netzerotools.com 374/375/376 Users Manual Clamp Meter

Similar documents
374/375/376 Clamp Meter

374/375/376 Clamp Meter. Users Manual

374/375/376 Clamp Meter

374/375/376 Clamp Meter

374 FC/375 FC/376 FC Clamp Meter

374/375/376. Calibration Manual. Clamp Meter

323/324/325 Clamp Meter

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

902 FC. HVAC True-rms Clamp Meter

312, 316, 318. Clamp Meter. Users Manual

Electrical Multimeter

T+ and T+ PRO Electrical Tester

NOTE: Fully read and understand this manual before using this Digital Multimeter.

15B & 17B. Multimeters. Users Manual

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

15B & 17B. Users Manual. Multimeters

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AMP-25 AMP-25-EUR. Mini-Clamp TRMS AC / AMP-25. ZERO 2 Sec

Electrical Multimeter

80i-110s. AC/DC Current Probe Instructions. Introduction

51-54 Series II. Thermometer

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

712C. Users Manual. RTD Calibrator

12B/18 MultiMeter Instruction Sheet

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Digital Clamp Meter Model: &

Models 110, 111 & 112

INSTRUCTION MANUAL UTL260

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

True-rms Multimeter. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

For detailed specifications and ordering info go to

True-rms Multimeter. Users Manual

User Manual Digital Multimeter. model no.: MSR-U1000

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

1507/1503. Insulation Testers. Users Manual

DMM8900 SERIES USERS MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

User Manual. All rights reserved. Specifications are subject to change without notice.

ICM 136R Operating Instruction Electrical Clamp-Multimeter

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Analog Technologies. Multimeter 15B and17b

CONTENTS MS2033A. 1.Introduction Safety Information...01

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

User Manual. All rights reserved. Specifications are subject to change without notice.

Circuit Breaker Finder

114, 115, and 117. True-rms Multimeters. Users Manual

USER'S MANUAL DMR-6700

600A Clamp Meters w/tightsight Display

DCM730. Digital Clamp Meter User s Manual

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

Model : OPERATING MANUAL Table of Contents (1)

114, 115, and 117. True-rms Multimeters

AM-540 AM-550. AM-540-EUR AM-550-EUR Digital Multimeter. Users Manual. Advanced HVAC Multimeter. Industrial Multimeter

1507/1503. Insulation Testers. Users Manual

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

Insulation Tester. Users Manual

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

User Guide. Digital AC/DC Clamp Meter Model 38394

200Amp AC Clamp Meter + NCV Model MA250

User s Guide. Digital AC/DC Clamp Meter Model 38394

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

KMD-S04 Multímetro de bolsillo

79/26 Series III Multimeter

Analog Technologies. Multimeter 115C and 117C

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Model UT233 OPERATING MANUAL

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Model 77 Series IV. Digital Multimeter. Users Manual

Table of Contents Title Page

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MS2030 CAT III 600 V A V AUTO RS232

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

UT232. Operating Manual. Digital Power Clamp Meter

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

AC/DC CLAMP METER USER S MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

ProfiScale MULTI Multimeter

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Instruction Manual IDM 66RT Digital Multimeter

1535/1537. Calibration Manual. Insulation Tester

175, 177, 179. True-rms Multimeters. Users Manual

DDM350 Pen-Type Digital Multimeter User s Manual

Operating Instructions 22070T True RMS AC/DC CLAMP METER Instrucciones de uso. Pinza amperimétrica de CA/CC de RMS verdadera

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

AC FLEXIBLE CURRENT PROBE CA 3000

Transcription:

374/375/376 Clamp Meter Users Manual Fluke 376 True RMS AC DC Clamp Meter Fluke 374 True RMS AC / DC Clamp Meter Fluke 373 True RMS AC Clamp Meter Fluke 375 True RMS AC / DC Clamp Meter

LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. 11/99

Table of Contents Title Page Introduction... 1 How to Contact Fluke... 2 Safety Information... 3 The Meter... 9 Specifications... 19 Electrical Specifications... 19 Mechanical Specifications... 26 Environmental Specifications... 27 i

374, 375, 376 Users Manual ii

Introduction XWWarning Read "Safety Information" before you use the Meter. The Fluke 374, 375, and 376 (the Meter) measure true-rms ac current and voltage, dc current and voltage, inrush current, resistance, and capacitance. The 375 and 376 also measure frequency and dc millivolts. The detachable iflex (Flexible Current Probe) that is included with the 376 (optional with the 374 and 375) expands the measurement range to 2500 A ac. The Flexible Current Probe provides increased display flexibility and allows measurements of awkward sized conductors and improved wire access. The illustrations in this manual show the 376. 1

374, 375, 376 Users Manual 2

Clamp Meters Safety Information Safety Information A Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and procedures that could cause Meter damage, equipment under test damage, or permanent loss of data. Symbols used on the Meter and in this manual are explained in Table 1. XWWarning To prevent possible electrical shock or personal injury, follow these guidelines: Use the Meter only as specified in this manual or the protection provided by the Meter can be compromised. Examine the case before you use the Meter. Look for cracks or missing plastic. Carefully look at the insulation around the connectors. Never measure current while the test leads are inserted into the input jacks. Make sure the battery door is closed and latched before operating the Meter. Remove the test leads from the Meter before the battery door is opened. Examine the test leads for damaged insulation or exposed metal. Check test lead continuity. Replace damaged test leads before using the Meter. Do not use the Meter if it operates incorrectly. Protection can be compromised. When in doubt, have the Meter serviced. 3

374, 375, 376 Users Manual Do not use the Meter around explosive gas, vapor or in damp or wet environments. Use only type AA batteries, properly installed in the Meter case, to power the Meter. When measuring current with the Jaw, keep fingers behind the Tactile Barrier. See "The Meter". To avoid false readings that can lead to electrical shock and injury, replace the batteries as soon as the low battery indicator ( ) appears. When servicing the Meter, use only specified replacement parts. Have the Meter serviced only by qualified service personnel. Be careful around voltages > 30 V ac rms, 42 V ac peak, or 60 V dc. Such voltages pose a shock hazard. Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and earth ground. When using the probes, keep fingers behind the finger guards on the probes. Connect the common test lead before connecting the live test lead. When disconnecting test leads, disconnect the live test lead first. Do not work alone so assistance can be rendered in an emergency. Use extreme caution when working around bare conductors or bus bars. Contact with the conductor could result in electric shock. 4

Clamp Meters Safety Information Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock and arc blast injury where hazardous live conductors are exposed. Disconnect circuit power and discharge all high-voltage capacitors before you measure resistance, continuity, or capacitance. For the 374 and 375, do not measure ac/dc current in circuits carrying more than 1000 V or 600 A with the Meter Jaw. For the 376, do not measure ac/dc current in circuits carrying more than 1000 V or 1000 A with the Meter Jaw. Never operate the Meter with the back cover removed or the case open. Do not measure ac current in circuits carrying more than 1000 V or 2500 A with the Flexible Current Probe. Do not apply the Flexible Current Probe around or remove from HAZARDOUS LIVE conductors. Do not use the flexible current sensor if the inner contrasting insulation color is showing. Take special care during fitting and removal of the Flexible Current Probe. Deenergize the installation under test or wear suitable protective clothing. 5

374, 375, 376 Users Manual WCaution To avoid possible damage to the Meter or to equipment under test: Use the proper jacks, function, and range for the measurement application. Clean the case and accessories with a damp cloth and mild detergent only. Do not use abrasives or solvents. Table 1. Symbols Symbol Meaning Symbol Meaning B AC (Alternating Current) J Earth ground F DC (Direct Current) ~ X Hazardous voltage P Do not dispose of this product as unsorted municipal waste. Go to Fluke s website for recycling information. Conforms to European Union directives. 6

Clamp Meters Safety Information Symbol Meaning Symbol Meaning W - Risk of Danger. Important information. See Manual. ) Battery. Low battery when shown T Double insulated on display. Examined and licensed by TÜV Product Services. Do not apply to or remove from HAZARDOUS LIVE conductors. ;, Conforms to relevant North American Safety Standards. Conforms to relevant Australian standards. Application around and removal from HAZARDOUS LIVE conductors is permitted. 7

374, 375, 376 Users Manual Symbol Meaning Symbol Meaning CAT III IEC Measurement Category III CAT III equipment has protection against transients in equipment in fixed-equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. CAT IV IEC Measurement Category IV CAT IV equipment has protection against transients from the primary supply level, such as an electricity Meter or an overhead or underground utility service. Note The Measurement Category (CAT) and voltage rating of any combination of test probe, test probe accessory, current clamp accessory, and the Meter is the LOWEST rating of any individual component. 8

Clamp Meters The Meter The Meter Clamp Meter fig01.eps 9

374, 375, 376 Users Manual Auto Power Off Backlight 20 ON ON fig02_3.eps 10

Clamp Meters The Meter Display Hold MIN MAX AVG 1x 2x 3x = = = 2 sec = Exit fig04_5.eps 11

374, 375, 376 Users Manual Flexible Current Probe 1 2 3 <0.5 A >0.5 A fig06.eps 12

Jaw Hz (375 & 376) Clamp Meters The Meter > 5 A > 20 A 1 2 <0.5 A >0.5 A Fig07.eps 13

374, 375, 376 Users Manual 3 1 <0.5 A 2 Fig08.eps 14

Clamp Meters The Meter dc (375 & 376) fig09_10.eps 15

374, 375, 376 Users Manual e R ON e R <30 Fig15.eps 16

Clamp Meters The Meter Off 3 On 100 ms 1 2 4 INRUSH fig13_14.eps 17

374, 375, 376 Users Manual 3 1 2 fig11_12.eps 18

Clamp Meters Specifications Specifications Electrical Specifications AC Current via Jaw Range 374 and 375...600.0 A 376...999.9 A Resolution...0.1 A Accuracy...2 % ± 5 digits (10-100 Hz) 2.5 % ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz)...3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2 % for C.F. > 2 19

374, 375, 376 Users Manual AC Current via Flexible Current Probe Range...2500 A Resolution 374 and 375...0.1 A ( 600 A) 1 A ( 2500 A) 376...0.1 A ( 999.9 A) 1 A ( 2500 A) Accuracy...3 % ±5 digits (5 500 Hz) Crest Factor (50/60Hz)...3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. > 2 20

Clamp Meters Specifications Position Sensitivity A B C Figure 1. Position Sensitivity ghn12.eps 21

374, 375, 376 Users Manual Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 374 and 375...600.0 A 376...999.9 A Resolution...0.1 A Accuracy...2 % ± 5 digits AC Voltage Range 22

Clamp Meters Specifications 374 and 375...600.0 V 376...1000 V Resolution 374 and 375...0.1 V 376...0.1 V ( 600.0 V) 1 V ( 1000 V) Accuracy...1.5 % ± 5 digits (20 500 Hz) DC Voltage Range 374 and 375...600.0 V 376...1000 V 23

374, 375, 376 Users Manual Resolution 374 and 375...0.1 V 376...0.1 V ( 600.0 V) 1 V ( 1000 V) Accuracy...1 % ± 5 digits mv dc Range 375 and 376...500.0 mv Resolution...0.1 mv Accuracy...1 % ± 5 digits Frequency via Jaw Range 375 and 376...5.0-500.0 Hz Resolution...0.1 Hz Accuracy...0.5 % ± 5 digits 24

Clamp Meters Specifications Trigger Level...5 10 Hz, 10 A Frequency via Flexible Current Probe Range 10 100 Hz, 5 A 100 500 Hz, 10 A 375 and 376...5.0 500.0 Hz Resolution...0.1 Hz Accuracy...0.5 % ± 5 digits Trigger Level...5 20 Hz, 25 A 20 100 Hz, 20 A 100 500 Hz, 25 A Resistance Range 374...6000 Ω 375 and 376...60 kω 25

374, 375, 376 Users Manual Resolution 374...0.1 Ω ( 600 Ω) 1 Ω ( 6000 Ω) 375 and 376...0.1 Ω ( 600 Ω) 1 Ω ( 6000 Ω) 10 Ω ( 60 kω) Accuracy...1 % ± 5 digits Capacitance Range...1000 μf Resolution...0.1 μf ( 100 μf) 1 μ F ( 1000 μf) Accuracy...1 % ± 4 digits Mechanical Specifications Size (L x W x H)...246 mm x 83 m x 43 mm Weight...388 g Jaw Opening...34 mm 26

Clamp Meters Specifications Flexible Current Probe Diameter...7.5 mm Flexible Current Probe Cable Length (head to electronics connector)...1.8 m Environmental Specifications Operating Temperature...-10 C +50 C Storage Temp...-40 C +60 C Operating Humidity...Non condensing (< 10 C) 90 % RH (at 10 C 30 C) 75 % RH (at 30 C 40 C) 45 % RH (at 40 C 50 C) Operating Altitude...3000 meters Storage Altitude...12,000 meters EMC...EN 61326-1:2006 Temperature Coefficients...Add 0.1 x specified accuracy for each degree C above 28 C or below 18 C 27

374, 375, 376 Users Manual Safety Specifications Safety Compliance...CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 P Agency Approvals...), ;, Batteries...2 AA, NEDA 15A, IEC LR6 28