DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd

Similar documents
IRT Eurocard. Type DAC AES / 2Mb (E1) G.703 Network Interface Adapter

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

IRT Eurocard. Types DDA 4301 E3 / DS3 G.703 Data Distribution Amplifiers & ZDA 4300RH Handshake Changeover Assembly

IRT Eurocard. Type AG-738. Stereo Audio Phase / Failure Detector

IRT Eurocard. Type DDA Mbits/s Data Distribution Amplifier. Telstra Serial Item Numbers 347/93 DDA /94 Operations Manual - DDA-3100



User Manual DTR Multi-Channel 3G/HD/SD/ASI + Gigabit Ethernet Fibre Optic Link. Revision 00

PI-10 Broadband Power Indicator

PI-150 Broadband Power Indicator

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

A 500 Broadband Power Amplifier

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

3100LA Broadband Power Amplifier

Opus 21 s80 Integrated Amplifier Owner's Manual

Owner s manual. SDA 2175 Semi Digital Amplifier

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

AMU-214 Auxiliary Monitor Unit Operations Manual

2100L Broadband Power Amplifier

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

4 Channel Frequency Conscious Noise Gate. Operation Manual

Owner s Manual Rev 2.0

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

AD-8100 & AD-8200 Servo Amplifiers

411LA Broadband Power Amplifier

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

1140LA Broadband Power Amplifier

PDB4. Four Channel Passive Direct Box USER'S GUIDE

EPA152/252/502. User Manual.

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

1160 Stereo Power Amplifier

User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

A Series Professional Power Amplifiers

H A 6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL

Active UTP Transceiver Hub Installation Guide

CX-A6 Amplifier Installation & User Guide V9.0

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

KeyPre KP6 - Electronic Instrument Preamplifier

AV30MX-2 Operation Manual

EPA104/254. User Manual.

Telex. User Instructions. Model SPS2000A Power Supply Audiocom Intercom Systems SPS2000A. Volume RESET

PCX-7401 Pulsed Current Source Operation Manual

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

Instruction Manual Model 4116-T51 Multi-Band Translator

SR3400 Base Station Module Configuration and Use Series-2 Cards Only

CX-A6 Amplifier Installation & User Guide V8.0

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

Installation and Operation Manual EVTM Stand-alone Encoder/Decoder

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

TMP40. User Manual.

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

System Power Amplifier (SPA)

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014

Digital Microwave Radios

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Continuous Wave Fiber Laser User Guide

MODEL W Power Amplifier

M302RM OPERATING MANUAL

Instruction Manual Model Ka-Band Block Upconverter

5000 Series Receiver Systems


COUPLING DECOUPLING NETWORK MODEL CDN-AF4

EPSILON SWITCH & AMPLIFIER SYSTEM SAS-E MODEL SAS17E & SAS36E. User s Manual. spectracom.com

SPECIAL SPECIFICATION 1257 Digital Card Rack Non-Invasive Micro Loop Detector Assembly (8 Slot Rack)

Broadband Power Amplifier

MSE M A G N E T I C S O U N D E N H A C E R. Passion

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

Model A Milliohm Resistance Tester Operators Manual

UP-67M4, UP-127M4, UP-247M2, UP-487

Model 9302 Amplifier-Discriminator Operating and Service Manual

InfraStruXure Manager v4.x Addendum: Building Management System Integration

Earth Fault Indicator EFI-BLZ-50 User Manual

20 CHANNELS DIGITAL DELAY GENERATOR

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

Model MHz Arbitrary Waveform / Function Generator

CANARY AUDIO. Power Amplifier CA-309 OWNER S MANUAL. Handcrafted in California MADE IN USA

Model NV-ER1808i TBus Eight Port Receiver Hub

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

British Audio Engineering

HTA125A/250A. Power Amplifiers. Installation & Use Manual

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

AV Series AV-25-2 AV-25 Owner s Manual February 2010

Installation and Operation Manual

Model 1791 VHF Radio User's Manual

Model NV-ER1816i TBus Sixteen Port Receiver Hub

Instruction Manual Model

BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

OM7AT & OM7AR1 (Stand alone) ROM7AT & ROM7AR1 (Rack mount)

CM /100/1000BASE-T

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

Transcription:

AES/EBU Digital Audio Distribution Amplifier User Manual Revision 02

AES/EBU DIGITAL AUDIO DISTRIBUTION AMPLIFIER Revision History: Revision Date By Change Description Applicable to: 00 15/03/2005 AL Original Issue. Serial numbers > 0406001 01 29/01/2010 AL Front panel layout changed and AES sample rate corrected. Serial numbers > 0406001 02 08/06/2016 AL Upgraded to I.R.T. Communications company name. Serial numbers > 0406001 Page 2 of 14 Revision 02

USER MANUAL Table of Contents: Section Page Revision History 2 Operational Safety 4 General Description 5 Technical Specifications 6 Configuration 7 Installation 8 Signal Connections 8 SMU-4000 Installation 9 Figure 1: SMU-4000 module 9 Front and Rear Layouts 10 SNMP What Is It? 11 SNMP Functions 13 Maintenance & Storage 14 Warranty & Service 14 This instruction book applies to serial numbers > 0406001 Page 3 of 14 Revision 02

OPERATIONAL SAFETY WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life. Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position. Maintenance personnel should observe all safety regulations. Do not make any adjustments inside equipment with power ON unless proper precautions are observed. All internal adjustments should only be made by suitably qualified personnel. All operational adjustments are available externally without the need for removing covers or use of extender cards. Page 4 of 14 Revision 02

GENERAL DESCRIPTION BLOCK DIAGRAM SIGNAL PATH 75 Ohm 110 Ohm 8 x 75 Ohm or SNMP 110 Ohm The is designed to provide a solution to most AES/EBU digital audio signal distribution requirements. The will operate at AES sample rates from 34 to 54 khz and may be used with non-aes digital signals that have a net zero DC content. Whilst analogue VDA's may be used for 75 Ohm AES signals, the digital circuitry of the offers the advantage of restoring the signal rise and fall times and output level without the need to manually adjust gain and compensation controls. A choice of rear assembly is available for either 110 Ohm or 75 Ohm use. No changes are required to the main DA to convert between the two output types. The input includes both 110 Ohm and 75 Ohm input connectors and is link selectable on the main PCB. An optional SNMP (Simple Network Management Protocol) plug-in module is available for monitoring when used in an IRT frame fitted with SNMP capability. The is designed to fit IRT s standard 1RU and 3RU Eurocard frames and may be used alongside any other of IRT s analogue or digital Eurocards. Standard features: 8 outputs. 75 and 110 Ohm inputs. Choice of 75 or 110 Ohm outputs by changing rear connector assembly. Front panel monitoring output. All inputs and outputs transformer coupled. Digital circuit re-shapes output and restores level. No cable compensation adjustments required. Optional plug-in SNMP monitoring module. Page 5 of 14 Revision 02

TECHNICAL SPECIFICATIONS Inputs: Number 2. Type 1 x 110 Ω balanced; or 1 x 75 Ω unbalanced. Selected by link on PCB. Format AES3-1992 standard. Input level 200 mvp-p minimum. Cable length > 500 m 75 Ω (Belden 8281). > 200 m 110 Ω (AES digital high quality shielded pair). Outputs: Number 8. Type ZAA-4401 (standard) 110 Ω balanced > 3 Vp-p; or ZAA-4400 (optional) 75 Ω unbalanced > 1 Vp-p. Monitoring 1 x 75 Ω unbalanced. Format AES3-1992 standard. Performance: AES sample rate Rise & fall times Power requirements: Voltage Power consumption Connectors: Balanced Unbalanced 34 to 54 khz continuous. < 20 ns. 28 Vac CT (14-0-14) or ± 16 Vdc. < 4 VA. Phoenix 3 terminal plug-in blocks. BNC. Other: Temperature range 0-50 C ambient. Mechanical Suitable for mounting in IRT 19" rack chassis with input, output and power connections on the rear panel. Finish Front panel Grey background, black lettering & red IRT logo. Rear assembly Detachable silk-screened PCB with direct mount connectors to Eurocard and external signals. Dimensions 6 HP x 3 U x 220 mm IRT Eurocard. Supplied accessories Optional accessories Rear connector assembly including matching plugs for 110 Ohm connections. SMU-4000 plug in SNMP Management Information Base (MIB) module. Due to our policy of continuing development, these specifications are subject to change without notice. Page 6 of 14 Revision 02

CONFIGURATION Other than the following link settings, there are no user configurable settings. All other potentiometer and link settings are factory set and should not be moved. Input Impedance: The AES/EBU input can be set for either 110 Ω balanced (3 pin phoenix connector ) or 75 Ω unbalanced (BNC), regardless of rear assembly chosen. On board link settings (both SW1 and SW2) need to be set for either 110 Ω balanced terminating or 75 Ω unbalanced terminating depending on the input connector chosen. I/P SELECT 75-110 SW1 SW2 Output Impedance: Output impedance is determined by the choice of rear assembly. The is generally supplied standard with the ZAA-4401 110 Ω balanced output rear assembly. The ZAA-4400 75 Ω unbalanced output rear assembly is available at time of ordering. Both rear assemblies take either balanced or unbalanced inputs. Page 7 of 14 Revision 02

INSTALLATION Pre-installation: Handling: This equipment may contain or be connected to static sensitive devices and proper static free handling precautions should be observed. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags. Power: AC mains supply: Ensure that operating voltage of unit and local supply voltage match and that correct rating fuse is installed for local supply. DC supply: Ensure that the correct polarity is observed and that DC supply voltage is maintained within the operating range specified. Earthing: The earth path is dependent on the type of frame selected. In every case particular care should be taken to ensure that the frame is connected to earth for safety reasons. See frame manual for details. Signal earth: For safety reasons a connection is made between signal earth and chassis earth. No attempt should be made to break this connection. Installation in frame or chassis: See details in separate manual for selected frame type. Signal Connections: Signal connections are made to the connectors on the selected rear panel of the. The input signal can be either 75 ohms unbalanced terminating or 110 ohms balanced terminating, the input selection is done be links SW1, SW2 on the module pcb near pin 32 of the input connector. Move the links provided to the 75 or 110 positions marked on the board as required. The input signal is then connected to the appropriate input connector on the rear panel. For unbalanced 75 Ω output circuits use the ZAA-4400 rear panel and for balanced 110 Ω output circuits use the ZAA-4401 rear panel assembly. The presence of signal at the output of the rear assembly can be monitored using the front panel monitoring BNC socket provided. Page 8 of 14 Revision 02

SMU-4000 Installation The SMU-4000 plug-in SNMP management controller module can only be fitted to IRT s 4000 series modules that are capable of being SNMP upgradeable. To determine whether a module is SNMP upgradeable, a square section on the main PCB is silk screened and fitted with three multipin sockets as shown below: 1J1 1J3 1J2 This is where the SMU-4000 plug-in SNMP management controller module is fitted. The three sets of multipins on the underside of the SMU-4000 line up with the three sets of multipin sockets on the main PCB module. Align all pins and then gently press the SMU-4000 all the way down into place. If the SMU-4000 is not already programmed with the correct firmware to match the module that it is being plugged into, it then needs to be programmed via the pins on the topside of the SMU-4000. Note that installation will generally be done by I.R.T. Communications at the time of ordering. Note also that an SMU-4000 will only be functionally operational when the main module that it is plugged into is fitted into an IRT SNMP capable frame fitted with a CDM-xxxx SNMP agent and being interrogated by a suitable Network Management System. Figure 1: SMU-4000 module Page 9 of 14 Revision 02

Front & rear panel connector diagrams ZAA-4400 Rear Assembly (Un-Balanced O/P s) (Optional) ZAA-4401 Rear Assembly (Balanced O/P s) (Standard) Page 10 of 14 Revision 02

SNMP What Is It? SNMP stands for Simple Network Management Protocol. It is an application layer protocol for managing IP (Internet Protocol) based systems. SNMP enables system administrators to manage system performance, and to find and solve system problems. SNMP runs over UDP (User Datagram Protocol), which in turn runs over IP. Three types of SNMP exist: SNMP version 1 (SNMPv1), SNMP version 2 (SNMPv2) and SNMP version 3 (SNMPv3). It is not the intention here to discuss the differences between various versions, only to bring attention to the fact that IRT modules, fitted with SNMP capability, use SNMPv1. An SNMP managed network consists of three key components: Network Management Systems (NMS), agents, and managed devices. An NMS is the console through which the network administrator performs network management functions, such as monitoring status (e.g. alarm states) and remote controlling, of a set of managed devices. One or more NMS s must exist on any managed network. Generally the NMS is a computer running third party SNMP control software. There are a number of third party SNMP software applications currently available on the market. An NMS polls, or communicates with, an agent. An agent is a network management software module that resides in a managed device. An agent has local knowledge of management information and translates that information into a form compatible with SNMP. The agent, therefore, acts as an interface between the NMS and the managed devices. The NMS sends a request message, and control commands for the managed devices, to the agent, which in turn sends a response message, containing information about the managed devices, back to the NMS. A managed device contains an SNMP agent and resides on a managed network. Managed devices collect and store management information and make this information available to NMS s using SNMP. Managed device agent variables are organised in a tree structure known as a Management Information Base (MIB). Within the MIB are parameters pertaining to the managed device. An Object Identifier (OID) number within the MIB defines the managed device type. This is a unique number specific to the model of managed device. Other information relating to the device is also stored, information such as alarm states, controllable settings, etc. The MIB tree is organised in such a way that there will be no two MIB files with conflicting placements. Normally an NMS polls an agent for information relating to the MIB in a managed device to be sent back to the NMS. When certain conditions are met within the MIB, such as major alarm conditions, for example, the agent automatically sends what is known as a trap to the NMS without any prompting from the NMS. This allows automatic notification of a predetermined event. SNMP Block Diagram NMS SNMP Agent Protocol Engine MIB SNMP Agent IP Network SNMP Agent Protocol Engine MIB SNMP Agent NMS SNMP Agent Protocol Engine MIB SNMP Agent Page 11 of 14 Revision 02

SNMP with IRT Products: I.R.T. Communications currently employs SNMPv1 with its SNMP capable frames. The frame acts as an agent when fitted with a CDM-xxxx module. This module has its own designated slot next to the power supply so as to not affect the number of modules that the frame will take. Communication between the NMS, the frame and its loaded modules are via this CDM-xxxx module. Note that the NMS software is third party and not supplied by I.R.T. Communications. Ethernet connection for SNMP operation is via an RJ45 connector on the rear of the frame, below the mains inlet. Ethernet rate runs at either 10 baset or 100 baset. Frame parameters, such as Name, Address and Location, are set via an RS232 interface, a D9 connector on the rear of the frame below the mains inlet. A software terminal emulator, such as Tera Term or HyperTerminal, is used for setting and reading the parameters of the frame. IRT modules that are SNMP compatible may need an optional plug-in SNMP module with a program relevant to the module that it is plugged into. Depending on the module, besides the module identification, parameters such as alarm states, inputs and controls etc. are communicated to the CDM-xxxx agent via a data bus on the rear of the frame. Thus the CDM-xxxx collects information on what is loaded within the frame, what positions they occupy, and their current status for communication to the NMS when the NMS sends a request for information. In the event of a major alarm from any of the SNMP compatible modules, or power supplies, a trap is automatically sent by the CDM-xxxx agent to the NMS without any prompting by the NMS. This alerts the operator to any fault conditions that may exist that need immediate attention. FRU-4000 110/240 V 50/60 Hz FRAME 0.7 A (max.) FUSES 220/240 Vac 500 ma S.B. 110/120 Vac 1A S.B. RS232 Ethernet Alarm + - 48Vdc AS3260 approval no.: CS6346N Ass. no.: 804692 IRT SNMP Connections IRT modules fitted with SMU-4000 CDM-xxxx PSU s NMS Ethernet Cable IP Network Ethernet Cable IRT SNMP Frame IRT modules fitted with SMU-4000 CDM-xxxx PSU s IRT SNMP Frame IRT SNMP Setup Ethernet Cable Page 12 of 14 Revision 02

SNMP Functions: With the fitted with the optional plug-in SMU-4000 SNMP module, programmed with the firmware to suit, and installed in an IRT 4000 series frame with SNMP capability, can be interrogated by an SNMP Network Management System (NMS). The following SNMP functions are capable of being monitored by an NMS: sysdescr sysuptime sysname irt4400alarms irt4400inputpresent irt4400reset irt4400trap - A description of the unit: AES Distribution Amplifier. - A indication of how long the unit has been running since its last power on or reset in Days, Hours, Minutes and Seconds. - A 16 character writable system name. Default set name: DDA-4010. - An indication of the current state of the alarm state: (1) noalarms: No alarms present. (2) urgentalarms: Input is absent or invalid. - An indication that the input signal is present: (1) notpresent: No input signal is present. (2) present: Input signal is present. - Unit reset control: (1) normal: when queried reset control returns a normal state. (2) reset: system reset causes card to reload its firmware. - Enable or Disable Traps to be sent when the input status condition changes: (1) onalarm: TRAP sent on change of input alarm status. (2) disabled: Automatic TRAP generation disabled. Page 13 of 14 Revision 02

MAINTENANCE & STORAGE Maintenance: No regular maintenance is required. Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind. This is especially important in fibre optic equipment where cleanliness of optical connections is critical to performance. Storage: If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags. WARRANTY & SERVICE Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply. For situations when No Fault Found for repairs, a minimum charge of 1 hour s labour, at IRT s current labour charge rate, will apply, whether the equipment is within the warranty period or not. Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier. Equipment return: Before arranging service, ensure that the fault is in the unit to be serviced and not in associated equipment. If possible, confirm this by substitution. Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair. The equipment should be properly packed for return observing antistatic procedures. The following information should accompany the unit to be returned: 1. A fault report should be included indicating the nature of the fault 2. The operating conditions under which the fault initially occurred. 3. Any additional information, which may be of assistance in fault location and remedy. 4. A contact name and telephone and fax numbers. 5. Details of payment method for items not covered by warranty. 6. Full return address. 7. For situations when No Fault Found for repairs, a minimum charge of 1 hour s labour will apply, whether the equipment is within the warranty period or not. Contact IRT for current hourly rate. Please note that all freight charges are the responsibility of the customer. The equipment should be returned to the agent who originally supplied the equipment or, where this is not possible, to IRT directly. Details of IRT s direct address can be found at I.R.T. Communications website. Web address: www.irtcommunications.com Email: sales@irtcommunications.com Page 14 of 14 Revision 02