Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 000000000 600W Power Supply with Single Output RSP-600 series File Name:RSP-600-SPEC 07-09-
600W Power Supply with Single Output RSP-600 series SPECIFICATI MODEL OUTPUT INPUT PROTECTI SAFETY & EMC (Note 6) OTHERS NOTE RSP-600- RSP-600-4 RSP-600-7 DC OLTAGE RATED CURRENT CURRENT RANGE RATED POWER 5A 0 ~ 5A 500W 4 67A 0 ~ 67A 608W 7 59A 0 ~ 59A 593W RIPPLE & NOISE (max.) Note. 50mp-p 00mp-p 00mp-p OLTAGE ADJ. RANGE.5 ~ 5 3.5 ~ 30 6.5 ~ 33.5 OLTAGE TOLERANCE Note.4 ±.0% ±.0% ±.0% LINE REGULATI LOAD REGULATI SETUP, RISE TIME ±0.5% ±0.5% 500ms, 60ms/30AC at full load HOLD UP TIME (Typ.) 6ms / 30AC at 75% load 0ms / 30AC at full load OLTAGE RANGE Note.5 90 ~ 64AC 7 ~ 370DC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) EFFICIENCY (Typ.) 0.97/30AC at full load 89% AC CURRENT (Typ.) Note.5 4A/5AC 8A/30AC 5A/5AC 8.5A/30AC INRUSH CURRENT (Typ.) COLD START 35A/30AC LEAKAGE CURRENT <ma / 30AC OERLOAD OER OLTAGE OER TEMPERATURE OUTPUT OLTAGE PROGRAMMABLE(P) Note 6 EMC EMISSI EMC IMMUNITY 05 ~ 5% rated output power RSP-600-36 36 44.5A 0 ~ 44.5A 60W 50mp-p 35.5 ~ 45 ±.0% RSP-600-48 48 33.5A 0 ~ 33.5A 608W 300mp-p 47.5 ~ 58.8 ±.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% 9.5% 9% 9% 93% Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover 5.75 ~ 8.75 3.5 ~ 37.5 35. ~ 4.9 47. ~ 56.3 63 ~ 75 Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, recovers automatically after temperature goes down Adjustment of output voltage is allowable to ~ 5% of nominal output voltage (60 ~ 5% for ). Please refer to the Function Manual. OUTPUT CURRENT Adjustment of constant current level is allowable to 0 ~ 00% of rated current. PROGRAMMABLE(PC) Note 6 Please refer to the Function Manual. FUNCTI AUXILIARY POWER 5 @ 0.3A, @ 0.8A REMOTE - CTROL By electrical signal or dry contact Power :short Power :open. Please refer to the Function Manual REMOTE SENSE Compensate voltage drop on the load wiring up to 0.5. Please refer to the Function Manual ALARM SIGNAL Isolated signal output for T-alarm and DC OK ENIRMENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY -30 ~ +70 (Refer to "Derating Curve") 0 ~ 90% RH non-condensing - ~ +85, 0 ~ 95% RH non-condensing TEMP. COEFFICIENT IBRATI ± 0.03%/ (0 ~ 50 ) 0 ~ 500Hz, G 0min./cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-, TU EN60950- approved WITHSTAND OLTAGE I/P-O/P:3KAC I/P-FG:KAC O/P-FG:.5KAC ISOLATI RESISTANCE I/P-O/P, I/P-FG, O/P-FG:00M Ohms / 500DC / 5 / 70% RH Parameter Standard Test Level / Note Conducted Radiated Harmonic Current oltage Flicker EN5504, EN604-3, EN6000-6- Parameter ESD Radiated EFT / Burst Surge Conducted Magnetic Field EN5503 (CISPR3) / EN550 (CISPR) Class B EN5503 (CISPR3) / EN550 (CISPR) Class A EN6000-3- Class A EN6000-3-3 ----- Standard EN6000-4- EN6000-4-3 EN6000-4-4 EN6000-4-5 EN6000-4-6 EN6000-4-8 Test Level / Note Level 3, 8K air ; Level, 4K contact Level 3 Level 3 Level 4, K/Line-Line 4K/Line-Earth Level 3 Level 4 >95% dip 0.5 periods, 30% dip 5 periods, oltage Dips and Interruptions EN6000-4- >95% interruptions 50 periods MTBF 60.9K hrs min. Telcordia SR-33 (Bellcore) ; 4.K hrs min. MIL-HDBK-7F (5 ) DIMENSI 300*85*4mm (L*W*H) PACKING.Kg;6pcs/3.6Kg/.03CUFT File Name:RSP-600-SPEC 07-09-
600W Power Supply with Single Output RSP-600 series Block Diagram PFC fosc : 90KHz PWM fosc : 70KHz +S I/P EMI FILTER ACTIE INRUSH CURRENT LIMITING RECTIFIERS & PFC POWER SWITCHING RECTIFIERS & FILTER ORING FET + - PFC CTROL PWM CTROL O..P. DETECTI CIRCUIT ORING FET CTROL -S P/PC TRANSCEIERS DA/DB DETECTI CIRCUIT MCU O.T.P. AUX POWER FAN MCU RECTIFIERS & FILTER /0.8A AUX POWER 5/0.3A DATA ISOLATI T-Alarm DC-OK SDA/SCL or ( CANH/CANL ( Remote - Static Characteristics 00 INPUT MODEL 4 7 36 48 90 80 80~64AC 500W 5A 608W 67A 593W 59A 60W 44.5A 608W 33.5A LOAD (%) 70 60 50 30 90 00 5 80 64 5AC 00AC 90AC 00W 00A 050W 87.5A 900W 75A 86.4W 53.6A 5.6W 46.9A 964.8W.A 74.4W 47.A 5.W 4.3A 955.8W 35.4A 8.6W 35.6A.4W 3.5A 96.W 6.7A 86.4W 6.8A 5.6W 3.45A 964.8W 0.A INPUT OLTAGE (AC) 60Hz Derating Curve LOAD (%) 00 80 60 50 0 30AC Input only -30-5 -0 0 5 30 50 60 70 AMBIENT TEMPERATURE ( ) (HORIZTAL) EFFICIENCY (%) Efficiency vs Load (48 Model) 94 93 9 9 90 89 88 87 86 85 84 83 8 8 0% 0% 30% % 50% 60% 70% 80% 90% 00% LOAD The curve above is measured at 30AC. File Name:RSP-600-SPEC 07-09-
600W Power Supply with Single Output RSP-600 series Function Manual. oltage Drop Compensation. Remote Sense The Remote Sense compensates voltage drop on the load wiring up to 0.5 PIN5 +S PIN6 -S + - LOAD - CN + Sense lines should be twisted in pairs to minimize noise pick-up. The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal.. Local Sense The +S,-S have to be connected to the +(signal), -(signal), respectively, as the following diagram, in order to get the correct output voltage if Remote Sense is not used. + - CN + PIN3 +(signal) PIN5 +S PIN4 -(signal) PIN6 -S - LOAD. Output oltage Programming (or, P / remote voltage programming / remote adjust / margin programming / dynamic voltage trim) In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL OLTAGE. - CN + EXTERNAL OLTAGE (DC) PIN P PIN4 -(signal) out 5 00 OUTPUT OLTAGE(%) 00 60 Others Non-Linear 0 0.4 4.7 5 OUTPUT CURRENT (%) 80 60 0 60 80 00 5 OUTPUT OLTAGE (%) EXTERNAL OLTAGE (DC) The rated current should change with the Output oltage Programming accordingly. For Remote Sense / Local Sense, please refer to oltage Drop Compensation section. File Name:RSP-600-SPEC 07-09-
600W Power Supply with Single Output RSP-600 series 3. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim) The constant current level can be trimmed to 0~00% of the rated current by applying EXTERNAL OLTAGE. Iout 0 00 - CN + EXTERNAL OLTAGE (DC) PIN PC PIN4 -(signal) OUTPUT CURRENT (%) Non-Linear For Remote Sense / Local Sense, please refer to oltage Drop Compensation section. 0 0.4 4.7 5 EXTERNAL OLTAGE (DC) 4. Remote - Control The power supply can be turned / individually or along with other units by using the "Remote -" function. PIN3 +5-AUX switch Between Remote - and +5-AUX Power Supply Status Switch Short PIN4 Remote - Switch Open - CN + 5. Alarm Signal Output There are alarm signals, DC OK and T-ALARM, in TTL signal form, on CN. These signals are isolated from output. The maximum sink current is 0mA. PIN5 DC OK PIN6 T-ALARM Application Circuit - CN + PIN GND-AUX File Name:RSP-600-SPEC 07-09-
600W Power Supply with Single Output RSP-600 series 6.Current Sharing with Remote Sense RSP-600 has the built-in active current sharing function and can be connected in parallel, up to 6 units, to provide higher output power as exhibited below : The power supplies should be paralleled using short and large diameter wiring and then connected to the load. Difference of output voltages among parallel units should be less than 0.. The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(rated current per unit) (Number of unit) 0.9 When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit) (Number of unit) the current shared among units may not be balanced. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 5%. CN500/SW Function pin connection Parallel unit X unit 3 unit 4 unit 5 unit 6 unit PSU PSU PSU3 PSU4 PSU5 PSU6 CN500 SW CN500 SW CN500 SW CN500 SW CN500 SW CN500 SW ( : CN500 connected ; X : CN500 not connected.) RSP-600 RSP-600 RSP-600 RSP-600 RSP-600 RSP-600 PSU PSU PSU3 PSU4 PSU5 PSU6 - - - - - - + TB + TB + TB + TB + TB + TB - + LOAD Fig 5. 3 5 3 5 3 5 3 5 3 5 3 5 DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) DA DB -(signal) 4 6 4 6 4 6 4 6 4 6 4 6 PSU CN500 PSU CN500 PSU3 CN500 PSU4 CN500 PSU5 CN500 PSU6 CN500 If the lines of CN500 are too long, they should be twisted in pairs to avoid the noise. DA,DB and -(signal) are connected mutually in parallel. For Remote Sense / Local Sense, please refer to oltage Drop Compensation section. File Name:RSP-600-SPEC 07-09-
7 8 600W Power Supply with Single Output RSP-600 series Mechanical Specification 30 5.8 5 Case No.50 Unit:mm 9.6.6 -M4 L=5.8 8 0 - CN CN500 3 5 6 LED SW SR I/P 38 0 9 + (Top iew) Air flow direction 85 -ψ 6.5 3 -M4 L=5.8 4 max. 5.8 5 300 70 (Bottom iew) 3-M3 L=4 4.5 6. 7.5 64.7 Mounting Instruction Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque 5 6 M3 M4 6mm 7mm Control Pin No. Assignment( CN) : HRS DF-6DP-DS or equivalent Mating Housing Terminal 6~8Kgf-cm 7~0Kgf-cm HRS DF-6DS or equivalent HRS DF-**SC or equivalent Mounting Surface Mounting Screw Chassis of RSP-600 Pin No. 3 4 5 6 7,8,9 0 3 Function Description +-AUX Auxiliary voltage output, 0.6~3., referenced to GND-AUX (pin). The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by Remote -. GND-AUX Auxiliary voltage output GND. The signal return is isolated from the output terminals (+ & -). +5-AUX Auxiliary voltage output, 4.5~5.5, referenced to GND-AUX (pin). The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by Remote - Remote - The unit can turn the output / by electrical signal or dry contact between Remote / and +5-AUX. (Note.) Short (4.5 ~ 5.5) : Power ; Open (0 ~ 0.5) : Power ; The maximum input voltage is 5.5. High (4.5 ~ 5.5) : When the out 80% ± 5%. DC-OK Low (-0. ~ 0.5) : When out 80% ± 5%. The maximum sourcing current is 0mA and only for output. (Note.) High (4.5 ~ 5.5) : When the internal temperature exceeds the limit of temperature alarm, or when Fan fails. T-ALARM Low (-0. ~ 0.5) : When the internal temperature is normal, and when Fan normally works. The maximum sourcing current is 0mA and only for output(note.) NC For standard model: Retain for future use. A0,A,A For PMBus / CANBus model: PMBus / CANBus interface address lines. (Note.) NC PC P + (Signal) Retain for future use. Connection for constant current level programming. (Note.) Connection for output voltage programming. (Note.) Positive output voltage signal. It is for local sense; it cannot be connected directly to the load. 4 - (Signal) Negative output voltage signal. It is for local sense and certain function reference; it cannot be connected directly to the load. 5 +S Positive sensing for remote sense. 6 -S Negative sensing for remote sense. Note.: Non-isolated signal, referenced to [-(signal)]. Note.: Isolated signal, referenced to GND-AUX. File Name:RSP-600-SPEC 07-09-
600W Power Supply with Single Output RSP-600 series LED Status Indicators LED Green Red Description The power supply functions normally. Abnormal status (Over temperature protection, Overload protection, Fan fail.) AC Input Terminal Pin No. Assignment Pin No. Assignment Diagram Maximum mounting torque 3 FG AC/N AC/L 8Kgf-cm Control Pin No. Assignment( CN500) : HRS DF-8DP-DS or equivalent 7 Mating Housing HRS DF-8DS or equivalent 8 Terminal HRS DF-**SC or equivalent Pin No., 3,4 5,6 7 8 Function DA DB - (Signal) NC SDA CANH NC SCL CANL Description Differential digital signal for parallel control. Differential digital signal for parallel control. Negative output voltage signal. It is for certain function reference; it cannot be connected directly to the load. For standard model: None. For PMBus model: Serial Data used in the PMBus interface. (Note) For CANBus model: Data line used in CANBus interface. (Note) For standard model: None. For PMBus model: Serial Clock used in the PMBus interface. (Note) For CANBus model: Data line used in CANBus interface. (Note) Note: Isolated signal, referenced to GND-AUX. Control Pin No. Assignment(SW) Pin No., Function Terminal resistance Description SW is the selector of terminal resistor that is designed for DA/DB signals and parallel control function. Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:RSP-600-SPEC 07-09-