Anechoic Room [FAR] or on a Free-Space OATS: U p = U CISPR (k=2) = 5.18 db from 1 GHz to 6 GHz; U p = U CISPR (k=2) = 5.48 db from 6 GHz to 18 GHz. Part 5: Performance Evaluation (Pass/Fail) using UCLs & LCLs computed in db Units The participant s results are evaluated by comparing each participating Test Laboratory s measurements (results) with the computed UCL and LCL values. Any measurements which are between the Upper Control Limit [UCL] and the Lower Control Limit [LCL] are defined as being "acceptable" measurements and are therefore deemed to have Passed. Any measurements which are either above the Upper Control Limit [UCL] or are below the Lower Control Limit [LCL] are defined as being Unacceptable Measurements. Unacceptable Measurements are also defined to be outliers and are therefore deemed to have "Failed". In other words, the Pass/Fail performance criteria are as follows: LCL X i UCL PASS X i > UCL FAIL on the hot side (i.e., the measurement had a higher value than the UCL) X i < LCL FAIL on the cold side (i.e., the measurement had a lower value than the LCL) X i is the measurement made at the i th RF Frequency in a given PT test in a given "round" of a given PT Scheme. Part 6: Performance Evaluation of Laboratory Measurement Bias using D-Statistics The participant s results are also evaluated by determining an estimate of each participating Test Laboratory s measurement bias. For all of ACE-PT Inc.'s PT Schemes, the Bias (denoted as D ) of the measurement made at the i th RF Frequency in a given PT Data Set from a given "round" of a given PT Scheme shall be determined as follows: D = X i - X* D is the Bias; X i is the measurement made at the i th RF Frequency in a given PT test in a given "round" of a given PT Scheme; X* is the Robust Average derived using Algorithm A from ISO 13528. Bias is most easily visualized by plotting the computed Bias values (for a given PT Data Set) as a function of RF Frequency, with Bias = 0.00 being in the middle of the Y-Axis of each plot. (In other words, the plots will employ a format similar to those used in plotting the Deviations from Zero Normalized Site Attenuation). We suggest (but do not require) that those Test Laboratories whose PT Data exhibit consistently "large" biases (i.e., biases that are consistently > 3 db above or below the applicable values of X*) should attempt to identify the cause of such measurement biases. Each participant s Bias values are then evaluated against the Test Method/Procedure Uncertainty (U p ) relaxed by adding the second part, u x [i.e., the uncertainty value of the assigned value (X*)] as follows:

D = X i X* (U p + u x ) PASS D = X i X* > (U p + u x ) FAIL D is the Measurement Bias. Part 7: Evaluation of results using Z-Scores and Standardized Control Limits (Z LCL & Z UCL ) The participant s results are also evaluated by employing an alternative (equivalent) method that standardizes each participating Test Laboratory s Bias (i.e., D = Xi X*) and the corresponding computed LCL and UCL values. The performance evaluation of the participants is then made by computing their Z-Score values and comparing them with the standardized LCL (Z LCL ) and UCL (Z UCL ) values, as follows: Z-Score = (Xi X*) / S* where: and, Xi is the measurement made at the i th RF Frequency in a given PT test in a given "round" of a given PT Scheme. X* is the Robust Average derived using Algorithm A from ISO 13528. S* is the standard deviation of the assigned value (the Robust Average) for this round of Proficiency Testing. Z UCL (Z-Score for UCL) = UCL/S* Z LCL (Z-Score for LCL) = LCL/S* Note: Care should be taken to avoid confusing the term Z-Score with the term Z-Value. A Z-Score has no underlying assumption of normality (either implicit or explicit), whereas a Z-Value refers to the standardized deviations of a normal distribution. We cannot, on an a priori basis, simply assume normality on collected PT measurement data. In other words, the assumption of normality in the real world EMC and Wireless/RF PT data is erroneous since we can obtain a Z-Score < 2 (or even < 1) and it would be a "FAIL" or a Z-Score >>3 and it would be a "PASS". In this instance, equating (or approximating) the Z-Scores with the Z-Values would lead to giving a "PASS" to participants that should have got a "FAIL" and vice versa. Z-Scores that fall between the applicable Z UCL and the applicable Z LCL are defined as being acceptable measurements, and are deemed to have Passed. Z-Scores that fall above the applicable Z UCL or below the applicable Z LCL are defined as being unacceptable measurements. Unacceptable measurements are defined as outliers and therefore deemed to have "Failed". Thus, Z LCL Z-Score (X i ) Z UCL PASS and, Z-Score (X i ) > Z UCL FAIL on the hot side [i.e., the Z-Score (X i ) had a higher value than Z UCL ] Z-Score (X i ) < Z LCL FAIL on the cold side [i.e., the Z-Score (X i ) had a lower value than Z LCL ]