How to Measure LDO PSRR

Similar documents
Power Supply Rejection Ratio Measurement

Signal Injectors. Documentation. Version 1.00, October, Picotest Corp. All Rights Reserved.

Power Supply Rejection Ratio Measurement

Lab 9 Frequency Domain

Power Supply Rejection Ratio Measurement

Integrators, differentiators, and simple filters

Week 8 AM Modulation and the AM Receiver

PHYSICS 330 LAB Operational Amplifier Frequency Response

High Current Amplifier

EE 3302 LAB 1 EQIUPMENT ORIENTATION

Making Invasive and Non-Invasive Stability Measurements

Power Supply Rejection Ratio Measurement

Welcome to your second Electronics Laboratory Session. In this session you will learn about how to use resistors, capacitors and inductors to make

MEASURING HUM MODULATION USING MATRIX MODEL HD-500 HUM DEMODULATOR

Warning: Power amplifier contain high voltages of several hundred volts. Setup errors can easily damage your health or your equipment.

EE4902 C Lab 7

Low Value Impedance Measurement using the Voltage / Current Method

An LDO Primer. Part III: A Review on PSRR and Output Noise

Low_Pass_Filter_1st_Order -- Overview

Exercise 1: AC Waveform Generator Familiarization

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

DC Biased Impedance Measurement

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

Lab 2: Linear and Nonlinear Circuit Elements and Networks

Op-Amp Simulation Part II

Tektronix Courseware. Academic Labs. Sample Labs from Popular Electrical and Electronics Engineering Curriculum

Transmit filter designs for ADSL modems

Laboratory 3 (drawn from lab text by Alciatore)

CHAPTER 6. Motor Driver

New Technique Accurately Measures Low-Frequency Distortion To <-130 dbc Levels by Xavier Ramus, Applications Engineer, Texas Instruments Incorporated

Original Input Stage frequency response measurement verification

ECE4902 C Lab 7

Measuring LDOs requires more bandwidth than you think

1. An engineer measures the (step response) rise time of an amplifier as. Estimate the 3-dB bandwidth of the amplifier. (2 points)

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 781 HIGH EFFICIENCY SYNCHRONOUS NONISOLATED FLYBACK

EK307 Passive Filters and Steady State Frequency Response

Lab Reference Manual. ECEN 326 Electronic Circuits. Texas A&M University Department of Electrical and Computer Engineering

Experiment 8 Frequency Response

When you have completed this exercise, you will be able to determine the frequency response of an

Pre-Lab. Introduction

ME 365 EXPERIMENT 7 SIGNAL CONDITIONING AND LOADING

Power Supply Considerations for DDX Amplifiers

Keywords: linear regulators, LDO, transient, input protection, PSRR, power supply noise

High Common-Mode Rejection. Differential Line Receiver SSM2141 REV. B FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

Sallen-Key_High_Pass_Filter -- Overview

Invasive and Non-Invasive Stability Measurements

Op-Amp Noise Test Results. David Hoyland 5/25/2016

EE 2274 RC and Op Amp Circuit Completed Prior to Coming to Lab. Prelab Part I: RC Circuit

The above figure represents a two stage circuit. Recall, the transfer function relates. Vout

ActiveLowPassFilter -- Overview

Electronic Circuits. Laboratory 1 - Solution

UNIVERSITY OF PENNSYLVANIA EE 206

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Battery Impedance Measurement

P08050 Testing Strategy Document

Measuring Power Line Impedance

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Selected Filter Circuits Dr. Lynn Fuller

EK307 Active Filters and Steady State Frequency Response

Measure Low Value Impedance Current Shunt Impedance

Equivalent Circuit Determination of Quartz Crystals

When you have completed this exercise, you will be able to relate the gain and bandwidth of an op amp

Probe Considerations for Low Voltage Measurements such as Ripple

CRO AIM:- To study the use of Cathode Ray Oscilloscope (CRO).

Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

Homework Assignment 12

Electronics I. laboratory measurement guide

AC Measurements with the Agilent 54622D Oscilloscope

DEPARTMENT OF INFORMATION ENGINEERING. Test No. 1. Introduction to Scope Measurements. 1. Correction. Term Correction. Term...

LAB I. INTRODUCTION TO LAB EQUIPMENT

Homework Assignment 06

1.2W Audio Power Amplifier with Active-low Standby Mode

Property of Ramsey Electronics, Inc. Do not reproduce or distribute.

MODEL 5002 PHASE VERIFICATION BRIDGE SET

UNISONIC TECHNOLOGIES CO., LTD KA8602

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

IS31AP4066D DUAL 1.3W STEREO AUDIO AMPLIFIER. January 2014 KEY SPECIFICATIONS

MEASURING PSRR AND PSR+N ON THE APx525

DC/DC Converter Stability Measurement

Low Cost, General Purpose High Speed JFET Amplifier AD825

Figure 1 Typical Application Circuit

Ensuring Clean Power for RF and Digital Applications

DC/DC Converter Stability Measurement

Documentation. Voltage Regulator Test Standard. Test Platform for Voltage Regulator and LDO Testing

Fig. 1. NI Elvis System

Switch Mode Power Supply Measurements

Documentation. Voltage Regulator Test Standard. Test Platform for Voltage Regulator and LDO Testing

Core Technology Group Application Note 6 AN-6

ECE 203 LAB 2 PRACTICAL FILTER DESIGN & IMPLEMENTATION

Butterworth Active Bandpass Filter using Sallen-Key Topology

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

Electronics Test and Development Centre, STQC Directorate, Agriculture College Campus, Shivajinagar, Pune, Maharashtra

DIY Function Generator XR2206

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

ACP1216. Low Dropout Positive Voltage Regulator GENERAL DESCRIPTION FEATURES APPLICATION CIRCUIT APPLICATION PIN CONFIGURATION ACP1216

SGM W Fully Differential Audio Power Amplifier with Selectable Shutdown

ECE Electronics Circuits and Electronics Devices Laboratory. Gregg Chapman

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

Transcription:

How to Measure LDO PSRR Measure LDO PSRR with Network Analyzer Power supply rejection ratio (PSRR) or some time called power supply ripple rejection measurements are often difficult to measure, especially when the device under test (DUT) is heavily loaded. Typically regulator PSRR is measured with a network analyzer. The network analyzer output signal is AC-coupled into LDO (low dropout) voltage input (Figure 1). The network analyzer generates a sinewave ridding on top of the DC voltage. The LDO input DC voltage is provided by VCC through a small resistor (1 to 10 ohm). The network analyzer is then measure the sinewave amplitude at the LDO input and output using Input-A and Input-B. The ratio of the sinewave at LDO output and input is PSRR. This method works well if the LDO output is no load or very light load. At heavy load there will be too much voltage drop across the series resistor. Because most network analyzer source output is 50 ohm, it cannot effectively drive the LDO at heavy load (i.e. 1A load). For that reason, regulator PSRR testing often is done at no load or light load. LDO PSRR tends to decrease at heavier load and generally worst at maximum specified load. Measuring power supply rejection at no load is not representative LDO PSRR. Figure 1. Conventional LDO PSRR test setup is limited to no load or light load. To test LDO PSRR at heavy load, a high current driver is needed. The TS200 Modulated Power Supply is extremely useful for power supply rejection measurement for such devices as LDOs and power amplifiers. Figure 2 shows how to measure PSRR. PSRR measurement technique involves a network analyzer, the TS200 power amplifier, and the device under test (DUT).

( a ) ( b) Figure 2. LDO PSRR measurement setup. (a) calibration the setup, (b) Measuring LDO PSRR. Figure 2 shows the LDO power supply rejection ratio measurement setup. Using a network analyzer, the source is connected to the TS200 modulation input. The TS200 DC and AC output is connected to the LDO supply input. It is recommended to reduce the LDO input capacitance to minimum. Since the TS200 can drive heavy load, thus the LDO output can be loaded with the desired loading resistor (i.e. maximum specified load). Set the TS200 modulation input to AC-coupled. Adjust the DC Offset knob until the output DC voltage reaches the desired voltage (i.e. 3.3V). Typically for PSRR testing, the supply ripple amplitude is 200mVpp. If you are using the A-version, set the network analyzer output to 200mV. If you are using the B-version and consider the modulation gain is 20dB, set the network analyzer output amplitude to 20mVpp. First the network analyzer and the TS200 need to be calibrated. Figure 2a shows the calibration setup. The network analyzer input-a and input-b are connected together at one point on the DUT board near the LDO supply input. Set the network analyzer to calibration mode and sweep over the

frequency range (i.e. 100Hz to 100kHz) to be measured. Save the calibration data for later use. Refer the network analyzer manual for detailed calibration setup. After calibration, LDO PSRR measurement setup is shown Figure 2b. The network analyzer input-b is moved to the LDO output near the capacitor while keeping input-a at the LDO input. Again sweep the network analyzer over the desired frequency range. You may refer to the network analyzer manual for details. After subtracting the calibration data, PSRR data is plotted. Figure 3 shows an example of PSRR plot. Table 1 shows a list of network analyzers can be use with TS200. Figure 3. Example of LDO PSRR vs. frequency at various load current. Table 1. List of network analyzers Manufacturer Model AP Instruments Model 300 Omicron Bode 100 Agilent 4395A Audio Precision SYS2722

LDO PSRR Measurement with Oscilloscope If a network analyzer is not available, an alternatively method for regulator PSRR measurement is done by using an oscilloscope. This method requires manually taking data over frequency. Because oscilloscope has higher noise floor and lower sensitivity, it is difficult to measure PSRR better than 60dB. Power supply ripple rejection test using oscilloscope is acceptable for spot-checking if network analyzer is not available. Place the oscilloscope probes as shown in Figure 4. CH1 probe is connected to LDO supply input near the capacitor and CH2 probe is connected to LDO output near the capacitor. 1x probe is recommended to reduce the effect of oscilloscope noise floor. Figure 4. LDO PSRR testing using an oscilloscope if network analyzer is not available. Connect a function generator to the TS200 Modulation input. Set the function generator output to 200mVpp sinewave or 20mV if B-version is used. Set the frequency to the frequency of interest (i.e. 1kHz). Then set the TS200 modulation to AC-couple. Adjust the DC Offset knob until the TS200 output voltage reaches the desired voltage (i.e. 3.3V). Using the oscilloscope, you can measure the amplitude voltage at CH1 and CH2. Divide CH2 by CH1 is the PSRR. You can use the below equation for PSRR calculation in db. PSRR = 20log(CH2/CH1) If PSRR is better than 40dB, it is recommended to increase the TS200 output ripple voltage 500mVpp due to oscilloscope has lower sensitivity than network analyzer.

Accel Instrument Email: info@accelinstruments.com Wed site: