Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Similar documents
SLAMf Series. Data Sheet. Elastomer Sealed, Digital, Thermal Mass Flow Meters and Controllers. Overview. Product Description.

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Brooks SLA5850, SLA5851, SLA5853 Mass Flow Controllers Models and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

GF40/GF80. Data Sheet. Elastomer and Metal Seal Digital Mass Flow Controllers and Meters. Overview. Product Description.

Brooks Digital Remote Transducer Pressure Controller/Flowmeter Model SLA5840

ED701 General Industry Pressure Transmitter

Catalog. Aera Transformer Digital Mass Flow Products Transform your process with greater flexibility and lower cost of ownership

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

IP26 Series Current to Pneumatic Converter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Mass and Volume Flow Transmitter

Gas Mass Flow Control Products

Using the AcuDew Moisture Transmitter

Mass Flow and Density Transmitter with FOUNDATION fieldbus

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

SATRON VB Pressure Transmitter

PAD - Heavy Duty Differential Pressure Trasmitter

OPTIMASS 1000 Technical Datasheet

RCM DIRECT READING FLOWMETER

Micro Motion Model 2400S Transmitters with MVD Technology

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

KFS. Flap-type flow meter. Design and range of application

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Micro Motion LF-Series Low Flow Flowmeter

Micro Motion LF-Series Low Flow Sensor and Transmitter

Compact Liquid Flow Controllers for UHP Applications

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Compact Orifice Flow Meter

Flow Measurement SITRANS F M

General Specifications

Submersible pressure sensor For oils and fuels Model LF-1

Rosemount 3101, 3102, and 3105

Non-Submersible Industrial Pressure Transducer

Fisher 646 Electro Pneumatic Transducer

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Electronic Temperature Transmitters

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Mass Flow Measurement and Control System

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For superior applications Model LF-1

Data Sheet SS/265VS-EN_1

TRONIC Digest. TRONIC Digest Pressure and Temperature Transmitters

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

USER MANUAL MODEL CSLFC ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL CLARK SONIC MODEL CSLFC

OPTIFLUX 5000 Technical Datasheet

Accutech DP20. Wireless differential pressure field unit

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

DATASHEET F090 - GENERAL PURPOSE INDICATOR

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

OPTIWAVE 1010 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

Series Smart Pressure Transmitter

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

Process display RIA 261

Micro Motion Model RFT9739 Flow and Density Transmitter

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Accutech GP10. Wireless gauge pressure field unit

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Relative and absolute pressure transmitter type 528

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

M5800 Pressure Transducer with Rotatable Display

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

VELTRON II Microprocessor Based Pressure & Flow Smart

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Field IT 2600T Series Pressure Transmitters

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Loop Powered Indicator

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

The Rosemount 848T Wireless Temperature Transmitter

New! Micro Motion CNG050 Compressed Natural Gas Mass Flowmeter with MVD Technology. Product Data Sheet PS EU February 2001

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch

Digital flow transmitter for continuous flow measurement

Technical Information Cubemass

Field indicator for current loops with HART communication Models DIH50, DIH52

UTM10 Series Ultrasonic Transit-time Flowmeters

Fisher 646 Electro-Pneumatic Transducers

TIDALFLUX 2300 F Technical Datasheet

General Specifications

SITRANS LR 300: High Performance Radar for Level Measurement

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

Transcription:

Data Sheet Brooks Industrial Brooks Digital Series Digital MFC's and MFM's Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters General Features: Wide FS flow range for measurement and control of gases from 3 ccm to 2500 lpm, (N 2 ) Accuracy: + 1.0% of rate up to 1100 lpm; 1% FS including linearity above 1100 lpm. Industry leading sensor stability. Long term drift performance of < 0.2% per year. Increased system throughput by reducing maintenance and eliminating periodic recipe adjustment. Storage of up to 10 selectable calibration curves. Spares inventories are reduced by limiting the number of individual MFC/M's required, lowering inventory holding costs. NEMA 4X and IP66 weatherproof protection for 'Hosedown' applications such as: Food, Beverage, Pharmaceutical and Biotech. Control Response: Settling Time of less than 1 second. (better on request). Soft start can be used to tailor MFC performance to process requirements. Proprietary Adaptive Valve Control algorithm is available which assures that unexpected variations in process pressure do not cause flow to deviate from setpoint. Model SLAMf50F Digital I/O FOUNDATION Fieldbus MFC Model SLAMf50S Analog I/O MFC with RS-485 Model SLAMf53D Digital I/O DeviceNet TM MFC Analog I/O Option: Cable Gland Opening (PG-11) Conduit Opening 1/2" NPTF or M20 x 1.5 0(1)-5 Volt or 0(4)-20 ma setpoint and flow signals Single sided 24 Volt DC power supply (13.5-27 volts DC range). Separate Valve-Override signal Precision 5 Volt Reference Output signal Compatible with Brooks' Model 0150 series secondary electronics TTL (open collector) Alarm Output signal Digital Communication Options: DeviceNet TM, ODVA TM certified FOUNDATION TM Fieldbus, H1 Certified HART based RS-485 multidrop DESCRIPTION Brooks Instrument s SLAMf Series is an elastomer sealed digital thermal mass flow measurement and control instrument, which offers unparalleled flexibility and performance. The SLAMf Series MFC is designed for use in advanced gas handling systems. The result is the most accurate, repeatable, and responsive MFC on the market today! 1

Brooks Digital MFC's and MFM's Wash-down Enclosure The SLAMf Series comes equipped with an IP66 / NEMA4X rated enclosure. This makes these instruments perfect for wash-down or outdoor environments. So no matter how harsh the surroundings, the SLAMf Series keeps the process under control. Wide Flow Range The SLAMf Series covers an extremely broad range of flowrates. Model SLAMf50 can have a full scale flow as low as 3 ccm. With a high turndown ratio of 50:1, accurate gas flow can be measured or controlled down to 0.06 ccm! Model SLAMf53 can meter or control gas flow up to 2500 lpm. Fast response Performance The all-digital electronics and superior mechanical configuration in the SLAMf Series provide for ultra fast response characteristics. Settling times are specified as less than one second, but Brooks Adaptive Valve Control can achieve response times of 0.2 sec. Broad Array of Communication Options Brooks offers traditional 0-5 volt and 4-20mA analog options as well as RS-485 digital communications ( Sprotocol, based on HART). Brooks also offers control interface via digital network protocols like DeviceNet, a high-speed (up to 500k baud) digital communication network, or FOUNDATION Fieldbus. Brooks communication capabilities and device-profiles have been certified by the ODVA (Open DeviceNet Vendor s Association) and the ITK Interoperability Test Kit. Other network protocols are in development. Talk to your Brooks representative about your specific needs. Reduced Cost of Ownership The SLAMf Series allows multi-gas and multi-range capabilities to reduce customer inventory. Storage and pre-programming of up to 10 gas calibrations easily permits users to switch between different gases and ranges on a single device. SPECIFICATIONS PERFORMANCE CHARACTERISTICS: Flow Ranges Models SLAMf50/SLAMf60 Any FS range from 0-3 ccm to 0-30 lpm N 2 Models SLAMf51/SLAMf61 Any FS range from 20-100 lpm N 2 Up to 200 lpm H 2 flow possible Models SLAMf53/SLAMf63 Any FS range from 100-2500 lpm N 2 2 Control Range Turndown 50:1 Data Sheet Accuracy (at calibration conditions) ±1.0% of rate (20% TO 100% FS), ±0.2% FS (below 20% FS) up to 1100 lpm (N 2 ) (Optional: ±0.7% of rate ±0.2% FS ("S-Series" Spec.) up to 1100 lpm (N 2 ) Flow ranges above 1100 lpm and up to 2500 lpm (N 2 ); ±1.0% of FS. Repeatability ±0.20% of rate. Settling Time/Response Time < 1 second to within ±2% FS of final value for a 0-100% command step (better on request) for flow rates up to 100 lpm N 2 < 3 seconds to within ±2% FS of final value for a 0-100% command step (better on request) for flow rates greater than 100 lpm N 2 up to 2500 lpm N 2 Sensitivity to Mounting Attitude <0.2% FS maximum deviation from specified accuracy, after rezeroing. RATINGS: Temperature Sensitivity Zero: less than 0.05% FS per C Span: less than 0.05% FS per C Pressure Sensitivity ± 0.03% per psi up to 200 psig (13.79 bar) (N 2 eq). Maximum Operating Pressure See Table 1 Pressure Equipment Directive (PED) 97/23/EC See Table 1 below: Pressure Differential Range (Controllers) Minimum: Model SLAMf50 5 psi (0.35 bar) up to 30 lpm N 2 Model SLAMf51 10 psi (0.69 bar) from 30 lpm to 100 lpm N 2 Model SLAMf53 7.5 psi (0.52 bar) at 500 lpm N 2 14.5 psi (1.00 bar) at 1000 lpm N 2 35.0 psi (2.41 bar) at 2500 lpm N 2 (consult factory for details) High DP valve 30 to 290 psi (20 bar max.) Low DP valve 7.5 to 30 psi (2 bar max.) Minimum pressure drop depends on gas and FS flow rate (consult factory).

Data Sheet Brooks Digital MFC's and MFM's Table 1 Flow Ranges and Pressure Ratings Mass Flow Mass Flow Pressure Ratings Flow Ranges N2 Equivalent Controller Meter P.E.D. Module H Category Model: Model: Min. FS Max. FS Unit (2) Bar/psi SLAMF50 (1) SLAMF60 (1) 0.003 30 lpm 100bar/1500psi SEP SLAMF51 SLAMF61 20 100 lpm 100bar/1500psi(3) SEP SLAMF53 SLAMF63 100 2500 lpm 70bar/1000psi 1 for all 150lbs flanges 2 for all other connections (1) 300 bar (4500 psi) version optional (2) Refering to normal or standard conditions (on customer request) (3) 70 bar / 1000 psi for UL Certification Leak Integrity Inboard to Outboard: 1x10-9 atm scc/sec Helium max. Ambient Temperature Limits Operating: 0 C to 65 C (32 F to 149 F) Non-Operating: -25 C to 100 C (-13 F to 212 F) Fluid Temperature Limits 0 C to 65 C (32 F to 149 F) PHYSICAL CHARACTERISTICS: Materials of Construction Wetted parts - stainless steel with Viton fluoroelastomers or Buna-N Optional:Kalrez,Teflon /Kalrez and EPDM Certifications: EMC Directive 89/336/EEC: Per EN 61326 Hazardous Location Classification Non-Incendive Enclosure Type 4X / IP66 Ambient Temperature: 0 0 F > Tamb < 150 0 F (0 0 C > Tamb < 65 0 C) United States and Canada UL Listed: E73889 Volume1, Section 25 UL Recognized: E73889 Volume 3, Section 4 Outline Dimensions Refer to Outline Drawings Figures 2 through 9 Process Connections Refer to Outline Drawings Figures 2 through 9 ELECTRICAL CHARACTERISTICS: Electrical Connections Analog I/O Pin Connections: (See Figure 1) Analog/RS-485 version: 15-pin D-Connector, male Digital I/O: DeviceNet: 5-pin Micro-Connector, male FOUNDATION Fieldbus: 4-pin Micro-Connector, male Power Supply Voltage Analog option: (13.5-27 Vdc), 15 Vdc nominal Digital I/O: DeviceNet I/O: 11-25 Vdc FOUNDATION Fieldbus I/O: 14-27 Vdc Power Requirements Watts, typical Watts, max. Analog I/O option, no valve: 1.6 1.8 Analog I/O option, with valve: 3.6 4.0 Digital I/O option, n.v.: 3.6 4.0 Digital I/O option, w.v.: 6.9 7.6 Class I, Zone 2, AEx na II T4 Per ANSI/ISA 12.12.02-2003 and ANSI/UL 60079-15 Ex na II T4 Per CSA - E79-15 Europe - ATEX Directive 94/9/EC KEMA 04ATEX1290X Pressure Equipment Directive (97/23/EC) See pressure Table 1 for further information PC-based Support Tools See Instruction manual X-TMF-SLAMf-MFC-eng for more information. 3

Brooks Digital MFC's and MFM's Data Sheet Analog Terminal Layout Analog I/O Pin Function PIN Setpoint, Command Input (-) 1 Flow Signal, 0(1) -5 volt, Output (+) 2 TTL Alarm, open collector, Output (+) 3 Flow Signal, 0(4)-20 ma, Output (+) 4 Power Supply, +13.5 Vdc to +27 Vdc(+) 5 Not Connected 6 Setpoint, 0(4)-20 ma, Input (+) 7 Setpoint, 0(1)-5 Vdc, Input (+) 8 Power Supply, Common (-) 9 Flow Signal, Common, Output, (-) 10 Reference, +5 Vdc, Output (+) 11 Valve Override, Input 12 Calibration Select Input 13 RS-485 Common B (-) 14 RS-485 Common A (+) 15 Figure 1 Analog, DeviceNet and FOUNDATION Fieldbus Terminal Layouts DeviceNet Terminal Layout FOUNDATION Fieldbus Terminal Layout Figure 2 Model SLAMf50D Digital I/O DeviceNet MFC 4

Data Sheet Brooks Digital MFC's and MFM's Figure 3 Model SLAMf50F Digital I/O FOUNDATION Fieldbus MFC Figure 4 Model SLAMf51 with Cable Gland (PG11, M20 x 1.5, 1/2" NPT) 5

Brooks Digital MFC's and MFM's Data Sheet Figure 5 Model SLAMf53 with Cable Gland (PG11, M20 x 1.5, 1/2" NPT) Figure 6 Model SLAMf60 with Cable Gland (PG11, M20 x 1.5, 1/2" NPT) 6

Data Sheet Brooks Digital MFC's and MFM's Figure 7 Model SLAMf61 with Cable Gland (PG11, M20 x 1.5, 1/2" NPT) Figure 8 Model SLAMf63 with Cable Gland (PG11, M20 x 1.5, 1/2" NPT) 7

Brooks Digital MFC's and MFM's Data Sheet Figure 9 Model SLAMf63 with Cable Gland (PG11, M20 x 1.5, 1/2" NPT) with Flanged Connections BROOKS LOCAL AND WORLDWIDE SUPPORT Brooks Instrument provides sales and service facilities around the world. Calibration facilities are available in locally based sales and service offices. Certified by our local Weights and Measures Authorities and traceable to the relevant international standards. START-UP SERVICE AND IN-SITU CALIBRATION Brooks Instrument can provide start-up service prior to operation when required, if necessary under in-situ conditions, and the results will be traceable to the relevant international quality standards. CUSTOMER SEMINARS AND TRAINING Brooks can provide customer seminars and dedicated training to engineers, end users and maintenance persons. HELP DESK In case you need technical assistance: Americas 1-888-554-FLOW Europe +(31)-318-549-290 Within Netherlands 0318-549-290 Asia +011-81-3-5633-7100 Due to Brooks Instrument's commitment to continuous improvement of our products, all specifications are subject to change without notice. TRADEMARKS Brooks... Brooks Instrument, LLC DeviceNet... Open DeviceNet Vendors Association, Inc. FOUNDATION Fieldbus... Fieldbus FOUNDATION HART... HART Communications Foundation ITK... Fieldbus FOUNDATION Kalrez... DuPont Dow Elastomers ODVA... Open DeviceNet Vendors Association, Inc. Teflon... E.I. DuPont de Nemours & Co. VCO... Cajon Co. VCR... Cajon Co. Viton... DuPont Performance Elastomers 8