Eddy Current Signal Analysis Techniques for Assessing Degradation of Support Plate Structures in Nuclear Steam Generators

Similar documents
EDDY CURRENT TECHNOLOGY FOR HEAT EXCHANGER AND STEAM GENERATOR TUBE INSPECTION

COMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR. S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A.

Electromagnetic Eddy Current Sensors for Evaluation of Sea-Cure and 2205 Duplex Condenser Tubing

EDDY CURRENT MEASUREMENT OF REMOTE TUBE POSITIONS IN CANDU REACTORS S.T. Craig, T.W. Krause, B.V. Luloff and J.J. Schankula Atomic Energy of Canada

ADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING

Application of Guided Wave Technology to Tube Inspection

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

Multiple Frequency Eddy Current Technique

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction

Modelling III ABSTRACT

Simulation Model for SG Eddy Current SG Inspection

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

Studying the Sensitivity of Remote-Field Testing Signals when Faced with Pulling Speed Variations

BALANCE FIELD ELECTROMAGNETIC TECHNIQUE INSPECTION REPORT OF THE 8_INCH_1260_FITTING (HA-2/1200 BLOCK) TESTEX, INC. TESTED: JANUARY 9, 2019

Multivariate Regression Algorithm for ID Pit Sizing

Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing

Steam Generator Tubing Inspection

FLAW DETECTION USING ENCIRCLING COIL EDDY CURRENT SYSTEMS

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

Heat Exchanger & Boiler Tube Inspection Techniques

Magnetic Eddy Current (MEC) Inspection Technique

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

LASER-BASED NDT OF TITANIUM AIRCRAFT ENGINE COMPONENTS J. Doyle Jr and M. J. Brinkman Laser Techniques Company, LLC, Bellevue, USA

DIAGNOSTIC OF CORROSION DEFECTS IN STEAM GENERATOR TUBES USING ADVANCED SIGNAL PROCESSING FROM EDDY CURRENT TESTING

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

Optimized Semi-Flexible Matrix Array Probes for Large Rotor Shafts and DGS Sizing Diagram Simulation Tool

Developments in Electromagnetic Inspection Methods II

High-Precision Internal Diameter Measurements Using Eddy Current Arrays

A Method for Quantitative Analysis of Transient Eddy Current Testing

REPAIR OF NE KRSKO STEAM GENERATOR TUBES BY SLEEVING METHOD

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER

Developments in Ultrasonic Guided Wave Inspection

A SOLUTION TO THE PERMEABILITY AND LIFT-OFF PROBLEMS IN ELECTROMAGNETIC FLAW DETECTION

Developments in Electromagnetic Inspection Methods I

Instruction Manual Veritest

Non-destructive testing Equipment for eddy current examination Array probe characteristics and verification

QUANTITATIVE IMAGE TREATMENT FOR PDI-TYPE QUALIFICATION OF VT INSPECTIONS

R&D of Multi-Frequency ECT Algorithms for FBR SG Tubes

Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor

Testing Critical Medical Tubing Using High Frequency Eddy Current Coils

Eddy Current Testing (ET) Technique

AUTOMATED ANALYSIS OF EDDY CURRENT SIGNALS IN STEAM GENERATOR TUBE INSPECTION

EDDY CURRENT INSPECTION MODELLING OF THE ELBOW OF A STEAM GENERATOR TUBE WITH THE FINITE ELEMENT SOFTWARE «FLUX»

Eddy Current Modelling for Fasteners Inspection in Aeronautic

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

INFLUENCE OF SIGNAL-TO-NOISE RATIO ON EDDY CURRENT SIGNALS OF CRACKS IN STEAM GENERATOR TUBES

AFRL-RX-WP-TP

Detecting 1 st and 2 nd Layer Simulated Cracks in Aircraft Wing Spanwise Splice Standards Using Remote-Field Eddy Current Technique

Target Temperature Effect on Eddy-Current Displacement Sensing

A Numerical Study of Depth of Penetration of Eddy Currents

Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components

FERROUS TUBING PROBES

Fastener Hole Crack Detection Using Adjustable Slide Probes

DATA ANALYSIS ALGORITHMS FOR FLAW SIZING BASED ON EDDY CURRENT ROTATING PROBE EXAMINATION OF STEAM GENERATOR TUBES

AUTOMATED EDDY CURRENT DETECTION OF FLAWS IN SHOT-PEENED

Pipeline Technology Conference 2010

VARIABLE INDUCTANCE TRANSDUCER

Module 4 Design for Assembly IIT BOMBAY

INTEGRITY MANAGEMENT PROGRAMS FOR AGING INFRASTRUCTURES IN HYDROELECTRIC GENERATING STATIONS

Borehole Inspection on Aircraft Structures using Multifrequency EC-Technique

Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT)

New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines

HOME APPLICATION NOTES

Maximizing the Fatigue Crack Response in Surface Eddy Current Inspections of Aircraft Structures

Standard Practice for In Situ Examination of Ferromagnetic Heat-Exchanger Tubes Using Remote Field Testing 1

Characterization of LF and LMA signal of Wire Rope Tester

Advances in Carbon Steel Weld Inspection using Tangential Eddy Current Array

AA&S Conference 2018 Eddy Current Array for Aircraft

Imaging for 3D Eddy Current Nondestructive Evaluation Pasquale Buonadonna Sponsored by: INFM

Detecting Compressive Residual Stress in Carbon Steel Specimens of Flat Geometries Using the Remote-Field Eddy Current Technique

EVALUATION OF INTEGRITY OF AGED PENSTOCK SUPPORTING STRUCTURE IN HYDROELECTRIC GENERATING STATIONS

Fretting Fatigue of Slot-dovetails in Turbo-generator Rotor

Pulsed Eddy Currents: Overcoming Adverse Effects of Galvanized Steel Weather Jacket

Design of a Piezoelectric-based Structural Health Monitoring System for Damage Detection in Composite Materials

MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla

SonaFlex. Set of Portable Multifunctional Equipment for Non-contact Ultrasonic Examination of Materials

System Inputs, Physical Modeling, and Time & Frequency Domains

Experimental Investigation of Crack Detection in Cantilever Beam Using Natural Frequency as Basic Criterion

NDT-PRO Services expands service offering

Microwave Based Non-Destructive Testing using Modified Eddy Current Systems

Effect of fatigue crack orientation on the sensitivity of eddy current inspection in martensitic stainless steels

Detecting Stress Corrosion Cracking with Eddy Current Array Technology Cracking

DIFFICULT TO PIG AND TO INSPECT OFFSHORE PIPES

MultiScan MS 5800 Series

TECH SHEET PEM - REF / TESTING CLINCH PERFORMANCE. SUBJECT: Testing clinch performance of self-clinching fasteners.

MULTI-PARAMETER ANALYSIS IN EDDY CURRENT INSPECTION OF

The jigs and fixtures are the economical ways to produce a component in mass production system. These are special work holding and tool guiding device

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

THE UNDER HUNG VOICE COIL MOTOR ASSEMBLY REVISITED IN THE LARGE SIGNAL DOMAIN BY STEVE MOWRY

Shaft encoders are digital transducers that are used for measuring angular displacements and angular velocities.

18th World Conference on Non-destructive Testing, April 2012, Durban, South Africa

Generator Users Group Annual Conference Core testing, low and high flux, tap. Mladen Sasic, IRIS Power

Emerging NDE Technology for Aging Aircraft

Ensuring Shielding adequacy in Lead shielded spent fuel transportation casks using gamma scanning

Feasibility of Detection of Leaking Fuel Rods Using Side Coupled Guided Waves

NDT KONFERANSEN ZENOVIEA VOROSCIUC

Long Range Ultrasonic Testing - Case Studies

Transcription:

ECNDT 2006 - Th.3.1.2 Eddy Current Signal Analysis Techniques for Assessing Degradation of Support Plate Structures in Nuclear Steam Generators Laura OBRUTSKY, Robert CASSIDY, Miguel CAZAL, Ken SEDMAN, AECL CRL, Nucleoléctrica Argentina Sociedad Anónima, Bruce Power, Argentina Abstract. The steam generator (SG) is one of the most critical components of the heat transfer system in nuclear generation stations. Testing the structural integrity of SG tubing and SG internals is a key element of the fitness-for-service assessments to assure the safe and continuous operation of nuclear power plants. Recent eddy current (ET) inspections of two nuclear power plants revealed degradation of some of the tube support plate (TSP) structures, which was also confirmed by visual inspection. The phenomena was described as metal loss, caused by flow-accelerated corrosion of the carbon steel trefoil support plate and varying from minor to complete loss of the ligaments. This loss of TSP ligaments results in lack of support for the adjacent tubes making them more susceptible to fretting-wear damage and fatigue cracking. A signal analysis method, based on the responses at low frequency of two types of eddy current probes, has been developed to assess the degree of degradation. The standard impedance-mode bobbin probe is used to detect and classify degradation, based on stages of partial or complete breach of ligaments. The advanced transmitreceive array X-probe is used to quantify the degree of degradation in the land regions, and to help discriminate from external magnetite and copper deposits. The complementary information obtained from each of the two probes, combined with the visual inspections, helps to assess the overall condition of the support plates. These procedures, applied to present and past ET inspections, provide the technical basis to determine the location and the progression rate of the degradation. This paper presents the ET analysis methodology along with inspection results showing examples of eddy current signals and visual inspection images. 1. Introduction The main function of the tube support plates (TSP) in any steam generator (SG) or heat exchanger is to restrain the tubes against lateral displacement and vibration. Degradation of the TSP can, therefore, impair their ability to support the tube and thus, it may potentially impair tube integrity. For instance, excessive lateral displacement of the tube can cause vibration-induced fretting-wear or vibration-induced fatigue of the tubes could result in tube rupture. This paper provides a brief overview of the TSP degradation problem, describes the non-destructive testing (NDT) technology applied and the ET analysis procedures developed to detect and quantify TSP degradation, along with examples from the field, showing bobbin probe and X-probe signals compared to visual inspection images. 1

2. TSP Geometry The geometry of the TSP is a tri-lobed shape (broach plate), which leaves three equally spaced lands to support the tube. The flow regions provide space (in the lobes) for the secondary steam and water mixture to rise through each TSP. The array of tri-lobed holes in the TSP leaves ligaments, which can vary from 2.8 mm thick to approximate 4 mm thick, depending on the specific SG design for each station. Figure 1 illustrates the geometry of the Bruce Nuclear Generating Station (NGS) SG supports. Flow region Broach plate ligament Land region Figure 1. Schematic and an in-situ view of a normal broach plate 3. NDT Inspection Technology Complementary information obtained by two types of eddy current probes and the images from visual examination helps assess the integrity of the TSP. Bobbin probe data is used to assess the integrity of the TSP ligaments, whereas the X-probe data can be correlated to clearance between the tube-wall and the individual land regions of the TSP and can also help in the characterization of the overall condition of the TSP and determine the presence of external deposits. The visual inspection results provide the hard evidence to establish these correlations. 3.1 Bobbin Probe Bobbin probes are the industry standard for general inspection of SG and heat exchanger tubes. They are reliable and provide repeatable results, being able to reliably detect and size volumetric flaws such as fretting wear and pitting corrosion. The probe consists of two coils wound in the circumferential direction operating in absolute and differential modes at four test frequencies. Typically, the higher frequencies are used for flaw detection and sizing and a lower frequency, is used to perform multi-frequency mixes for detection of flaws at TSP locations, for locating the TSP and to aid in signal analysis. In this application, the low frequency signals have been used to provide information related to the integrity of TSP. Figure 2 illustrates a typical broach plate signature obtained with a bobbin probe scanning a tube at a support plate location. The signal from a normal or healthy support, seen in Figure 2a which corresponds to location A in Figure 2c, is the result of the change in probe impedance caused by change in the induced eddy currents, which concentrate in the surface of the plate due to the high magnetic permeability of the carbon steel 2

(downwards fraction of the signals) and the magnetic response to the carbon steel (upwards portion of the signal). When the degradation of the TSP has advanced to the point of causing ligament breach, as it is the case in location B in Figure 2c, the flow of eddy currents is interrupted and the signal corresponds only to the magnetic response to the carbon steel as shown in Figure 2b. A B (a) (b) (c) Sample provided by B&W Canada Figure 2. Laboratory simulations of broach plate bobbin probe signals. (a) Normal TSP, (b) total loss of the three ligaments, (c) photograph of laboratory sample Incipient levels of degradation, partial ligament breach and advanced degradation with disintegration of the supports yield characteristic signals that, properly correlated, can be used to assess the condition of each support and whether it still provides tube support. These correlations will be described later in detail. 3.2 X-probe The X-probe is a transmit/receive (T/R) array probe, with performance equivalent to rotating probes. Since all the units in the array are virtually activated simultaneously, the probe can perform single-pass, full-length inspection, at speeds comparable to that of bobbin probes. The array operates at four simultaneous frequencies and it combines circumferential and axial detection mode units in a single probe head, for detection of all modes of degradation and flaw characterization in a single scan [1]. The low frequency is typically used to perform multi-frequency mixes for locating support structures and discriminating ferromagnetic indications. In this application, the low frequency signals provide reliable information to help assess the condition of TSP. The signals from each of the 24 axial detection mode T/R units are displayed in C-scan format, which helps infer the location and morphology of flaws or, in this case, the TSP condition [2]. As explained earlier, the eddy currents concentrate in the surface of the 3

support and are incapable of penetrating the carbon steel TSP thickness and therefore it cannot provide an indication of its thickness. However, the X-probe low frequency response correlates well with the gap between the tube-wall and the TSP material at the broach plate land region (or increasing clearance as the TSP degrade). Figure 3 illustrates signals from a normal broach plate and from a plate with a concentric reduction of 1.7 mm. These values can, therefore, be used to generate sizing curves of signal amplitude versus land region gap as it will be explained in Section 4.3. (a) (b) Figure 3. X-probe responses to (a) normal broach plate and (b) broach plate with a concentric reduction of 1.7 mm 3.3 Visual Inspection Visual inspection with small video cameras, connected to flexible fiber optics, which are inserted in between tube rows and columns, provides images of the SG internals and in particular of the TSP condition. These images are the hard evidence needed to establish correlations between the eddy current signals and the actual stage of degradation. Several access ports were opened to facilitate the insertion of the visual aids at different elevations and sides of the SG. These images helped confirming the eddy current indications of TSP degradation and also the presence of magnetic deposits blocking the steam flow in the hot leg of the Embalse NSG SG. 4

4. Methodology to Quantify Degradation 4.1 Degradation Morphology The degradation mechanism is described as flow accelerated corrosion, which depends on a) water chemistry, b) thermal hydraulic parameters such as temperature, steam and water velocities, steam quality and other two phase flow characteristics, c) local geometry causing changes in velocity and pressure, which can cause high local velocities, flashing and turbulence that enhances the mass transfer from the corroding surface and d) material composition [3]. These conditions are different in the two examples cited here and consequently the morphology of the degradation is also different. The degradation of the Bruce NGS TSP starts typically in the flow region at the bottom of the support and tapers towards the top projecting into the land region, resulting in a conical shape at each land as illustrated in the picture shown in Figure 4a. In contrast, the degradation of the Embalse NSG broach plates also starts in the flow region but typically, is uniform along the plate as illustrated in Figure 4b. Because of these two distinctive morphologies, the signals generated by the bobbin probe in each case are somewhat dissimilar and therefore, different criteria are required in each case to categorize the stage of degradation. Corroded flow region Uniform corrosion of the plate Remaining ligament (a) (b) Figure 4. Visual examination images (a) Tapered corrosion in Bruce SG, (b) Uniform corrosion in Embalse SG 4.2 Assessment of Degradation Progression with Bobbin Probe TSP with early stages of ligament degradation produce small distortions in the bobbin probe signals. The downward portion of the lissajous signal shown in Figure 2a decreases gradually and the signal rotates counterclockwise. Once the ligament breaches, the eddy currents do not have a return path and therefore the signal only comprises an upward portion as shown in Figure 2b. These gradual changes in the eddy current signals, correlated to the different stages of degradation, allow a classification into 6 categories or degradation levels using signal amplitude-based criteria. Figure 5 shows examples of field signals in these categories from (a) Bruce SG and (b) Embalse SG. The first two levels correspond to distorted broach plate signals (DBP) with no breach of the ligaments. The 5

peak-to peak voltage (Vpp) of the signal, the phase angle and the vertical voltage (Vmx) of the initial downward portion of the signal are monitored. This vertical component, Vmx, decreases as the ligament deteriorates and when it reaches a 0.5 volts threshold, it is usually a good indication that the ligament is either partially or totally broken. Once the degradation has reached this point, the Vpp and the phase angle of the signal are monitored to determine the different degradation levels. Further reduction of Vpp, i.e.: less than 5 volts for Bruce and 3 volts for Embalse, is indicative of advanced deterioration of the TSP, to its virtual disintegration. The images in Figure 6 illustrate the levels of degradation from level 1 to level 4. Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 (a) Level 0 Level 1 Level 2 Level 3 Level 4 (b) Figure 5. Degradation progression based of bobbin probe signals from (a) Bruce SG and (b) Embalse SG Ligament breach Level 1 Level 2 Level 3 Level 4 Figure 6. Degradation progression based of visual examination from Embalse SG 4.3 Assessment of Degradation Progression with X-Probe While the bobbin probe data provides information about the overall degradation of the supports and the condition of the ligaments, the X-probe data provides a tool to assess the amount of tube-support provided by the remaining lands at each location. The signal amplitude from each land decreases rapidly as the land deteriorates. A 1 mm gap between 6

the tube wall and the land area is almost ½ of the probe response from a non-degraded land; probe response from a 2 mm gap is approximately ¼ of the signal from a non-degraded land. Therefore, the normalized probe response from the land region, Vpp, is plotted to produce sizing curves that are used to measure the clearance between each land and the tube-wall as illustrated in Figure 7 [4]. The signals from the carbon steel ring in the calibration tube are normalized to 10 volts peak-to-peak and hence, the average response from a non-degraded TSP is nearly this value. Theoretically, the minimum value in this curve corresponds to a completely degraded land region, or the TSP ligament thickness, and therefore, any lower values are hypothetical. Since the broach plate geometry in each of the two cases is different, these values are also different. A completely degraded TSP in the Embalse case corresponds to a 2.8 mm gap whereas, in the Bruce case, the gap is 4 mm. If the tube is centred relative to the original location inside a degraded broach plate, the signals from a completely degraded land region should be zero (broken ligament). However, due to eccentricity inside the broach plate this value can be larger and therefore, extrapolated values have been added to quantify these cases [3]. Calibration curve 6 Degradation (mm) 5 4 3 2 1 y = -1.7162Ln(x) + 3.9813 0 0 2 4 6 8 10 Normalized probe response Land region cal curve Extrapolated values Log. (Land region cal curve) Figure 7. Sizing curve of land degradation vs. normalized probe response 5. Field Examples The results from the field shown in Figure 8 illustrate the excellent correlation and complementary information obtained from the NDT techniques. In this example, we show the bobbin probe signals from a broach plate typical of ligament breach (level 4), while the X-probe and the photograph show large deterioration of two land regions. In fact, the signals with both probes and the photograph confirm that one portion of the broach plate has actually fallen down and it is sitting on top of the next broach plate. 7

Level 4 signal Broach plate in adjacent tube location Ligaments missing Broach plate signal Section that has fallen from upper support Broach plate Figure 8. Eddy current signals and visual inspection images from a tube location where the upper TSP has total ligament breach. The images and signals shown in the upper figures indicate that part of the ligaments are missing, which have fallen down on top of the next broach plate as shown in the bottom figures. 6. Conclusions A method for signal analysis to assess the degree of degradation of carbon steel TSP has been developed. It is based on the responses at low frequency from two types of eddy current probes. The standard impedance-mode bobbin probe is used to detect and classify degradation, based on stages of partial or complete breach of ligaments. The advanced transmit-receive array X-probe is used to quantify the degree of degradation in the land regions, and to help discriminate from external magnetite and copper deposits. The complementary information obtained from each of the two probes, combined with the visual inspections, helps to assess the overall condition of the TSP. These procedures can be applied to present and past ET inspections and therefore provide the technical basis to determine the location and the progression rate of the degradation. These techniques can also be applicable to assess structural integrity of other SG or heat exchanger internals. 8

7. References [1] L. Obrutsky, N. Watson, C. Fogal, M. Cantin, V. Cecco, R. Lakhan and S. Sullivan, Fast Single- Pass Eddy Current Array Probe For Steam Generator Inspection, Proceedings of the 4 th CNS International Steam Generator Conference, Toronto, 2002. [2] L.S. Obrutsky, B. Lepine, J. Lu, R. Cassidy and J. Carter, Eddy Current Technology for Heat Exchanger and Steam Generator Tube Inspection, Proceedings of the 16th World Conference in Nondestructive Testing, Montreal, Canada, August 30 September 3, 2004. [3] K.G. Sedman, G.E. Galan and B. Dicks, Boiler Tube Support Plate Degradation in Bruce Unit 8, Proceedings of the 7 th CNS International Conference on CANDU Maintenance, Toronto, November 2005. [4] L. Obrutsky, N. Valliere and Ivan Vela, Inspection Techniques for Detecting Degraded Support Plates in Bruce B Steam Generators with Bobbin Probe and X-probe, 23rd EPRI Steam Generator NDE Workshop, Chicago, Illinois, July 11-14, 2004. 9