ISOLATED 4-20 ma TRANSMITTERS

Similar documents
Isolated 4 to 20 ma Transmitters For Demanding Applications Thermocouples, RTD (Pt100) or Ohms, Millivolts, Milliamps, Volts

DRG-SC Series Signal Conditioners

250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

DP2000 ORDERING GUIDE To Order MODEL NO.

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

PANEL MOUNT PROCESS METER IDP

LAUREL ELECTRONICS, INC.

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Two-Wire Programmable Transmitter for:

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

MODEL AT-10 ANALOG TRANSMITTER

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Industrial Modbus I/O Modules

Non-Submersible Industrial Pressure Transducer

Economical Digital Indicators For Process and Electrical Measurement

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

FC Series Signal Conditioners

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

ORDERING INFORMATION T79D

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Installation and Operating Manual

Temperature transmitter itemp PCP DIN rail TMT 121

CSG110 Strain Gauge Universal Amplifier

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

RATE / TOTAL / BATCH METERS INF7

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Miniature Low-Cost Temperature Transmitters MTX

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

itemp HART DIN rail TMT112

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

This Errata Sheet contains corrections or changes made after the publication of this manual.

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

APPA 300 Series. The Most User-Friendly High Performance Multimeter

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

Load Cell Accessories and Services

About Laurel Electronics & FLW, Inc.

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Analog Isolation Amplifiers

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Transducer for Measurement Bridges SCM90, SIGS15

Installation, Operation and Maintenance Manual

EN SERIES NEMA CASED DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Tel: (949) Fax: (949) IAA100 Product Manual

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Data Acquisition Modules/ Distributed IO Modules

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

Analog Isolation Amplifiers

DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT TEL: FAX:

0 2 1 â Ó. itemp HART TMT182. Technical Information

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

SC-FI Series Frequency to Current Signal Conditioner

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

4-20mA, 0-10V and general process measuring bargraph displays

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

WORLD S SMALLEST BARGRAPH METER LOOP OR AC/DC POWERED > 30 INPUT SIGNAL CONDITIONERS

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

Temperature Transmitters - DIN Rail Mounted

PROCESS & TEMPERATURE CONTROLLERS

USB-2404-UI Specifications

MODEL SC170 TWO-WIRE SMART SIGNAL CONDITIONER INSTALLATION AND OPERATION MANUAL

Universal Intelligent 2-wire DIN Rail Transmitters

CONTA-ELECTRONICS. Converter Units

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

ADAM 4000/4100 Series

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

Signet 9900 Transmitter

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

Two Wire Temperature Transmitter LTX-3000-H-2 LTX-3000-H LTX-3000-W LTX-3000-D

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Miniature Temptran RTD Transmitters

Series GLET Accessory for dataloggers series GL in modular enclosure

User s Guide TX91A. (J, K, T, E) 4-20 ma Mini Temperature Transmitter. Shop online at omega.com

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

SENSOTEC, INC Arlingate Lane Columbus, Ohio Phone (614) Facsimile (614) Toll Free Free (800)

Torque Sensor Accessories and Services

Transcription:

500 SERIES FOR DEMANDING APPLICATIONS Isolated to 1500 V rms Two-Wire 4-20 ma Operation 9-50 V Compliance Turndown Ratio to 10:1 NMV Protection to 120 Vac -40 to +85 C (-40 to 185 F) Operation Shock Resistance to 55 g NEMA-4X Metal Case Field-Scalable UNMATCHED ELECTRICAL PERFORMANCE Two-wire Operation Power is obtained directly from the 4-20 ma loop, with no need for separate power input. This simplifies field wiring and eliminates the possibility of noise pickup from power lines. ISOLATED 4-20 ma TRANSMITTERS Custom Scaling Available. Specify input signals corresponding to 4 and 20 ma outputs. NEWPORT PRODUCT INFO MANUAL (HTML) 500 Series QUICK START MECHANICAL PRICE (501, 502A) PRICE (504, 505, 506) PRICE (508B, 509) REQUIRES ADOBE ACROBAT - HELP Isolation to 1500 V rms (2100 Vp) This exceptionally high CMV rating from the input to the case or output eliminates the possibility of electrical ground loops between the signal source and the receiver. It also provides a high degree of protection for the receiver against electrical hazards, such as accidental contact between the signal source and an AC power line. 9-50 V Compliance The loop voltage driving the transmitters can be from 9 to 50 V without loss of accuracy. The exceptionally low 9 V limit allows the transmitters to be used with low loop supply voltages, and it maximizes the voltage drop allowed in the current loop for intrinsic safety barriers and load resistance. For example, at the full 20 ma output of the transmitter, a 750 ohm load can be used with a 24 Vdc source and a 150 ohm load can be used with a 12 Vdc source. In either case, there will still be enough voltage left to power the transmitter, namely 9 Vdc. 10:1 Turndown Ratio Turndown ratio is defined as zero suppression divided by span. The exceptionally high 10:1 turndown ratio possible with the 500 Series indicates that wide zero offset can be combined with narrow signal span for closed loop control at high gain. The signal span can also be wide for control of batch operations, where a wide range of signal levels may be encountered over the entire batch cycle. High Overvoltage Protection Overvoltage of 120 Vac may be applied across the input or output leads for 1 minute in case of all models with voltage or thermocouple input. Reverse polarity of 400 Vp may be applied across the output leads indefinitely. These exceptionally high NMV overvoltage ratings provide further protection against possible electrical faults and wiring errors.

SIGNAL CONDITIONERS / TRANSMITTERS - 500SERIES - PRODUCTS DESIGNED FOR HARSH ENVIRONMENTS Extreme Operating Temperatures The operating temperature can be from -40 C to +85 C (-40 F to +185 F) while meeting published performance specifications. This allows the 500 Series to be used near furnaces or outdoors in the winter. The exceptionally wide operating temperature range is made possible by a proprietary electrical circuit and by extensive use of computer-graded and computer-matched electrical components. Resistant to Shock and Vibration The shock rating is 55 g, which includes a 6-foot drop onto concrete. This is made possible by a compact die-cast metal case, which is only 74 mm (2.9") in diameter, and by rugged mounting of the electronics. The circuit board assembly is in the shape of a rigid box and is firmly soldered to the top of the transmitter case. Waterproof Case The case is made of die-cast zinc alloy. It is waterproof to 35 kpa (5 PSI) and meets NEMA-4X standards. The top of the case is sealed against the bottom with a fluorosilicone gasket, and the openings in the top of the case for the zero and span adjustment are sealed with fluorosilicone plugs. Explosion-proof Housing Options Three external NEMA-7 explosion-proof and NEMA-4 waterproof enclosures are available as options for use in hazardous locations in Class I, Groups B, C, D; and Class II, Groups E, F, G. Option EPH1 is a single-height, all-metal housing for a single 500-Series transmitter. FM and CENELEC EEx d II C certification is standard. Option EPW2 is a double-height metal enclosure with a glass window for a 500-Series transmitter on the bottom and a 508B loop-powered indicator on top. FM and CENELEC EEx d II C certification is standard. The 508B augments the transmitter with an LCD digital readout scaled in engineering units and only adds a modest 2.5 V drop to the current loop. Option EPW3 is a single-height enclosure for one 508B loop-powered indicator. FM and CENELEC EEx d II C certification is standard. EASY TO CALIBRATE AND INSTALL There is no need to specify different models for different ranges of the same signal type. Zero and span are each set by push-on jumpers for coarse range selection and by a 15-turn precision potentiometer for fine adjustment. The two potentiometers are accessible from outside of the case through openings which are normally sealed by fluorosilicone plugs. To assist in calibration, two test terminals provide a 10 mv/ma output (200 mv full-scale). The scaling procedure is documented in a comprehensive user s manual, which is shipped with every unit. Classical Application of a 500 Series 2-Wire Isolated Transmitter The Transmitter amplifies a low-level voltage signal to 4-20 ma current signal, which is immune to voltage noise pick-up. The voltage detected in the control room is V = IR, where I is the loop current and R is the dropping resistor of the receiving equipment. The isolation provided by the transmitter protects the receiving equipment and eliminates the possibility of ground loops between the remote signal ground and the ground of the control room. http://www.newportus.com/products/sgcndtrn/500.htm (2 of 3) [4/13/2000 8:48:42 AM]

SIGNAL OUTPUT Connection: 2-wire Linear Range: 4-20 ma Maximum Output: 35 ma Voltage Compliance: 9-50 Vdc Power Supply Rejection: 0.01% of span/volt COMMON SPECIFICATIONS - ALL MODELS INPUT/OUTPUT PROTECTION CMV, Input to Case or Output: 2100 Vp per HV test, 354 Vp per IEC spacing CMR, Input to Case or Output: 120 db, DC to 60 Hz NMV Across Output Leads: 120 Vac for 1 min Reverse Polarity Across Output Leads: 400 Vp ACCURACY, -40 C to +85 C Hysteresis & Repeatability: ±0.1% of span 6-month Stability Error: ±0.2% of zero suppression Error Due to 50 C Change in Transmitter Temperature: Zero Error: ±0.2% of zero suppression Span Error: ±0.2% of span ENVIRONMENTAL Operating temperature: -40 to +85 C (-40 to +185 F) Storage Temperature: -55 to +125 C (-67 to +257 F) Relative Humidity: 0 to 100% (sealed case) Watertight Proof Pressure: 35 kpa (5 PSI) Shock: 55 g, half sine, 9-13 ms duration Vibration: 1.52 mm (0.06 in) double amplitude, 10-80 Hz cycled MECHANICAL Case Material: Zamak zinc alloy Gasket Material: Fluorosilicone Diameter: 74 mm (2.9 in) Height, Including Barriers: 53 mm (2.1") Weight: 380 g (13 oz) Electrical Connection: #6 screws with wire clamps Terminal Protection: Standard: Screw terminal barriers plus barrier strip cover CPB1 (Optional): Plastic cover for case top (protects T/C screw terminals from air currents) NON-COMMON SPECIFICATIONS

SIGNAL CONDITIONERS / TRANSMITTERS - 500 SERIES - PRODUCTS RTD INPUT - MODEL 501 Signal Source: Pt 100 RTD Span for 4-20 ma Output: 100 to 1050 C (180 to 1890 F) Zero Suppression: -200 to +750 C (-328 to +1382 F) Source Connection: 2- or 3-wire Excitation Current: 200 µa Lead Resistance, Max: 100 ohm Bandwidth: DC-60 Hz OHMS INPUT MODEL 501 Signal Source: 0-400 ohm Span for 4-20 ma Output: 35 to 400 ohm Zero Suppression: 0 to 365 ohm Source Connection: 2- or 3-wire Excitation Current: 200 µa Lead Resistance, Max: 100 ohm Bandwidth: DC-60 Hz THERMOCOUPLE INPUT MODEL 502A Span and Zero Suppression: See input table Input Resistance (Open T/C Detector Resistance): 5 M ohm Bias Current, Max: 50 na NMV Across Input Leads: 120 Vac for 1 min NMR Across Input Leads: 40 db, 50/60 Hz, 100 mv input Thermocouple Lead Resistance: For specified performance: 100 ohm Maximum: 10 kohm Step Response, Type: 400 ms MILLIVOLT INPUT MODEL 504 Span for 4-20 ma Output: 5 to 100 mv Zero Suppression: -30 to +60 mv Input Resistance: 100 M ohm Bias Current, Max: 50 na NMV Across Input Leads: 120 Vac for 1 min NMR Across Input Leads: 40 db, 50/60 Hz, 100 mv input Step Response, Type: 400 ms MILLIAMP INPUT MODEL 505 Span for 4-20 ma Output: 5 to 100 ma Zero Suppression: -30 to +60 ma Input Resistance: 1 ohm Step Response, Type: 400 ms VOLT INPUT MODEL 506 Span for 4-20 ma Output: 0.5 to 5 V (506-1); 5 to 50 V (506-2) Zero Suppression: -3.5 to +6.0 V (506-1); -35 to +60 V (506-2) Input Resistance: 1 M ohm Bias Current, Max: 1 na NMV Across Input Leads: 120 Vac for 1 min NMR Across Input Leads: 40 db, 50/60 Hz, 100 mv input Step Response, Type: 400 ms Quick Selection Guide by Input Type Model 501 Signal Type RTD Pt 100 Ohms Zero Suppression* for 4 Maximum Signal* Signal Span* for 20 ma ma Output for 20 ma Output Output -200 to +750 C -328 to +1382 F 0 to 365 ohm +850 C +1562 F 400 ohm 100 to 1050 C 180 to 1890 F 35 to 400 ohm Input Impedance N/A http://www.newportus.com/products/sgcndtrn/500_2.htm (2 of 3) [4/13/2000 8:48:54 AM]

SIGNAL CONDITIONERS / TRANSMITTERS - 500 SERIES - PRODUCTS 502A-J Type J T/C -50 to +660 C +760 C 100 to 810 C Iron Costantan -58 to +1220 F +1400 F 180 to 1458 F 5 Mohm 502A-K Type K T/C -50 to +1272 C +1372 C 100 to 1422 C Chromel Alumel -58 to +2322 F +2502 F 180 to 2560 F 5 Mohm 502A-T Type T T/C -50 to +350 C +400 C 50 to 450 C Copper -58 to +662 F +752 F 90 to 810 F Costantan 5 Mohm 502A-E Type E T/C -50 to +900 C +1000 C 100 to 1050 C Chromel -58 to +1652 F +1832 F 180 to 1890 F Costantan 5 Mohm 504 Millivolts -30 to +60 mv +160 mv 5 to 100 mv 100 Mohm 505 Milliamps -30 to +60 ma +160 ma 5 to 100 ma 1 ohm 506-1 Low Volts -3.5 to +6.0 V +11 V 0.5 to 5 V 1 Mohm 506-2 High Volts -35 to +60 V +110 V 5 to 50 V 1 Mohm *The signal span shown in column 5 for 4-20 ma output cannot include inputs below the maximum signal in column 4. BACK NEXT Copyright 2000, NEWPORT Electronics, Inc. All rights reserved. http://www.newportus.com/products/sgcndtrn/500_2.htm (3 of 3) [4/13/2000 8:48:54 AM]

DIN RAIL MOUNT PROCESS INPUTS SIGNAL CONDITIONER DRN-PR / DRX-PR Unipolar/Bipolar 400 mv to 10 Vdc, 0-20 ma dc 11-14-Bit Resolution ±0.1% FS Accuracy 14 Vdc Excitation 1800 Volts Isolation 250 Vac/1 Min. Input Overvoltage Protection (Voltage Input Only) Free Setup and Configuration Software Factory Setup and Configuration Available at No Charge (for DRN Analog Output models) NEWPORT PRODUCT INFO MANUAL (HTML) - PDF Version MANUAL (HTML) - PDF Version MECHANICAL PRICE REQUIRES ADOBE ACROBAT - HELP DRN-PR DRX-PR The DRN-PR and DRX-PR signal conditioners provide high accuracy isolated measurement of process signals. For maximum flexibility, the units feature user configurable input types which are fully field scalable. Two models are available, the DRN-PR which provides an analog output that is proportional to the input signal and the DRX-PR which uses a digital RS-485 communication link. Both models can accept unipolar and bipolar signals from 400 mv to 10 Vdc full scale. A 0 to 20 ma current range is also available. The DRN/DRX-PR also contains a 14 Vdc reference voltage which may be used for transducer excitation. The output of DRN-PR can be user set for 0 to 10 V, 4 to 20 ma or 0 to 20 ma. Input scaling and configuration of other operating parameters is accomplished by connecting to a standard RS-232 port of a personal computer and using the DRN-CONFIG, Windows-based setup software. Once configured the settings may be stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge To make your installation even easier, your DRN (Analog Output and RS-232) signal conditioners can be ordered preconfigured by the factory at no extra charge. You select the input types, ranges and output scale and we will program the instruments to your specific requirements in our calibration lab prior to shipment. For custom factory setup and scaling of the DRN model, please specify the -FS option. Please Specify: Input Value High & Low Output Value High & Low Excitation: 10 or 14 Volts dc Ratiometric or Non-Ratiometric

Process Instrumentation * DRN-PR / DRX-PR Example: 0 V = 4 ma, 10 V = 20 ma, Excitation 10 V, Non-Ratiometric The DRX-PR is a digital signal conditioner which communicates over an RS-485 communication link using either Omega Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 4,000 ft. Through the use of RS-485 repeaters, additional modules may be used and further transmission distances are achievable. Free Active X Controls Free Active X Controls are provided for the DRN/DRX series Signal Conditioners. This free software makes it easy to integrate the "i Series" with "Active X Containers" such as Microsoft Visual Basic as well as with popular OLE compliant data acquisition, process control, and industrial automation software from OMEGA as well as Wonderware, Intellution, Rockwell Automation, and Object Automation among others. SPECIFICATIONS Accuracy at 25 C: ±0.1% FS Resolution: 11 to 14 bit Excitation: 14 VDC @ 25mA Power Consumption: 2 W (84 Ma @ 24 vdc) without excitation (100 ma @ 24 Vdc), 3 W with excitation (125 ma @ 24 Vdc) Input Ranges: Uni/bipolar, 400 mv to 10 Vdc; 0 to 20 ma full DRX Output: 2-wire (half duplex) RS-485 DRN Output: 0 to 10 V @ 10 ma max; 0 to 20 ma or 4 to 20 ma, 10 V compliance Process Default settings DRN: Input Range 0-20mA; Output 4-20mA. Excitation 14V (Custom Settings available at no charge.) To Order (Specify Model No.) Prices Shown in U.S. Dollars Model No. Description Price DRX-PR Digital signal conditioner for strain gages and bridge transducers with RS-485 output $275 DRN-PR Signal conditioner for strain gages and bridge transducers with analog output $325 -FS Factory setup and scaling FREE Each unit supplied with complete operator s manual. Ordering Example: DRX-PR digital signal conditioner with RS-485 output for process signals ($275), plus DRN-PS-750 power supply, 115 Vac input, 24 Vdc output @ 750 ma ($130), $275 + 130 = $405. ACCESSORIES Model No. Description Price DRN-RS232-SW Configuration Software for DRN DRX-RS485-SW Configuration Software for DRX FREE DB9-RJ12 DB9 TO RJ12 Connector Adaptor includes 7 ft, DB25-RJ12 DB25 to RJ12 Connector Adaptor RJ12 Cord $30 DRN-PS-750 Power supply, 115 Vac input, 24 Vdc output @ 750 ma $130 DRN-PS-1000 Switching Power supply, 95-240 Vac input, 24 Vdc output @850mA $150 CAT-285 Bi-directional RS-232-RS-485 converter for DRX series $148 *Specify "9" for 9-pin or "25" for 25-pin serial cable. Copyright 2000, NEWPORT Electronics, Inc. All rights reserved. http://www.newportus.com/products/process/drn_pr.htm (2 of 2) [4/13/2000 8:35:02 AM]

AC VOLTAGE / CURRENT SIGNAL CONDITIONERS DIN RAIL MOUNT DRN-ACC / ACV & DRX-ACC / ACV Software Selectable Input Ranges DRX-ACV: 0-400 mv to 0 to 400 Vac DRX-ACC: 0-10 ma to 0-5 A ac 14-Bit Resolution (max) 0.2% FS Accuracy 1800 V Isolation Free Setup and Configuration Software Factory Setup and Configuration Available at No Charge (for DRN Analog Output models) NEWPORT PRODUCT INFO MANUAL (HTML) DRN-ACC MANUAL (HTML) DRN-ACV MANUAL (HTML) - PDF Version MANUAL (HTML) - PDF Version MECHANICAL PRICE REQUIRES ADOBE ACROBAT - HELP DRX-ACC DRX-ACV The DRN/DRX Series signal conditioners provide high accuracy isolated measurement of ac voltage and current signals. For maximum flexibility, the units feature user configurable input types which are fully field scalable. Four models are available, the DRN-ACV and DRN-ACC accept ac voltage and ac current respectively and provide an analog output which is proportional to the input. The DRX-ACV and DRX-ACC accept ac voltage and ac current respectively and provide a digital RS-485 communication link. The DRN-ACC and DRX-ACV can accept ac currents from 0 to 10 ma to 0 to 5 A ac. The DRX-ACV and DRN-ACV can accept ac voltages from 0 to 400 mv to 0 to 400 Vac. The output of DRN-ACC and DRN-ACV can be user set for 0 to 10 V, 4 to 20 ma or 0 to 20 ma. Input scaling and configuration of other operating parameters is accomplished by connecting to a standard RS-232 port of a personal computer and using the DRN-RS232-SW, Windows-based setup software. Once configured the settings may be stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge To make your installation even easier, your DRN (Analog Output and RS-232) signal conditioners can be ordered preconfigured by the factory at no extra charge. You select the input types, ranges and output scale and we will program the instruments to your specific requirements in our calibration lab prior to shipment. For custom factory setup and scaling of the DRN model, please specify the -FS option. Please Specify: DRN-ACV: Input Value High & Low Output Value High & Low Example: 0 volts = 4 ma, 400Vac = 20 ma DRN-ACC: Input Value High & Low Output Value High & Low Example: 0 A = 4 ma, 5 A = 20 ma

DRN-ACC/DRN-ACV & DRX-ACC/DRX-ACV - AC Voltage/Current Signal Conditioners The DRX-ACC and DRX-ACV are digital signal conditioners which communicate over an RS-485 communication link using either Omega Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 4,000 ft. Through the use of RS-485 repeaters, additional modules may be used and further transmission distances are achievable. Free Active X Controls Free Active X Controls are provided for the DRN/DRX series Signal Conditioners. This free software makes it easy to integrate the "i Series" with "Active X Containers" such as Microsoft Visual Basic as well as with popular OLE compliant data acquisition, process control, and industrial automation software from OMEGA as well as Wonderware, Intellution, Rockwell Automation, and Object Automation among others. SPECIFICATIONS Accuracy at 25 C: ±0.2% FS Resolution: 10 to 14 bit Power Consumption: 2.4 W; 100 ma @ 24 Vdc MODEL DRX-ACV/DRN-ACV Input Ranges: 0 to 400 mv to 0 to 400 Vac full scale Interface: RS-485; RJ-12 or screw terminal connector MODEL DRX-ACC/DRN-ACC Input Ranges: 0 to 10 ma to 0 to 5 A ac full scale DRX Output: 2-wire (half duplex) RS-485 DRN Output: 0 to 10V @ 10 ma max; 0 to 20 ma or 4 to 20 ma ACV Default settings DRN: Input 0-400 VAC; Output 4-20 ma (Custom Settings available at no charge.) ACC Default settings DRN: Input 0-5 Amp; Output 4-20 ma (Custom Settings available at no charge.) To Order (Specify Model No.) Prices Shown in U.S. Dollars Model No. Description Price DRX-ACC Digital signal conditioner with RS-485 output for ac current inputs $270 DRX-ACV Digital signal conditioner with RS-485 output for ac voltage inputs $270 DRN-ACC Signal conditioner with analog output for ac current inputs $345 DRN-ACV Signal conditioner with analog output for ac voltage inputs $345 -FS Factory setup and scaling FREE Each unit supplied with complete operator s manual. Ordering Example: DRX-ACV digital signal conditioner with RS-485 output for ac voltage inputs ($270), plus DRN-PS-750 power supply, 115 Vac input, 24 Vdc output @ 750 ma ($130), $270 + 130 = $400. ACCESSORIES Model No. Description Price DRN-RS232-SW Configuration Software for DRN DRX-RS485-SW Configuration Software for DRX FREE DB9-RJ12 DB9 TO RJ12 Connector Adaptor includes 7 ft, DB25-RJ12 DB25 to RJ12 Connector Adaptor RJ12 Cord $30 DRN-PS-750 Power supply, 115 Vac input, 24 Vdc output @ 750 ma $130 DRN-PS-1000 Switching Power supply, 95-240 Vac input, 24 Vdc output @850mA $150 CAT-285 Bi-directional RS-232-RS-485 converter for DRX series $148 *Specify "9" for 9-pin or "25" for 25-pin serial cable. Copyright 2000, NEWPORT Electronics, Inc. All rights reserved. http://www.newportus.com/products/acurrvol/drn_acc.htm (2 of 2) [9/1/2000 2:21:18 PM]

DIN RAIL MOUNT PROCESS INPUTS SIGNAL CONDITIONER DRN-PR / DRX-PR Unipolar/Bipolar 400 mv to 10 Vdc, 0-20 ma dc 11-14-Bit Resolution ±0.1% FS Accuracy 14 Vdc Excitation 1800 Volts Isolation 250 Vac/1 Min. Input Overvoltage Protection (Voltage Input Only) Free Setup and Configuration Software Factory Setup and Configuration Available at No Charge (for DRN Analog Output models) NEWPORT PRODUCT INFO MANUAL (HTML) - PDF Version MANUAL (HTML) - PDF Version MECHANICAL PRICE REQUIRES ADOBE ACROBAT - HELP DRN-PR DRX-PR The DRN-PR and DRX-PR signal conditioners provide high accuracy isolated measurement of process signals. For maximum flexibility, the units feature user configurable input types which are fully field scalable. Two models are available, the DRN-PR which provides an analog output that is proportional to the input signal and the DRX-PR which uses a digital RS-485 communication link. Both models can accept unipolar and bipolar signals from 400 mv to 10 Vdc full scale. A 0 to 20 ma current range is also available. The DRN/DRX-PR also contains a 14 Vdc reference voltage which may be used for transducer excitation. The output of DRN-PR can be user set for 0 to 10 V, 4 to 20 ma or 0 to 20 ma. Input scaling and configuration of other operating parameters is accomplished by connecting to a standard RS-232 port of a personal computer and using the DRN-CONFIG, Windows-based setup software. Once configured the settings may be stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge To make your installation even easier, your DRN (Analog Output and RS-232) signal conditioners can be ordered preconfigured by the factory at no extra charge. You select the input types, ranges and output scale and we will program the instruments to your specific requirements in our calibration lab prior to shipment. For custom factory setup and scaling of the DRN model, please specify the -FS option. Please Specify: Input Value High & Low Output Value High & Low Excitation: 10 or 14 Volts dc Ratiometric or Non-Ratiometric

Process Instrumentation * DRN-PR / DRX-PR Example: 0 V = 4 ma, 10 V = 20 ma, Excitation 10 V, Non-Ratiometric The DRX-PR is a digital signal conditioner which communicates over an RS-485 communication link using either Omega Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 4,000 ft. Through the use of RS-485 repeaters, additional modules may be used and further transmission distances are achievable. Free Active X Controls Free Active X Controls are provided for the DRN/DRX series Signal Conditioners. This free software makes it easy to integrate the "i Series" with "Active X Containers" such as Microsoft Visual Basic as well as with popular OLE compliant data acquisition, process control, and industrial automation software from OMEGA as well as Wonderware, Intellution, Rockwell Automation, and Object Automation among others. SPECIFICATIONS Accuracy at 25 C: ±0.1% FS Resolution: 11 to 14 bit Excitation: 14 VDC @ 25mA Power Consumption: 2 W (84 Ma @ 24 vdc) without excitation (100 ma @ 24 Vdc), 3 W with excitation (125 ma @ 24 Vdc) Input Ranges: Uni/bipolar, 400 mv to 10 Vdc; 0 to 20 ma full DRX Output: 2-wire (half duplex) RS-485 DRN Output: 0 to 10 V @ 10 ma max; 0 to 20 ma or 4 to 20 ma, 10 V compliance Process Default settings DRN: Input Range 0-20mA; Output 4-20mA. Excitation 14V (Custom Settings available at no charge.) To Order (Specify Model No.) Prices Shown in U.S. Dollars Model No. Description Price DRX-PR Digital signal conditioner for strain gages and bridge transducers with RS-485 output $275 DRN-PR Signal conditioner for strain gages and bridge transducers with analog output $325 -FS Factory setup and scaling FREE Each unit supplied with complete operator s manual. Ordering Example: DRX-PR digital signal conditioner with RS-485 output for process signals ($275), plus DRN-PS-750 power supply, 115 Vac input, 24 Vdc output @ 750 ma ($130), $275 + 130 = $405. ACCESSORIES Model No. Description Price DRN-RS232-SW Configuration Software for DRN DRX-RS485-SW Configuration Software for DRX FREE DB9-RJ12 DB9 TO RJ12 Connector Adaptor includes 7 ft, DB25-RJ12 DB25 to RJ12 Connector Adaptor RJ12 Cord $30 DRN-PS-750 Power supply, 115 Vac input, 24 Vdc output @ 750 ma $130 DRN-PS-1000 Switching Power supply, 95-240 Vac input, 24 Vdc output @850mA $150 CAT-285 Bi-directional RS-232-RS-485 converter for DRX series $148 *Specify "9" for 9-pin or "25" for 25-pin serial cable. Copyright 2000, NEWPORT Electronics, Inc. All rights reserved. http://www.newportus.com/products/process/drn_pr.htm (2 of 2) [4/18/2000 7:49:44 AM]

MECHANICAL REFERENCE - SIGNAL CONDITIONERS DRN/DRX SIGNAL CONDITIONERS DRN / DRX DIN RAIL MOUNT (32mm or 35mm) ( FRONT VIEW ) http://www.newportus.com/products/mechancl/m2.htm (1 of 4) [9/5/2000 3:29:38 PM]

MECHANICAL REFERENCE - SIGNAL CONDITIONERS DRN/DRX (SIDE VIEW) 1.0 http://www.newportus.com/products/mechancl/m2.htm (2 of 4) [9/5/2000 3:29:38 PM]

MECHANICAL REFERENCE - SIGNAL CONDITIONERS DRN/DRX http://www.newportus.com/products/mechancl/m2.htm (3 of 4) [9/5/2000 3:29:38 PM]

MECHANICAL REFERENCE - SIGNAL CONDITIONERS DRN/DRX Copyright 2000, NEWPORT Electronics, Inc. All rights reserved. http://www.newportus.com/products/mechancl/m2.htm (4 of 4) [9/5/2000 3:29:38 PM]

MECHANICAL REFERENCE - THERMOWELL HEAD TRANSMITTER MTX THERMOWELL HEAD TRANSMITTER MTX http://www.newportus.com/products/mechancl/m18.htm (1 of 2) [9/5/2000 3:31:56 PM]

MECHANICAL REFERENCE - THERMOWELL HEAD TRANSMITTER MTX Copyright 2000, NEWPORT Electronics, Inc. All rights reserved. http://www.newportus.com/products/mechancl/m18.htm (2 of 2) [9/5/2000 3:31:56 PM]

MECHANICAL REFERENCE- LOOP TRANSMITTER INDICATORS LOOP TRANSMITTERS INDICATORS http://www.newportus.com/products/mechancl/m24_25.htm (1 of 3) [9/5/2000 3:32:05 PM]

MECHANICAL REFERENCE- LOOP TRANSMITTER INDICATORS http://www.newportus.com/products/mechancl/m24_25.htm (2 of 3) [9/5/2000 3:32:05 PM]