ad notam MOUNTING SYSTEM FOR ON-WALL APPLICATION

Similar documents
Stuff-Your-Stuff Platform Bed (Twin and Full)

#4 Phillips Driver Bit 1/8, 4mm, 5.5mm & 8mm (5/16 ) Allen Wrench. Safety Glasses

Assembly Instructions Music Library System

Heritage Solar Lamp Post

Colonial Classic Bar

Barnside Pantry IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratch

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS

Part # Ford Mustang Stalker Front Bumper

Franklin Mills Stackable Movable Lateral Instructions

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

Interactive Monitor Arm

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

Part/Reorder Number: Version 1.0

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Kitchen Island IMPORTANT Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches o

Media Storage Systems Fixed Media Cabinets

Dual Arm Tilt LCD Mount

ASSEMBLY AND ADJUSTMENT

LOGAN HUTCH WITH SHELVES 36

C. Side Panel 1 pc. B. Side Panel. 1 pc. J2. Shelf. 4 pcs. Adjustable Pin 24 pcs. (+1 extra) M3.5x16 Wood Screw 20 pcs. (+1 extra) 2 pcs.

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER


Installation Instruction

LOIRE 3 DOOR MIRRORED WARDROBE ASSEMBLY INSTRUCTIONS

Please read and understand the OnBoard Timpani Cart Owner s Manual before using the Timpani Cart.

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Connect Transit Shelter

Whalen Furniture Mfg. Factory No. 5 Page # 1

IMPORTANT Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches or other damag

IMPORTANT: WILL NOT FIT COUNTRYMAN MODELS

Side and rear window, assembly overview

ADULT ASSEMBLY REQUIRED DUE TO THE PRESENCE OF SMALL PARTS, SHARP POINTS, SHARP EDGES

Panoramic Door. Block Frame Installation Manual Aluminum top and bottom track with either aluminum or vinyl panels

EDGE2 DUAL MONITOR ARM

Assembly Instructions Nevins Phone Booth

SERIES: CONFIGURATION: MOUNTING PACKAGE: 1200 Door-Door Frameless, sliding door

Assembly, Operating, Safety and Parts Manual

XL-GC03 Sliding Door Lock Installation Manual PAT XL-GC06 Sliding Door Hanger Installation Manual XL-GC08 Sliding Door Lock Guide Installation Manual

M. Door 1 Pc. 1 Pc. Door 1 Pc. 1 Pc. M3x20 Wood Screw (long) 8 Pcs. (+1 extra) M3x10 Wood Screw for Magnet 8 Pcs. (+1 extra)

Pantry IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratches or oth

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

ADULT ASSEMBLY REQUIRED

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

C PART LIST HARDWARE LIST. Kitchen Cart IMPORTANT NOTE

INSTRUCTION BOOKLET AND WARRANTY INFORMATION 6 BENCH GRINDER

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER 4400A-4500A

3/8 FRAMELESS BYPASS SLIDING SHOWER ENCLOSURE

T R I - S TA N D C H A I N V I S E

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER

Installation Instructions

Small Above Fireplace Pull-Down Full-Motion TV Wall Mount

GETTING STARTED. Instructions IMPORTANT PS B PS B. Record the serial number from the tag on the door front.

INSTALLATION INSTRUCTIONS

Dalton Park 5pc Dining Set

340 & 350 SERIES BATH ENCLOSURES

RM4000 Tektronix 4000 Series Rackmount Kit

PART NUMBER: T-R20 PACKAGE CONTENTS: GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS Scuff Plate TOOLS REQUIRED: APPLICABLE MODELS: 2013 MAZDA CX-

Display-Top Apothecary Cabinet. Assembly Instructions. Page 1

LOCKN LOAD FIRST TIME INSTALLATION

#709 Magnum Shear Stand

MITSUBISHI PAJERO CK LONG WHEEL BASE 2100 MM TRACKS TRMP001

Installation Instructions

Pedestal Desk. D. Side Panel 1 pc. E. Side Panel. I. Back Panel. 2 pcs.

LYMAN S ORANGE CRUSHER/ CRUSHER II PRESS

DOREL ASIA DESK, HUTCH & CHAIR. Lot number: Date of purchase: / /

EllisSaw.com. EllisSaw.com P.O. Box Verona, WI

Assembly Instructions Nevins Phone Booth

TYPHOON ASSEMBLY AND INSTALLATION INSTRUCTIONS

Elcometer Muller Laboratory Grinder

CTA-100 VCR / DVD / Cable Box Adapter

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

ASSEMBLY INSTRUCTIONS MANUAL

LAND ROVER DEFENDER UNDER CONSOLE SAFE

MAKO EC EXTENDED CABINET

SAN12 ( <00>)

ENCORE / BRAVO SHOWER AND TUB DOOR INSTALLATION NSTRUCTIONS

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

Modern Gatherings 60" TV Console Assembly Instructions

Bath Accessory Installation

SAFETY. Read and understand all safety precautions and instructions before installing this product.

Loading Dock Safety Gate

SPACESAVER ITEM # , MODEL #9819WWMV, 9820CHMV Français p. 13 Español p. 25. ATTACH YOUR RECEIPT HERE Serial Number.

DRAWER Volkswagen amarok

Installation Guide Mounting Kit Philips MP70/EGM/FMS on Dräger Fabius Tiro

Unit No. 6150, 7150 Deluxe Framed Sliding Tub/Shower Enclosure

DRAWer FORD RANGER IMPORTANT WARNING! SSDS201 / SSFR001. INSTALL TIME: 1 Hour. Thank you for purchasing a Front Runner Storage System.

IMPORTANT WARNINGS AND CAUTIONS!

VARIABLE SPEED WOOD LATHE

ASSEMBLY INSTRUCTIONS FOR STORETTE STA42

A401 Instruction Manual

PART #MSP-DCCST Flat Panel Tilt Mount

Monster Tower Phone: U.S. Hwy 411 S. HS1. Installation Instructions and Owner s Manual CAUTION

1040 & 1050 SERIES HEAVY FRAMELESS BYPASS BATH ENCLOSURE

MIRAGE-X / BELLA. Shower Door Installation Instructions

REVIVAL ACCESSORIES BEFORE YOU BEGIN A. HOW TO USE THESE INSTRUCTIONS B. PRODUCT NOTES C. ORDERING INFORMATION D. REQUIRED TOOLS AND MATERIALS

For assembly see instructions in carton

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

MSP-DCCPGSU Large Screen Static Display Mount

#4500 BULLET SIZER & LUBRICATOR

Transcription:

ad notam MOUNTING SYSTEM FOR ON-WALL APPLICATION Art.No. OWMS_880 applicable for installations up to 59.2kg VERY IMPORTANT NOTE NEVER USE MORE THAN ONE SET ON ONE GLASS! INSTALLATION GUIDE

FOR YOUR SAFETY Please read all safety information thoroughly before using the product. Not complying with the instructions provided within this installation guide may result in severe injuries or life-threatening situations and/or damage respectively change the product. Please comply accurately with all warning instructions to ensure proper operation of the product. Copyright 2013 by ad notam. All Rights Reserved. All brand names, product names and/or trademarks are the property of their respective owners. This manual, as a whole, in part or excerpts, may not be reproduced, copied, stored in a data retrieval system or transferred electronically, mechanically or in any other way, shape or form without prior written authorization by ad notam. Specifications of the ad notam products are subject to unannounced changes; this manual may thus not reflect the current technical status.

CONTENTS PACKAGE INCLUDES...4 DESCRIPTION...5 SAFETY INSTRUCTIONS...6 PREPARATION...7 MOUNTING...9 3

PACKAGE INCLUDES Thank you for choosing an ad notam product. Before using the mounting system please check the following contents of the package for completeness: OWMS_880 Description Illustration Amount Wall mounting plate (WMP) dimensions: 880 x 72 x 55mm 1 Glass mounting plate (GMP) dimensions: 880 x 104 x 55mm backside: self adhesive (may be pre-installed on glass) Wall locking plate (WLP) dimensions: 60 x 60 x 49mm 1 1 Glass locking plate (GLP) dimensions: 60 x 60 x 27mm backside: self adhesive (may be pre-installed on glass) Fixation magnet diameter: 45mm, depths: 13.7mm Distance ring diameter: 45mm, depths: 39mm Magnet holder plate counterpart for the magnets dimensions: 70 x 70 x 1mm (may be pre-installed on glass) 1 2 2 2 Flat head locking bolt (M6) for GLP Countersunk bolt, 100mm Round head screw for WMP Round head screw for WLP Screw anchor Lock washer for WMP, WLP, GLP 1 2 5 4 11 10 4

DESCRIPTION The ad notam on-wall mounting system is designed to install a glass or mirror surface protruding from the wall. It is qualified even for installations in damp locations and features a mechanical suspension mechanism at the upper edge as well as magnetic fixation elements and a locking bolt at the lower edge. The on-wall mounting system may be combined with a visual cover or LED lighting elements. 5

SAFETY INSTRUCTIONS SAFETY INSTRUCTION REGARDING GLASS SURFACE PREPARATION The glass surface must be clean and dry. Contaminated surfaces should be cleaned with ad notam s preferred solvent. A clean lint-free cloth should be used. Use proper safety precautions for handling solvent. SAFETY INSTRUCTION REGARDING TAPE PRIMER Shake tape primer well before using. Apply a thin uniform coating to the glass surface using the minimum amount that will fully coat the surface. Allow tape primer to dry thoroughly before applying tape. This is usually accomplished in 5 minutes at room temperature. Be sure the primed surface remains free from containments prior to applying the tape. Tape primer can be removed with ad notam s preferred solvent. Vigorous scrubbing may be required. Carefully read and follow manufacturer s precautions and directions for use when handling cleaning solvents. SAFETY INSTRUCTION REGARDING SELF-ADHESIVE TAPE Shelf life: 6 months from day of dispatch by ad notam when stored in the original carton at 21 C [70 F] and 50% relative humidity. SAFETY INSTRUCTION REGARDING APPLYING OWMS TO GLASS Pressure: Bond strength is dependent upon the amount of adhesive-to-surface contact developed. Firm application pressure develops better adhesive contact and helps improve bond strength. Typically, good surface contact can be attained by applying enough pressure to insure that the tape experiences approximately 15 psi (100 kpa) pressure. Either roller or platen pressure can be used. Note that rigid surfaces may require 2 or 3 times that much pressure to make the tape experience 15 psi. Temperature: Ideal application temperature range is 21-38 C [70-100 F]. Initial tape application to surface at temperatures below 10 C [50 F] is not recommended because the adhesive becomes too firm to adhere readily. However once properly applied low temperature holding is generally satisfactory. Wet out time: After application, the bond strength will increase as the adhesive flows onto the surface. At room temperature approximately 50% of ultimate bond strength will be achieved after 20 minutes, 90% after 24 hours and 100% after 72 hours. This flow is faster at higher temperatures and slower at lower temperatures. Ultimate bond strength can be achieved more quickly (and in some cases bond strength can be increased) by exposure of the bond to elevated temperatures (e.g. 66 C [150 F] for 1 hour). This can provide better adhesive wet out onto the substrates. 6

PREPARATION REQUIRED TOOLS o Phillips-tip screwdriver o Allen wrench o Level and measuring tape o Glass cleaner and clean cloths o Glass suction cups GLASS PREPARATION - STANDARD RULE OF ASSEMBLY The mounting system elements that need to be affixed on the backside of the glass surface are basically arranged at factory according to a standard rule of assembly: 90mm 3.54 centered 125mm 4.92 90mm 3.54 125mm 4.92 90mm 3.54 90mm 3.54 If you have indicated on the ad notam glass orderform that you wish to receive the glass without factory-affixed mounting system elements, they should have been enclosed to your delivery unmounted. In this case please clean the rear side of the glass surface thoroughly with glass cleaner and/or compressed air before beginning assembly. Also make sure that you know where top and bottom is. NOTE After affixing the self-adhesive mounting elements according to your specification allow 24 hours drying to ensure perfect adhesion. WARNING ad notam declines any liability for installations without factory-affixed mounting system elements. 7

138mm / 5.43 125mm / 4.92 125mm / 4.92 PREPARATION CAUTION Before getting started please notice that ad notam declines any liability for the screws and screw anchors delivered with the product. These may need to be replaced at the job site when considering the nature of the load-bearing wall, since ad notam is not familiar with the construction environment. NOTE Use the 100mm countersunk bolts and a distance ring for each fixation magnet. WALL PREPARATION Structural measures must be accomplished for an on-wall installation. A specialist should carry these out. The following indicated dimensions are only relevant for glasses prepared according to the standard rule of assembly, see section glass preparation! Mark the drill holes for the center screw of the wall mounting plate (WMP) and the fixation magnets considering the desired position of the glass surface on the wall. The drill hole for the center screw of the WMP should be marked 138mm / 5.43 below the center of the upper edge of the desired position of the glass surface. The drill holes for the fixation magnets are supposed to be marked 125mm / 4.92 from the lower edge and the sides of the desired position of the glass surface. Then drill the three holes at the marks, mount the anchors and screw the WMP incl. lock washer as well as the fixation magnets incl. distance rings securely to the wall. upper edge glass surface 125mm / 4.92 125mm / 4.92 OWMS_880 Countersunk bolt 100mm 1 x distance ring 39mm lower edge glass surface 8

PREPARATION Now mark the drill holes for the outer screws of the wall mounting plate on the wall using a level. Then drill the holes at the marks, mount the anchors and fix the WMP in place by tightening the five round head screws. uppe r edg e gla ss su rface 5 x round head screw 5 x lock washer 5 x anchor lowe r edg e gla ss su rface When all mounting elements are arranged in good order we recommend to add also the wall locking plate (WLP) in order to secure the glass on the wall. For this purpose locate the center of the WLP 130mm / 5.12 above the center of the lower edge of the desired position of the glass surface and mark the four outer drill holes on the wall. Then drill the holes at the marks, mount the anchors and fix the WLP uppe r edg incl. lock washers in place bye gtightening the round head screws. lass surfa ce lowe 130m r edg m/5 e gla ss su rface.12 4 x round head screw 4 x lock washer 4 x anchor 9

MOUNTING When the wall and the glass are prepared, use the suction cups to elevate the glass in order to let the self-adhesive glass mounting plate (assembled on the upper backside of the glass) slide-in the wall mounting plate (affixed in the upper position on the wall). When the slide-in mechanism is locked in place let the self-adhesive magnet holder plates (assembled on the lower backside of the glass) snap the fixation magnets (affixed in the lower position on the wall). NOTE The edges of the glass are very sensitive. Take care that they do not touch the wall in any way to avoid damages and split-offs. Finally screw the locking bolt with a lock washer bottom-up through the glass locking plate and the wall locking plate in order to secure the glass on the wall. 10

ad notam Web: www.ad-notam.com E-Mail: info@ad-notam.com For your local distributor please visit: www.ad-notam.com/contact ad notam OWMS_880 Installation Guide * 24. October 2013 * Version 1.5 MOUNTING SYSTEM FOR ON-WALL APPLICATION