BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting. https://www.gigahertz-optik.de/en-us/product/bts256-par

Similar documents
BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

LED Tester BTS256-LED

BTS2048-VL-CP-ILED-B-IS-1.0-HL

LED Tester BTS256-LED

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

Spectroradiometer specbos 1201

Broadbandradiometer specbos 1211

Miniaturized Spectroradiometer

GL spectis 1.0 Touch The world s first smart spectrometer.

MK350 Portable Spectrometer

HD HD HD AND HD PHOTO-RADIOMETERS LG-2

Fully Portable Spectrophotometer for Transmission Measurement

Illuminance Meter. series

LI-192 Underwater Quantum Sensor

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application >

Chameleon Spectroradiometer

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

LED Lighting Flux and Color Measurement System (LFC)

We bring quality to light. MAS 40 Mini-Array Spectrometer

Radiometric and Photometric Measurements with TAOS PhotoSensors

Konica Minolta LS-110 Specs Provided by

LI-193 Spherical Quantum Sensor

GL SPECTIS 1.0 Touch The world s first smart spectrometer

Photometry for Traffic Engineers...

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

Chroma Meter CL-200A. Even measures new light sources such as LED lighting and organic EL lighting

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

illumia Plus Temperature Controlled Light Measurement Systems

Spectral Handheld Light Meters for accurate measurements of LED lighting. Mike Clark, Gigahertz-Optik GmbH on behalf of Te Lintelo Systems BV

LP PHOT 03 LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03

JETI Specbos Instruments

Spectral Light Meters for accurate measurements of LED lighting Mike Clark, Gigahertz-Optik GmbH

Spectral Photometry BASE

PRODUCTION DATA SHEET

operating manual iliad for Windows & Mac OS X software application rc81

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Luminous Flux (lumens) System LM-ISP-XXXX

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

Photometry and Light Measurement

LI-1500 Light Sensor Logger

We bring quality to light. CAS 120 CCD Array Spectrometer

Solid State Luminance Standards

CS-2000/2000A. Spectroradiometer NEW

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

There are many types of light sources, ranging from natural sunlight to man-made artificial lightings.

20W TL 324 smd LED Warm White by Simplify-It

We bring quality to light. CAS 140CT Array Spectrometer

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

Microscope-Spectrometer

OPB780-Kit. Color Sensor Evaluation Kit

ILLUMINANCE METER LUMINANCE METER CHROMA METER T-10A /T-10MA/ T-10WSA/T-10WLA CL-200A CL-500A LS-100/LS-110 CS-100A CS-200

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Model S471-LED Optometer

Photometry for Traffic Engineers...

Visibility, Performance and Perception. Cooper Lighting

LED T5 30cm Warm White by BS Ledlight

CIE 220:2016 Characterization and Calibration Method of UV Radiometers

Color Sensing using the OPB780

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

specification display & lighting hera spectrometer

Optometers & Instruments - Page 3

LGS Goniophotometer. Two Global Leaders. One Complete Solution.

The Standard for over 40 Years

Company synopsis. MSU series

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

Led Spot MR16 10W Cold White by CDE Technology BV

LED Lighting - Error Consideration for Illuminance Measurement

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

Achieving 100,000 : 1 contrast measurement

UV Measurement. Information Sheet. Dipl.-Ing. Andreas Renzel. Basics of UV measurement and solutions for UV curing applications.

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

Led 12V 3W Spot Light GU5.3 by Tuono Lighting

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

LEDView LIGHTING CABINET. User Manual

Manual DATALOGGING LIGHT METER - PCE-174

BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane)

High Illuminance Calibration Facility and Procedures

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

11/14/2016. Exponation AIA Provider Number: Learning Objectives. Course Description. Meters, Metrics and Visual Perception LEDSSMW16-S#1

INTERFEROMETER VI-direct

Content Spectrophotometers

A Fast Dynamics and PWM-Dimmable LED Driver for Accurate Control of Illumination in Plants Physiology Experiments

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

Basic lighting quantities

LED14.5WPAR30S/FL/827-DIM

Imaging Photometer and Colorimeter

Lamp measurement report - 13 May 2012 Led TL 120 cm 18W 6500K by Prolumia

Led Spot MR16 10W Neutral White with 700 ma constant current driver by CDE Technology BV

Transcription:

BTS256-PAR https://www.gigahertz-optik.de/en-us/product/bts256-par Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting Gigahertz-Optik GmbH 1/8

Description Measurement and examination of the photosynthetically active radiation, R/FR, DLI, illuminance, luminous color, color rendering index, scotopic to photopic ratio, EVE factor, spectrum of LEDs and other lights The BTS256-PAR is a high-quality light meter that is well suited for illuminance and luminous color measurements in all application areas thanks to its compact design, high-quality light sensor and precise cosine field of view function. Light meter with a precise cosine field of view function BiTec light sensor for precise light measurements One of the outstanding properties of this mobile light meter is its BiTec light sensor. This combines the characteristic properties of a silicon photodiode with those of a low-noise CMOS diode array. The BiTec sensor guarantees precise photometric and spectral-radiometric measurement values over a large dynamic range through mutual correction of the measurement signals of both sensors. Silicon photodiode detector, fast and linear When taking into account the dynamic range, linearity and speed, silicon photodiodes have always been and are still the ultimate light detectors. A photometric corrected silicon photodiode is therefore incorporated in the BiTec light sensor of the BTS256-PAR light meter. Its matching to the photometric V(λ) responsivity is improved by the diode array s spectral measurement data. R/FR ratio User specific weigthing function It is possible to use up to five user specific weigthing functions within the device for custom calculations. These functions can be transmitted by the S-BTS256 software and are saved in the device. Diode array detector for spectral measurement data The CMOS diode array of the BiTec Light sensor provides precise measurement data required for the luminous spectrum. This data is then used for calculation of the color values and scotopic illuminance as well as for optimization of the photometric responsivity. Optimized Signal to Noise Ratio The noise signal from diode array detectors has significant effect on the signal to noise ratio (SNR) and hence on the quality of the measurement signal as well. A remote controlled shutter in the BiTec light sensor enables online compensation of the dark signals that are dependent on the temperature and integration time. DLI measurement Pulse Width Modulated (PWM) LED lamps The fast photodiode of the BiTec light sensor enables the BTS256-PAR to automatically synchronize itself to the frequency of lamps operated in PWM mode. Precise cosine corrected field of view A cosine corrected field of view is absolutely necessary for illuminance measurement devices. For extended illuminance setups, the cosine matching has significant influence on the measurement uncertainty of the light meter. The BTS256-PAR light meter is equipped with a diffuser window with a 20mm diameter whose cosine matching ensures an f2 3% uncertainty which corresponds to the DIN 5036 requirements for the quality class B. Both detectors of the BiTec light sensor are centrally aligned behind the diffuser window and therefore have the same view angle. DIN quality class A and B luxmeter Standard display for the illuminance and spectrum Through the cutting-edge Bi-Technology sensor concept, use of modern electronics, online dark signal adjustment and the possibility to perform temperature compensation, the device Gigahertz-Optik GmbH 2/8

meets the conditions specified for two of the DIN 5036 quality classes. In terms of the f2 uncertainty i.e. 3%, the device corresponds to the quality class B (DIN 5032 section 7). In applications where limitation of the viewing angle is acceptable, the BTS256-PAR, with its f1, u, f3 and f4 values, corresponds to the quality class A (DIN 5032 section 7). Diverse photometric and colorimetric measurands A much broader diversity of measurands as the one offered by conventional light meters is required for verification and testing of LED lamps. The BTS256-PAR offers fourteen measurands and thereby meets all the requirements for a modern light meter: Ep photopic illuminance Es scotopic illuminance DLI (Daily Light Integral ) R/FR Red to Far-Red relationship Qsy' PAR value PAR PPFD in µmol/(m²s) Esy1, Esy2, Etp1, Etp2 in W/m² UWF User Weigthing Function (5 different user function are possible) Es/Ep ratio of night and daylight vision EVE Equivalent Visual Efficiency factor Ee irradiance Eλ spectral irradiance x, y CIE 1931 color coordinates u, v CIE 1976 color coordinates CT color temperature Δuv Deviation from the blackbody locus λdom dominant wavelength λp peak intensity wavelength λ0,5 spectral half-width Purity color purity CRI Ra and R1 to R15 Color Rendering Index Ratio of the scotopic and photopic illuminance with the EVE factor as per IES TM-24-13 Display modes for standard measurements The BTS256-PAR Bi-Tec sensor luxmeter has several display modes where the necessary measurands for the common photometric measurements are incorporated. The cursor buttons can be used to switch between the displays. Customized display modes The BTS256-PAR enables users to individually configure and save display modes. The required measurands can hereby be selected. Info display for measurement parameters An incorporated Info Display shows all the relevant measurement parameters. Easy operation and handling Three control buttons and the diligently structured menu navigation make the device easy and safe to operate the device. For instance, in the standard measurement mode, the user does not have to manually set the measurement parameters since these are automatically and best adjusted to match the measurement conditions. In the expert mode, the user has access to all measurement parameters. Many useful extra functions If the user wants to distance himself from the device s field of view, he/she can set a time-delayed measurement. The display can automatically be dimmed during the measurement. An acoustic signal can be set to mark the end of a measurement. A layout created using a PC with the support points for the single measurements can be adopted in the device for measurement of the illuminance distribution. The measurement points can be progressively processed and saved. Fast data logger measurement mode where time-clocked readings of the photodiode can be recorded at a maximum measurement rate of up to 100ms. A second data logger measurement mode that enables time-clocked recording of all measurands including the spectral measurement data. Date and time in real-time can also be set. Tripod mount The measurement device has a tripod stand socket on the bottom side. Gigahertz-Optik GmbH 3/8

Protective cap with chain The protective cap for the diffuser window is attached onto the device. Use without PC The BTS256-PAR has all the necessary functions enabling free operation of the device without having to depend on a computer. Furthermore, the rechargeable batteries have a capacity of more than 8 operation hours. The USB power adapter enables recharging of the device without a PC. The measurement parameters protocol is saved together with a measurement data file Use with PC The BTS256-PAR additionally has a USB 2.0 interface for use with a PC. This enables both data exchange and battery charging. User software The S-BTS256 software included in the device s price provides all the necessary functions for the measurements, measurement data display and data transfer. The cutting-edge, flexible desktop concept of the software offers the user an individual constellation of the required measurement values. This can be a full screen filled with lux measurement values or a matrix with both numerical and graphical fields. Each desktop constellation can easily be saved for future use. Software Development Kit Gigahertz-Optik offers programmers the S-SDK-BTS256 Software Development Tool. This can be used with LabView from National Instruments,.NET from Microsoft and C/C++. The SDKs simplify integration of the BTS256-PAR in an internally developed software. Standard display with illuminance, x,y color coordinates, color temperature and emission spectrum of an energy saving lamp S-BTS256 user software with modular setup desktop The graphical display module can be zoomed Specifications General Lightmeter class B DIN 5032 part 7 or AA according to JIS C 1609-1:2006 class A DIN 5032 part 7 for f1, u, f3 and f4 or general precision class according to JIS C 1609-1:2006 Light sensor Bi-Technology sensor with a photometric broadband detector and a array spectrometer. Integrated aperture for automatic dark signal adjustment. Gigahertz-Optik GmbH 4/8

Input optic Diffuser window with 20mm diameter, cosine corrected field of view, f2 3 % Calibration uncertainty Illuminance +/-2.2% Weighting functions Additionally five different user specific weighting functions can be saved in the device. additional Measurands (to BTS256-E) PAR - µmol/(m²s) DLI - Daily Light Integral (time resolved measured with the help of a data logger) R/FR - Red to Far Red ratio Esy1, Esy2, Etp1, Etp2 weighting functions 5 different user specific weighting functions Spectral Detector Chip Wavelength Range Optical Bandwidth Data Resolution Integration Time Shutter CMOS diode-array (380-750) nm 10 nm 1 nm (5.2-30000) ms Automatic aperture for dark signal measurements with the same integration time as that of light measurements. Aperture delay = 100ms. Gigahertz-Optik GmbH 5/8

Typ. Measurement Time 199,999 lx 5ms (white light) 100 lx 1s (white light) Color measurement range spectral PAR measurement range Scotopic (1-199,999) lx (white light) (0.1-20000) µmol/(m²s) (white light) Scotopic measurement range spectral (1-199,999) lx Calibration uncertainty of scotopic Illuminance +/-2.2% Peak wavelength Dominant wavelength +/- 1nm +/- 1nm Δx, Δy reproducibility +/- 0.0001 (Standard illuminant type A) +/- 0.0002 (LED) Δx, Δy uncertainty +/- 0.002 (Standard illuminant type A) +/- 0.005 (typ. LED) CCT Measurement range (1700-17000) K ΔCCT +/- 50K (standard illuminant type A) +/- 4% (depending on the LED spectrum) CRI (color rendering index) Stray Light Ra and R1 to R15 6E-4 (Blue LED) 6E-4 (Green LED) 6E-4 (Red LED) 1E-3 (White LED) Calibration uncertainty Spectral irradiance (380-399) nm: +/- 7 % (400-750) nm: +/- 4 % Spectral irradiance responsivity (380-750) nm Integral Detector Filter f1' Spectral responsivity with fine CIE photometric matching. Online correction of the photometric matching through spectral measurement data (spectral missmatch factor correction) 6% (uncorrected) 3% (f1' a*(s z (λ)) respectively F*(s z (λ)) corrected by spectral data, done automatically by BTS technology) Max. measurable illuminance Noise equivalent illuminance Resolution Measurement Time 199,999 lx 0.01lx 12Bit (0.1-6000) ms Graphs Gigahertz-Optik GmbH 6/8

spectral irradiance responsivity f2 uncertainty Miscellaneous Microprocessor Charging voltage Interface 16Bit, 25ns instruction cycle time 5VDC, 450mA per USB USB 2.0 (Type B USB-Port) Option WiFi: WiFi 2,4 GHz (external antenna, range > 100m) Temperature Operation: -10 C bis +30 C Storage: -10 C to +50 C Dimensions Weight 159mm x 85mm x 45mm (Length x Width x Height) 500g Gigahertz-Optik GmbH 7/8

Powered by TCPDF (www.tcpdf.org) hard-top casing 333mm x 280mm x 70mm 650g Configurable with Produktname Product Image Description Show product S-SDK-BTS256 Software Development Kit for BTS256 variants. https://www.gigahertzoptik.de/en-us/produc t/s-sdk-bts256 S-BTS256 Application software for BTS256 variants. https://www.gigahertzoptik.de/enus/product/s-bts256 Purchasing information Article-Nr Modell Description Product 15298452 BTS256-PAR measurement device, USB cabel, hard case, manual, S-BTS256 software, calibration certificate. 15298453 BTS256-PAR WiFi measurement device, USB cable, hard case, manual, S-BTS256 Software, calibration certificate. Re-calibration 15300751 K-BTS256-E-I BTS256-PAR Re-Calibration with calibration certificate. Accessories 15298218 S-SDK-BTS256 Software Development Kit; Software and users guide on CD. Gigahertz-Optik GmbH 8/8