Pre- and Post Ringing Of Impulse Response

Similar documents
Linear-Phase and Minimum-phase Subwoofers

Single Channel MLS Measurement System

Ultimate Equalizer V8.0 Supplemental User Manual

THE PERCEPTION OF ALL-PASS COMPONENTS IN TRANSFER FUNCTIONS

a Full Range System Excelsior Audio Design & Services State of the Art Loudspeaker Design for Live Sound Subwoofer Alignment with a Full Range System

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

Excelsior Audio Design & Services, llc

What applications is a cardioid subwoofer configuration appropriate for?

Psycho-acoustics (Sound characteristics, Masking, and Loudness)

Improving room acoustics at low frequencies with multiple loudspeakers and time based room correction

Processor Setting Fundamentals -or- What Is the Crossover Point?

Excelsior Audio. Subwoofer Alignment with a Full Range System. a Full Range System Excelsior Audio Design & Services, LLC

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

APPLICATION NOTE MAKING GOOD MEASUREMENTS LEARNING TO RECOGNIZE AND AVOID DISTORTION SOUNDSCAPES. by Langston Holland -

Professional Loudspeaker Systems and their Real World applications. High Performances Crossovers for. By Mario Di Cola, Audio Labs Systems,

You know about adding up waves, e.g. from two loudspeakers. AUDL 4007 Auditory Perception. Week 2½. Mathematical prelude: Adding up levels

Introduction to Equalization

FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE

Results of Egan and Hake using a single sinusoidal masker [reprinted with permission from J. Acoust. Soc. Am. 22, 622 (1950)].

From time to time it is useful even for an expert to give a thought to the basics of sound reproduction. For instance, what the stereo is all about?

ONLINE TUTORIALS. Log on using your username & password. (same as your ) Choose a category from menu. (ie: audio)

datasheet TQ-445 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Three-way, bi-amp design Exceptional audio clarity 60 x 40 dispersion

SIA Software Company, Inc.

A CLOSER LOOK AT THE REPRESENTATION OF INTERAURAL DIFFERENCES IN A BINAURAL MODEL

MUS 302 ENGINEERING SECTION

datasheet TCS-40 TCS SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Dual 8 LF drivers Wide dispersion High power rating Down-fill enclosure

Combining Subjective and Objective Assessment of Loudspeaker Distortion Marian Liebig Wolfgang Klippel

Surround: The Current Technological Situation. David Griesinger Lexicon 3 Oak Park Bedford, MA

A3D Contiguous time-frequency energized sound-field: reflection-free listening space supports integration in audiology

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Binaural Hearing. Reading: Yost Ch. 12

datasheet TQ-315 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS CEW technology Trapezoidal cabinet Rotatable HF waveguide

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007

Design of a Line Array Point Source Loudspeaker System

THE USE OF VOLUME VELOCITY SOURCE IN TRANSFER MEASUREMENTS

DESIGN OF ROOMS FOR MULTICHANNEL AUDIO MONITORING

Perception of pitch. Definitions. Why is pitch important? BSc Audiology/MSc SHS Psychoacoustics wk 5: 12 Feb A. Faulkner.

Perception of pitch. Definitions. Why is pitch important? BSc Audiology/MSc SHS Psychoacoustics wk 4: 7 Feb A. Faulkner.

datasheet THL-4.3 HILIGHT SERIES ENGINEERING FEATURES APPLICATIONS Controlled dispersion Seamless mid range Ultra-low distortion Sound contracting

ECMA TR/105. A Shaped Noise File Representative of Speech. 1 st Edition / December Reference number ECMA TR/12:2009

AN AUDITORILY MOTIVATED ANALYSIS METHOD FOR ROOM IMPULSE RESPONSES

ENGINEERING STAFF REPORT. The JBL Model L40 Loudspeaker System. Mark R. Gander, Design Engineer

Technical Guide. Installed Sound. Recommended Equalization Procedures. TA-6 Version 1.1 April, 2002

Realtime auralization employing time-invariant invariant convolver

Understanding Ultrasonic Signal Analysis By Thomas J. Murphy C.Eng.

REAL-TIME BROADBAND NOISE REDUCTION

datasheet THL HILIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Controlled dispersion Seamless mid range Ultra-low distortion

What is Sound? Part II

Perception of pitch. Importance of pitch: 2. mother hemp horse. scold. Definitions. Why is pitch important? AUDL4007: 11 Feb A. Faulkner.

datasheet TCS-35 FEATURES APPLICATIONS Compact enclosure Wide dispersion Full range response OmniMount compatible Surround sound Background sound

Earl R. Geddes, Ph.D. Audio Intelligence

Phase Correction System Using Delay, Phase Invert and an All-pass Filter

EBU UER. european broadcasting union. Listening conditions for the assessment of sound programme material. Supplement 1.

Since the advent of the sine wave oscillator

Finding the Prototype for Stereo Loudspeakers

Ultimate Equalizer DSP Loudspeaker Management System April 14, 2014

The Mimir. Enclosure and stuffing. Drive units

Tone-in-noise detection: Observed discrepancies in spectral integration. Nicolas Le Goff a) Technische Universiteit Eindhoven, P.O.

THE BEATING EQUALIZER AND ITS APPLICATION TO THE SYNTHESIS AND MODIFICATION OF PIANO TONES

Psychoacoustic Cues in Room Size Perception

Practical Impedance Measurement Using SoundCheck

Quadra 10 Available in Black and White

Chapter 7: Signal Processing (SP) Tool Kit reference

Practical Applications of the Wavelet Analysis

Complex Sounds. Reading: Yost Ch. 4

SGN Audio and Speech Processing

IMPULSE RESPONSE MEASUREMENT WITH SINE SWEEPS AND AMPLITUDE MODULATION SCHEMES. Q. Meng, D. Sen, S. Wang and L. Hayes

RD75, RD50, RD40, RD28.1 Planar magnetic transducers with true line source characteristics

Audio Engineering Society. Convention Paper. Presented at the 115th Convention 2003 October New York, New York

Quadra 15 Available in Black and White

Whitepaper: The Perfect XO for High End Stereo Systems?!

Measurement of Weighted Harmonic Distortion HI-2

JBL-Smaart Pro Application Note. Using The JBL-Smaart Pro Delay Locator

datasheet THL-2 HILIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Ultra low distortion Seamless midrange Wide dispersion

APPLICATIONS OF DYNAMIC DIFFUSE SIGNAL PROCESSING IN SOUND REINFORCEMENT AND REPRODUCTION

Perception of low frequencies in small rooms

Loudspeakers. Juan P Bello

Holland, KR, Newell, PR, Castro, SV and Fazenda, BM

SGN Audio and Speech Processing

AUDL GS08/GAV1 Signals, systems, acoustics and the ear. Loudness & Temporal resolution

Technical Note Vol. 1, No. 10 Use Of The 46120K, 4671 OK, And 4660 Systems in Fixed instaiiation Sound Reinforcement

Linear Phase Brick Wall Crossovers

Tones in HVAC Systems (Update from 2006 Seminar, Quebec City) Jerry G. Lilly, P.E. JGL Acoustics, Inc. Issaquah, WA

Hearing and Deafness 2. Ear as a frequency analyzer. Chris Darwin

UBL S119 LOUDSPEAKER SYSTEM

Measurement of Amplitude Modulation AN 6

Lesson 3 Measurement of sound

Experiment 2 Effects of Filtering

ED120A 12 (305mm), 2-way, Full-range, CORE Processed, Powered, Loudspeaker System

Michael F. Toner, et. al.. "Distortion Measurement." Copyright 2000 CRC Press LLC. <

Appendix A Decibels. Definition of db

Acoustical Testing 1

DEEP LEARNING BASED AUTOMATIC VOLUME CONTROL AND LIMITER SYSTEM. Jun Yang (IEEE Senior Member), Philip Hilmes, Brian Adair, David W.

04 August 2017 Charlie Hughes. Optimizing Loudspeaker Directivity Through the Crossover Region

FFT 1 /n octave analysis wavelet

RaneNote 119 LINKWITZ-RILEY ACTIVE CROSSOVERS UP TO 8TH- ORDER: AN OVERVIEW

Application Note. Airbag Noise Measurements

Proceedings of Meetings on Acoustics

Crossover Filter Shape Comparisons A White Paper from Linea Research Paul Williams July 2013

Transcription:

Pre- and Post Ringing Of Impulse Response Source: http://zone.ni.com/reference/en-xx/help/373398b-01/svaconcepts/svtimemask/ Time (Temporal) Masking.Simultaneous masking describes the effect when the masked signal and the masking signal occur at the same time. Human hearing is sensitive to the temporal structure of sound, and masking also can occur between sounds that are not present simultaneously. Pre-masking is when the test tone occurs before the masking sound. Postmasking is when the test tone occurs after the masking sound. The following figure shows the time regions of pre-masking, simultaneous masking, and post-masking in relation to the masking signal. Figure 1. Slopes of temporal masking Post-masking is a pronounced phenomenon that corresponds to decay in the effect of the masking signal. Pre-masking is a more subtle effect caused by the fact that hearing does not occur instantaneously because sounds require some time to sense. As indicated in the figure above, researchers typically can measure premasking for only about 20 ms. Post-masking is the more dominant temporal effect and can be measured for 100 ms following the cessation of the masking sound. Both the threshold in quiet and the masked threshold depend on the duration of the test tone. Researchers must know these dependencies when investigating pre- and post-masking because they use shortduration test signals to perform these measurements.. Testing Regime Firstly, it is observable, that slopes of temporal masking in Figure 1 are plotted using lin-log scale, that is, time scale is linear in milliseconds, and level of test tone is in logarithmic scale (decibels). Since impulse responses, which we are going to examine, are typically calculated and plotted in linear scale, it is necessary to use the same vertical scale units and type dbs.

Y decibels of a variable X are expressed as: Figure 2. Y = A * log10( X ) + B where A,B are suitably chosen screen display constants. Now, in order for the slope of temporal masking display similar characteristics as on Figure 1, the X variable Figure 3. X = exp(-t / C ) + D Where T = time from T=T1 to T=T2, and C and D are suitably chosen constants. I would use expressions on Figure 2 and Figure 3 to create temporal masks if we were to display impulse responses in logarithmic scale. Calibration of the Simulation Process I do not have mathematical formulas describing pre- and post-masking slopes on Figure 1. Therefore, I had to rely on visual inspection of Figure 1 and then adjusting coefficients A,B,C and D to obtain plots of both maskers, similar to the ones on Figure 1 (green curve on Figure 2). Please note, that pre-and post masking is shown from 0dB to 50dB on the vertical scale on Figure 1. Figure 2. Calibrating Simulation Process for pure IR.

Figure 2 depicts calibration process for this simulation. 1. Impulse Response (IR) (red curve) is plotted with 10dB/div horizontal scale resolution. The IR plotted on Figure 2 was calculated from a system with a flat SPL level from within screen display limits of 10Hz-50kHz. Please note, that such system is still band-limited, but for our purpose, it is assumed flat. 2. IR of such system has a peak at 0dB level see red peak at Figure 2. The floor of IR is clipped at -140dB level. 3. IR is now calculated and shown in logarithmic scale. Also, since the IR can be negative as it wiggles along the time scale, the negative values are shown as absolute values of the IR. (in C-language: Y = 20log10(fabs(IR)) ). This is why the IR looks differently from what you would typically see in MLS systems. 4. In order to increase confidence level in the simulation, I have dropped the preand post masker levels shown on Figure 1, by -20dB. The new masker levels are now plotted in pink on Figure 2, and are extended over 70dB range. In addition, this paper extends IR of Linear-Phase (LP) and Minimum-Phase (MP) simulation into more practical area. I will also examine filter s response by creating very narrow (2 samples width) excitation pulse and bipolar pulse and feeding these pulses to both versions of the filter. From Wikipedia: http://en.wikipedia.org/wiki/impulse_response In practical systems, it is not possible to produce a perfect impulse to serve as input for testing; therefore, a brief pulse is sometimes used as an approximation of an impulse. Provided that the pulse is short enough compared to the impulse response, the result will be close to the true, theoretical, impulse response. In many systems, however, driving with a very short strong pulse may drive the system into a nonlinear regime, so instead the system is driven with a pseudo-random sequence, and the impulse response is computed from the input and output signals.. Figure 3. Calibrating Simulation for pulse and bi-polar pulse It is observable on Figure 3, that Pulse Response (PR) of the flat system is significantly improved for bi-polar Bi-Polar Response (BPR), symmetrical pulse. The tails of the BPR are at the level of -140dB (the is -70dB below already reduced pre-and-post markers).

Please note, that PR simulation approach will inject twice as much energy into the filter, and BPR will inject four times as much energy into the filter. Therefore, I would expect pre- and post ringing to be worse than for pure IR well, let s see. Modelling process will follow the procedure below: 1. Calculate linear-phase and minimum-phase impulse responses of a selected filters. 2. Align minimum-phase impulse response with the centre of linear-phase impulse response for easy comparison. 3. Compare pre- and post ringing in both filters using pre- and post masker curves. Impulse Response (IR) of Linear-Phase (LP) version is shown in red, and Minimum-Phase (MP) version is shown in green. Pre-masker and post-masker are shown in pink colour. MP version is time shifted, so that it s origin overlaps with centre of the LP version. This allows simple comparison of pre-and post ringing. Pleas also note, that FFT windowing (blue curve on all figures) has been chosen to be very wide. This is deliberate, as it improves low-frequency performance of filters, exposing more of the filter s coefficients, that are responsible for lowfrequency performance of the filter. If you choose to avoid this, you could select one of the standard windows, say Hanning type. Examination of Several Audio Filters Vented subwoofer. This situation is modelled as high-pass filter of F3dB=20Hz and slope of +24dB/oct. Figure 4. SPL of our vented subwoofer

Figure 5. LP (red) and MP (green) impulse responses. It appears, that even if this subwoofer was working as a stand-alone device, neither MP nor LP processing effects would be audible. Figure 6. PR and BPR It is clearly evident on Figure 6, that PR exhibits increased pre-ringing due to the pulse excitation being wider than the width of pure IR, but it s still acceptable. Secondly, BPR excitation results in significantly lower pre-and post ringing. This is despite four times more energy injected into the filter. This is a good news as this would possibly be more realistic signal for testing. In addition, digital artefacts (or magnitude of the coefficients) of LP filter are at -110dB level and the artefacts of MP filter are at -80dB level. This is somewhat unexpected and clear win for LP filter.

Peaking EQ filter at 100Hz and Gain = +20dB, Q=10. Figure 7. SPL of a peaking filter. Figure 8. LP (red) and MP (green) impulse responses. It is very likely, that ringing in LP filter (red) would be audible. The preringing clearly extends above the temporal pre-masker.

Figure 9. PR and BPR Interestingly, as shown on Figure 9, the PR of the MP filter version, now rises above the post-marker level. Would this be audible?. The BPR is again much lower in ringing levels for both filter versions. Notching EQ filter at 100Hz and Gain = -20dB, Q=10. Figure 10. SPL of a notch filter.

Figure 11. LP (red) and MP (green) impulse responses. It is unlikely, that ringing any in version: MP and LP would be audible. Figure 12. PR and BPR The PR and BPR are also good, and again the BPR is significantly lower in ringing.

High-Pass filter of F3dB=200Hz and slope of +48dB/oct. Figure 13. SPL of a High-Pass filter Figure 14. LP (red) and MP (green) impulse responses. It is unlikely, that ringing any version: MP and LP would be audible. The ringing is simply too short, and falls steeply, and is masked completely.

Figure 15. PR and BPR The PR and BPR are also good, and again the BPR is significantly lower in ringing. Low-Pass filter of F3dB=1000Hz and slope of -48dB/oct. Figure 16. SPL of a Low-Pass filter

Figure 17. LP (red) and MP (green) impulse responses. It is unlikely, that ringing any version: MP and LP would be audible. The ringing is simply too short, and is masked completely. Figure 18. PR and BPR The PR and BPR are also good, and again the BPR is significantly lower in ringing.

Examination of a Simple Crossover The crossover consists of a low-pass filter with -96dB/oct slope and F3dB = 100Hz, and a high-pass filter with +96dB/oct slope and F3dB = 100Hz. Figure 19. SPL of a crossover. Figure 20. LP (red) and MP (green) impulse responses (lin-lin scale). It is easily observable, that adding low-pass (red) and high-pass (green) impulse responses will result in almost perfect cancellation of pre- and post-ringing, resulting in almost perfect impulse response.

MP version (shown below) of the two filters will not add to a perfect impulse response at all. Figure 21. Impulse responses Low-Pass (red) and High-Pass (green) of a MP version of the crossover. Using Bi-Polar pulse for testing When a 2ms bi-polar pulse was used for excitation for our 20Hz, +24db/oct subwoofer, the MP version (green) has done the opposite, and converted the symmetrical bi-polar pulse into a pulse with clear asymmetrical tendency, while the LP (red) version has returned a response just about perfect excitation pulse see Figure 22 below. Figure 22. Subwoofer response to pulse and bi-polar pulse (lin-lin scale). One very important issue is observable on the Figure 22 above. The bi-polar pulse used for this simulation is much closer to real-live audio signals than a onesided, 2ms pulse (impulse). Interestingly, when compared to pulse response, we can conclude, that left-side and right-side of the LP bi-polar pulse response is

almost flat, and has lost it s pre-tilt and post-tilt, clearly visible on left-hand side of Figure 22. I have actually confirmed this issue in real measurements see Figure 23. The ringing past the pulse is due to a more distant microphone placement, so now, the mike picks some of the room reflections. Figure 23. Bi-polar pulse in LP Mode and MP Mode Please note perfect agreement between Figure 22 and the measured results above for both: MP and LP filters. I have used lin-lin scale, so that simulation model can be compared to direct CRO measurements. However, the bi-polar nature of the pulse did not change the pre-ringing of the LP version (red) of the filter. Figure 24. A 20dB peaking filter excited with a 10-sample wide bi-polar pulse.

Is Post-ringing audible at all? During my listening tests and measurements on a large, 18 subwoofer using the 2ms pulse, the minimum-phase version delivered a more of a thump instead of a pop or a click. This is perhaps not surprising, as the post-ringing of the pulse extended to130ms, far exceeded the 30ms memory effect of the auditory system, and pushed beyond the 100ms falling edge of Temporal Masker. Here, the driver, filter and vented enclosure added it s own, combined signature see Figure 25. Figure 25. 5ms Impulse in Linear-Phase Mode and Minimum-Phase Mode When a long, 10ms bi-polar pulse was used for excitation, the LP version still holds the characteristics of the excitation pulse very well, but the MP version had even more asymmetrical tendency. Figure 26. LP(red) and MP (green) responses to 10ms bipolar pulse (lin-lin scale).

Here is confirmation of the above in actual measurements. Once again, the ringing around the pulse is due to a more distant microphone placement, so now, the mike picks some of the room reflections. Figure 27.10ms Bi-polar pulse in LP Mode and MP Mode As before, an excellent agreement between simulated and measured responses is evident in Figures 26 and 27. I was able to compare a subwoofer with no acoustical phase distortions (flat line phase response) to a subwoofer with minimum-phase phase characteristics (typical phase roll-off for driver + crossover systems). There is a lack of internet literature describing this exact type of tests performed on subwoofers. The only paper I was able to source, that used phase-equalized loudspeakers (but not subwoofers) was The Audibility of Loudspeaker Phase Distortion Preprint 2927, by Mr Richard Greenfield, Dr Malcolm Hawksford, Department of Electronic Systems Engineering, University of Essex, Colchester, England. Conclusions Pre-and post ringing often come into focus in perceptual coding algorithms, as explained in http://en.wikipedia.org/wiki/pre-echo. How much does it relate to loudspeakers and crossovers?. The IR simulations presented above are my attempt to scope the pre-ringing phenomenon, as I was interested in comments coming from recording industry about audibility of linear-phase EQ pre-ringing. Upon closer research, it was almost inevitably discovered, that the phenomenon was audible under pretty extreme EQ settings. So, this little write-up is my crude attempt to shed some light at what may be contributing to the perceived EQ pre-ringing. It is acknowledged, that Temporal Masking is the mechanism responsible for what we hear in the presence of a masking signal. Some sources available on the internet will indicate, that pre-masking extends to 20ms. Like the curve on Figure 1. http://zone.ni.com/reference/en-xx/help/373398b-01/svaconcepts/svtimemask/, and other http://18.7.29.232/bitstream/handle/1721.1/36465/31317829.pdf?sequence=1 will conclude, that it is most effective from 5ms. Introduction to Digital Audio Coding

and Standards By Marina Bosi, Richard E. Goldberg, also indicates 20ms as the typical pre-masking interval. In the light of the information presented so far, the following conclusions, applicable to loudspeakers and crossovers can be drawn: Conclusion 1. Linear-Phase filters have symmetrical coefficients on both sides of the Impulse Response. Evident on all relevant Figures. Conclusion 2 Typical crossover implementation: Low-Pass and High-Pass components will cancel each other s pre-ringing, if the filters are of the same type and slope. This is illustrated on Figure 20. Conclusion 3 All pre-ringing artefacts, that fall into the interval of 20ms prior to the onset of the masker (and most effectively from 5ms) will not be audible due to pre-masking effect. Examples are illustrated on Figure 14 and 17. Conclusion 4 Pre-ringing is most evident (and audible) while using peaking filters with high gain and high Q-factor, as illustrated on Figure 8 and Figure 24, and suggested by the recording industry. These should be avoided. On the other hand, notch filters are OK to use (as in RoomEQ), as illustrated on Figure 11 and 12. Conclusion 5 Typical sounds do not have purely one-sided, pulsing nature. They tend to have more of a bi-polar attack transient envelope. In this department, LP subwoofer (or system) will outperform MP subwoofer, as evident from Figure 22 and confirmed in actual measurements on Figure 23. Also Figures 26 and 27. Listening tests conducted on phase-linear loudspeaker (AES Preprint 2927) by Mr Richard Greenfield, Dr Malcolm Hawksford and several other expert listeners also did not reveal any pre-response issues. Example of similar comments are here: http://tech.groups.yahoo.com/group/soundeasyuserslist/message/4965 So, the overall conclusion from the above simulation is that, the possible audibility of the pre-ringing artefacts of Linear-Phase approach to loudspeaker design does not seem to be an issue with typical loudspeaker or crossover filter. I have been using my THX-level, Linear-Phase 5.2HT audio system for over 6 months, listening to a variety of CD/server music and watching concerts/movies in Blu-ray format. http://www.bodziosoftware.com.au/home_theatre_conclusions.pdf No problems were observed (or heard). Thank you for reading, Bohdan