Parallel optical coherence tomography system

Similar documents
Optical coherence tomography

some aspects of Optical Coherence Tomography

Assembly and Experimental Characterization of Fiber Collimators for Low Loss Coupling

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

Simultaneous acquisition of the real and imaginary components in Fourier domain optical coherence tomography using harmonic detection

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

Supplementary Figure S1. Schematic representation of different functionalities that could be

Absorption: in an OF, the loss of Optical power, resulting from conversion of that power into heat.

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

Optical design of a dynamic focus catheter for high-resolution endoscopic optical coherence tomography

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Numerical simulation of a gradient-index fibre probe and its properties of light propagation

GRINTECH GmbH. product information.

Integrated photonic circuit in silicon on insulator for Fourier domain optical coherence tomography

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

(51) Int Cl.: G01B 9/02 ( ) G01B 11/24 ( ) G01N 21/47 ( )

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

InP-based Waveguide Photodetector with Integrated Photon Multiplication

CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

PROJECT REPORT COUPLING OF LIGHT THROUGH FIBER PHY 564 SUBMITTED BY: GAGANDEEP KAUR ( )

Laser Speckle Reducer LSR-3000 Series

High-power All-Fiber components: The missing link for high power fiber lasers

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Laser Beam Analysis Using Image Processing

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Parallel Mode Confocal System for Wafer Bump Inspection

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Instruction manual and data sheet ipca h

Isolator-Free 840-nm Broadband SLEDs for High-Resolution OCT

A novel tunable diode laser using volume holographic gratings

Index. Cambridge University Press Silicon Photonics Design Lukas Chrostowski and Michael Hochberg. Index.

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

Light Guide Overview

A miniature all-optical photoacoustic imaging probe

Optics and Lasers. Matt Young. Including Fibers and Optical Waveguides

Spatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source

Realization of Polarization-Insensitive Optical Polymer Waveguide Devices

Using Stock Optics. ECE 5616 Curtis

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

Investigation of an optical sensor for small angle detection

Design Rules for Silicon Photonics Prototyping

Thin holographic camera with integrated reference distribution

Dynamic Phase-Shifting Microscopy Tracks Living Cells

The absorption of the light may be intrinsic or extrinsic

A Laser-Based Thin-Film Growth Monitor

USE OF COMPUTER- GENERATED HOLOGRAMS IN OPTICAL TESTING

Three-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy

Comparison of FMCW-LiDAR system with optical- and electricaldomain swept light sources toward self-driving mobility application

On-chip interrogation of a silicon-on-insulator microring resonator based ethanol vapor sensor with an arrayed waveguide grating (AWG) spectrometer

Collimation Tester Instructions

Characterization of optical fiber imaging bundles for swept-source optical coherence tomography

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

OPTICAL BACKSCATTER REFLECTOMETER TM (Model OBR 5T-50)

Design, Fabrication and Characterization of Very Small Aperture Lasers

Reflecting optical system to increase signal intensity. in confocal microscopy

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Imaging the Subcellular Structure of Human Coronary Atherosclerosis Using 1-µm Resolution

Basic concepts. Optical Sources (b) Optical Sources (a) Requirements for light sources (b) Requirements for light sources (a)

OPTICAL coherence tomography (OCT) is a noninvasive

Moving from biomedical to industrial applications: OCT Enables Hi-Res ND Depth Analysis

E LECTROOPTICAL(EO)modulatorsarekeydevicesinoptical

Vanishing Core Fiber Spot Size Converter Interconnect (Polarizing or Polarization Maintaining)

First Observation of Stimulated Coherent Transition Radiation

InP-based Waveguide Photodetector with Integrated Photon Multiplication

Investigation of the Near-field Distribution at Novel Nanometric Aperture Laser

Optics Communications

High-Coherence Wavelength Swept Light Source

Talbot bands in the theory and practice of optical coherence tomography

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

Vixar High Power Array Technology

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

Use of Computer Generated Holograms for Testing Aspheric Optics

RECENTLY, using near-field scanning optical

3 General Principles of Operation of the S7500 Laser

DESIGN NOTE: DIFFRACTION EFFECTS

FCQ1064-APC 1064 nm 1x4 Narrowband Coupler. Mounted on

IST IP NOBEL "Next generation Optical network for Broadband European Leadership"

Two-step K Na and Ag Na ion-exchanged glass waveguides for C-band applications

Optical properties of small-bore hollow glass waveguides

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

Radial Coupling Method for Orthogonal Concentration within Planar Micro-Optic Solar Collectors

Ring cavity tunable fiber laser with external transversely chirped Bragg grating

System demonstrator for board-to-board level substrate-guided wave optoelectronic interconnections

3550 Aberdeen Ave SE, Kirtland AFB, NM 87117, USA ABSTRACT 1. INTRODUCTION

High-efficiency, high-speed VCSELs with deep oxidation layers

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Numerical analysis of gradient index lens based optical coherence tomography imaging probes

CHAPTER 7. Waveguide writing in optimal conditions. 7.1 Introduction

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

In-line digital holographic interferometry

60 MHz A-line rate ultra-high speed Fourier-domain optical coherence tomography

Lecture 22 Optical MEMS (4)

Supplementary Materials

Transcription:

Parallel optical coherence tomography system Yuan Luo, 1,3, * Lina J. Arauz, 1 Jose E. Castillo, 1 Jennifer K. Barton, 1,2,3 and Raymond K. Kostuk 1,3 1 Department of Electrical and Computer Engineering, University of Arizona, 1230 E. Speedway Boulevard, Tucson, Arizona 85721, USA 2 Division of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, USA 3 College of Optical Sciences, University of Arizona, Tucson, Arizona 85721, USA *Corresponding author: luo@email.arizona.edu Received 21 May 2007; revised 14 October 2007; accepted 15 October 2007; posted 16 October 2007 (Doc. ID 83204); published 28 November 2007 We present the design and procedures for implementing a parallel optical coherence tomography (POCT) imaging system that can be adapted to an endoscopic format. The POCT system consists of a single mode fiber (SMF) array with multiple reduced diameter 15 m SMFs in the sample arm with 15 m center spacing between fibers. The size of the array determines the size of the transverse imaging field. Electronic scanning eliminates the need for mechanically scanning in the lateral direction. Experimental image data obtained with this system show the capability for parallel axial scan acquisition with lateral resolution comparable to mechanically scanned optical coherence tomography systems. 2007 Optical Society of America OCIS codes: 170.4500, 170.2150, 060.2280, 060.2350. 1. Introduction Optical coherence tomography (OCT) is a coherent imaging technique that can acquire twodimensional subsurface images of tissue structure in highly scattering environments. OCT can produce high-resolution 10 m cross-sectional images of a biological tissue sample with an imaging depth of 1 2 mm in highly scattering media [1 4]. Due to these properties, OCT techniques show great promise for medical imaging applications. Many of the existing OCT systems use fiber-optic interferometers. These systems currently collect object information through one single mode fiber (SMF). Mechanical scanning in the lateral direction increases the time to acquire an image. Steps have been made toward developing a parallel OCT system that reduces the acquisition time by having all A scans acquired at the same time, rather than sequential times. For many applications, sequential scanning is appropriate, but for high-speed operations, for instance, laser ablation, the most rapid mechanically scanning systems may be inadequate. Full field OCT systems can rapidly acquire images, 0003-6935/07/348291-07$15.00/0 2007 Optical Society of America but they are not appropriate for endoscopic use [5]. Conventional fiber image guides with multimode fibers that support a few modes have been used in special purpose OCT systems [6]. However, good image quality depends upon separating the fundamental mode from higher modes. As the fiber guide is bent, the power in the modes will change. Therefore, their use is limited to rigid endoscopic applications. Recently, we demonstrated a SMF array with 15 m diameter fibers for use as a proximity sensor [7]. This array provides high throughput and minimal cross talk between fibers. In this paper, we describe the fiber packaging techniques for implementing a parallel OCT (POCT) system, and we evaluate its performance. This system was used to obtain images of both scattering and high reflectivity semiconductor samples. 2. Fiber Array and Probe Assembly A. Single Mode Fiber Array The fiber array used in the sample arm of the POCT system consisted of SMF-28 [8] fibers that had been etched to 15 m diameters using a standard buffed oxide etch (BOE) solution with a process described in previous papers [9,10]. The etched section is 8291 APPLIED OPTICS Vol. 46, No. 34 1 December 2007

Fig. 1. (Color online) (a) Schematic of a linear fiber array with 15 channels and a silicon trench groove. (b) Linear fiber array with eight channels for POCT. Table 1. Channel Transmission Efficiency Channel (%) 1 92 2 96 3 91 4 93 5 93 6 98 7 91 8 97 1 mm long, and the uniformity of the length and diameter is very good due to the stable nature of the BOE process [10,11]. The reduced diameter fibers were mounted in a silicon trench groove with a depth of 13.5 m, as shown in Fig. 1(a). The etched fiber tips have a 2 mm long linear tapered section providing a transition region between the etched and standard fiber diameter sections. Pressure was applied to the reduced diameter fiber ends to keep them aligned adjacent to each other. The fibers were cemented in place with an UV curable epoxy (Angstrom Bond OG134) with a refractive index of 1.435 that is lower than the core index of the fibers (1.4517) to help confine the field mode. The cured sample was then cut with a dicing saw (780, Kulicke & Soffa) and polished to provide a good optical surface. An eight-fiber array is shown in Fig. 1(b). The fiber array used in the demonstration POCT system has eight 15 m diameter fibers. Arrays with 15 fibers have also been fabricated. Neglecting Fresnel reflections, the measured transmission efficiency 100% P out P in of each fiber is greater than 90%. Transmission data for the eight-channel array are shown in Table 1. This result indicates that high optical quality of the reduced fiber section and the fiber end surface can be achieved with the fiber etching and end face preparation technique. The cross talk from a signal fiber to the adjacent fibers is defined using the relation of P xt db 10 log P adjacent P signal, where P adjacent and P signal is the output of the fiber immediately adjacent to the signal fiber, and the signal fiber, respectively. The measured cross talk between the signal and adjacent channels is less than 30 db. B. Assembled Probe Tip A GRIN rod lens provides a compact imaging element that is useful in fiber endoscope systems [6]. A 1:1 imaging configuration was chosen to reduce aberrations and provide good signal collection efficiency with minimal overlap of adjacent beam profiles. A commercially available GRIN rod (Quantum Focus, Corning) with a 1.8 mm outside diameter was cut to a fractional pitch (FP) of 0.48 at a wavelength of 1.31 m. The lens images the fiber core to a distance of 250 m beyond the last surface of the endoscope in air. A BK7 glass cover with a thickness of 0.2 mm was used to protect and isolate the GRIN lens from the object environment. It was cemented to the GRIN lens with a UV curable epoxy (Norland NOA74) to minimize backreflections. The epoxy had a coating thickness of 20 m and a refractive index of 1.54 at a wavelength 1.31 m. The optical design for the assembled probe tip is shown in Fig. 2. In addition, a 0.2 mm thick rigid stainless steel tube with a 2 mm 1 December 2007 Vol. 46, No. 34 APPLIED OPTICS 8292

Diagram of the assembled probe end of the POCT sys- Fig. 2. tem. outer diameter and a 1.8 mm inner diameter was used to house the assembled probe tip, and the configuration is shown in Fig. 3. The image conjugates of the probe tip must be slightly greater than 1:1 because one end of the GRIN lens is glued to a BK7 glass cover. ZEMAX optical modeling software (Zemax Development Corporation, Washington) was used to characterize beam propagation through the tip optics. Gaussian beam trace options were used to characterize the beam waist in the image plane. It was assumed that the tissue had a refraction index of 1.35 at a wavelength of 1.31 m, and the beam waist at the input of the GRIN lens was 9.0 m, which is the mode field diameter (MFD) of the SMF-28. According to the simulation by ZEMAX, the paraxial magnification was 1.01, with a Strehl ratio of 0.95. In addition, the system created an aberration-free 9.1 m diameter beam waist and imaged the fiber core to a distance of 257 m beyond the outer edge of the BK7 coverslip. Analysis of the focal position and beam diameter for the fibers at the center and edge position of the eight-element fiber array indicated that they were nearly equal. The measured beam waist was 8.2 m, and the resultant depth of focus was 240 m. 3. System Description and Imaging Characteristics A. Fiber-Length Equalization To obtain an interference pattern with the interferometer system, the path length difference between reference and sample arm must be less than the coherence length of the source. Since the time-domain POCT system described in this study consists of multiple fiber interferometers, each paired reference and sample fiber length was equalized to within the scanning range of the galvometer to provide overlap of the coherence region. For our system, the scanning range was 2 mm in air. Each fiber path length was equalized using the fiber interferometer shown in Fig. 4. Light from a superluminescent light emitting diode (SLD) with a center wavelength of 1.31 m and a spectral bandwidth of 40 nm was split between the reference and sample fibers by passing it through a 3 db coupler (SMC-11350229U, FIS, Inc.). An array of 3 db couplers was assembled into a junction box with standard FC-APC connectors so that each fiber could be quickly tested. Each fiber in the assembled endoscope was fusion spliced to a connectorized fiber end, forming an overall sample arm fiber length of 1 m. In the reference arm, the light was collimated and reflected from a galvometer-mounted retroreflector. Focused light reflected from a stationary infrared mirror in the sample arm recombined with the reference arm light on the surface of the infrared detector. A translation stage in the reference arm allowed for adjustment of the path length difference for distances Fig. 3. Diagram of the endoscopic assembled probe with a 0.2 mm thick rigid stainless steel tube: (a) lateral view and (b) front view. Fig. 4. Schematic of fiber-length equalization interferometer. Light from a SLD is split between the reference and sample fibers by passing it through a3dbcoupler. The probe end illuminates an IR mirror, and the reference end illuminates a glavo mirror. The return signal from the paired sample and reference arm is coupled into an output fiber that transfers the combined interference signal to an IR detector. 8293 APPLIED OPTICS Vol. 46, No. 34 1 December 2007

greater than the 2 mm modulation of the galvanometer-mounted reference mirror. The interference pattern of each paired sample and reference fiber was observed. To accomplish length equalization, a fiber in the reference arm with the shortest path length difference was picked as the reference position for the other fibers. A LABVIEW program controlled the measurement process of the path length difference. The amplitude of the interference pattern was recorded as a function of the position of the reference mirror and computed the difference in path lengths of the arms of the interferometer. The fibers in the reference arms were cleaved precisely so that the difference among the fringe positions was no more than the scanning range of galvometer. The remaining position difference was calibrated and compensated by the software. This equalization technique was first proposed in [10]. The path length difference achieved between all paired channels was less than 1.3 mm in air. B. Image Acquisition Figure 5 shows the schematic for the POCT system. The sample arm of the POCT consists of the assembled fiber array GRIN lens cover glass endoscope. The transverse sampling of the system is determined by the fiber-to-fiber spacing (15 m in this configuration). Since the assembled probe is in a 1:1 imaging system, the transverse resolution of the system is also 9.1 m. The axial resolution of the system was calculated to be 19 m, assuming a Gaussian spectral distribution and using the formula [3] z FWHM 2 ln 2 2 2 0.44, (1) The equalized reference arm fibers were placed in a commercially available silicon based 16-fiber V-groove substrate (VGC-16-250, OZ Optics, Ltd.) with center-to-center spacing of 250 m. The optical elements in the reference arm were designed to minimize sensitivity to the lateral fiber position and maximize the power coupled back into the fiber from the galvo mirror. In addition, the fiber lengths between the 1 10 splitter and 3 db coupler array had different lengths l to avoid coherent interference effects between channels. The variations l were made greater than the coherence length of the source to prevent interference. For practical considerations the variation in the fiber length between channels in our system was 1 cm (much larger than required). However, each reference and signal fiber length was matched within the scanning range of the galvonometer. The actual variation between fiber channels in our system was 1 cm and the difference between the shortest and longest channel was 8 cm. The detector array consisted of eight IR detectors. The interference signal of each paired sample and reference fiber was detected by its corresponding IR detector. After amplification and filtering, each detector signal was demodulated using a lock-in amplifier (SR810, Stanford Research Systems, Sunnyvale, California). Because of the limited availability of lock-in amplifiers, signal data was acquired from successive elements with one lock-in amplifier and then assembled to form an image. LABVIEW software was used for data acquisition and controlling the galvanometer. An image processing algorithm was used to reconstruct the image from the measured data. This proof-of-principle process can be used for stationary objects. In the subsequent images, the dynamic range where is the full width at half maximum (FWHM) measured in wavelength units, and is the center wavelength of the source. The measured axial resolution was 21 m. Fig. 5. Parallel OCT system setup. Light from a SLD is coupled into a parallel fiber array by a 3 db coupler box. The probe end illuminates a target sample, and the reference end illuminates a glavo mirror. The return signal from the paired sample and reference arm is coupled into an output fiber that transfers the combined interference signal to an IR detector. Fig. 6. POCT image of the central portion of a contact lens. The resultant depth is 300 m with 120 m 8 15 m wide. 1 December 2007 Vol. 46, No. 34 APPLIED OPTICS 8294

of the POCT signal has been compressed with a logarithmic operation and the depth was scaled by the average index of the sample of refraction. All images are 120 m (8 fibers 15 m fiber separation) in width. Images were acquired at a reference arm scan rate of 14 Hz. According to the method of Tumlinson et al. [12], system dynamic range was measured to be 66 db. Figure 6 shows the POCT image of the central portion of a contact lens. Two bright boundaries correspond to the air-lens and lens-air interfaces of the contact lens. The scan depth was 1 mm deep, and 1000 points per depth scan were obtained. Since the index of refraction of the contact lens was unknown, the figure has not been scaled by its index. The resultant depth in Fig. 6 gives the measured optical depth of the contact lens at 300 m. Figure 7(a) shows a cross section diagram of a silicon wafer with a small depression, which was measured at 50 m wide and 70 m deep by a profilometer. Figure 7(b) is the POCT image of the Fig. 8. POCT image of tangerine flesh. The tangerine s juice vacuoles are clearly visible. depression in the wafer. 750 points were acquired with each point corresponding to a depth of 1 m. Channels 3, 6, and 7 appear dim because of the angled nature of the target in that region. Some or all of the specular reflection from these sloped regions fell outside the range of the numerical aperture (NA) of the endoscope optics so only the small amount of diffuse light is measured. The depth of the depression was measured to be 75 m and the width 45 m in agreement with the independently measured trench parameters. Figure 8 is an image of tangerine (Citrus reticulata) flesh. The scan depth was 2 mm, and 1000 points per depth scan were obtained. The figure has been scaled assuming an average index of refraction of 1.34. The juice vacuole is surrounded by a thin membrane. The membrane outline is seen as high reflectivity structures in the POCT images. Approximately 80 200 m diameter vacuoles are visible and appear as dark regions in the POCT image. Figures 6 8 demonstrate the capability of the POCT system to image the depth, width, and or thickness of targets without the lateral scanning of the sample arm. Fig. 7. (a) Side view of a silicon (50 50 m inner square) depression with a depth of 70 m was measured by a profilometer. (b) POCT image of the depression showing a depth of 75 m. The width of the inner layer is 45 m. 4. Conclusions The system design and experimental results of a POCT system that is capable of acquiring an image without the need for mechanical scanning in the lateral dimension was demonstrated. The probe tip consists of a linear fiber array with 15 m diameter SMFs and an imaging GRIN rod lens with the fractional pitch of 0.48 and 1:1 magnification. When packaged the probe tip can fit in an assembled endoscope with a diameter that is less than 2 mm and provides a system transverse image resolution of 15 m at a wavelength of 1.31 m. 8295 APPLIED OPTICS Vol. 46, No. 34 1 December 2007

The advantages of this system are the very robust and potentially inexpensive probe, since there are no moving parts in the sample arm. The system is capable of very rapid image acquisition since all A scans of the image are acquired simultaneously. The disadvantages of the demonstrated system are the relatively small lateral range and the relatively small number of A scans per millimeter of lateral range. The former restriction is typical in forwardlooking probes, where the field of view is limited to less than the probe diameter for a rectangular image field, and the latter limit is typical of systems that use image bundles. For example, in our case 15 m is the smallest center-to-center fiber bundle spacing that could be used and maintain single mode operation with negligible cross talk. Given these characteristics, the developed system is best used in situations where imaging speed is valued over image size and lateral resolution. It would be ideal for high-speed metrology applications, for instance, measuring layer thicknesses, or in imageguided interventions, for instance, monitoring the depth of a laser ablation crater or determining the distance to critical structures during laser or conventional surgery. Arrays with up to 15 fibers have been fabricated in this study. However future work will involve expanding the number of fibers to 100, which will provide a larger transverse imaging field. By careful arrangement of the nonetched and tapered portion of the fibers, the width of a 100-fiber array will be less than 2 mm in diameter and suitable for use in standard diameter endoscope system. The variation l has to be made greater than the coherence length of the source between each channel. For the larger fiber array the variation between fiber lengths can be reduced to five to ten times the coherence length to minimize the overall fiber length difference in the system. A single source with the same power as the current system would not be useful in a 100-channel system. New sources with higher output power and lower cost are being constantly developed. A few high power sources would be expected to be utilized in the final 100-channel system. We have recently developed an array of complementary metal-oxide semiconductor (CMOS) photoreceiver and demodulation circuits [13] that can be scaled to 100 channels. In addition, integrated 3 db couplers in an ionexchanged technique [14,15] have been designed for the 100-channel POCT system. These developments will enable a compact POCT system with integrated electronic scanning capability. A LABVIEW program was used to facilitate length equalization of the paired sample and reference fibers. In future implementations, the POCT system can be modified by using a Fourier domain setup with a higher digitization bit count and a stationary reference and either a narrowband swept source or a broadband light source. Frequency domain OCT provides a signal-to-noise (SNR) advantage over the traditional time domain method we implemented in the POCT system, and also no moving parts required in the reference arm would lower system complexity [12,16]. Because the reference arm does not need to translate, an endoscopic common-path approach could be implemented [12] and the necessity for a separate reference arm, requiring individual matching of fiber lengths, could be eliminated. A useful Fourier domain setup of a 100-channel system will require the use of a detector array with approximately 100 2048 elements in order to image to a depth of 2 mm. Such a detector, with high speed and dynamic range, poses a technological challenge. A likelier Fourier domain arrangement is the utilization of a high power swept source, so that the detection subsystem is simplified to 100 detectors. The challenge then becomes high-speed signal acquisition and digital signal processing, for which the technology is much more mature. The demonstrated and proposed advancements will enable the realization of a simple endoscopic OCT system with no mechanical scanning to facilitate clinical use. The authors thank the National Institute of Health for providing financial support (grant EB01032) for this research and acknowledge the partial support received from Omid Mahdavi and Steve Orozco working in the Micro Nano Fabrication Center at the ECE Department at the University of Arizona. The authors would also like to thank Alexandre Tumlinson, Amy Winkler, and Garret Bonnema for their valuable suggestions. References 1. B. E. Bouma and G. J. Tearney, Handbook of Optical Coherence Tomography (Dekker, 2002). 2. G. Loeb and J. K. Barton, Imaging botanical subjects with optical coherence tomography: a feasibility study, Trans. ASAE 46, 1751 1757 (2003). 3. J. M. Schmitt, Optical coherence tomography (OCT): a review, IEEE J. Sel. Top. Quantum Electron. 5, 1205 1215 (1999). 4. A. F. Fercher, W. Drexler, C. K. Hitzenberger, and T. Lasser, Optical coherence tomography-principles and applications, Rep. Prog. Phys. 66, 239 303 (2003). 5. S. Bourquin, P. Seitz, and R. P. Salathe, Optical coherence topography based on a two-dimensional smart detector array, Opt. Lett. 26, 512 514 (2001). 6. T. Xie, D. Mukai, S. Guo, M. Brenner, and Z. Chen, Fiberoptic-bundle-based optical coherence tomography, Opt. Lett. 30, 1803 1805 (2005). 7. Y. Luo, J. E. Castillo, L. J. Arauz, J. K. Barton, and R. K. Kostuk, Coherent proximity sensor with high density fiber array, presented at Frontiers in Optics 2006, Rochester, N.Y. USA, 8 12 October 2006. 8. Corning SMF-28 Optical Fiber Product Information, Corning, Inc., N.Y., 2001. 9. Y. Luo, J. E. Castillo, L. J. Arauz, J. K. Barton, and R. K. Kostuk, Coupling and crosstalk effects in 12 15 m diameter single-mode fiber arrays for simultaneous transmission and photon collection from scattering media, Appl. Opt. 46, 253 261 (2007). 10. M. Scepanovic, J. E. Castillo, J. K. Barton, D. Mathine, R. K. Kostuk, and A. Sato, Design and processing of high-density single mode fiber arrays for imaging and parallel interferometer applications, Appl. Opt. 43, 4150 4156 (2004). 1 December 2007 Vol. 46, No. 34 APPLIED OPTICS 8296

11. L. J. Arauz, Y. Luo, J. E. Castillo, R. K. Kostuk, and J. K. Barton, 10-channel fiber array fabrication technique for parallel optical coherence tomography system, presented at SPIE Photonics West, San Jose, Calif., USA, 23 25 January 2007. 12. A. R. Tumlinson, J. K. Barton, B. Povazay, H. Sattman, A. Unterhuber, R. A. Leitgeb, and W. Drexler, Endoscope-tip interferometer for ultrahigh resolution frequency domain optical coherence tomography in mouse colon, Opt. Express 14, 1878 1887 (2006). 13. W. Xu, D. L. Mathine, and J. K. Barton, Analog CMOS design for optical coherence tomography signal detection and processing, IEEE Trans. Biomed. Eng. (to be published). 14. J. A. Frantz, J. T. A. Carriere, and R. K. Kostuk, Measurement of ion-exchanged waveguide burial depth with a camera, Opt. Eng. 43, 3149 3154 (2004). 15. J. T. A. Carriere, J. A. Frantz, B. R. West, S. Honkanen, and R. K. Kostuk, Bend loss effects in diffused, buried waveguides, Appl. Opt. 44, 1698 1703 (2005). 16. R. A. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, Performance of Fourier domain vs. time domain optical coherence tomography, Opt. Express 11, 889 894 (2003). 8297 APPLIED OPTICS Vol. 46, No. 34 1 December 2007