ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Similar documents
CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX



Magneto-resistive sensors


06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Edition March 2011 With publication of this catalogue all former printed general catalogues about RECHNER sensors are invalid.

Binary Output Series 9175

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Binary Output without Power Supply Series 9176

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolating Repeater Input Series 9163

Isolators A3/1.

Temperature Input Module for Zone 1 Series 9482/32

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Analog Universal Module HART for Zone 2 Series 9468/33

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

SHORTFORM CATALOGUE. DIN EN Reg.-No. DAT-P-048/ Testing laboratory accredited according to

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Output Module for Zone 2 Series 9470/33

Fieldbus Isolating Repeater Series 9185/11

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Digital Input Output Module for Zone 1 Series 9470/32

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators A3/1.

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

SINEAX TI 807 Passive DC signal isolator

Inductive sensor slot-type SI2-K08-AP7

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Two-channel safety barriers Series 9002

SINEAX B 811 Power Pack with additional Functions

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Two-channel safety barriers Series 9002

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Remote I/O. 74 Remote I/O. Remote I/O System

Head mounted Temperature Transmitter TF02/TF02-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Single-Channel Safety Barriers Series 9001

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

... for hydraulic and general applications in hazardous areas

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Assembly. Front view. HiC2441. SL2 1b. Termination Board

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Operating Instructions

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Temperature Transmitter itemp RTD DIN rail TMT 127

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Assembly. Front view. Switch Power Rail

SALES SERVICE +358 (0)

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Assembly. Front view. Power Rail

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Digital I/O Coupler (4-wire) Series 9413/21

Safety Instructions Nivotester FTC625, FTC325

Rail mounted Temperature Transmitter TH102/TH102-Ex

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Temperature transmitter itemp RTD DIN rail TMT 127

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Assembly. Front view. Switch Power Rail

Technical Data. General specifications. Rated operating distance s n 3 mm

Type Nominal voltage (V) Code HSV V

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

onlinecomponents.com

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Assembly. Front view. Parametrization interface. Power Bus

Level Measurement. Applications. Special features. Description

PRetrans Table of contents

Submersible pressure sensor For oils and fuels Model LF-1

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Operating Instructions

RMA42. Technical Information

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Temperature transmitter itemp PCP DIN rail TMT 121

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Transcription:

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services of the Electrical Industry ZVEI shall apply, along with the supplementary conditions extended reservation of proprietary rights, together with the supplements listed on our order confirmations and/or invoices. All specifications are subject to change without notice. Reprint, even in part, only with our consent. RECHNER Germany 2017GB - Printed in EU, all rights reserved. Edition 2017 With publication of this catalogue all former printed catalogues about RECHNER isolating switching amplifiers and power supplies are invalid. All specifications are subject to change without notice. (2017 2

TABLE OF CONTENTS ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES Pages DESCRIPTION ISOLATING SWITCHING AMPLIFIERS SERIES N-132... 4 ISOLATING SWITCHING AMPLIFIERS SERIES N-132... 6-14 DESCRIPTION POWER SUPPLIES SERIES EG...-130... 16 POWER SUPPLIES SERIES EG...-130... 18-22 ACCESSORIES 24-25 TYPE SELECTION IN ARTICLE NUMBER ORDER 26 TYPE SELECTION IN DESCRIPTION ORDER 26 All specifications are subject to change without notice. (2017 3

ISOLATING SWITCHING AMPLIFIER SERIES N-132... The Series N-132... isolating switching amplifiers (Ex Barrier transmit switching operations from an intrinsically safe control circuit to a non-intrinsically safe active current circuit. The control units are designed according to NAMUR-DIN 19234 or EN 60947-5-6 intrinsically safe and according to IEC 60079 [Ex ia] II C. The conformity is certified in Germany by DEKRA EXAM GmbH. Power pack, switching amplifier, electronic evaluation unit and output relay are all integrated in the 17.6 mm sized housing. The units are EMC-approved according to IEC 61000-4-2 to 5. Quick mounting is possible on profile according to NS35/15 or NS35/7,5. LED displays are integrated in the front plate for stand-by (green, state of output (yellow and wire-break / shortcircuit of the sensor cable (red. The isolating switching amplifiers can be actuated by NAMUR sensors, e.g. our series IAS-30...and KAS- 40... or by mechanical contacts. All specifications are subject to change without notice. (2017 4

ISOLATING SWITCHING AMPLIFIERS SERIES N-132... Pages: ISOLATING SWITCHING AMPLIFIERS SERIES N-132... 6-12 TRANSMITTER POWER SUPPLY SERIES N-132... 13-14 All specifications are subject to change without notice. (2017 5

114,5 Isolating Switching Amplifier N-132/1-01 120...230 V AC To connect one NAMUR-Sensor or potential-free mechanical contact, which is mounted in the zones 0, 1, 2 (Gas or 20, 21, 22 (dust Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or shortcircuit via LED display Certificate: DMT 09 ATEX E 087X IECEx BVS 10.0088X II (1 G [Ex ia] IIC II (1 D [Ex ia] IIIC [Ex ia] IIC [Ex ia] IIIC Operating voltage (U B 120...230 V AC Output function 1 x change-over contact potential-free Contact rating each relay AC max. 250 V AC / 4 A Contact rating each relay DC max. 250 V DC / 2 A Type N-132/1-01 Art.-No. N 00012 No-load current (I o Typ. 12 ma No-load voltage max. (U o 9.6 V DC Short-circuit current max. (I K Outer inductance max. (L o 10 ma [Ex ia] IIC 350 mh / IIB 1000 mh Outer capacitance max. (C o [Ex ia] IIC 3.6 µf / IIB 26 µf Actuating signal NAMUR EN 60547-5-6 Permitted ambient temperature -20...+70 C Display Degree of protection IC 60529 Red / yellow and green Housing: IP 30 Terminals: IP 20 Norm EN 60947-5-6 Connection Screw terminals 6 108 99 17,6 Ex - Area Division 1 Zone 0 / 1 Sensor Ex barrier Safe Area SPS / PLS Made in Germany All specifications are subject to change without notice. (2017

114,5 Isolating Switching Amplifier N-132/1-10 24 V DC To connect one NAMUR-Sensor or potential-free mechanical contact, which is mounted in the zones 0, 1, 2 (Gas or 20, 21, 22 (dust Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or shortcircuit via relay contact Certificate: DMT 09 ATEX E 087X IECEx BVS 10.0088X II (1 G [Ex ia] IIC II (1 D [Ex ia] IIIC [Ex ia] IIC [Ex ia] IIIC Operating voltage (U B 18...31.2 V DC Output function 1 x change-over contact potential-free Contact rating each relay AC max. 250 V AC / 4 A Contact rating each relay DC max. 250 V DC / 2 A Type N-132/1-10 Art.-No. N 00014 No-load current (I o Typ. 33 ma No-load voltage max. (U o 9.6 V DC Short-circuit current max. (I K Outer inductance max. (L o 10 ma [Ex ia] IIC 350 mh / IIB 1000 mh Outer capacitance max. (C o [Ex ia] IIC 3.6 µf / IIB 26 µf Actuating signal NAMUR EN 60547-5-6 Permitted ambient temperature -20...+70 C Display Degree of protection IC 60529 Red / yellow and green Housing: IP 30 Terminals: IP 20 Norm EN 60947-5-6 Connection Screw terminals All specifications are subject to change without notice. (2017 108 99 17,6 Ex - Area Division 1 Zone 0 / 1 Sensor Ex barrier Safe Area SPS / PLS Made in Germany 7

114,5 Isolating Switching Amplifier N-132/1(2-01 120...230 V AC To connect one NAMUR-Sensor or potential-free mechanical contact, which is mounted in the zones 0, 1, 2 (Gas or 20, 21, 22 (dust With 2 relay outputs. Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or shortcircuit via LED display Certificate: DMT 09 ATEX E 087X IECEx BVS 10.0088X II (1 G [Ex ia] IIC II (1 D [Ex ia] IIIC [Ex ia] IIC [Ex ia] IIIC Operating voltage (U B 120...230 V AC Output function 2 x change-over contact potential-free Contact rating each relay AC max. 250 V AC / 4 A Contact rating each relay DC max. 250 V DC / 2 A Type N-132/1(2-01 Art.-No. N 00021 No-load current (I o Typ. 12 ma No-load voltage max. (U o 9.6 V DC Short-circuit current max. (I K Outer inductance max. (L o 10 ma [Ex ia] IIC 350 mh / IIB 1000 mh Outer capacitance max. (C o [Ex ia] IIC 3.6 µf / IIB 26 µf Actuating signal NAMUR EN 60547-5-6 Permitted ambient temperature -20...+70 C Display Degree of protection IC 60529 Red / yellow and green Housing: IP 30 Terminals: IP 20 Norm EN 60947-5-6 Connection Screw terminals 8 108 99 17,6 Ex - Area Division 1 Zone 0 / 1 Sensor Ex barrier Safe Area SPS / PLS Made in Germany All specifications are subject to change without notice. (2017

114,5 Isolating Switching Amplifier N-132/2-01 120...230 V AC To connect two NAMUR-Sensors or potential-free mechanical contacts, which are mounted in the zones 0, 1, 2 (Gas or 20, 21, 22 (dust Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or shortcircuit via LED display Certificate: DMT 09 ATEX E 087X IECEx BVS 10.0088X II (1 G [Ex ia] IIC II (1 D [Ex ia] IIIC [Ex ia] IIC [Ex ia] IIIC Operating voltage (U B 120...230 V AC Output function 2 x change-over contact potential-free Contact rating each relay AC max. 250 V AC / 4 A Contact rating each relay DC max. 250 V DC / 2 A Type N-132/2-01 Art.-No. N 00015 No-load current (I o Typ. 18 ma No-load voltage max. (U o 9.6 V DC Short-circuit current max. (I K Outer inductance max. (L o 20 ma [Ex ia] IIC 90 mh / IIB 340 mh Outer capacitance max. (C o [Ex ia] IIC 3.6 µf / IIB 26 µf Actuating signal NAMUR EN 60547-5-6 Permitted ambient temperature -20...+70 C Display Degree of protection IC 60529 Red / yellow and green Housing: IP 30 Terminals: IP 20 Norm EN 60947-5-6 Connection Screw terminals All specifications are subject to change without notice. (2017 108 99 17,6 Ex - Area Division 1 Zone 0 / 1 Sensor Ex barrier Safe Area SPS / PLS Made in Germany 9

114,5 Isolating Switching Amplifier N-132/2-10 24 V DC To connect two NAMUR-Sensors or potential-free mechanical contacts which are mounted in the zones 0, 1, 2 (Gas or 20, 21, 22 (dust Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or shortcircuit via relay contact Certificate: DMT 09 ATEX E 087X IECEx BVS 10.0088X II (1 G [Ex ia] IIC II (1 D [Ex ia] IIIC [Ex ia] IIC [Ex ia] IIIC Operating voltage (U B 18...31.2 V DC Output function 2 x change-over contact potential-free Contact rating each relay AC max. 250 V AC / 4 A Contact rating each relay DC max. 250 V DC / 2 A Type N-132/2-10 Art.-No. N 00017 No-load current (I o Typ. 55 ma No-load voltage max. (U o 9.6 V DC Short-circuit current max. (I K Outer inductance max. (L o 20 ma [Ex ia] IIC 90 mh / IIB 340 mh Outer capacitance max. (C o [Ex ia] IIC 3.6 µf / IIB 26 µf Actuating signal NAMUR EN 60547-5-6 Permitted ambient temperature -20...+70 C Display Degree of protection IC 60529 Red / yellow and green Housing: IP 30 Terminals: IP 20 Norm EN 60947-5-6 Connection Screw terminals 10 108 99 17,6 Ex - Area Division 1 Zone 0 / 1 Sensor Ex barrier Safe Area SPS / PLS Made in Germany All specifications are subject to change without notice. (2017

114,5 Isolating Switching Amplifier N-132/1-E-10 24 V DC To connect one NAMUR-Sensor or potential-free mechanical contact, which is mounted in the zones 0, 1, 2 (Gas or 20, 21, 22 (dust Amplifier for use in areas with the risk of gas explosion, zone 2 Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or shortcircuit via relay contact Certificate: DMT 09 ATEX E 087X IECEx BVS 10.0088X II (1 G [Ex ia] IIC II (1 D [Ex ia] IIIC Ex nac ncc [ia] IIC T4 [Ex ia] IIIC Operating voltage (U B 18...31.2 V DC Output function 1 x transistor output / open collector Contact rating each DC output max. 35 V DC / 50 ma Type N-132/1-E-10 Art.-No. N 00022 No-load current (I o Typ. 26 ma No-load voltage max. (U o 9.6 V DC Short-circuit current max. (I K Outer inductance max. (L o 10 ma [Ex ia] IIC 350 mh / IIB 1000 mh Outer capacitance max. (C o [Ex ia] IIC 3.6 µf / IIB 26 µf Actuating signal NAMUR EN 60547-5-6 Permitted ambient temperature -20...+70 C Display Degree of protection IC 60529 Red / yellow and green Housing: IP 30 Terminals: IP 20 Norm EN 60947-5-6 Connection Screw terminals All specifications are subject to change without notice. (2017 108 99 17,6 Ex - Area Division 1 Zone 0 / 1 Sensor Ex barrier Safe Area Division 2 Zone 2 SPS / PLS Made in Germany 11

114,5 Isolating Switching Amplifier N-132/2-E-10 24 V DC To connect two NAMUR-Sensors or potential-free mechanical contacts which are mounted in the zones 0, 1, 2 (Gas or 20, 21, 22 (dust. Amplifier for use in areas with the risk of gas explosion, zone 2 Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or short-circuit via relay contact Certificate: DMT 09 ATEX E 087X IECEx BVS 10.0088X II (1 G [Ex ia] IIC II (1 D [Ex ia] IIIC Ex nac ncc [ia] IIC T4 [Ex ia] IIIC Operating voltage (U B 18...31.2 V DC Output function 2 x transistor output / open collector Contact rating each DC output max. 35 V DC / 50 ma Type N-132/2-E-10 Art.-No. N 00018 No-load current (I o Typ. 36 ma No-load voltage max. (U o 9.6 V DC Short-circuit current max. (I K Outer inductance max. (L o 20 ma [Ex ia] IIC 90 mh / IIB 340 mh Outer capacitance max. (C o [Ex ia] IIC 3.6 µf / IIB 26 µf Actuating signal NAMUR EN 60547-5-6 Permitted ambient temperature -20...+70 C Display Degree of protection IC 60529 Red / yellow and green Housing: IP 30 Terminals: IP 20 Norm EN 60947-5-6 Connection Screw terminals 12 108 99 17,6 Ex - Area Division 1 Zone 0 / 1 Sensor Ex barrier Safe Area Division 2 Zone 2 SPS / PLS Made in Germany All specifications are subject to change without notice. (2017

114,5 Transmitter Power Supply N-132/1/4-20-IL - Analogue Output 4...20 ma For connection of 1 ATEX certified 2-wire analogue sensor e. g. our KAS-40...IL with 4...20 ma output signal Transmitter for use in areas with the risk of gas explosion, zone 2 Galvanic isolation between input, output and power supply Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or shortcircuit via relay contact Certificate: DMT 09 ATEX E 129X IECEx BVS 10.0087X II 3 (1 G Ex na nc [ia] IIC T4 II (1 D [Ex iad] Ex na nc [ia Ga] IIC T4 Gc [Ex ia Da] IIIC All specifications are subject to change without notice. (2017 Type 108 99 17,6 N-132/1/4-20-IL Art. No. N 00020 Safety Data (CENELEC Power supply Ex i Input Output Ambient conditions LED-Display Degree of protection IEC 60529 Max. voltage U 0 Max. current I 0 Max. power P 0 Internal capacitance C i and inductance L i Max. connectable capacitance C 0 IIC / IIB Max. connectable inductance L o IIC / IIB Insulation voltage U m Nominal voltage U N Voltage range Nominal current (with U N and I Amax Power consumption (with U N and I Amax Transmitter supply voltage Input signal Resistance range (load Output range Made in Germany 27 V 88 ma 576 mw Negligible 90 nf / 705 nf 2.3 mh / 14 mh 253 V 24 V DC 18...31.2 V DC 70 ma 1.7 W 16 V 0/4...20 ma 600 Ω 0/4...20 ma Ambient temperature -20...+70 C Storage temperature -40...+80 C Relative humidity (no condensation < 95 % Red / yellow and green Housing: IP30 Terminals: IP20 Norm EN 60947-5-6 Connection Ex - Area Division 1 Zone 0 / 1 Sensor Ex barrier Screw terminals Safe Area Division 2 Zone 2 SPS / PLS 13

114,5 Transmitter Power Supply N-132/2/4-20-IL - Analogue Output 4...20 ma For connection of 2 ATEX certified 2-wire analogue sensors e. g. our KAS-40...IL with 4...20 ma output signal Transmitter for use in areas with the risk of gas explosion, zone 2 Galvanic isolation between input, output and power supply Compact design - only 17.6 mm width Removable screw terminals Indication sensor wire-break or shortcircuit via relay contact Certificate: DMT 09 ATEX E 129X IECEx BVS 10.0087X II 3 (1 G Ex na nc [ia] IIC T4 II (1 D [Ex iad] Ex na nc [ia Ga] IIC T4 Gc [Ex ia Da] IIIC 14 Type 108 Ex - Area 99 17,6 Division 1 Zone 0 / 1 Sensor Ex barrier N-132/2/4-20-IL Art. No. N 00023 Safety Data (CENELEC Power supply Ex i Input Output Ambient conditions LED-Display Degree of protection IEC 60529 Max. voltage U 0 Max. current I 0 Max. power P 0 Internal capacitance C i and inductance L i Max. connectable capacitance C 0 IIC / IIB Max. connectable inductance L o IIC / IIB Insulation voltage U m Nominal voltage U N Voltage range Nominal current (with U N and I Amax Power consumption (with U N and I Amax Transmitter supply voltage Input signal Resistance range (load Output range Safe Area Division 2 Zone 2 SPS / PLS Made in Germany 27 V 88 ma 576 mw Negligible 90 nf / 705 nf 2.3 mh / 14 mh 253 V 24 V DC 18...31.2 V DC 125 ma 3 W 16 V 0/4...20 ma 600 Ω 0/4...20 ma Ambient temperature -20...+70 C Storage temperature -40...+80 C Relative humidity (no condensation < 95 % Red / yellow and green Housing: IP30 Terminals: IP20 Norm EN 60947-5-6 Connection Screw terminals All specifications are subject to change without notice. (2017

All specifications are subject to change without notice. (2017 15

POWER SUPPLIES - SERIES EG-...-130... The EG...-130-... series control units contain a DC-side short-circuit protected power pack, voltage stabiliser and output relay. The 22 mm small housing is designed for quick mounting on DIN 46 277 profiles (housing size 70 mm for EG III-... LED displays are integrated in the front panel for stand-by and state of output. When a sensor is connected to the unit, it automatically recognises whether the sensor is PNP or NPN output. These control units can be actuated by all 2, 3 and 4-wire sensors with PNP, NPN, NO, NC or antivalent function, i. e. our series IAS-10..., IAS-20..., IAS-60..., KAS-70..., KAS-80..., KAS-90..., IS-120... and SW-600. The model EG III-130 can also be connected to one of our KXA-.../ KFA-... or KFX-... sensor systems. Details of the parameters to be considered when connecting these systems, are available on request. 16 All specifications are subject to change without notice. (2017

POWER SUPPLIES SERIES EG...-130... Pages: POWER SUPPLIES SERIES EG...-130... 18-22 All specifications are subject to change without notice. (2017 17

107 522000 EGI-130 Power Supply EG I-130 Series 130 - Relay Output To connect one 2, 3 or 4-wire sensor with NPN or PNP transistor output (not from our series SW-600. When connecting an antivalent sensor (4-wire the NO or NC output can be connected. With one output relay (1 x change over Certificate: Operating voltage (U B No-load current (I o Output function Contact rating each relay max. Type 115 / 230 V AC ± 15 % 40...60 Hz Typ. 20 ma 1 x potential-free change-over contact 250 V AC / 6A EGI-130 Art.-No. 522 000 Actuating voltage (U S 24 V DC ± 20 % Actuating current max. (I S Residual ripple acc. to DIN 41 755 max. 2 % Actuating signal 60 ma PNP or NPN Permitted ambient temperature -25...+80 C Display Degree of protection IEC 60529 LED green and yellow Housing: IP 30 Connections: IP 20 Norm EN 60 947-5-2 Connection Screw terminals 18 92 22 Made in Germany All specifications are subject to change without notice. (2017

107 522300 EGII-130 Power Supply EG II-130 Series 130 - Relay Output To connect two 2, 3 or 4-wire sensors with NPN or PNP transistor output (not from our series SW-600. When connecting one antivalent sensor (4-wire both outputs, NO and NC, can be connected. When connecting two antivalent sensors only one output of each can be connected. With two output relays (1 x changeover and 1 x normally open Certificate: Operating voltage (U B No-load current (I o Output function Contact rating each relay max. Type 115 / 230 V AC ± 15 % 40...60 Hz Typ. 40 ma 1 x potential-free change-over contact / 1 x potential-free NO 250 V AC / 6 A EGII-130 Art.-No. 522 300 Actuating voltage (U S 24 V DC ± 20 % Actuating current max. (I S Residual ripple acc. to DIN 41 755 max. 2 % Actuating signal 60 ma PNP or NPN Permitted ambient temperature -25...+80 C Display Degree of protection IEC 60529 LED green and yellow Housing: IP 30 Connections: IP 20 Norm EN 60 947-5-2 Connection Screw terminals All specifications are subject to change without notice. (2017 92 22 Made in Germany 19

107 522100 EGI-130-TD Power Supply EG I-130-TD Series 130 - Relay Output With Time Delay To connect one 2, 3 or 4-wire sensor with NPN or PNP transistor output. When connecting an antivalent sensor (4-wire the NO or NC output can be connected. With one output relay (1 x changeover This control unit provides an energising or de-energising delay, which is programmable by a switch: A = energising delay, B = de-energising delay. Certificate: Operating voltage (U B No-load current (I o Output function Contact rating each relay max. Type 115 / 230 V AC ± 15 % 40...60 Hz Typ. 20 ma 1 x potential-free change-over contact 250 V AC / 6 A EGI-130-TD Art.-No. 522 100 Actuating voltage (U S 24 V DC ± 20 % Actuating current max. (I S Residual ripple acc. to DIN 41 755 max. 2 % Actuating signal 60 ma PNP or NPN Permitted ambient temperature -25...+80 C Display Version adjustable for time Degree of protection IEC 60529 LED green and yellow Energising and de-energising delay t 1 = 0,1...5 s/ t 2 = 2...60 s Housing: IP 30 Connections: IP 20 Norm EN 60 947-5-2 Connection Screw terminals 20 92 22 Abfallverzögert/Delay off B A Anzugsverzögert/Delay on N 115V~ 230V~ max. 250 V 6A EGI-130-TD Art. Nr.: 522100 grün/green + 24 V +/- 20 % - gelb/yellow + (BN 4 Imax 60 ma 10 - (BL 5 tmax tmin 11 d1 6 (BK t 12 A1 PNP/NPN 1 2 3 AC +/- 15% 2 60 s 0,1 5s t2 t1 Made in Germany All specifications are subject to change without notice. (2017

107 Power Supply EG I-130-MM Series 130 - Relay Output- MIN / MAX-Control To connect two 2 or 3-wire sensors in NO-function with NPN or PNP transistor output. When connecting antivalent sensors the NO-output can be connected. Integrated MIN / MAX-Control With one output relay (1 x changeover Certificate: Operating voltage (U B No-load current (I o Output function Contact rating each relay max. Type 115 / 230 V AC ± 15 % 40...60 Hz Typ. 20 ma 1 x potential-free change-over contact 250 V AC / 6 A EGI-130-MM Art.-No. 522 200 Actuating voltage (U S 24 V DC ± 20 % Actuating current max. (I S Residual ripple acc. to DIN 41 755 max. 2 % Actuating signal 60 ma PNP or NPN Permitted ambient temperature -25...+80 C Display Version Degree of protection IEC 60529 LED green and yellow Min. / max.-control Housing: IP 30 Connections: IP 20 Norm EN 60 947-5-2 Connection Screw terminals All specifications are subject to change without notice. (2017 92 22 Made in Germany 21

110 6NA 0003 EGIII-130 24/48 VAC 6NA 0002 EGIII-130 115/230 VAC Power Supply EG III - 130 Series 130 - Relay Output To connect three 2, 3 or 4-wire sensors with NPN or PNP transistor output. When connecting an antivalent sensor (4-wire the NO or NC output can be connected With three output relays EGIII-130 24/48 VAC NA 0003 Certificate: Operating voltage (U B No-load current (I o Output function Contact rating each relay max. Type 115 / 230 V AC ± 15 % 40... 60 Hz Typ. 40 ma 3 x potential-free change-over contact 250 V AC / 6 A EGIII-130 Art.-No. NA 0002 Actuating current max. (I S 100 ma Residual ripple acc. to DIN 41 755 max. 2 % Actuating signal PNP or NPN Permitted ambient temperature -25...+70 C Display Degree of protection IEC 60529 LED green and yellow Housing: IP 30 Connections: IP 20 Norm EN 60 947-5-2 Connection Screw terminals 22 75 70 Made in Germany L1 230V L1 115V All specifications are subject to change without notice. (2017

Accessories Pages: Pac-Bus single-element 22-23 Terminal set for pac-bus 22-23 All specifications are subject to change without notice. (2017 23

20,3 14,2 pac-bus System ZONES 0 1 2 20 21 22 Ex i Interfaces Installation in X X pac-bus System Simple and time saving wiring for power supply and common error messaging for groups of N-132/... series. Installation without tools on DIN rails NS35/15 or NS35/7,5. pac-bus single element, raster distance 17,6 mm and terminal set for pac-bus 5 - pole (set begin + end with bridge for error message chain Supply for approx. 40 modules per segment Usable for high and low profile DIN rails (NS35/15 and NS35/7,5 Just snap on DIN rail without tools Elements can be appended at any time Potential free error messaging contact for common error signal Gold plated contacts for highest contact safety Low cost supply via terminals Supply module with integrated replaceable fuses and redundant supply available Installation possible in Zone 2 and Div. 2 N-132... modules LF = Line fault PF = Power supply failure 22,1 36,3 3,81 17,6 24,2 * Contact self closing All specifications are subject to change without notice. (2017 24

Customer proximity guaranteed! pac-bus single element, raster 5-pole, (set begin and end with distance 17,6 mm bridge for error message chain Rechner Sensors has daughter and sister companies in China, Great Britain, Italy, Canada, South Korea and in the U.S.. Furthermore we have representative offices in over 50 countries. For the addresses of our sales partners please visit our website. You will find the addresses under the category contact. Packaging unit 3 pieces 1 set All specifications are subject to change without notice. (2017 Type pac-bus Terminal set for pac-bus Art. No. 190 760 190 761 Certificates BVS 03 E 213 E Explosion protection II 3G EEx na II T4 Installation In Zone 2, Div. 2 and in the safe area Power supply connection Number of contacts 2 2 Nominal voltage (U N 24 V DC 24 V DC Max. voltage 31,2 V 31,2 V Max. current 4 A 4 A Max. through resistance < 5 mω < 5 mω Common error messaging Number of contacts connection 1 + 1 (self closing 1 + 1 (self closing Nominal voltage (U N 24 V DC 24 V DC Max. voltage 31,2 V 31,2 V Max. current 100 ma 100 ma Max. through resistance < 5 mω < 5 mω Ambient conditions Ambient temperature -25...+70 C -25...+70 C (Follow specification of Ex i isolators Storage temperature -40...+80 C -40...+80 C Relative humidity (no condensation 95 % 95 % Vibration (DIN EN 60068-2-6 Frequency / amplitude / speed 2-200 - 2 Hz / 10 mm / 4 g 2-200 - 2 Hz / 10 mm / 4 g Shock (DIN EN 60068-2-7 Acceleration / pulse time 25 g / 6 ms 25 g / 6 ms Free fall (DIN EN 60068-2-32 Level / number 1 m / 50 1 m / 50 Mechanical data Connections Screw terminals, 5-pole, maximum 1,5 mm² or N-132 24 V DC Screw terminals, 5-pole, maximum 1,5 mm² or N-132 24 V DC Weight Approx. 4 g Approx. 4 g Mounting type On DIN-rail according to EN 50022 On DIN-rail according to EN 50022 Mounting position Horizontal or vertical Horizontal or vertical Protection class IP 20 IP 20 Housing material PA 6.6 PA 6.6 Fire protecting class (UL 94 V0 V0 Contact Copper alloy; 0,5 µm goldplated over 2 µm nickel Copper alloy; 0,5 µm goldplated over 2 µm nickel Withdrawed force > 15 N (typical > 40 N > 15 N (typical > 40 N Plug cycles < 50 < 50 Norm EN 60 947-5-2 EN 60 947-5-2 25

TYPE SELECTION IN ARTICLE NUMBER ORDER Art.-No. Description Page 190760 pac-bus 24, 25 190761 Terminal set for pac-bus 24, 25 522000 EGI-130 18 522100 EGI-130-TD 20 522200 EGI-130-MM 21 522300 EGII-130 19 N00012 N-132/1-01 6 N00014 N-132/1-10 7 N00015 N-132/2-01 9 N00017 N-132/2-10 10 N00018 N-132/2-E-10 12 N00020 N-132/1/4-20-IL 13 N00021 N-132/1(2-01 8 N00022 N-132/1-E-10 11 N00023 N-132/2/4-20-IL 14 NA0002 EGIII-130 115 / 230 VAC 22 TYPE SELECTION IN TYPE DESCRIPTION ORDER Description Art.-No. Page EGI-130 522000 18 EGI-130-MM 522200 21 EGI-130-TD 522100 20 EGII-130 522300 19 EGIII-130 115 / 230 VAC NA0002 22 N-132/1-01 N00012 6 N-132/1-10 N00014 7 N-132/1(2-01 N00021 8 N-132/1/4-20-IL N00020 13 N-132/1-E-10 N00022 11 N-132/2-01 N00015 9 N-132/2-10 N00017 10 N-132/2/4-20-IL N00023 14 N-132/2-E-10 N00018 12 pac-bus 190760 24, 25 Terminal set for pac-bus 190761 24, 25 All specifications are subject to change without notice. (2017 26

Customer proximity guaranteed! Rechner Sensors has daughter and sister companies in China, Great Britain, Italy, Canada, South Korea and in the U.S.. Furthermore we have representative offices in over 50 countries. For the addresses of our sales partners please visit our website. You will find the addresses under the category contact. CANADA GREAT BRITAIN ITALY PEOPLE S REPUBLIC OF CHINA Rechner Automation Inc 348 Bronte St. South - Unit 11 Milton, ON L9T 5B6 Tel. 905 636 0866 Fax. 9056360867 contact@rechner.com www.rechner.com Rechner (UK Limited Unit 6, The Old Mill 61 Reading Road Pangbourne, Berks, RG8 7HY Tel. +44 118 976 6450 Fax. +44 118 976 6451 info@rechner-sensors.co.uk www.rechner-sensors.co.uk Rechner Italia SRL Via Isarco 3 39100 Bolzano (BZ Office: Via Guelfa 5 40138 Bologna Tel. +39 051 0015498 Fax. +39 051 0015497 info@rechneritalia.it www.rechneritalia.it RECHNER SENSORS SIP CO.LTD. Building H, No. 58, Yang Dong Road Suzhou Industrial Park Jiangsu Province Tel. +8651267242858 Fax. +8651267242868 assist@rechner-sensor.cn www.rechner-sensor.cn REPUBLIC OF KOREA (SOUTH UNITED STATES OF AMERICA Rechner-Korea Co. Ltd. A-1408 Ho, Keumgang Penterium IT Tower, Hakeuiro 282, Dongan-gu Anyang City, Gyunggi-do, Seoul Rechner Electronics Ind. Inc. 6311 Inducon Corporate Drive, Suite 5 Sanborn, NY. 14132 Tel. +82 31 422 8331 Fax. +82 31 423 83371 sensor@rechner.co.kr www.rechner.co.kr Tel. 800 544 4106 Fax. 9056360867 contact@rechner.com www.rechner.com All specifications are subject to change without notice. (2017 27

INDUSTRIE-ELEKTRONIK GMBH Gaußstraße 8-10 68623 Lampertheim Germany T: +49 6206 5007-0 F:+49 6206 5007-36 F Intl. +49 6206 5007-20 www. rechner-sensors.com E-mail: info@rechner-sensors.de