Sub-cooled SFCL Device and Modules for Power Transmission / Distribution

Similar documents
Superconducting Fault Current Limiter Modules for Power Transmission / Distribution

Recent Development of SFCL in the USA

Fault Current Limiter Selection Considerations for Utility Engineers

INNOVATIVE PERSPECTIVES FOR ELECTRICITY TRANSPORT

KIT-ENERGY CENTRE. KIT The research University in the Helmholtz Association

DEVELOPMENT OF A TEST PROTOCOL FOR A 15 KV CLASS SOLID-STATE CURRENT LIMITER

Resistive and Inductive Fault Current Limiters: Kinetics of Quenching and Recovery

Standards Developments for Fault Current Limiters

Lumped Network Model of a Resistive Type High T c fault current limiter for transient investigations

Past CIGRE and Emerging IEEE Guide Documents on FCLs

FIELD DEMONSTRATION OF WORLD WIDE LARGEST SUPERCONDUCTING FAULT CURRENT LIMITER AND NOVEL CONCEPTS

Ein supraleitender Strombegrenzer für die Energieübertragung

Markus Abplanalp, 7. Braunschweiger Supraleiterseminar, Strombegrenzerkonzepte im Vergleich

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

DEMO 5: HVDC Superconducting Link

The Results of the KSTAR Superconducting Coil Test

A 100 MJ SMES Demonstration at FSU-CAPS

The HIL Based Model Validation Paradigm - Tools, Challenges, and Application Examples

TRANSFORMER TECHNOLOGY GPT

HTS PARTIAL CORE TRANSFORMER- FAULT CURRENT LIMITER

A Glance into the Future of Transformers and Beyond

Recent Results in 2G HTS Wire Technology Development at SuperPower

Mosca-Genova: SMART CITY futuro o realtà?

MATEFU Insulation co-ordination and high voltage testing of fusion magnets

Study of Design of Superconducting Magnetic Energy Storage Coil for Power System Applications

conductors by striation and selective electroplating

Verification Testing for a 1 MVA 3-Phase Demonstration Transformer Using 2G-HTS Roebel Cable

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems

Development of CORC cables for helium gas cooled power transmission and fault current limiting applications

PERFORMANCE ANALYSIS OF SURGE CURRENT PROTECTION USING SUPERCONDUCTORS

Current limiting characteristic of saturated iron core SFCLs

Saturated Core Fault Current Limiters: successful testing/ service performance

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

Design considerations in MgB2-based superconducting coils for use in saturated-core fault current limiters

TECHNICAL SPECIFICATIONS. FOR AN MRBR 7.0 TESLA / 160mm ACTIVELY SHIELDED ROOM TEMPERATURE BORE MAGNET SYSTEM

28/11/2016 Juan Carlos Perez TE-MSC-MDT Jose Ferradas TE-MSC-MDT

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

A Pyrotechnic Fault Current Limiter Model for Transient Calculations in Industrial Power Systems

ANALYSIS OF FAULTS INTERRUPTED BY GENERATOR

(2) New Standard IEEE P (3) Core : (4) Windings :

Insulation Co-ordination For HVDC Station

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

2. Composing and characteristics of EAST

High-Voltage Test Techniques

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Simulation of HTS saturable core-type FCLs for MV distribution systems

Minimizing of Fault Current Using SFCL Technology

Millikelvin measurement platform for SQUIDs and cryogenic sensors

INCREASING THE POWER SYSTEM SWITCH GEAR CAPACITY BY USING SUPERCONDUCTING FAULT CURRENT LIMITER

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

Cryogenic Testing of Superconducting Corrector Magnets for the LHC Main Dipole

Poornima G P. IJECS Volume 3 Issue 6 June, 2014 Page No Page 6453

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

Analysis of Superconducting Fault Current Limiter in DC System with Renewable Energy Sources

General Technical Specifications of Frequency Converters for Tokyo-Chubu Interconnection Project

EFFECT OF SFCL ON DISTRIBUTION POWER QUALITY

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Brett Parker, representing the

Progress Report on Failures of High Voltage Bushings with Draw Leads By Jim McBride and Larry Coffeen, JMX Services / NEETRAC 7/26/2010

2.3 PF System. WU Weiyue PF5 PF PF1

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

3.7 Grounding Design for EAST Superconducting Tokamak

FAULT CURRENT LIMITERS PRINCIPLES AND APPLICATION

International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July ISSN

Power System Transient Stability Enhancement by Coordinated Control of SMES, SFCL & UPFC

Operational Experiences of an HV Transformer Neutral Blocking Device

SYSTEM STUDIES for HVDC

Generation of Sub-nanosecond Pulses

Superconducting Fault Current Limiter for Energy Storage Protection in a Micro Grid

Ritz Instrument Transformers GmbH. Welcome

Hands-On Transformer Testing and Maintenance

FUNCTIONS OF CIRCUIT BREAKERS

IB2-1 HIGH AVERAGE POWER TESTS OF A CROSSED-FIELD CLOSING SWITCH>:< Robin J. Harvey and Robert W. Holly

Magnetics and Power System Upgrades for the Pegasus-U Experiment

SPECIFICATIONS FOR A 4.7 TESLA/310MM BORE ACTIVELY SHIELDED MAGNET SYSTEM

DEVELOPING TESTING PROCEDURES FOR HIGH VOLTAGE INNOVATION TECHNOLOGIES

Feasibility of Electric Power Transmission by DC Superconducting Cables

ETAP PowerStation. Electrical Transient Analyzer Program. ETAP PowerStation. Short Circuit Analysis. ANSI Standard 3-Phase Fault Currents

Shunt Reactor Switching

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Tab 8 Surge Arresters

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

Modeling and Analysis of Superconducting Fault Current Limiters Applied in VSC-HVDC Systems

SPECIFICATIONS FOR AN MRBR 7.0 TESLA / 210MM ACTIVELY SHIELDED MAGNET SYSTEM

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

Transformer Protection

Review on Superconducting Fault Current Limiter

Tab 2 Voltage Stresses Switching Transients

CHAPTER 3 SHORT CIRCUIT WITHSTAND CAPABILITY OF POWER TRANSFORMERS

RF power tests of LEP2 main couplers on a single cell superconducting cavity

HVDC High Voltage Direct Current

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE

Enhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG)

Effects of Harmonic Distortion I

MEDIUM & HIGH VOLTAGE

USING DAMPED AC VOLTAGES

Transcription:

superior performance. powerful technology. Sub-cooled SFCL Device and Modules for Power Transmission / Distribution Juan-Carlos H. Llambes, Ph.D. SFCL Program Manager / Senior High Voltage Engineer University of Houston: V. Selvamanickam, I. Kesgin, G. Majkic. CAPS, Florida State University: J. Langston, M. Steurer, F. Bogdan, J. Hauer, D. Crook, S. Ranner, T. Williams, M. Coleman. SuperPower: D. Hazelton, J. Duval, M. Albertini, S. Repnoy. Applied Superconductivity Conference August 1-6, 2010 Washington, DC SuperPower, Inc. is a subsidiary of Royal Philips Electronics N.V.

Program Outline & Objectives Accomplishments & Results Planned Performance & Milestones Summary 2

Previous 2009 program focused on module development The current project purpose is focused on the development of secondgeneration (2G) high-temperature superconductor (HTS) based modules for a superconducting fault current limiter (SFCL) for operation at voltage levels up to transmission level. These modules can then be used in later proof-of-concept and alpha/beta prototypes. Primary objectives for FY09: continue to improve our understanding of the impact of recovery under load (RUL) on the module design continue to optimize the performance of the 2G HTS wire investigate the performance of more compact alternate module concepts test FCL module components at rated voltage in a cryogenic environment 3

2010 Program focused on sub-cooled / pressurized SFCL device and module development The current project purpose is focused on the Sub-cooled / Pressurized development of 2G HTS-based modules for a SFCL for operation at voltage levels up to transmission level. Primary objectives for 2010: continue improving our understanding Fault Current Limitation with and without recovery under load (RUL) on the module design in LN2 sub-cooled / pressurized conditions continue optimizing the performance of the 2G HTS wire investigate performance of more compact alternate module concepts test FCL module components at rated voltage in a cryogenic environment study 2G HTS Superconductor Voltage and Resistance limitation in open bath versus sub-cooled conditions. study and understanding of frequency dependence on SFCL device and modules 4

Modular SFCL system design components integration Modular SFCL device design specifications 2G tape Jc, J/cm/tape, RUL Arms/tape, mechanical, thermal and electrical properties Shunt Coils Zsh = Rsh + jxsh, X/R ratio, EM force withstand, thermal and electrical properties, connectors, size, weight, over-banding, ease of assembly and manufacturablity Sub-cooled Pressurized SFCL Device HTS assembly Tape per element, RUL per element, element energy capability, connectors, size, cooling orientation, failure mechanisms and mitigation, losses and their effects on cryogenics design HV design LN2 and GN2 design stress criteria, spacing between tapes, elements and modules, stress shield dimensions, using solid barriers or not, bushings and assembly integration, assembly supporting structure (post insulators), overall assembly to cryostat spacing and integration Cryogenics - LN2 flow control, LN2 and GN2 interface, pressurizing, safety issues, thermal handling of fault and steady state losses Sub-cooled Pressurized Improves the Recovery Under Load performance and enhances current carry capabilties. Improvement of LN2 dielectric performance Pressurized LN2 helps to increase dielectric properties, avoiding bubbles and lowering breakdown voltage probability. 5

Proof-of-concept demonstrated up to today Fault Current Testing with MCP 2212 (2004) Fault Current Testing with 2G YBCO (2006) Completed design and testing of HV bushings (ORNL, SEI, 2006) Weibull 2G failure study of standard HTS superconductor architectures (2006) Investigated several engineered 2G architectures for improved RUL (2008) Improve connector design (2008) Modify 2G conductor to improve performance for FCL application (2008) Designed / tested compact 55kA shunt coils to withstand high fault transient loads (2008) Thermal simulation of RUL process (2008) Demonstrated Recovery Under Load (RUL) proof of concept and requirements (2008) Investigated LN2 dielectric properties (with ORNL, 2005-2008) Beta device testing specifications established (2008) Study of the Impact of bubbles on breakdown mechanism and LN 2 dielectric strength (with ORNL 2008) Improved understanding of the impacts of recovery under load (RUL) for module design (2009) Optimized performance of the 2G HTS wire (2009) Investigated the performance of more compact alternate module concepts (2009) Tested FCL module components at rated voltage in a cryogenic environment (2009) Sub-cooled pressurized LN 2 environment testing (2010) Sub-cooled configuration of engineered 2G conductor (2010) Sub-cooled LN 2 dielectric performance improvement (2010) 6

Program Outline & Objectives Accomplishments & Results Planned Performance & Milestones Summary 7

SFCL module manufacturing and assembly 2 nd Assembly of Supports 1 st SFCL Module Manufacturing 4 th Module Installation 5 th Internal Installation 3 rd Assembly of Connections 8

High voltage bushing and sensors installation 8 th Assembly of HV Bushings 6 th Assembly of Connectors 7 th Assembly of Sensor Probes 9

Pressure vacuum lines, digital pressure sensors, thermocouples, LN 2 ports, level, vent and relief valves LN2 Main Filling Port Digital Pressure Gage Thermocouples Top Flange Assembly QF40 Port Vacuum Line 1 High Voltage Bushings Vacuum Line 2 10

Pressure vacuum lines, digital pressure sensors, thermocouples, LN 2 ports, level, vent and relief valves. Main Vacuum Valve Pressure Burst Disk Pressure Relief Valve Pressurized Vacuum Lines Pressure Line Valve Pressure Gage Main Vacuum Line 1 11

Shipping the SFCL to the Center for Advanced Power Systems (CAPS) at FSU in Tallahassee, FL SuperPower SFCL Loading Assembly at CAPS, FSU Shipping to CAPS, FSU 12

FSU-CAPS testing power in 2010 Real Time Simulator RTDS 4.16 kv utility bus 5 MW Converter Amplifier AC Voltage feedback to RTDS AC current reference from RTDS 0 4.16 kv / 5 MVA experimental bus SFCL Device 5 MVA power available in 2010 SFCL Device under test 13

Limited current with a single 2 tape circuit in a module Prospective, Limited, Shunt and Tape Current 25 20 15 65% Reduction at 1 st peak 75% Reduction at 5 th peak 10 Current (ka) 5 0-5 I Shunt I Limited I Superconductor I Prospective -10-15 -20-25 0 0.016 0.032 0.048 0.064 0.08 Time (s) 65% Fault reduction at 1 st peak with 2 tape circuit for a prospective of 26kA 14

1 st peak limited current for a 2 tape circuit vs. voltage Current (ka) ~ 65% Fault Reduction A single circuit of 2 tapes in a SFCL module will limit 65% of 1 st peak fault in the entire voltage range (up to 25kA prospective tested at CAPS) 15

1 st peak current for 2 tapes vs. voltage and frequency 65% Reduction Current (ka) 48% Reduction 45% Reduction Current at different frequencies play a critical role in tape performance due to eddy current, skin depth on tape and non-homogeneous inductance at quenching. 16

1 st peak current for 2 tapes vs. voltage and frequency Current (ka) 40% Reduction 31% Reduction 20% Red. Different tape architecture also plays an important role in the overall system percentage fault limitation at different frequencies. 17

Peak load current per tape and voltage for 74K and 77K Q U E N C H 77 K Sub-cooled Sub-cooled Voltage Range Voltage at 77K (100%) Open Bath Voltage Limit Voltage Increase at 74K (92%) Sub-Cooled Voltage Limit 32% Increase Current At 77K (100%) Sub-cooled conditions at 74K improved 92% voltage (192% increase) and 32% more current (132%), a total of ~253% increase in power. 18

Program Outline & Objectives Accomplishments & Results Planned Performance & Milestones Summary 19

Generalized modular SFCL specification development in 2009 vs. 2010 up today 2009 Milestones of the modular baseline design for transmission and distribution lines Module current scalable in multiples of 500 A peak Module voltage scalable from 400 V - 1 kv peak Prospective fault currents scalable from 5-10 ka peak 2010 testing for modular baseline design for transmission and distribution lines Module load current capable of carrying 4kA peak tested with sub-cooled LN 2 at 74K Module voltage tested with capability of driving 4kV peak at 77K, and >7KV subcooled at 74K. Prospective modular fault current testing of 25 ka peak at CAPS, previously tested up to 40kA peak at 77K at KEMA. New sub-cooled SFCL modules are able to handle faults of 65kA peak when subcooled at 74K. 20

Generalized SFCL specification development The modular design permits scale-up of validated voltages and currents to accomplish Distribution and Transmission levels The number of modules used are based on the voltage / current requirements of the application A Distribution SCFL 11-15kV phase, 800-2KA rms load current will limit ~65-75% when assembled with 3 SFCL modules 1.25m 2.5m Distribution SCFL 15kV phase illustration A Transmission SCFL 138kV phase, 1700A rms load, 40kA prospective will limit ~65-75% if assembled with 14 SFCL modules 1.25m 2.5m Transmission SCFL 138kV phase illustration 21

Program Outline & Objectives Accomplishments & Results Planned Performance & Milestones Summary 22

Summary Focus on SFCL module development for distribution/transmission devices. Significant progress in: Sub-cooled performance Sub-cooled modular elements were developed and tested in 2010 Sub-cooled modular elements increase 132% current at 74K Sub-cooled modular elements increase 192% voltage at 74K Total Sub-cooled modular elements increase of 253% in power at 74K Further testing study down to 65K range will be evaluated for the modular elements LN 2 d ielectrics Further dielectric strength testing has been evaluated for the modular elements Sub-cooled high voltage testing Further sub-cooled High Voltage testing will be evaluated for the modular elements 23

Summary Frequency and Harmonics study First study of frequency impact on 2G has been evaluated for 60Hz, 120Hz, and 240Hz. Larger range of harmonic and current frequencies testing and study is underway. Overall system design reduction In our SFCL design, any improvement in 2G architecture performance directly translates into a proportional reduction on the overall cryogenics and system cost. Although there should be additional improvement in voltage at 65K that we are not accounting at this time, previous testing has shown an improvement in current around 200% at 65K from the present improvement of 253% at 74K. The expected 200% improvement of just in the modular current at 65K together with the 253% power improvement achieved this year at 74K will yield a combined improvement in power of at least 506%. 24

Summary Present improvements in modules will permit to build: A single Distribution SCFL phase of 11-15kV, 800-2KArms load, with ~65-70% limitation if assembled with 3 SFCL modules A Transmission SCFL phase of 138kV, 1700Arms load, 40kA prospective limited between ~65-70% if assembled with 14 SFCL modules Great interest received from different customers to integrate our SFCL technology to develop SFCL devices and other kinds of superconducting devices built with SFCL capabilities 25

Questions? Please contact: jllambes@superpower-inc.com www.superpower-inc.com 26