Single phase meter with direct connection and pulse or Modbus RS485 output

Similar documents
3-phase meter with direct connection and pulse or Modbus RS485 output

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

(1,5 modules per pole)

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Analyzer Type EM112

Energy Management Energy Analyzer Type EM111

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Analyzer Type EM210 MID

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

Energy Management Energy Meter Type EM340

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

EM-72 Electricity Meters for Current Transformers

Moeller Electric Corporation

PEM353. Universal measuring device

Energy Management Energy Meter Type EM110

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Energy Management Energy Analyzer Type EM210

3 phase energy meters with integrated Serial Modbus interface

Power Meter Series PM9

Power Quality and Energy Measurement PEM533

Energy Management Energy Meter Type EM110

Centrale de mesure Power Meter PM500 Merlin Gerin

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

sustainable savings that can be viewed directly on the internet

Power Quality and Energy Measurement PEM735

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

Introduction DIN rail mounted electricity meters

Power Quality and Energy Measurement PEM575

RCMS460 and RCMS490 Series

Power Meter Series PM3200 Functions and characteristics

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

DIN Rail Kilowatt Hour Energy Meters

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Electronic timer CT-MFS.21

Electronic timer CT-SDS.22

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Single phase energy meter with Serial Modbus interface

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

Energy Management Energy Analyzer Type EM280-72D

Energy Management Energy Analyzer Type EM270-72D

Power Quality and Energy Measurement PEM330/PEM333

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

Theta 20A / 20V. Technical Data Sheet. Special Features

B850 Boiler House Energy Monitor

ISOMETER IRDH575. Approvals

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Power Quality and Energy Measurement PEM575

Type Nominal voltage (V) Code HSV V

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Protection components

Electronic timer CT-TGD.22

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

90 ReStart AUTOMATIC RECLOSING DEVICES

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ND40 - POWER NETWORK ANALYZER /RECORDER

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Side view View from below Rear view

Energy Management Energy Meter GM3D

02/11/2015

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

27/04/2015

Power-meters three-phase

Transcription:

87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning... 2 5. General characteristics... 3 6. Compliance... 5 7. Communication... 5 0 046 81 0 046 72/77 1. DESCRIPTION - USAGE Active energy meter. Measures the electricity consumed by a single phase circuit downstream of the power distribution metering. Displays electricity consumption in kwh. 3. DIMENSIONS (continued). 046 81 2. RANGE. Cat. No. 0 046 72: 2-module single phase pulse output meter. Cat. No. 0 046 77: 2-module single phase RS485 output meter. Cat. No. 0 046 81: 2-module single phase pulse output meter Nominal ratings:. Basic current: Ib 10 A. Imax maximum current: 36 A (Cat. No. 046 81). 63 A (Cat. No(s). 046 72 / 77) Nominal voltage and frequency:. Un: 230 V ± 20%. Fn: 50-60 Hz ± 5% 3. DIMENSIONS. 046 72 / 77 1 / 5

4. POSITIONING - CONNECTION Mounting:. On IEC/EN 60715 symmetrical rail Operating positions:. Vertical, horizontal, upside down, on the side 4. POSITIONING CONNECTION (continued) Terminal protection:. The power and communication terminals are protected with sealable terminal shields integrated in the device box (Cat. No(s). 04672 / 77 only). Power terminals:. Terminal depth: 8 mm.. Recommended stripping length: 8 mm Screw head :. Slotted head and Philips. Recommended tightening torque:. 0.8 Nm. Maximum tightening torque:. 1.2 Nm. Electrical connection diagram:. Cat. No. 046 72 : Tools required:. For the terminals: Philips no. 2 screwdriver or 4 mm flat screwdriver.. For attachment: 5.5 mm flat screwdriver (6 mm maximum). Terminal capacity: Copper cable Rigid cable 1 x 0.5 mm² to 16 mm² Flexible cable 1 x 0.5 mm² to 16 1 6 mm². Cat. No. 046 77: Pulse output or RS485 terminals:. Terminal depth: 8 mm.. Recommended stripping length: 8 mm Screw head :. Slotted head. Recommended tightening torque :. 0.4 Nm. Maximum tightening torque:. 0.8 Nm.. Cat. No. 046 81: Tools required:. For the terminals: 3 mm flat screwdriver.. For attachment: 5.5 mm flat screwdriver (6 mm maximum). Terminal capacity: Rigid cable Flexible cable Copper cable 1 x 0.5 mm² to 4 mm² 1 x 0.5 mm² to 4 mm² Technical data sheet: F01690FEN00 Updated on: - Created: 03/12/2012 2 / 5

ICS Marking on the device box:. By indelible pad printing:. 046 72 Front transparent marking:. By indelible pad printing:. Cat. No(s). 046 72 / 77 Cat. No. 046 81:. 046 77 Marking on the front panel:. By adhesive label:. Cat. No. 046 72:. 046 81. Cat. No. 046 77:. Cat. No. 046 81: 3 / 5

Display Type: 6-digit LCD Resolution: 0.1 kwh Maximum indication: 99999.9 kwh Value and programming indicator. By pressing the front button (see the instructions). Display:. Total active energy. Partial active energy (reset to zero possible). Current. Voltage. Active power. Operation time (reset to zero possible). Frequency (except for 04681). Power factor (except for 04681). Software version Metrological LED:. Pulse weight: 1 Wh/imp RS485 output characteristics (Cat. No. 046 77):. Address: from 1 to 247. Communication speed: 2.4-4.8 9.6 19.2 Kbps. Parity bit: none, even, odd. Galvanically isolated output for the measurement inputs. RS 485 standard - 2 pairs of twisted wires. Modbus protocol. Query response time < 200 ms Pulse output characteristics (Cat. No(s). 046 72 / 81):. SO according to EN62053-31, class A. Uimp voltage: max 110 V a.c./d.c.. Iimp current: max 50 ma. Pulse weight: Cat. No. 046 72: programmable; possible values: 1-10 - 100 Wh/imp - 1 kwh/imp Cat. No. 046 81: non-programmable; 10 Wh/imp.. Pulse duration: Cat. No. 046 72: programmable; possible values: 50-100 - 150-200 - 300-400 - 500 ms. Cat. No. 046 81 : non-programmable; 100 ms. Ambient operating temperature:. Min. = -25 C Max. = +55 C. Ambient storage temperature:. Min. = -40 C Max. = +70 C. Device protection:. By 40 A circuit breaker (Cat No. 046 81). By 63 A circuit breaker (Cat. No(s). 046 72 / 77) Protection rating:. Protection index for the terminals against solid objects and liquids: IP 20 (in accordance with standards IEC 529, EN 60529 and NF C 20-010).. Protection index for the enclosure against solid objects and liquids: IP 30 (in accordance with standards IEC 529, EN 60529 and NF C 20-010). Protection class:. II Degree of pollution:. 2 Overvoltage category:. III Precision. Active energy: class 1 in accordance with standard IEC 62053-21 Average weight per device:. 0.235 kg. Packaged volume:. 0.46 dm 3 Power consumption:. 4 VA. Heat dissipation:. 4 W. Glossary: CodE Password ModE A / ModE b Configuration Ct CT ratio Vt PT ratio time Integration time Addr Communication address baud Communication speed Par Parity bit none None EVEn Even odd Odd PLSt ACt Active energy pulse output PLSt rea Reactive energy pulse output PLSU Pulse weight PLSd Pulse duration PASS Password change 4 / 5

6. COMPLIANCE Compliance with standards:. Electromagnetic compatibility: IEC 62052-11. Measurement precision for the active energy: 1 (in accordance with IEC 62053-21). 7. COMMUNICATION Modbus connection system diagram:. The RT (120 Ω) termination resistors must be inserted on the first and last device connected to the RS485 bus in the same terminals (+,-) where the bus cable is connected. (1) RS485: Belden 9842 Cable (or equivalent) used for a maximum bus length of 1000 m or Category 6 Cable (FTP or UTP) for a maximum length of 50 m; (2) Integrated RT termination resistor; (3) Ethernet: Category 6 Cable (FTP or UTP); The pulse meters must be connected to the pulse concentrator (Cat. No. 0 046 87) for integration in a monitoring / energy metering system 5 / 5