800W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Similar documents
Indoor Rack Mount. GaN Solid State Power Amplifiers 3RU Rack Height

300W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

150W Ku-Band Compact Outdoor 1:1 Redundant System. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

High Power Outdoor. GaN Solid State Power Amplifiers

500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies

125W Ku-Band Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

High Power Outdoor. GaAs Solid State Power Amplifiers

40W Ka-Band Compact Outdoor SSPA with AC Input Option B

500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies

High Power Outdoor. GaN Solid State Power Amplifiers

The New Standard in Outdoor High Power Redundant Microwave Amplifier Systems Has Arrived. Removable fan trays System is 100% field maintainable

4RU Rack Mountable. Solid State Power Amplifiers

The New Standard in Outdoor High Power Redundant Microwave Amplifier Systems Has Arrived. dundancy System Monitor and Control.

Phase Combined Systems

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

Compact Outdoor Solid State Power Amplifiers in S-, C-, X-, and Ku-Bands

Mini Compact Outdoor GaN SSPAs in C-, X-, and Ku-Bands

328 Innovation Blvd. 1 Wheaton Road, Witham

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

328 Innovation Blvd. 1 Wheaton Road, Witham

328 Innovation Blvd. 2&3 The Matchyns, London Road, Rivenhall End

C-Band Redundant LNA Systems

X-Band Redundant LNA Systems

Ku-Band VSAT Block Up Converters

VSAT Redundant System Solutions

C-Band VSAT Block Up Converters

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

Redundant LNA Systems

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

Ku-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.

KU-BAND OUTDOOR BLOCK CONVERTERS

INTRODUCTION STANDARD FEATURES. Option: High ambient temperature operation (up to 60 C) APPLICATION KU-BAND BOOSTER AMPLIFIER

1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS

Block Upconverters for Integration in High Power Amplifiers

100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

150W1000B. Features. 150 watts CW 80MHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

STA3318 Series StellarMini TM 180 W, Ku-Band Antenna Mount TWTA

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

Solid State Broadband High Power Amplifier

PowerMAX Redundant SSPA Systems. Soft-fail Redundancy Modular, Hot-swap Assemblies Indoor and Outdoor Packages

Solid State General Communication Power Amplifier

IQgig-RF TM Model B Technical Specifications

PARADISE DATACOM APPLICATION NOTE. Satellite Terminal System Planning using L Band Modems. AN_032 Issue 2

Amplifier HF MHz

Standard C-band 10W BUC MODEL No. NJT5762 series

Universal/Standard Ku-band 16W BUC MODEL No. NJT8319 series

The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum.

Converter VSAT Dual Band BDC ITAR Free Airborne Compact Block Down Converter MFC146

120W UHF Transmitter/Repeater

Ka-Band SSPA TSA GHz Airborne Applications

Amplifier Systems. Ultra Low Noise LNAs. Back to. C-band LNAs X-band LNAs Ku-band LNAs

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

IQgig-IF TM Technical Specifications

2 GHz to 6 GHz, 500 W Power Amplifier HMC8113

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Outdoor Terrestrial Transmitter / Repeater

TELEDYNE MICROWAVE SOLUTIONS. Summary. NF v1. the carrier (10MHz

PCN-1800 Series. VHF TV Transmitter. 2nd Edition

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

INSTALLATION AND OPERATING MANUAL

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series]

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

NA100 NA200 NA300. NA Series Frequency Agile Medium Wave Broadcast Transmitters

Appendix A: BLC-10/20/25 DC Models Packing

DVB-T/H Portable Test Transmitter

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

The RCB-2000 is a compact receiving system that combines two high-performance telemetry RF sections.

NI PXIe-5601 Specifications

Keysight Technologies N9320B RF Spectrum Analyzer

J kw AM Transmitter

Agilent N9320B RF Spectrum Analyzer

High Power Amplifier, Solid State, Broadband MHz, 51dB Gain, SMA Female Connectors, 1dB GCP. RAMP M-51d-Sf-80W-e7

SIR-4011 MICROWAVE WIDEBAND DSP RECEIVER. WIDE FREQUENCY RANGE: GHz

IQgig-RF TM Technical Specifications

ModuMAX High Power Amplifier Advancements

12B01A-D30 L- & S-Band Solid State Power Amplifier w/ 1 Watt Input Drive Level

HMC-T2240. Synthesized Signal Generator, 10 MHz to 40 GHz

Digital HF Receiver WJ-8723

khz to 2.9 GHz Spectrum Analyzer

Technical Datasheet GT-1000B Microwave Power Amplifier. 100 MHz to 20 GHz. Broadband High-Power Instrumentation Amplifier Rev.

Mission Critical DAS Solution

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

FREEDOM Communications System Analyzer R8100 DATA SHEET

FREEDOM Communications System Analyzer R8000C DATA SHEET

HighPowerTransmitter Module

GA GHz. Digital Spectrum Analyzer

Chapter 5 Specifications

ERI FM Band Pass Filters

GT-1000A Microwave Power Amplifier 2 GHz to 20 GHz. Broadband High-Power Instrumentation Amplifier. Preliminary Technical Datasheet

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

Ka Band Radar Transceiver

Transcription:

800W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply Teledyne Paradise Datacom has a rich history in the design and production of Gallium Nitride (GaN) based SSPAs. Our engineers utilize innovative linearization techniques that enable GaN amplifiers to produce linear output power with the same efficiency as tube based amplifier systems. A complete family of Satcom amplifiers has been developed that cover S-Band through Ku-Band. GaN amplifiers have a superior set of mutually beneficial characteristics, including: Higher Output Power Greater Power-Added Efficiency High Reliability These GaN amplifier modules are installed in the popular 3RU (5.25 inch high) Chassis, which features a front panel display and five fault condition LEDs that reflect some of the SSPA major fault states. Local/Remote and Mute/Unmute LEDs show the current control mode and mute state of the amplifier. A full compliment of remote monitor and control of the amplifier is available at the rear panel, including: RS-232/RS-485; Ethernet, with UDP and SNMP control; Web Browser TCP/IP; and Discrete hardware (parallel port) signals. FEATURES Extremely High Power Density: to 600 W S-Band to 800 W X-Band to 800 W C-Band to 500 W Ku-Band Removable Fan Tray and M&C Card Assembly Remote Communication via RS232/485 or Ethernet RF Output Sample Port 20 RF Gain Adjustment True RF Output Power Measurement 1RU N+1 Power Supply Built-in Maintenance Switch Controller OPTIONS Removable RF Module L-Band Input operation Reflected Power Monitor Input Sample Port Exhaust Duct Adapters Front Panel Power Switch Remote Control Panel System Configurations Teledyne Paradise Datacom Teledyne Paradise Datacom Ltd. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End State College, PA 16803 USA Witham, Essex CM8 3HA United Kingdom Tel: (814) 238-3450 Tel: +44(0) 1376 515636 Fax: (814) 238-3829 www.paradisedata.com Fax: +44(0) 1376 533764 PAGE 1 OF 9 214417 REV H ECO 18515

Frequency Range Indoor Rack Mount Specifications, S-Band SSPAs Output Power Typical, P sat Guaranteed minimum, P Linear 1 Power Requirements Line Frequency Line Power (Voltage) (typical @ 220 VAC) Receive Band Noise Power Density Frequency selection G Frequency selection A Frequency selection B HPAS3050ARXXXXPG2 HPAS3100ARXXXXPG2 HPAS3200ARXXXXPG2 HPAS3300ARXXXXPG2 HPAS3400ARXXXXPG2 HPAS3500ARXXXXPG2 HPAS3600ARXXXXPG2 power factor HPAS3050ARXXXXPG2 HPAS3100ARXXXXPG2 HPAS3200ARXXXXPG2 HPAS3300ARXXXXPG2 HPAS3400ARXXXXPG2 HPAS3500ARXXXXPG2 HPAS3600ARXXXXPG2 without optional filter with optional filter 1.750 to 2.120 2.020 to 2.120 2.200 to 2.300 47.0 (50) / 44.0 (25) 50.0 (100) / 47.0 (50) 53.0 (200) / 50.0 (100) 54.8 (300) / 51.8 (150) 56.0 (400) / 53.0 (200) 57.0 (500) / 54.0 (250) 57.8 (600) / 54.8 (300).98 47 to 63 400 / 300 (90 to 265) 500 / 400 (90 to 265) 800 / 700 (90 to 265) 1300 / 1000 (180 to 265) 2 2000 / 1300 (180 to 265) 2 2100 / 1500 (180 to 265) 2 2200 / 1700 (180 to 265) 2 PAGE 2 OF 9 214417 REV H ECO 18515-95 -155 Hz W / 4 KHz W / 4 KHz Note 1: P Linear = maximum output power at which third order intermodulation products < -25 c (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 c. Note 2: For 90 to 180 VAC operation, consult factory. Frequency Range Specifications, C-Band SSPAs Output Power Typical, P sat Guaranteed minimum, P Linear 1 Power Requirements Line Frequency Line Power (Voltage) (typical @ 220 VAC) Frequency selection L Frequency selection H Frequency selection C 2 Frequency selection A Frequency selection B 2 Frequency selection D HPAC3050ARXXXXPG2 HPAC3100ARXXXXPG2 HPAC3150ARXXXXPG2 HPAC3200ARXXXXPG2 HPAC3300ARXXXXPG2 HPAC3400ARXXXXPG2 HPAC3650ARXXXXPG2 HPAC3800ARXXXXPG2 power factor HPAC3050ARXXXXPG2 HPAC3100ARXXXXPG2 HPAC3150ARXXXXPG2 HPAC3200ARXXXXPG2 HPAC3300ARXXXXPG2 HPAC3400ARXXXXPG2 HPAC3650ARXXXXPG2 HPAC3800ARXXXXPG2 4.400 to 5.000 5.715 to 5.790 5.750 to 6.670 5.850 to 6.425 5.850 to 6.725 6.425 to 7.025 47.0 (50) / 44.0 (25) 50.0 (100) / 47.0 (50) 51.8 (150) / 48.8 (75) 53.0 (200) / 50.0 (100) 54.8 (300) / 51.8 (150) 56.0 (400) / 53.0 (200) 58.1 (650) / 55.1 (325) 59.0 (800) / 56.0 (400).98 47 to 63 500 / 400 (90 to 265) 600 / 500 (90 to 265) 1000 / 800 (90 to 265) 1100 / 880 (90 to 265) 1500 / 1300 (180 to 265) 3 1800 / 1600 (180 to 265) 3 3300 / 2800 (180 to 265) 3 4000 / 3500 (180 to 265) Hz Receive Band Noise Power Density without filter -155 W / 4 khz Note 1: P Linear = maximum output power at which third order intermodulation products < -25 c (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 c. Note 2: Output power decreases over the extended portion of the frequency range. Both P sat and P Linear de-rate by 1 from 5.85 to 5.75 and from 6.425 to 6.725. Note 3: For 90 to 180 VAC operation, consult factory.

Specifications, X-Band SSPAs Frequency Range Output Power Typical, P sat Guaranteed minimum, P Linear 1 Power Requirements Line Frequency Line Power (Voltage) (typical @ 220 VAC) Receive Band Noise Power Density Frequency selection F Frequency selection D Frequency selection A HPAX3300ARXXXXPG2 HPAX3400ARXXXXPG2 HPAX3650ARXXXXPG2 HPAX3800ARXXXXPG2 power factor Line frequency HPAX3300ARXXXXPG2 HPAX3400ARXXXXPG2 HPAX3650ARXXXXPG2 HPAX3800ARXXXXPG2 without optional filter with optional filter 7.10 to 7.40 7.70 to 8.40 7.90 to 8.40 54.8 (300) / 51.8 (150) 56.0 (400) / 53.0 (200) 58.1 (650) / 55.1 (325) 59.0 (800) / 56.0 (400).98 47 to 63 1500 / 1300 (180 to 265) 2 2000 / 1700 (180 to 265) 2 3300 / 2800 (180 to 265) 2 4000 / 3500 (180 to 265) -85-155 Hz W / 4 khz W / 4 khz Note 1: P Linear = maximum output power at which third order intermodulation products < -25 c (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 c. Note 2: For 90 to 180 VAC operation, consult factory. Specifications, Ku-Band SSPAs Frequency Range Output Power Typical, P sat Guaranteed minimum, P Linear 1 Power Requirements Line Frequency Line Power (Voltage) (typical @ 220 VAC) Frequency selection F Frequency selection B Frequency selection A Frequency selection C Frequency selection D HPAK3040ARXXXXPG2 HPAK3050ARXXXXPG2 HPAK3080ARXXXXPG2 HPAK3100ARXXXXPG2 HPAK3150ARXXXXPG2 HPAK3200ARXXXXPG2 HPAK3250ARXXXXPG2 HPAK3300ARXXXXPG2 HPAK3400ARXXXXPG2 HPAK3500ARXXXXPG2 power factor Line frequency HPAK3040ARXXXXPG2 HPAK3050ARXXXXPG2 HPAK3080ARXXXXPG2 HPAK3100ARXXXXPG2 HPAK3150ARXXXXPG2 HPAK3200ARXXXXPG2 HPAK3250ARXXXXPG2 HPAK3300ARXXXXPG2 HPAK3400ARXXXXPG2 HPAK3500ARXXXXPG2 12.75 to 13.25 13.75 to 14.50 14.00 to 14.50 14.50 to 14.70 15.10 to 15.40 46.0 (40) / 43.0 (20) 47.0 (50) / 44.0 (25) 49.0 (80) / 46.0 (40) 50.0 (100) / 47.0 (50) 51.8 (150) / 48.8 (75) 53.0 (200) / 50.0 (100) 54.0 (250) / 51.0 (125) 54.8 (300) / 51.8 (150) 56.0 (400) / 53.0 (200) 57.0 (500) / 54.0 (250).98 47 to 63 500 / 400 (90 to 265) 600 / 500 (90 to 265) 730 / 585 (90 to 265) 900 / 750 (90 to 265) 1000 / 850 (90 to 265) 1200 / 920 (90 to 265) 1500 / 1000 (180 to 265) 3 2000 / 1500 (180 to 265) 3 2500 / 1700 (180 to 265) 3 3000 / 2000 (180 to 265) 3 Hz Receive Band Noise Power Density 2-155 W / 4 khz Note 1: P Linear = maximum output power at which third order intermodulation products < -25 c (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 c. Note 2: All Ku-Band SSPAs are fitted with a receive band reject bulkhead filter, standard. An optional pressure window is available. Note 3: For 90 to 180 VAC operation, consult factory. PAGE 3 OF 9 214417 REV H ECO 18515

Gain Gain Flatness Gain Slope Indoor Rack Mount Common Electrical Specifications Gain Variation vs. Temperature Gain Stability Gain Adjustment Intermodulation Distortion (Two-tone, 5 MHz spacing) range full band full band (Extended C-Band) full band (S-Band) per 40 MHz per 10 MHz (S-band) 0 C to +50 C at constant temperature 0.1 resolution 55-75 ± 1.0 ± 1.5 ± 0.75 ± 0.3 ± 0.3 ± 1.0 ± 0.25 20 /40 MHz /10 MHz /24 hours At P Linear (P sat - 3 ) -25 c AM/PM Conversion @ rated P Linear 1.0 Spurious Harmonics (SSPA only) Input/Output VSWR Noise Figure Group Delay (per 40 MHz segment) Transmit Band Noise Output Power Density Residual AM Noise, typical Residual Phase Noise, typical (SSPA only) True RF Power Detector @ rated P Linear @ rated P Linear @ rated P Linear (S-Band) Extended C-Band Output VSWR: Ku-Band with bulkhead filter at maximum gain at maximum gain (S-Band) Linear Parabolic Ripple -65-50 -30 1.30:1 1.50:1 1.40:1 10 8 0.01 0.003 1.0 o / c c c ns/mhz ns/mhz 2 ns p-p TX Band -75 W/4 KHz Offset frequency from carrier 1 Hz 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz Range Accuracy -110-120 -130-135 -140-140 -140-90 -100-110 -120-125 -130 P sat to (P sat - 20) ± 0.75 m 1RU N+1 Redundant Power Supply The combination of a separate, fully redundant power supply is an excellent means of obtaining the ultimate in system reliability. The power supply is an N+1 redundant configuration, meaning that there is one more power supply module available than required to operate the SSPA. A failure of one power supply module will not take the amplifier off the air. PAGE 4 OF 9 214417 REV H ECO 18515

L-Band Operation Teledyne Paradise Datacom amplifiers are available with an integrated L-Band Block Up Converter. L-Band units utilize Teledyne Paradise Datacom s proprietary zbuc technology. The addition of a zbuc converter to the SSPA typically increases the gain by 2-4. The advantages of zbuc technology include: zbuc converter can detect and switch to an extenally supplied reference. Optional internal high stability (10MHz) reference. zbuc converter can lock to an externally supplied reference of 10 or 50 MHz. zbuc converter can accept a wide range of external reference power (-10 to +5 m). Electrical Specifications for 3RU RM SSPA with ZBUC converter Gain Gain Flatness Gain Slope Gain Adjusted Range Gain Stability Phase Noise Spurious Nominal setting full band (C-,X-,Ku-bands) per 40 MHz (C-,X-,Ku-bands) Typical C-Band Adj. Range Typical Ku-Band Adj. Range -40 to +60 C Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz Available Frequency Plans Band Frequency Plan IF Input LO Frequency RF Output C Sub-Band A 950-1525 MHz 4.900 5.850-6.425 C Sub-Band B 950-1825 MHz 4.900 5.850-6.725 C Sub-Band C 950-1870 MHz 4.800 5.750-6.670 C Sub-Band E 950-1250 MHz 5.475 6.425-6.725 C Sub-Band F 950-1250 MHz 5.775 6.725-7.025 C Sub-Band L 950-1550 MHz 3.450 4.400-5.000 X Sub-Band A 950-1450 MHz 6.950 7.900-8.400 Ku Sub-Band A 950-1450 MHz 13.050 14.00-14.50 Ku Sub-Band B 950-1700 MHz 12.800 13.75-14.50 Ku Sub-Band F 950-1450 MHz 11.800 12.75-13.25 Absolute max. -30-60 -70-80 -90-90 In-Band Signal Related (C-/Ku-Band) (Extended C-Band) Close to Carrier Spurious ( 20 MHz) Local Oscillator C-band (typ.) -60-74 -84-100 -105-125 75 ± 2.0 ± 0.5 20 60-80 57-77 ± 1.5 X-band (typ.) -58-70 -80-94 -97-122 -50-40 -50-30 Ku-band (typ.) -56-67 -78-91 -94-120 /40 MHz c c c m Noise Figure At Maximum gain 20 Transmit Band Noise Output Power Density Tx Band at Maximum gain -65 W/4kHz Input VSWR L-Band 1.5 : 1 Internal Reference Option Reference Accuracy (initial) Aging per day (after 30 days) ± 1 10-8 ± 1 10-9 Aging per year (after 30 days) ± 6 10-8 Reference Stability over Temperature (-40 to +40 C, ambient) ± 1 10-8 PAGE 5 OF 9 214417 REV H ECO 18515

Outline Drawing, Typical, 3RU Ku-Band SSPA with N+1 Redundant Power Supply PAGE 6 OF 9 214417 REV H ECO 18515

Mechanical Specifications Size (SSPA) width X height X depth 19.0 x 5.22 x 24.13 483 x 133 x 613 Size (Power Supply) width X height X depth 19.0 x 1.75 x 15.97 483 x 45 x 406 Weight (SSPA) Typical (± 3%) With integrated zbuc converter 75 (34) +1.7 (+0.8) inches mm inches mm lbs. (kg) lbs. (kg) Weight (Power Supply) with four (4) power supply modules 29 (13.2) lbs.(kg) Finish Paint Gray; powder coat Connectors RF Input RF Output (S-Band) RF Output (C-Band) RF Output (X-Band) RF Output (Ku-Band) RF Output Sample Type N Type N WR137 Waveguide WR112 Waveguide WR75 Waveguide Type N Female Female CPR137G Flange (PDR-70) CPR112G Flange (PDR-84) Grooved flange (PBR-120) Female Environmental Specifications Operating Temperature Storage Temperature Ambient 0 to +50-20 to +75 Operating Relative Humidity Non-condensing 95 % Cooling System Forced Convection Air Cooling Front Panel - Intake Rear Panel - Exhaust Audible Noise Measured 1m from unit, at P sat 71 A Altitude No temperature de-rating up to 10,000 ft, (3000 m) De-rate maximum temperature by 2 C per 1,000 ft (300 m) beyond 10,000 ft. C C Receive Band Filter Options S-Band A 1.75 B 0.81 1.38 0.69 2.020-2.120 (Band A) : Filter L205250-S3-TX Dimensions: A=9.972, B=8.500 2.200-2.300 (Band B) : Filter L205250-S4-TX Dimensions: A=12.222, B=10.750 1.750-2.120 (Band G) : Filter L205250-S11-TX Dimensions: A=4.730, B=3.250 X-Band 2.42 0.79 8.26 1.96 0.98 1.28 9.83 PAGE 7 OF 9 214417 REV H ECO 18515

Redundant and Phase Combined Systems Teledyne Paradise Datacom s 3RU Rack Mount SSPAs can be configured in a variety of redundant and phase combined configurations. 1:1 Redundant System with Internal Redundancy Control 1:1 Redundant System with RCP2-1100 Redundant System Controller 1:1 Fixed Phase Combined System with FPRC-1100 Phase Combined System Controller 1:2 Redundant System with Internal Redundancy Control 1:2 Redundant System with RCP2-1200 Redundant System Controller 1:2 Fixed Phase Combined System with FPRC-1200 Phase Combined System Controller System Output Power Capacity Due to residual losses inherent in redundant system configurations (waveguide bends; switch and coupler losses), reduce the typical output power specification of a single amplifier by approximately 0.2 for 1:1 and by 0.4 for 1:2 systems. In phase combined systems, these same losses result in slightly less than the ideal addition of 3 to the output power of a single HPA unit. For 1:1 phase combined systems, the typical additive output power is approximately 2.70 above the output power of a single HPA. For 1:2 phase combined systems, the typical additive output power is approximately 2.50 above the output power of a single HPA. Actual system losses will vary based on the system options. System Controllers The RCP2/FPRC-1100/1200 system controller provides an extremely user friendly interface for complete monitor and control of the amplifier system. RCP2-1100 Redundant System Controller The front panel mimic display shows the on-line amplifiers and the switch positions. Fault lights are provided for easy identification of system status. All system monitor and control is available locally at the front panel LCD display, as well as remotely by the RS232, RS485, or Ethernet interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel of the controller. Proprietary and Confidential The informa on contained in this document is the sole property of Teledyne Paradise Datacom. Any reproduc on in part or as a whole without the wri en permission of Teledyne Paradise Datacom is prohibited. PAGE 8 OF 9 214417 REV H ECO 18515

Rack Height 3RU 3 Band S-Band C-Band X-Band S C X Ku-Band K Power Level (Watts) 050, 100, 200, 300, 400, S-Band 500, 600 050, 100, 150, 200, 300, C-Band 400, 650, 800 X-Band 300, 400, 650, 800 040, 050, 080, 100, 150, Ku-Band 200, 250, 300, 400, 500 Indoor Rack Mount Part Number Configuration Matrix Standalone Unit or System Package R Standalone amplifier S System with Cabinet, Top Mounted Waveguide Switching T System without Cabinet, Top Mounted Waveguide Switching Y System with Cabinet, Rear Mounted Waveguide Switching Z System without Cabinet, Rear Mounted Waveguide Switching MODEL: HPA C 3 3 0 0 A R M X X X P G 2 A B G A 1 B 1 C 1 E 1 F 1 H L 1 S-Band 2.02 to 2.12 2.20 to 2.30 GHZ 1.75 to 2.12 C-Band 5.850 to 6.425 5.850 to 6.725 5.750 to 6.670 6.425 to 6.725 6.725 to 7.025 5.715 to 5.790 4.400 to 5.000 Frequency Sub Band A 1 D F A 1 B 1 F 1 G X-Band 7.90 to 8.40 7.70 to 8.40 7.10 to 7.40 Ku-Band 14.00 to 14.50 13.75 to 14.50 12.75 to 13.25 14.75 to 15.25 1 Available with optional BUC Standalone Unit or System Configuration X Standalone amplifier A 1 1:1 Redundant System, Input Switching, Internal Control B 1:1 Redundant System, Input Splitter, Internal Control C 1 1:2 Redundant System, Input Switching, RCP2-1200 2 1:2 Redundant System, Input Switching, Internal Control E 1:2 Phase Combined System, Input Splitter, FPRC-1200 2 D 1 F 1:1 Redundant System, Input Splitter, RCP2-1100 2 G 1:1 Phase Combined system, Input Splitter, FPRC-1100 2 H 1 1:1 Redundant System, Input Switching, RCP2-1100 2 J 1:2 Phase Combined system, Input splitter, Internal Control 1 Switched input with external reference BUC requires reference distribution box. 2 Standard location for controller is directly above HPA1. Block Up Converter PAGE 9 OF 9 214417 REV H ECO 18515 P L M P X Internal Reference BUC External Reference BUC No BUC Configuration Modifier 3 Standard (N+1 Power Supply) N+1 P.S. + Rear Exhaust Adapters X P R 1 V A 1 B C 1 D 1 GaN Device Designator G GaN Device Configuration Modifier 2 Standard Front Panel Power Switch Rx Band Reject Filter Reflected Power Monitor P + R (see above) P + V (see above) V + R (see above) P + R + V (see above) 1 S-Band and X-Band units only Configuration Modifier 1 X K S C Standard 110 VAC Operation Input Sample Port K + S (see above) Use and Disclosure of Data The items described herein are controlled by the U.S. Government and authorized for export only to the country of ul mate des na on for use by the ul mate consignee or end user(s) herein iden fied. They may not be resold, transferred, or otherwise disposed of, to any other country or to any person other than the authorized ul mate consignee or end user(s), either in their original form or a er being incorporated into other items, without first obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regula ons. Specifica ons are subject to change without no ce.