Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS CENTRALIZED MODELS PLUS

Similar documents
Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS ULTRA CORE PLUS

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

MICRO-0.25-I-OUTD MICRO-0.3-I-OUTD

Power-One, worldwide leader for power supplier and renewable energy products

Growatt 4000 UE / 5000 UE / 6000 UE

BAT-Series Grid Inverter. Battery Charger.

PV Grid-connected Inverter

PV Grid-connected Inverter

FRONIUS IG PLUS TRANSFORMER INVERTER

THEIA series. StRing inverters

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

SM2000 TECHNICAL DESCRIPTION

This Chapter contains:

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

MAJORSINE Power Inverter

Photovoltaic / Solar Array Simulation Solution

Company Profile. Skype: carrie.rong Mob/Whatsapp: Web:

Solar Charge Controller Inverter

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

ASEP Industrial Electronics Co., Ltd

Agilent N8700 Series System DC Power Supplies

/ The allrounder with maximum yield. Technical data: Fronius IG Plus (25 V-1, 30 V-1, 35 V-1, 50 V-1, 55 V-1, 60 V-1)

Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool

TECHNICAL DATA FRONIUS SYMO ( M, M, M, M, M)

Ku-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

/ PC board replacement. / Smart Grid Ready TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

Orbital GFI Inverter Series

The future-proof inverter for small self-consumption systems

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

03 / Data Sheet. PIKO-Inverter

96.2 % 400 V AC V DC. Advantage. Features IP 20. Accessories MAXIMUM EFFICIENCY OUTPUT VOLTAGE MPPT VOLTAGE RANGE

R4850G1 Rectifier User Manual V1.3

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

- 1 - GTI Grid Series. GTI Series Inverters For Grid User Manual

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

GTI Series Inverters User Manual

ABB solar inverters. Product manual TRIO-20.0/27.6-TL-OUTD (20.0 to 27.6 kw)

HD WAVE INVERTERS. (+34) Skype

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

FJB/IFB enclosures Photovoltaic string protection and monitoring enclosures for solar parks from 8 to 32 strings

Gutor PxW AC UPS Designed for North American Market

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Keysight Technologies N8700 Series System DC Power Supplies

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

/ The allrounder with maximum yield. / Smart Grid Ready. / WLAN interface

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Parallel AMX AC Power Systems

Technical Data Sheets

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

S11 Adjustable Speed Drive Engineering Specification

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

PowerFlex 400 Submittal

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

AUM FAMILY Programmable DC Power Supplies

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Digital Ground Resistance Tester. Model 4610 & 4610 Kits

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES

MYS WWSP PLUS III POWER UNIT

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

Power supply CP-E 24/20.0

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Tel: Fax:

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

CP /240-MC4 User Manual

GET IN TOUCH: Global: DE: AU: UK:

100kW Grid-tied PV Inverter

Keysight N9310A RF Signal Generator

Power supply CP-E 24/2.5

SSEG DETAILS (Small-Scale Embedded Generator) SSEG Type Reference: SSEG Model Reference:

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

R&D TECHNICAL SPECIFI

Agenda. 1. Inverter technology. 2. Monitor system. 3. System application. 4. Error Codes and trouble-shooting

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

EL-AC Electronic Load

TECHNICAL DATA SHEET. smartflower POP. As of: August 2015 Typing and printing errors reserved.

Keysight Technologies Photovoltaic / Solar Array Simulation Solution N8937APV (1500 V, 15 kw, 208 VAC) N8957APV (1500 V, 15 kw, 400 VAC) DG8901A SAS

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

ODEN AT Primary Current Injection Test System

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Transcription:

PVI-55.0 PVI-110.0 PVI-165.0/220.0 PVI-275.0/330.0 PLUS GENERAL SPECIFICATIONS CENTRALIZED MODELS These extremely scalable modular inverter systems, based on 55kW modular blocks, increase usable power and improve availability. The reduction of performance in any individual module will not impact the energy-harvesting capabilities of other modules. The product is available with and without transformer. Industry-leading power conversion efficiencies of up to 98% (-TL), combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested, significantly reducing on-site wiring and testing. In case of ungrounded application the unit can be configured as single or multiple MPPT (with exception of PVI-55.0/-TL). Features Reduced susceptibility to a single fault. In case of a component failure, a maximum of 55kW will be lost Reduced acoustic noise due to the high switching frequency Reverse-polarity protection minimizes potential damage caused by array mis-wiring Maximum input voltage up to 1000Vdc, high design flexibility and reduced DC distribution losses for large scale PV plants Integrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not required Easy installation and maintenance procedure. Front extractible DC/AC converters and accessibility to all critical parts High efficiencies deliver more energy Two independent RS-485 communication interfaces for inverter and intelligent string combiner monitoring Integrated DC disconnect switch for each 55 kw module AC and DC side integrated protection (fuses and OVR) easily replaceable Compliant to BDEW 1

PVI-55.0 PVI-55.0-TL PVI-110.0 PVI-110.0-TL GENERAL SPECIFICATIONS CENTRALIZED MODELS PVI-55.0 PVI-55.0-TL PVI-110.0 PVI-110.0-TL Effi Efficiency ciency PVI-110.0 2 PVI-55.0 8 9 8 9

PARAMETER PVI-55.0 PVI-55.0-TL PVI-110.0 PVI-110.0-TL Input Side Absolute Maximum DC Input Voltage (V max,abs) 1000 V 1000 V MPPT Input DC Voltage Range (V MPPTmin,r... V MPPTmax,r) 485...950 V 485...950 V MPPT Input DC Range (V MPPTmin,f... V MPPTmax,f) at Full Power 485...850 V 485...850 V Number of Independent MPPT Multi-Master 1 2 Number of Independent MPPT Multi - Master/Slave Not applicable Not applicable Number of Independent MPPT Master/Slave 1 1 Maximum Combined DC Input Current (I dcmaxc) 124 A 248 A Maximum DC Input Current for Each Module (I dcmax,m) 124 A 124 A Number of DC Inputs Pairs 1 2 DC Connection Type 1x185mm 2 (M10) 1x185mm 2 (M10) + 1x300mm 2 (M12) Input Protection Reverse Polarity Protection YES, with series diode YES, with series diode Input Over Voltage Protection - Varistor 2 for each input pair, Class II 2 for each input pair, Class II Photovoltaic Array Isolation Control According to local standard According to local standard Fuse Size for Each Input Pair 125 A / 1000 V 125 A / 1000 V Output Side AC Grid Connection Type Three phases (Δ / Υ) Three phases (Δ) Three phases (Δ / Υ) Three phases (Δ) Rated AC Power (P ac,r) 55 kw 110 kw Rated Grid Voltage (V ac,r) 400 V 320 V 400V 320 V AC Voltage Range (V acmin...v acmax) 320...480 V (1) 256...368 V (1) 320...480 V (1) 256...368 V (1) Maximum Output Current (I ac,max) 81 A 100 A 160 A 200 A Rated Frequency (f r) 50/60 Hz 50/60 Hz Frequency Range (f min...f max) 47...53 / 57...63 Hz (2) 47...53 / 57...63 Hz (2) Power Factor (Cosphi ac,r) > 0.995 (adj. ± 0.90) (3) > 0.995 (adj. ± 0.90) (3) Total Harmonic Distortion < 3% (@ P ac,r ) < 3% (@ P ac,r ) AC Connection Type 1 x 95 mm 2 (M8) 1 x 300 mm 2 (M12) 1 x 95 mm 2 (M8) 1 x 300 mm 2 (M12) Output Protection Anti-Islanding Protection According to local standard According to local standard Output Overvoltage Protection (Varistor) Yes, Class II Yes, Class II Night Time Disconnect Yes Yes AC Circuit Breaker 50 ka 50 ka Operating Performance Maximum Efficiency (η max) 96. 98.0 96. 98.0 Weithted Efficiency (η EURO / η CEC) 95.1% / 96. 97.7% / 98. 95.2% / 96. 97.7% / 98. Stand-by Consumption/Night-time power loss < 17 W < 23 W < 24 W < 19 W AC Auxiliary Supply 3x400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 Hz Auxiliary Supply Consumption < 0.36% of P ac,r < 0.31% of P ac,r Auxiliary Supply Consumption without Cooling < 0.25% of P ac,r < 0.23% of P ac,r Inverter Switching Frequency 18 khz 18 khz Communication Wired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.) Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.) User Interface 16 characters x 2 line LCD display for each module 16 characters x 2 line LCD display for each module Environmental Ambient Temperature Range Relative Humidity 0...95% non condensing 0...95% non condensing Noise Emission <62 db(a) @ 1 m < 63 db (A) @ 1 m Maximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ft Physical Environmental Protection Rating IP 20 IP 20 Cooling Air Forced Air Forced Required Air Cooling Flow 1600 m 3 /h - 944 CFM 2800 m 3 /h - 1652 CFM 2400 m 3 /h - 1416 CFM Dimension (H x W x D) 1675mm x 1250mm x 850mm 1077mm x 1250mm x 850mm 1675mm x 1250mm x 850mm 1077mm x 1250mm x 850mm / 69.5 x 49,2 x 33.5 / 42.4 x 49.2 x 33.5 / 65.9 x 49.2 x 33.5 / 42,4 x 49.2 x 33.5 Weight < 700 kg / 1543 lb < 350 kg / 771 lb < 800 kg / 1765 lb < 480 kg / 1058 lb Weight of the module < 60 kg / 132 lb < 60 kg / 132 lb Safety Transformer Yes No Yes No Marking CE CE Safety and EMC Standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, Grid Standard Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663 1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Power factor variations beyond ±0.9 imply a reduction of the active power 3

PVI-165.0 / PVI-165.0-TL PVI-220.0 / PVI-220.0-TL GENERAL SPECIFICATIONS CENTRALIZED MODELS PVI-165.0 PVI-165.0-TL PVI-220.0 PVI-220.0-TL Effi Efficiency ciency PVI-55.0/330.0-TL PVI-165.0/220.0 100,00 99,00 4 8 9 8 9

PARAMETER PVI-165.0 PVI-165.0-TL PVI-220.0 PVI-220.0-TL Input Side Absolute Maximum DC Input Voltage (V max,abs) 1000 V 1000 V MPPT Input DC Voltage Range (V MPPTmin,r... V MPPTmax,r) 485...950 V 485...950 V MPPT Input DC Range (V MPPTmin,f... V MPPTmax,f) at Full Power 485...850 V 485...850 V Number of Independent MPPT Multi-Master 3 4 Number of Independent MPPT Multi - Master/Slave 2 2 Number of Independent MPPT Master/Slave 1 1 Maximum Combined DC Input Current (I dcmaxc) 372 A 496 A Maximum DC Input Current for Each Module (I dcmax,m) 124 A 124 A Number of DC Inputs Pairs 3 4 DC Connection Type 2x185mm 2 (M10) + 1x300mm 2 (M12) 2x185mm 2 (M10)+ 2x300mm 2 (M12) Input Protection Reverse Polarity Protection YES, with series diode YES, with series diode Input Over Voltage Protection - Varistor 2 for each input pair, Class II 2 for each input pair, Class II Photovoltaic Array Isolation Control According to local standard According to local standard Fuse Size for Each Input Pair 125 A / 1000 V 125 A / 1000 V Output Side AC Grid Connection Type Three phases (Δ / Υ) Three phases (Δ) Three phases (Δ / Υ) Three phases (Δ) Rated AC Power (P ac,r) 165 kw 165 kw 220 kw 220 kw Rated Grid Voltage (V ac,r) 400 V 320 V 400 V 320 V AC Voltage Range (V acmin...v acmax) 320...480 V (1) 256...368 V (1) 320...480 V (1) 256...368 V (1) Maximum Output Current (I ac,max) 240 A 300 A 320 A 400 A Rated Frequency (f r) 50/60 Hz 50/60 Hz Frequency Range (f min...f max) 47...53 / 57...63 Hz (2) 47...53 / 57...63 Hz (2) Power Factor (Cosphi ac,r) > 0.995 (adj. ± 0.90) (3) > 0.995 (adj. ± 0.90) (3) Total Harmonic Distortion < 3% (@ P ac,r ) < 3% (@ P ac,r ) AC Connection Type 1 x 185 mm 2 (M10) 2 x 300 mm 2 (M12) 1 x 185 mm 2 (M10) 2 x 300 mm 2 (M12) Output Protection Anti-Islanding Protection According to local standard According to local standard Output Overvoltage Protection (Varistor) Yes, Class II Yes, Class II Night Time Disconnect Yes Yes AC Circuit Breaker 50 ka 50 ka Operating Performance Maximum Efficiency (η max) 96. 98.0 96. 98.0 Weithted Efficiency (η EURO / η CEC) 95.3% / 96. 97.7% / 98. 95.3% / 96. 97.7% / 98. Stand-by Consumption/Night-time power loss < 31 W < 26 W < 28 W < 33 W AC Auxiliary Supply 3 x 400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 Hz Auxiliary Supply Consumption < 0. of P ac,r < 0.28% of P ac,r Auxiliary Supply Consumption without Cooling < 0.23% of P ac,r Inverter Switching Frequency 18 khz 18 khz Communication Wired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.) Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.) User Interface 16 characters x 2 line LCD display for each module 16 characters x 2 line LCD display for each module Environmental Ambient Temperature Range Relative Humidity 0...95% non condensing 0...95% non condensing Noise Emission < 68 db (A) @ 1 m < 66 db (A) @ 1 m < 72 db (A) @ 1 m < 69 db (A) @ 1 m Maximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ft Physical Environmental Protection Rating IP 20 IP 20 Cooling Air Forced Air Forced Required Air Cooling Flow 4000 m 3 /h - 2360 CFM 3200 m 3 /h - 1888 CFM 4800 m 3 /h - 2832 CFM 4000 m 3 /h - 2360 CFM Dimension (H x W x D) 2184mm x 1250mm x 850mm / 86.0 x 49.2 x 33.5 1675mm x 1250mm x 850mm / 65,9 x 49,2 x 33.5 2184mm x 1250mm x 850mm / 86.0 x 49.2 x 33.5 1675mm x 1250mm x 850mm / 65,9 x 42,9 x 33.5 Weight < 1200 kg / 2646 lb < 680 kg / 1500 lb < 1300 kg / 2867 lb < 780 kg / 1720 lb Weight of the module < 60 kg / 132 lb < 60 kg / 132 lb Safety Transformer Yes No Yes No Marking CE CE Safety and EMC Standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, Grid Standard Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663 1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Power factor variations beyond ±0.9 imply a reduction of the active power 5

PVI-275.0 / PVI-275.0-TL PVI-330.0 / PVI-330.0-TL GENERAL SPECIFICATIONS CENTRALIZED MODELS PVI-275.0 PVI-275.0-TL PVI-330.0 PVI-330.0-TL Effi Efficiency ciency PVI-55.0/330.0-TL PVI-275.0/330.0 100,00 99,00 6 8 9 8 9

PARAMETER PVI-275.0 PVI-275.0-TL PVI-330.0 PVI-330.0-TL Input Side Absolute Maximum DC Input Voltage (V max,abs) 1000 V 1000 V MPPT Input DC Voltage Range (V MPPTmin,r... V MPPTmax,r) 485...950 V 485...950 V MPPT Input DC Range (V MPPTmin,f... V MPPTmax,f) at Full Power 485...850 V 485...850 V Number of Independent MPPT Multi-Master 5 6 Number of Independent MPPT Multi - Master/Slave 3 3 Number of Independent MPPT Master/Slave 1 1 Maximum Combined DC Input Current (I dcmaxc) 620 A 744 A Maximum DC Input Current for Each Module (I dcmax,m) 124 A 124 A Number of DC Inputs Pairs 5 6 DC Connection Type 3x185mm 2 (M10) +2x300mm 2 (M12) 3x185mm 2 (M10) +3x300mm 2 (M12) Input Protection Reverse Polarity Protection YES, with series diode YES, with series diode Input Over Voltage Protection - Varistor 2 for each input pair, Class II 2 for each input pair, Class II Photovoltaic Array Isolation Control According to local standard According to local standard Fuse Size for Each Input Pair 125 A / 1000 V 125 A / 1000 V Output Side AC Grid Connection Type Three phases (Δ / Υ) Three phases (Δ) Three phases (Δ / Υ) Three phases (Δ) Rated AC Power (P ac,r) 275 kw 330 kw Rated Grid Voltage (V ac,r) 400 V 320 V 400 V 320 V AC Voltage Range (V acmin...v acmax) 320...480 V (1) 256...368 V (1) 320...480 V (1) 256...368 V (1) Maximum Output Current (I ac,max) 400 A 500 A 480 A 600 A Rated Frequency (f r) 50/60 Hz 50/60 Hz Frequency Range (f min...f max) 47...53 / 57...63 Hz (2) 47...53 / 57...63 Hz (2) Power Factor (Cosphi ac,r) > 0.995 (adj. ± 0.90) (3) > 0.995 (adj. ± 0.90) (3) Total Harmonic Distortion < 3% (@ P ac,r ) < 3% (@ P ac,r ) AC Connection Type 1 x 240 mm 2 (M12) 2 x 300 mm 2 (M12) 1 x 240 mm 2 (M12) 2 x 300 mm 2 (M12) Output Protection Anti-Islanding Protection According to local standard According to local standard Output Overvoltage Protection (Varistor) Yes, Class II Yes, Class II Night Time Disconnect Yes Yes AC Circuit Breaker 50 ka 50 ka Operating Performance Maximum Efficiency (η max) 96. 98.0 96. 98.0 Weithted Efficiency (η EURO / η CEC) 96.5% / 96. 97.7% / 98. 96.5% / 96. 97.7% / 98. Stand-by Consumption/Night-time power loss < 45 W < 40 W < 52 W < 47 W AC Auxiliary Supply 3 x 400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 Hz Auxiliary Supply Consumption < 0.29% of P ac,r < 0.28% of P ac,r Auxiliary Supply Consumption without Cooling Inverter Switching Frequency 18 khz 18 khz Communication Wired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.) Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.) User Interface 16 characters x 2 line LCD display for each module 16 characters x 2 line LCD display for each module Environmental Ambient Temperature Range Relative Humidity 0...95% non condensing 0...95% non condensing Noise Emission < 75 db (A) @ 1 m < 72 db (A) @ 1 m < 78 db (A) @ 1 m < 75 db (A) @ 1 m Maximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ft Physical Environmental Protection Rating IP 20 IP 20 Cooling Air Forced Air Forced Required Air Cooling Flow 6800 m 3 /h - 4012 CFM 4800 m 3 /h - 2832 CFM 7600 m 3 /h - 4484 CFM 5600 m 3 /h - 3304 CFM 2184mm x 1250mm x 850mm 2184mm x 1250mm x 850mm Dimension (H x W x D) / 86.0 x 49.2 x 33.5 2184mm x 1250mm x 850mm / 86.0 x 49.2 x 33.5 2184mm x 1250mm x 850mm 1215mm x 1250mm x 870mm / 86.0 x 49.2 x 33.5 1215mm x 1250mm x 870mm / 86.0 x 49.2 x 33.5 / 47.8 x 49.2 x 34.3 (Transf.) / 47.8 x 49.2 x 34.3 (Transf.) Weight < 1600 kg / 3527 lb < 1000 kg / 2205 lb < 1750 kg / 3858 lb < 1150 kg / 2535 lb Weight of the module < 60 kg / 132 lb < 60 kg / 132 lb Safety Transformer Yes No Yes No Marking CE CE Safety and EMC Standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, Grid Standard Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663 1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Power factor variations beyond ±0.9 imply a reduction of the active power 7

Ver. 2011-02.2-EN - All products are subject to technical improvements without notice. www.power-one.com Power-One Renewable Energy Worldwide Sales Offices Country Name/Region Telephone Email Australia Asia Pacific +61 2 9735 3111 sales.australia@power-one.com China Asia Pacific +86 755 2988 5888 ext.5588 sales.china@power-one.com Singapore Asia Pacific +65 6896 3363 sales.singapore@power-one.com France Europe 00 800 00287672 Choix n 4 sales.france@power-one.com Germany Europe +49 7641 955 2020 sales.germany@power-one.com Italy Europe +39 055 9195 396 sales.italy@power-one.com Spain Europe +34 629253564 sales.spain@power-one.com United Kingdom Europe +44 1903 823 323 sales.uk@power-one.com Dubai Middle East +971 50 100 4142 sales.dubai@power-one.com Canada North America +1 877 261-1374 sales.canada@power-one.com USA East North America +1 877 261-1374 sales.usaeast@power-one.com USA Central North America +1 877 261-1374 sales.usacentral@power-one.com USA West North America +1 877 261-1374 sales.usawest@power-one.com 8