TEMPERATURE CONTROLLER RE21 TYPE

Similar documents
TEMPERATURE CONTROLLER. MOUNTED ON A 35 mm RAIL RE60 TYPE USER S MANUAL

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

TEMPERATURE CONTROLLER RE55 TYPE USER S MANUAL

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

DIGITAL PANEL METER N24 AND N25 METER SERIES

SEPARATOR P20G TYPE USER S MANUAL

PROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE

THREE-PHASE POWER CONTROLLER RP3 Type

N24, N25 DIGITAL PANEL METER

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D

TEMPERATURE CONTROLLER 48 x 48 mm RE70 TYPE USER S MANUAL

POWER CONTROLLER RP1 type

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

High power radio transmission module MR03 type

4-CHANNEL MODULE OF ANALOG INPUTS SM2 TYPE

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

Digital indicator for panel mounting With multi-function input Model DI25

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

POWER NETWORK PARAMETER METER N13 SERVICE MANUAL

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

TRANSDUCER OF NETWORK PARAMETERS P43 TYPE

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Temperature transmitter itemp PCP DIN rail TMT 121

Installation and Operational Instructions for ROBA -switch Type 017._00.2

a * example of application MeaSUreMent and ViSUalization of power network parameters Ethernet TCP IP RS-485 USB HOST /SD CARD

Precipitation Monitor ,

N E W functions! Modbus. Wireless transmission - SM ma TCP IP ma. NA5 meter with bargraph. k *

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Paperless Recorder PR20

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

UNIVERSAL CONTROLLER RE62

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

USER S MANUAL. Rail-mounted temperature transmitter ATL

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

N30P DIGITAL PANEL METER

Thermocouple - Transducer

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

RMO500 M I C R O O H M M E T E R

itemp HART DIN rail TMT112

Precipition Sensor with analogue Intensity Output ,

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

Installation and Operating Instructions for Phase Demodulator Type _.2

AMM-1022 Digital Multimeter USER`S MANUAL

Temperature head transmitter itemp PCP TMT 181

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

itemp PA TMT184 Technical information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

RE92. CHECKMATE. Dual loop controller for industry purpose.

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

OPTITEMP TT 20 Technical Datasheet

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

ND40 V V. Ethernet www/ ftp / smtp. Ethernet TCP IP RS-485 USB HOST /SD CARD.

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Analogue temperature controllers

0 2 1 â Ó. itemp HART TMT182. Technical Information

External brake resistor AX2090-BW5x

B850 Boiler House Energy Monitor

Outside Temperature Sensors

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

DM-45 Digital Multimeter

Electromotoric actuators for stroke valves

Three-Phase Transformer Demagnetizer DEM60

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

1800 Series Attachable Loop-Powered Digital Indicators Operating Manual

Winding Ohmmeter RMO-TW

RMA42. Technical Information

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Power supply CP-E 24/2.5

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

0 2 1 â Ó. itemp HART TMT182. Technical Information

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Power supply CP-E 24/20.0

High precision measurement system for current and voltage IHC-A/B-RM01/03

SCC-FV01 Frequency Input Module

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Power supply CP-D 24/4.2 Primary switch mode power supply

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Impulse system MPT 700. Manual Edition GB

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

Operating Manual MU2000K

Type CP-S, CP-C & CP-A Switch mode

Magnetic Inductive Flow Sensor induq

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

HART Compatible Intelligent 2-wire DIN Rail Transmitters

Operating Instructions

OPTITEMP TT 10 C/R Technical Datasheet

Transcription:

TEMPERATURE CONTROLLER RE21 TYPE USER S MANUAL 1

2

Contents 1. Application... 5 2. Controller set... 5 3. Preparation of the controller to work... 6 3.1. Safety... 6 3.2. Controller installation... 9 3.3. Electrical connection... 10 3.4. Installation recommendations... 11 4. Starting to work... 12 5. Programming of controller parameters... 13 5.1. Scheme of the controller menu... 13 5.2. Change of the setting... 15 5.3. List of parameters... 16 6. Control... 17 6.1. ON-OFF control... 17 6.2. PID control... 17 6.2.1. Choice of PID settings by the method of object identifying... 18 6.2.2. Choice of PID settings be the oscillation method... 19 6.2.3. Correction of PID settings... 19 7. Error signalling... 20 8. Technical data... 21 9. Execution and ordering codes... 23 10. Maintenance and guarantee... 24 3

4

1. APPLICATION The RE21 controller is destined to control temperature in furnaces, dryers, injection moulding machines and others. It co-operates directly with temperature sensors of resistance thermometer or thermocouple types. For thermocouples the temperature of cold ends is automatically compensated. The controller has a relay output with a shorted-opened configuration enabling the direct control of not big power objects. 2. CONTROLLER SET controller - 1 pc plug - 1 pc plug - 1 pc holder to fix in the panel - 2 pcs user s manual - 1pc guarantee card - 1pc quick start card - 1pc When unpacking the instrument, please check whether the type and execution code on the data plate correspond to the order. 5

3. PREPARATION OF THE CONTROLLER TO WORK 3.1. Safety The RE21 controller fulfils requirements concerning the electrical safety of measuring instruments in automation acc. to EN 61010-1, and requirements concerning immunity against electromagnetic interference acc. to EN 61000-6-2 and emission of electromagnetic interference occurring in industrial environment acc. to EN 61000-6-4 BASIC REQUIREMENTS, SAFETY INFORMATION Symbols located in this service manual mean: WARNING!? Warning of potential, hazardous situations. Especially important. One must acquaint with this before connecting the instrument. The non-observance of notices marked by these symbols can occasion severe injuries of the personnel and the damage of the instrument. CAUTION! Designates a general useful note. If you observe it, handling of the meter is made easier. One must take note of this, when the instrument is working inconsistently to the expectations. Possible consequences if disregarded! In the security scope the meter meets the requirements of the EEC Low-Voltage Directive (EN 61010-1 issued by CENELEC ). 6

Remarks concerning the operator safety: 1. General - The controller is destined to be mounted on a panel. - Non-authorized removal of the required housing, inappropriate use, incorrect installation or operation creates the risk of injury to personnel or damage to equipment. For more detailed information please study the User s Manual. - All operations concerning transport, installation, and commissioning as well as maintenance must be carried out by qualified, skilled personnel and national regulations for the prevention of accidents must be observed. - According to this basic safety information, qualified, skilled personnel are persons who are familiar with the installation, assembly, commissioning, and operation of the product and who have qualifications necessary for their occupation. 2. Transport, storage Please observe the notes on transport, storage and appropriat e handling. Observe the climatic conditions given in Technical Data. 3. Installation - The controller must be installed according to the regulation and instructions given in this User s Manual. - Ensure proper handling and avoid mechanical stress. - Do not bend any components and do not change any insulation distances. - Do not touch any electronic components and contacts. - Controllers may contain electrostatically sensitive components, which can easily be damaged by inappropriate handling. - Do not damage or destroy any electrical components since this might endanger your health! 7

4. Electrical connection - Before switching the controller on, one must check the correctness of connection to the network. - In case of the protection terminal connection with a separate lead one must remember to connect it before the connection of the controller to the mains. - When working on live controllers, the applicable national regulations for the prevention of accidents must be observed. - The electrical installation must be carried out according to the appropriate regulations (cable cross-sections, fuses, PE connection). Additional information can be obtained from the user s manual. - The documentation contains information about installation in compliance with EMC (shielding, grounding, filters and cables). These notes must be observed for all CE-marked products. - The manufacturer of the measuring system or installed devices is responsible for the compliance with the required limit values demanded by the EMC legislation. 5. Operation - Measuring systems including RE21 controllers, must be equipped with protection devices according to the corresponding standard and regulations for prevention of accidents. - After the controller has been disconnected from the supply voltage, live components and power connections must not be touched immediately because capacitors can be charged. - The housing must be closed during operation. 6. Maintenance and servicing. - Please observe the manufacturer s documentation. - Read all product-specific safety and application notes in this User s Manual. - Before taking the meter housing out, one must turn the suppl off. - The removal of the instrument housing during the guarantee contract period may cause its cancellation. 8

3.2. Controller installation The controller is fixed to the panel by two screw holders included in the standard accessory set, acc. to the fig. 1. The panel hole should be 45 +0.6 x 45 +0.6 mm. The thickness of the material which the panel is made of, cannot exceed 15 mm. Fig.1. Controller fixing. 9

Fig.2. Overall dimensions of the controller. 3.3. Electrical connections Electrical connections should be executed in compliance with fig. 3 and fig. 4.. Make electrical connections to the terminal strips and next, force in the strips into controller sockets. Input signals Output Supply Fig. 3. Description of the controller terminal strips. 10

Jointer Pt100 resistance thermometer in 2-wire system Pt100 resistance thermometer in 3-wire system thermocouple Fig.4. Connection of input signals. Supply Output - relay Output - binary voltage for SSR control Fig.5. Connection of the main and load circuits. 3.4. Installation recommendations To obtain a full immunity of the controller against electromagnetic interference in an unknown environment interference level it is recommended to observe following principles: - do not supply the controller from the network near devices generating high pulse interference and do not use common earthing circuits with them. - apply network filters, - apply metallic shields in the shape of tubes or braided screens to conduct supplying wires, - wires supplying the measuring signal should be twisted in pairs, and for resistance thermometers in a 3-wire connection, twisted from wires with the same length, cross-section and resistance, and led in a shield as above, 11

- all shields should be one-side earthed, and led the nearest possible to the controller, - apply the general principle that wires leading different signals should be led the farthest possible between them (not less than 30 cm), and the crossing executed of these groups of wires must be made at right angle. 4. STARTING TO WORK After the correct installation and supply connection, the controller carries out the display test and displays the type of controller re21, the program version and next, the measured value. A character message can appear on the display informing about abnormalities (table 2). The ON-OFF control algorythm with hysteresis = 2 C is set by the manufacturer. Change of the set value The set value is displayed after pressing the or key. The way to change the set value is shown on the fig.6.the return to display the measured value follows after pressing the key or after 30 seconds from the last pressure of the or key. Measured value Set value Change of the set value Fig.6. Change of the set value. 12

5. PROGRAMMING OF CONTROLLER PARAMETERS 5.1. Scheme of the controller menu The controller menu scheme is presented on the fig.7. After pressing and holding during at least 2 seconds the key, it is possible to program parameters. Transition between parameters is carried on by means of and keys. Some parameters can be invisible - this depends on the control algorythm selection. The return to the normal working mode follows after the simultaneous pressure of and keys or automatically after the laps of 30 seconds since the last key pressure. 13

14 Fig.7. Servicing menu of the controller.

5.2. Change of setting The parameter setting change begins after the pressure of the key. The selection of the setting is carried out by and keys and accepted by the key. The change cancellation is carried out by a simultaneous pressure of and keys or automatically after 30 sec from the last key pressure. The way of the setting change is shown on the fig. 8. Start of changes Resignation of changes Acceptation of changes Decrease of value Increase of value Start of changes Resignation of changes Acceptation of changes Previous parameter Next parameter Fig.8. Change of settings for numerical and textual paramete. 15

5.3. List of parameters The list of controller parameters is presented in the table 1. List of configuration parameters Table 1 Parameter Parameter description Manufacturer Range of parameter symbol setting change Hy Hysteresis 1) 2.0 0.2...99.9 C pb Proportional band 2) 30.0 0.1...999.9 C ti Integration time-constant 3) 300 1...9999 s td Differentiation time-constant 4) 60 1...9999 s to Pulse period 2) 20.0 0.5...99.9 s out Output configuration inu dir: direct control (cooling) inu: reverse control (heating) alg Control algorytm onof onof: control algorythm ON-OFF p: control algorythm P pd: control algorythm PD pid: control algorythm PID reso Position of the decimal point 1-dp 0_dp: without decimal point 1_dp: 1 decimal point 1) The parameter is visible only for ON-OFF algorythm. 2) The parameter is visible only for P, PD or PID algorythm. 3) The parameter is visible only for the PID algorythm. 4) The parameter is only visible for PD or PID algorythm. 16

6. CONTROL 6.1. ON-OFF control When a high accuracy of the temperature control is not required, especially with a great time-constant and a small delay, one can use the ON-OFF control with hysteresis. Advantages of this way of control is simplicity and reliability. However, the disadvantage is the occurrence of oscillations, even at small hysteresis values. Fig.9. Way of the output action of heating type for ON-OFF control. 6.2. PID control When we want to obtain a better temperature control accuracy, one must take advantages of the PID algorythm. The adjustment of the controller to the object relies on the value settlement of the integrating element, differentiating element and the output pulse period. 17

6.2.1. Choice of the PID settings by the method of the object identifying One must read out the delay time of the To object from the object characteristic presenting the controlled quantity in the function of time and the maximal accretion speed of the temperature from the dependence: V max = DPV max Dt Calculate PID settings acc. to the given formulas: Pb = 1.1. V. max T 0 - proportional band ti = 2.4. T 0 - integration time-constant td = 0.4. T 0 - differentiation time-constant 18

6.2.2. Choice of PID settings by the oscillation method Set the ON-OFF control with the minimal hysteresis. Set the set value on the normal work level (or on lower level, if over-regulations could cause damages) and normal load conditions. Fig.10. Choice of settings by the oscillation method Calculate controller settings acc. to the given formulas: Pb = P ti = T td = 0.25. T 6.2.3. Correction of PID settings It is recommended to match the parameters, changing the value into a twice higher or twice lower. During changes, one must be guided by following principles: a) Free answer of the jump: - decrease the proportional band, - decrease integration and differentiation times. 19

b) Over-regulations: - increase the proportional band, - increase the differentiation time. c) Oscillations: - increase the proportional band, - increase the integration time, - decrease the differentiation time. d) Instability: - increase the integration time. 7. ERROR SIGNALLING Character messages signaling the incorrect controller operation. Error code (upper display) lerr Cause Exceeding of the measuring range downward or lack of thermistor. Procedure Table 2 Check if the chosen type of sensor is conform to the switched on. Check if values of input signals are contained in the appropriate range - if yes, check if a short-circuit does not occur in the resistance thermometer or if the thermocouple has not been inversely switched on. Herr Exceeding of the measuring range upward or break in the sensor circuit. Check if the chosen type of sensor is conform with the switched on. Check if values of input signals are contained in the appropriate range - if yes, check if there is no break in the sensor circuit. erad Input discalibrated. Switch on again the controller supply and if this cannot help, contact the nearest authorized workshop. 20

8. TECHNICAL DATA Input signal acc. to the table 3 Input signals and measuring ranges for inputs Sensor/input type Marking Range Basic error [ C] [ C] Table 3 Pt100 Pt100-50...100 0.8 acc. to EN 60751+A2 Pt100 Pt100 0...250 1.3 Pt100 Pt100 0..600 3.0 Fe-CuNi J 0...250 3.0 acc. to EN 60584-1 Fe-CuNi J 0...600 4.0 Fe-CuNi J 0...900 5.0 NiCr-NiAl K 0...600 4.0 acc. to EN 60584-1 NiCr-NiAl K 0...900 5.0 NiCr-NiAl K 0...1300 6.0 PtRh10-Pt S 0...1600 7.0 acc. to EN 60584-1 Measurement time 0.5 s Error detection in the measuring circuit: - thermocouple, Pt100 exceeding of the measuring range Kind of output: - relay switching contact maximal load capacity: voltage: 250 V a.c.,150 V d.c. current: 5 A, 250 V a.c.,5 A, 30 V d.c. resistance load: 1250 VA, 150 W - binary voltage (without insulation from the sensor side) Way of output action: - reverse for heating - direct for cooling voltage 6 V +0.3 V, resistance limiting the current: 100 W 21

Signalling of: - active output - set value display Rated service conditions: - supply voltage 230 V a.c. ±10% 110 V a.c. ±10% 24 V a.c. ±10% - supply voltage frequency 50/60 Hz - ambient temperature 0...23...50 C - storage temperature -20...+70 C - relative humidity < 85 % (inadmissible condensation) - external magnetic field < 400 A/m - preheating time 30 min - work position any Power consumption < 3 VA Weight < 0.25 kg IP protection ensured through the housing acc. EN 60529 - from the frontal side IP40 - from terminals IP20 Additional errors in rated working conditions caused by: - ambient temperature changes 100% of the basic error /10 K. Security requirements acc to EN 61010-1 - installation category - III, - pollution degree - 2, - maximal phase-to-earth work voltage: - for the supply circuit, outputs - 300 V - for input circuits - 50 V Electromagnetic compatibility - immunity acc. EN 61000-6-2 - emission acc. EN 61000-6-4 22

9. ORDERING CODES The coding way is given in the table 4 Table 4 Temperature controller RE21 - XX X XX X Input resist. thermometer Pt100 (-50...100 O C)... 01 resist. thermometer Pt100 (0...250 O C)... 02 resist. thermometer Pt100 (0...600 O C)... 03 thermocouple Fe-CuNi (0...250 O C)... 04 thermocouple Fe-CuNi (0...600 O C)... 05 thermocouple Fe-CuNi (0...900 O C)... 06 thermocouple NiCr-NiAl (0...600 O C)... 07 thermocouple NiCr-NiAl (0...900 O C)... 08 thermocouple NiCr-NiAl (0...1300 O C)... 09 thermocouple PtRh10-Pt (0...1600 O C)... 10 as ordered*... X Supply voltage: 230 V 50/60 Hz... 1 110 V 50/60 Hz... 2 24 V 50/60 Hz... 3 as ordered*... X Output: relay... 00 binary 0/6 V for SSR control... 01 without output... 09 as ordered*... XX Extra acceptance tests: without extra quality requirements... 0 with an extra quality inspection certificate... 1 acc. agreement with the manufacturer**... X * The code numbering is defined by the manufacturer ** After agreement with the manufacturer Example of ordering: Code RE21-03 - 2-00 - 0 means: 03 - Pt100 resistance thermometer as the input 2 - supply = 110 V, 50/60 Hz 00 - relay output 0 - without extra quality requirements 23

10. MAINTENANCE AND WARRANTY The RE21 controller does not require any periodical maintenance. In case of some incorrect operations: 1. After the dispatch date and within the period stated in the warranty card One should return the instrument to the Manufacturer s Quality Inspection Dept. If the instrument has been used in compliance with the instructions,the Manufacturer guaranties to repair it free of charge. The disassembling of the housing causes the cancellation of the granted warranty. 2. After the warranty period One should send the instrument to repair it in a authorized service workshop. Spare parts are available for the period of five years from the date of purchase. The Manufacturer reserves the right to make changes in design and specifications of any products as engineering advances or necessity requires. 24

25

LUMEL S.A.RE21/January 2006 Lubuskie Zak³ady Aparatów Elektrycznych - LUMEL S.A. ul. Sulechowska 1, 65-022 Zielona Góra, Poland Tel.: (48-68) 32 95 100 (exchange) Fax: (48-68) 32 95 101 www.lumel.com.pl e-mail:lumel@lumel.com.pl Export Department: Tel.: (48-68) 329 53 02 or (48-68) 329 53 04 Fax: (48-68) 325 40 91 e-mail: export@lumel.com.pl 26