minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

Similar documents
minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

minimal installation depth: 97 mm without plug-in terminal min-/max-value recording display flashing at threshold undercut/ exceedance

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

installation depth: 90 mm without plug-in terminal 30 additional adjustable setpoints permanent MIN/MAX-value recording volume measuring (totaliser)

installation depth: 90 mm without plug-in terminal display flashing at threshold exceedance / threshold undershooting

DIGITAL PANEL INSTRUMENTS

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

Digital panelmeter with microprocessor based technology 5 digit. 4 free scalable setpoints/hysteresis/delay time (option)

Process displays For standard signals, temperature, resistance measurement

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

48x48. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output

m/min Digital panel meter with 4½-digit PV4, PT4, PF4, PW4 galvanically insulated 8 free scalable setpoints/hysteresis optical setpoint indication

72x36. Digital panel meter with microprocessor based technology 4-digit PVE4, PTE4, PFE4, PFL4. Galvanically insulated

Assembly. Front view. Parametrization interface. Power Bus

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

P5201 Universal Programmable Transmitters with Galvanic Isolation

DIGITAL PANEL INSTRUMENTS

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

SINEAX V 604s Programmable multifunctional transmitter

DIGITAL PANEL METER N24 AND N25 METER SERIES

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

N24, N25 DIGITAL PANEL METER

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

SHIMADEN DIGITAL INDICATORS

Isolators A3/1.

CONTA-ELECTRONICS. Converter Units

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

JUMO di 32 / di 08. Brief description. Block structure

Digital indicator for panel mounting With multi-function input Model DI25

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Temperature transmitter itemp PCP DIN rail TMT 121

Analogue temperature controllers

02/11/2015

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Temperature Transmitters - Head Mounted

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.

Temperature head transmitter itemp PCP TMT 181

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

APPENDIX APPENDIX A 1

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

SHIMADEN DIGITAL INDICATORS

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

High Performance Process & Temperature Controllers

2002-ALM USER MANUAL

DATA SHEET Selectable AC transducer TAS-311DG

Thermocouple - Transducer

4-20mA, 0-10V and general process measuring bargraph displays

Excellent low-cost Process & Temperature Controllers

02/11/2015

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Optical laser distance sensors. Dimensioned drawing

R7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

Description of functions Controller system VR660 / A200R

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication.

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Portable Multi-Channel Recorder Model DAS240-BAT

Temperature Transmitters - DIN Rail Mounted

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

Economical Digital Indicators For Process and Electrical Measurement

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

TxBlock-USB Transmitter

DIGITAL PROGRAM CONTROLLER

Datasheet ACT20M Signal Isolation and Conversion NEW

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Outside Temperature Sensors

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

MODEL: R30US4. Remote I/O R30 Series

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

MODEL: W2TS. Mini-MW Series

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

20 General technical data XI/ON

SINEAX V604s Programmable multifunctional transmitter

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Temperature controller, 4-channel

itemp HART DIN rail TMT112

CompoBus/D-type Digital Controller

Digital Indicator DS 96/48 PK

OPTITEMP TT 20 Technical Datasheet

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SITRANS T measuring instruments for temperature

General Specifications

KS 40-1 burner Universal Burner Controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

CAN-IO Custom IO remote module

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

LED Driver Compact dimming

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

Electronic Thermostat TE-1 Version according to EN

Transcription:

Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 57 mm without plug-in terminal adjustment via factory default or directly on the sensor signal min-/max-value recording 10 adjustable setpoints display flashing at threshold exceedance / undershooting tara-function programming interlock via access code protection class IP65 at the front plug-in terminal accessories: pc-based configuration-kit PM-TOOL with CD & USB adapter for devices without keypad, for a simple adjustment of standard devices on demand: devices for working temperatures of -40 80 C or -25 C 60 C status 06/10/2011 - panelmeter96x24analog_gb.doc page 7 96x24

Digital panel meter Direct current Direct voltage Shunt Potentiometer Resistance Pt100 Pt1000 Thermocouple ORDER NUMBER (without options) Direct current, direct voltage Supply 230 VAC M1-3VR4B.0001.570AD 150,00 Supply 24 VDC M1-3VR4B.0001.770AD 160,00 M 1-3 V R 4 B. 0 0 0 1. 5 7 0 A D M 1-3 V R 4 B. 0 0 0 1. 7 7 0 A D S100 up to 100 VDC, measuring fault 0.5% of final value 45,00 S260 up to 50 VDC, measuring fault 0.5% of final value 15,00 Direct voltage (Shunt) Supply 230 VAC M1-3VR4B.0002.570AD 175,00 Supply 24 VDC M1-3VR4B.0002.770AD 185,00 M 1-3 V R 4 B. 0 0 0 2. 5 7 0 A D M 1-3 V R 4 B. 0 0 0 2. 7 7 0 A D status 06/10/2011 - panelmeter96x24analog_gb.doc page 8

ORDER NUMBER (without options) Potentiometer (1 kω 100 kω) Supply 230 VAC M1-3VR4B.0005.570AD 175,00 Supply 24 VDC M1-3VR4B.0005.770AD 185,00 M 1-3 V R 4 B. 0 0 0 5. 5 7 0 A D M 1-3 V R 4 B. 0 0 0 5. 7 7 0 A D Resistance (1 kω, 10 kω, 100 kω or 1000 kω) Supply 230 VAC 1 kω M1-3VR4B.0806.570AD 175,00 Supply 24 VDC 1 kω M1-3VR4B.0806.770AD 185,00 Supply 230 VAC 10 kω M1-3VR4B.0506.570AD 175,00 Supply 24 VDC 10 kω M1-3VR4B.0506.770AD 185,00 Supply 230 VAC 100 kω M1-3VR4B.0606.570AD 175,00 Supply 24 VDC 100 kω M1-3VR4B.0606.770AD 185,00 Supply 230 VAC 1000 kω M1-3VR4B.0706.570AD 175,00 Supply 24 VDC 1000 kω M1-3VR4B.0706.770AD 185,00 M 1-3 V R 4 B. 0 0 0 6. 5 7 0 A D M 1-3 V R 4 B. 0 0 0 6. 7 7 0 A D status 06/10/2011 - panelmeter96x24analog_gb.doc page 9 96x24

ORDER NUMBER (without options) Pt100 (2-/3-wire) -200 C 850 C / -328 F 1562 F Supply 230 VAC M1-3TR4B.030C.570AD 180,00 Supply 24 VDC M1-3TR4B.030C.770AD 190,00 M 1-3 T R 4 B. 0 3 0 C. 5 7 0 A D M 1-3 T R 4 B. 0 3 0 C. 7 7 0 A D Pt1000 (2-wire) -200 C 850 C/ -328 F 1562 F Supply 230 VAC M1-3TR4B.060C.570AD 180,00 Supply 24 VDC M1-3TR4B.060C.770AD 190,00 M 1-3 T R 4 B. 0 6 0 C. 5 7 0 A D M 1-3 T R 4 B. 0 6 0 C. 7 7 0 A D status 06/10/2011 - panelmeter96x24analog_gb.doc page 10

ORDER NUMBER (without options) Thermocouple Type B, E, J, K, L, N, R, S, T Supply 230 VDC M1-3TR4B.040X.570AD 180,00 Supply 24 VDC M1-3TR4B.040X.770AD 190,00 M 1-3 T R 4 B. 0 4 0 X. 5 7 0 A D M 1-3 T R 4 B. 0 4 0 X. 7 7 0 A D Accessories PC based configuration software PM-Tool for devices without keypad, PM-TOOL-MUSB6 89,00 for a simple adjustment of standard devices, incl. CD & USB-adapter. Programming is made via an interface on the back. Connection examples M1 devices with direct current / direct voltage input: status 06/10/2011 - panelmeter96x24analog_gb.doc page 11 96x24

Technical data Dimension Housing B96 x H24 x D57 mm (including plug-in terminal, D= 74 mm) Panel cut-out 92.0 +0.8 x 22.2 +0.3 mm Fixing screw elements for insulation thickness up to 3 mm Housing material PC Polycarbonat, black Sealing material EPDM, 65 Shore, black Protection class at the front IP65 standard, back side IP00 Weight approx. 50 g Connection plug-in terminal; line cross-section up to 2.5 mm 2 Display Display 4-digit Digit height 14 mm Segment colour Red (standard), optional available in green, blue and orange Display range -1999 to 9999 Setpoints optical display flashing Overflow horizontal bars at the top Underflow horizontal bars at the bottom Display time/ 0.1 to 10.0 seconds M1-1VR4B.0001 Span -12 12 V / -22 24 ma Direct current / Measuring range 0-10 V / 0/4-20 ma Direct voltage Input resistance Ri at ~200 kω / Ri at ~100 Ω Measuring fault 0.1% of measuring range, ± 1 Digit / 0.1% of measuring range, ± 1 Digit approx. 18 Bit at 1s measuring time M1-1VR4B.0002 Span -5 80 mv / -10 180 mv Shunt Measuring range 0 60 mv / 0 150 mv Input resistance Ri at ~12 kω / Ri at ~30 Ω Measuring fault 0.2% of measuring range, ± 1 Digit / 0.2% of measuring range, ± 1 Digit approx. 18 Bit at 1s measuring time M1-1VR4B.0005 Span >1 kω 1000 kω Potentiometer Measuring range 0 100 % Measuring fault 0.2% of measuring range, ± 1 Digit approx. 18 Bit at 1s measuring time M1-1VR4B.0x06 Span 0 1,1 kω, 0 11 kω, 0 110 kω, 0 1100 kω Resistance Measuring range 0 1 kω, 0 10 kω, 0 100 kω, 0 1000 kω Measuring fault 0.5% of measuring range, ± 1 Digit approx. 18 Bit at 1s measuring time M1-1TR4B.030C Span -200 850 C / -328 1562 F Pt100 Measuring fault 0.1% of measuring range, ± 1 Digit approx. 0.1 C or 0.1 F status 06/10/2011 - panelmeter96x24analog_gb.doc page 12

Sealing M1-1TR4B.060C Span -200 850 C / -328 1562 F Pt1000 Measuring fault 0.2% of measuring range, ± 1 Digit approx. 0.1 C or 0.1 F M1-1TR4B.040C Measuring range Type L -200 900 C Thermocouple Type J -210 1200 C Type K -270 1372 C Type B 80 1820 C Type S -50 1768 C Type N -270 1300 C Type E -270 1000 C Type T -270 400 C Type R -50 1768 C Measuring fault 2 K, ± 1 Digit Power pack Memory Characteristic curve fault Reference junction Supply EEPROM Data life 0.1 C <± 1 kω Semiconductor sensor 230 VAC +/- 10 % (typ.3.7 VA; max. 9 VA) 24 VDC +/- 10 %, galvanic insulated (typ. 0.5 VA; max. 1 VA) 100 years Ambient conditions Working temperature 0 to + 60 C Storing temperature -20 to + 80 C Climatic density relative humidity 0-85% on years average without dew CE-sign Conformity to directive 200/108/EG EMV EN 61326 Safety standard according to low voltage directive 2006/95/EG EN 61010; EN 60664-1 Housing: 3,0 24,0 96,0 Gap for physical unit 74,0 Installation depth incl. plug terminal status 06/10/2011 - panelmeter96x24analog_gb.doc page 13 96x24

Ordering code M1 - Digital display standard M 1-3 V R 4 B. 0 0 0 1. 7 7 0 A D Basic type M-Line Dimension D physical unit (free choice) Installation depth 74 mm 1 Version with plug-in terminal A A Housing size Setpoints 96 x 24 x 57 mm 3 0 no setpoints without plug-in terminal Protection class Display type 1 without keypad, operation on back Temperature T 7 IP65 / plug-in terminal V, A, Ohm V Supply voltage Display colours 4 115 VAC plus 10,25 Blue B 5 230 VAC Green G 7 24 VDC galv. insulated Red R Orange Y 1 Direct current, direct voltage Number of digits 2 Shunt 4-digit 4 5 Potentiometer 6 Resistance Digit height C Pt100 / Pt1000 14 mm B X Thermocouple Type B, E, J, K, L, N, R, S,T Interface without 0 Analog output 0 without Temperature devices 3 Pt100 / 2-3-wire 4 Thermocouple 6 Pt1000 / 2-wire Resistance 8 1 kω 5 10 kω 6 100 kω 7 1000 kω Sensor supply 0 without status 06/10/2011 - panelmeter96x24analog_gb.doc page 14

Blind covers with fastening clamps GH022-07 7,90 status 06/10/2011 - panelmeter96x24analog_gb.doc page 15 96x24

status 06/10/2011 - panelmeter96x24analog_gb.doc page 16