POWER QUALITY PRODUCTS FOR NON-LINEAR LOADS

Similar documents
Power-Sure 700. Technical Data TD158001EN. Contents

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Power Conditioners product guide

PRODUCT FEATURES TYPICAL APPLICATIONS

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

Understanding Harmonics

HPS Universal BUCK-BOOST TRANSFORMERS

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Thyristorised Automatic Power Factor

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

ULTRA-K Series 600K - he

Power Quality Monitoring and Power Metering Tutorial

Power Quality Solutions

Drives 101 Lesson 5. Power Input Terminology for a VFD

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Power Protection and Conditioning

Harmonic Distortion Evaluations

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

1. Introduction to Power Quality

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

Harmonic Mitigating Transformer - Technical Guide

General Description & Features Selection Charts Definition of Terms... 42

POWER QUALITY A N D Y O U R B U S I N E S S THE CENTRE FOR ENERGY ADVANCEMENT THROUGH TECHNOLOGICAL I NNOVATION

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Glossary 78 LIFETIME LIMITED WARRANTY. GREENLEE Phone: (International)

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

BUCK-BOOST TRANSFORMERS

60K(i) - 260K(i) THREE PHASE. SureImage IMAGING & TREATMENT SERIES

2 Grounding of power supply system neutral

Power Processor - Series 700F 10KVA to 150KVA

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

Grounding for Power Quality

Straight Isolation - Plug In (171 Series)

Active Harmonic Filter (AF3)

Harmonic mitigating transformers. Energy savings through harmonic mitigation

Power Quality and Circuit Imbalances Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron

22.0 Harmonics in Industrial Power Systems

Harmonic mitigating transformers. Energy savings through harmonic mitigation

ENERGY SAVING WITH OPTIMIZATION OF VOLTAGE AND CURRENT QUALITY

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Harmonic Filters and Reactors

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

Literature Review for Shunt Active Power Filters

results at the output, disrupting safe, precise measurements.

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Non-Linear Load Transformers

Power Quality Analysers

Power Commander. Power Commander Plus. Electronic Line Voltage Regulators. 15 kva 150 kva SINGLE PHASE 15 kva 450 kva THREE PHASE SERIES 900

Emicon Engineering Consultants L.L.C.

How adjustable speed drives affect power distribution

Fundamentals of Power Quality

There s Gold in Those Waveforms Richard P. Bingham, Dranetz-BMI

TECHNICAL BULLETIN 004a Ferroresonance

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Scale Manufacturers Association (SMA) Recommendation on. Electrical Disturbance

Power Quality, Earthing And Bonding Oct $4,250 Dubai, UAE. In any of the 5 star hotels. The exact venue will be informed once finalized.

A statistical survey of common-mode noise

POWER QUALITY AND SAFETY

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

ECET Modern Power

The Effect of Various Types of DG Interconnection Transformer on Ferroresonance

CHAPTER 4 HARMONICS AND POWER FACTOR

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Phoenix DX Clean Power (18 Pulse) AC Drive

BIODEX MULTI- JOINT SYSTEM

~=E.i!=h. Pre-certification Transformers

Device Interconnection

Harmonic Filters for Single Phase Equipment

Industrial Electrician Level 3

Contents. Core information about Unit

FERRORESONANCE SIMULATION STUDIES USING EMTP

AC Motor Drives EMC Standard Installation Guide EMC Compliance Practice

p. 1 p. 6 p. 22 p. 46 p. 58

An Introduction to Power Quality

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

Tuningintobetter power quality

Please use the Q & A utility to ask us any questions concerning the material being presented.

IDEAL Test and Measurement THE BASICS OF POWER QUALITY

Load Isolation Transformers

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

MODEL 421 Over/Under Motor Load Monitor

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Any wave shape can be reproduced by the sum of sine waves of the appropriate magnitude and frequency.

Cetronic Power Products Ltd. REGUVOLT CONSTANT VOLTAGE TRANSFORMERS. Technical Information

6L]LQJ$8366\VWHP )RU1RQ/LQHDU/RDGV

TOSHIBA International Corp

Alternative Designs to Support Electronic Loads in Extensive UPS Distribution Systems

Active Harmonic Filter

Immunity Testing for the CE Mark

NJWA - Harmonics and Drives Proper System Design

The seven types of power problems

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

Transcription:

Voltage Regulators, Line Voltage Conditioners and Super Isolation Transformers Electrical Problems Related to Power Quality... 138 Electrical Problems on Non-Linear Systems... 139 Protection of Electrical Distribution Systems... 140 Power Factor... 141 Power Quality Solutions... 142 Voltage Regulators... 143 Line Voltage Conditioners... 144 Super Isolation Transformer Features... 145 Super Isolation, Selection Tables... 146

Electrical Problems Related to Power Quality Power Quality More and more, electricity is being considered as a product. Ideally, the AC voltage wave is a sine wave alternating from a positive peak to a negative peak 60 times per second (60 Hz) without any deformations, spikes or surges. In reality, different factors influence the quality of the wave. Certain disturbances come directly from the power source, such as lighting. Other disturbances come from loads; in particular, from electronic equipment which are non-linear loads that produce harmonics, due to their switching power supplies. As a result of voltage fluctuations as well as economic considerations, the non-linear power supply known as the switching power supply, was developed by computer manufacturers. Power conversion is no longer accomplished at 60 Hz AC-DC conversion is accomplished by a converter, which operates in the 20-100 khz range. Personal computers, workstations, local networks and other accessories that use these power supplies or this technology are very sensitive to problems caused by electric energy. Electrical issues can cause many problems on linear loads and other devices such as transformers, motors, circuit breakers, fuses, etc. Meanwhile, other hidden electric problems are caused by voltage spikes, voltage surges, brownouts, as well as by electric noise on the lines and can bring about different consequences. Voltage Spikes arise when equipment, which operates on high current is turned off, such as air conditioners, photocopiers, coffee makers, electric tools etc. These spikes, while brief, can destroy data stored on disk or on magnetic tape, modify memory and even cause serious damage to equipment (example: the breaking of a disk drive s reading head). Electric Noise is usually the worst of these problems because we cannot detect it without specialized instruments (e.g. recording device, oscilloscope, etc.). Noise can interfere with data signals by causing data transmission errors between the many components of a system. Certain noise in the high frequencies can even travel through circuit paths and destroy integrated circuits. Electric noise can be generated from any temporary high frequency (harmonic from 50 khz to 100 MHz), from a radio frequency (RFI) or from the production of electromagnetic interference (EMI) emitted from transformers or motors (often an elevator motor or a motor from a photocopier). As well, magnetic fields, induced by a mono-phased cable or by an unbalanced three-phased system, can deform images on a cathodic screen (computer monitor) or destroy data on a hard disk. There are two types of transient noise. The normal mode or transverse is due to an induced voltage between any two phase conductors (line-line). This voltage is normally in the low frequency range and causes damage to personal computers, local networks, and workstations. The common mode is due to an induced voltage between any phase conductor, including the neutral and the ground. This voltage can cause more damage than normal mode noise, not necessarily by its presence (2-3 V) but by the induce fluctuation that it produces. The common mode voltage is also produced by the presence of current on the neutral (E=IZ) and also because of the non-cancellation of the triplen on the phases that adds up on the neutral. Consequently, common mode voltage produces ground potential differences with other grounds. Non-linear loads (computers, variable speed drives, etc.) generate Harmonics. Harmonics produce an increase in the resistance of the conductor (skin effect) and, in turn, an abnormal common mode (neutral-ground) voltage difference. This will cause undesirable ground loops to occur. To save energy or to transform an alternating current into a direct current, their power source takes its current as portions of the 60 Hz sine wave. In doing so, the portions of the sine wave that the power supplies do and don t take causes the sine wave to become deformed and multiple frequencies of 60 Hz are formed. Often, single phase loads produce triplets (3 rd, 9 th, etc.), while three phase loads produce 5 th and 7 th harmonics. Therefore, electric equipment and installations which are designed to operate at 60 Hz, can become damaged or unbalanced due to these harmonic frequencies which are different than the 138

fundamental (60 Hz). The principal problem that arises is the overheating of equipment or conductors. The harmonic distortion rate (HDR) is the ratio between the harmonics and the fundamental load expressed as a percentage. Voltage surges can be compared to voltage spikes, except they last longer, from 15 microseconds to half a second or more. They are mainly caused by the shutdown of heavily loaded circuits or by the necessary commutation of a high-powered network (eg. Pf correction). Computers and other sensitive electronic equipment can seriously be damaged by such an over-voltage surge. Voltage surges which exceed normal voltages by 20%, affect numeric data, produce reading errors on verification systems and damage equipment. Temporal fluctuations produce parity errors and interrupts protection systems. Voltage sags are normally caused by the addition of heavy loads on an electric line such as the start-up of an elevator, photocopier or large motor. In this case, the current undergoes a loss of 20% or more for a period of 15 microseconds to half a second. Brownouts last longer than voltage sags. Brownouts are sometimes caused intentionally by the power company to avoid a total blackout when there is a great demand for electricity. They often lead to losses and even unresolved errors concerning central memory data or when data is being stored on disk or magnetic tape. In certain cases, if the brownout last long enough, it can cause an automatic shutdown of certain equipment. Flickering is a voltage variation with a lighting load that causes the light output to visibly flicker. This can be caused by the input in function of electro-domestic loads however, it is mostly due to industrial loads (eg. Motor start up or speed variation) Blackouts can last from a few microseconds to many hours or even days. These total losses of current normally occur due to damaged equipment or electric lines. Electrical Problems on Non-Linear Electrical Systems A switching power supply takes a portion of the maximum positive energy as well as the minimum negative energy on the sine wave. This deforms the sine wave, provoking a new wave. Fourier, the French mathematician, demonstrated that this new wave can be broken down as the sum of many waves (harmonics), for which the fundamental is at 60 Hz, and of all the present harmonics, the 2 nd at 120 Hz, the 3 rd at 180 Hz, etc. A spectral analysis gives us the amplitude of these waves and allows us to compare the relative importance of each of these. Electrical Distribution Systems Harmonics can cause fuses and circuit breakers to open a circuit for no apparent reason. An installation capable of supporting a certain amount of linear loads could no longer be able to support it after being replaced with nonlinear loads of the same power at 60 Hz. We should be seeing a rapid progression of this type of problem as new non-linear harmonic loads are added or replace traditional linear loads. With energy saving programs, utilities lead their customers to use switching power supply technology such as variable speed drives and electronic ballast. The laws of electricity have not changed but our knowledge of them becomes essential: The more the frequency increases, the more the metal becomes resistant (skin effect). Certain harmonics are at direct sequences (1, 4, 7, 10), others inverse (2, 5, 8, 11), and others without sequence are called triplets (3, 6, 9). Harmonics can damage transformers. Inverse harmonics have harmful effect on motors. Harmonics influence the power factor. 139

In a factory, if we find a certain amount of current harmonics, is there a problem? Ohm s law (V=IR) with a few exceptions, explains the consequences of these harmonics on inductive and resistive loads. Current distortions will create voltage distortions according to the line impedance. It is well known that for any non-linear load installation, it is very important that the impedance be as low as possible. One should always foresee the consequences of a current distortion on voltage or on the harmonic voltage distortion that it can bring about. Current harmonics are always present in non-linear loads and if they are properly dealt with, they will not always be problem sources. Protection of Electrical Distribution Systems Voltage Regulating Transformers (Computer Regulator) As well as insuring protection against spikes and surges, voltage regulators filter most of the electric noise which is often a hidden source of problems. Voltage regulators are more expensive than peak cut-off circuits (TVSS), but they protect much better since most are equipped with an isolation transformer. There are three types of voltage regulators on the market: the ferro-resonant transformers, tap switching transformers and the electronic voltage regulator. Single-phase Line Conditioning Transformers (Line Voltage Conditioner) Isolation transformers are sometimes equipped with peak cut-off circuits and filters and they can have a galvanic isolation. They therefore become great line conditioners, protecting against noise and spikes. Isolated Delta-Star Transformers (Super Isolation Transformer) This type of transformer is very popular. They cost less and can also isolate the application from the line. Peak cut-off circuits, filters and a double electrostatic shield can be added as options for protection against common mode noise and voltage spikes found on the line (for information on harmonics, see K-type, Delta-Wye for Non-linear Loads). Because of the galvanic isolation, there will be a link on the secondary between the neutral and the ground which eliminates the possible voltage between the neutral and the ground on the secondary of the transformer. To be more efficient, these transformers must, if possible, be installed close to the application. Since standard transformers were built to support linear loads, they may overheat and become damaged with non-linear loads. Harmonic Mitigating Transformer (0 or -30 primary-secondary Phase Shift) (refer to Section 8, page 199) Even if it is possible with a K-type transformer, depending on the quantity of Zero Sequence harmonics (triplets), to support non-linear loads, how can one know which loads will be applied in 6 months, 1 year, or more? Special interconnections secondary construction produces a cancellation of the 3 rd, 9 th, 15 th harmonics (triplets). So, if we build a transformer with a Delta primary and a double interconnected winding secondary to cancel triplen (zero sequence harmonics), we will have: An adaptable transformer for non-linear loads A low-impedance cancellation of the 3 rd, 9 th, 15 th harmonics A better equilibrium of phases and less harmonic voltage distortion (low-impedance Zero Sequence). An electrostatic screen and a peak cut-off filter could also be installed for additional protection against common mode noise. The installation of this kind of transformer is the same as for an ordinary transformer. Many existing applications use this type of construction. Because of its phase shifting of 0, it should be noted that by placing this type of transformer in a system composed of already existent Delta-Star transformers (-30º), a cancellation of the 5 th and 7 th harmonics will be 140

obtained. The 5 th and 7 th harmonics from the transformers will try to cancel the 5 th and 7 th harmonics coming from the already existent Delta-Star transformers (-30º). This will also improve the power factor. Harmonic Mitigation Transformer Dual Output (-15, -45º or 0º, -30 between the secondary double windings dual output) (refer to Section 8, page 199) This is a transformer with three phases on the primary and six on the secondary, so two sets of three phase outputs on the secondary. Because of the phase shifting between the two sets of three phase outputs: A cancellation of the 3 rd, 5 th, 7 th, 9 th, 15 th, 17 th and other harmonics like the 19 th on the secondary with a 0º and 30º angle difference and low impedance. An improvement in the equilibrium of the phases. A cancellation of triplets with only a difference of 0º and 60º. A cancellation of the 5 th, 7 th, 17th and 19 th harmonics with an angle difference of -15º and -45º and the triplets are trapped in the Delta winding. An important power factor improvement. Typical and General Construction for a Transformer in a Demanding Environment with Non-linear Loads Coil connections should be Delta on the primary and Star on the secondary. Even better, use double windings on the secondary which would diminish harmonic voltage distortions caused by current distortions (V=IR); this type of winding cancels triplets (3 rd, 9 th on the secondary) at very low impedance. The K-factor value should be well established with respect to the anticipated loads; for example, K13 can take up to 33% of the fundamental in the 3 rd harmonic, 20% in the 5 th, 14% in the 7 th, and 11% in the 9 th. A high performance grounded electrostatic shield may also need to be installed. As well, peak cut-off circuits and hybrid filters can be installed to make the transformer more efficient in protecting the loads in question. Uninterruptible Power Supplies These units isolate line to load at all times and are installed between the line and the load. They constantly provide power to keep equipment working (computers, servers, terminals, PLCs, etc.). In a blackout situation, they output a perfect sine wave without any transfer time or interruption. Power Factor Power Factor is the ratio between the apparent power (VA) and the real power (W). Energy suppliers deliver electricity with a sine voltage wave at 60 Hz. If the current and voltage waves are not aligned, the system s efficiency is diminished and the apparent power is greater than the real power. In an inductive system, the voltage wave is ahead of the current wave. In a capacitive system, it is the current sine wave that is ahead of the voltage sine wave. In order to compensate for the inductive effect of motors, correction is achieved using capacitors to align the two waveforms. There are now two causes that contribute to the deterioration of the power factor: inductive loads, which influence the displacement power factor, and non-linear loads when the current harmonics are not aligned with the voltage source. Total power factor which the utilities measure considers both of these causes. Knowing the cause for the deterioration of the power factor will help to choose the best way to correct it. In some cases, correcting harmonic problems can rectify the power factor. 141

Power Quality Solutions The solutions are as wide ranging as the problems. We have summarized some solutions in the table below. HPS SOLUTIONS POWER QUALITY PROBLEM GENERAL USAGE Voltage Regulators Industrial control malfunctions, Industrial Automation Control, Small Computer frequent voltage swings, up to 2 kva. Application. Single Phase Applications. Line Voltage Conditioners Computers, controls freezing or power Industrial PLC Application, Basic Computer supply frequent failure, common mode Protection. Single Phase Applications. voltages, up to 5kVA. Super Isolation Transformers Control room failure, freezing of Industrial Control Room, Hospital Equipment. Industrial control, common mode voltages, electrical noise. Harmonic Mitigating Transformer Voltage distortion, non-linear load current Standard Non-Linear Load Applications, Harmonic (refer to Section 8, page 199) distortions, short computer lives, poor total Cancellations, Building Design w/ Energy Saving, power factor. Total Power Factor Correction. Voltage Regulators protect equipment from both noise and voltage fluctuations. They are an inexpensive solution, available in both portable or hard-wired models. They provide ideal protection in high noise areas where voltage fluctuations exceed the regulating range of the computers power supply. Line Voltage Conditioners are isolation transformers equipped with peak cut-off circuits and filters and therefore become great line conditioners protecting equipment against noise and voltage spikes. Super Isolation Transformers provide inexpensive protection against frequency variation or noise related disturbances. This is adequate where voltage fluctuations are not a serious problem. Most high-end computers have built-in voltage regulation, but still require protection from line noise. Energy Efficient Harmonic Mitigating Transformers with zero sequence flux cancellation technology, provide total protection against all harmonics generated by computer equipment and other non-linear and power electronic loads (refer to Section 8, page 199). 142

FEATURES Portable Voltage Regulators are easily moved from place-to-place and attractively finished to adapt to any workplace. They provide ideal protection in high noise areas where voltage fluctuations exceed the regulating range of the equipment/system power supply. Epoxy potted windings are impervious to moisture from accidental spills. This makes them ideal for use between any wall outlet and your equipment. Protects equipment from both noise and voltage fluctuations Windings impervious to moisture Rejects Noise Controls voltage fluctuations UL and CSA Listed Attractively finished in brown and beige CONSTRUCTION FEATURES The voltage regulator is a ferroresonant transformer type regulator with a simple circuit configuration and has no moving components. This provides fast response, automatic output current limiting and high reliability. VOLTAGE REGULATORS APPLICATIONS Instrumentation Electronic cash registers Data terminals Communications equip. Micro processors Medical Diagnostics equip. Instrumentation Photographic equip. CAD/CAM systems Programmable controllers Security systems Scientific research equip. Test equipment Mini/micro computers Navigation equipment PERFORMANCE CHARACTERISTICS Input voltage range +/- 15% Output regulation/response time +/- 3%/1.5 cycles Frequency input range 59-61 Hz/49-51 Hz* Harmonic Distortion 3% Common mode rejection 120 db Normal mode rejection 60 db Audible noise 43 dba Efficiency 85% Holdup time 3 ms. * = 50 Hz Models A B 120V OUTPUT C 60 Hz Power Input Catalog Approx. Dimensions (inches) Approx. Rating Range Number Width Depth Height Weight VA VAC A B C (Lbs.) 70 95-130 CV70AFP 5.13 8.63 5.38 23.0 140 95-130 CV140AFP 5.13 8.63 5.38 23.0 250 95-130 CV250AFP 7.13 10.63 7.25 45.0 500 95-130 CV500AFP 7.13 10.63 7.25 55.0 750 95-130 CV750AFP 9.25 12.63 9.75 95.0 1000 95-130 CV1000AFP 9.25 12.63 9.75 100.0 1500 95-130 CV1500AFP 11.5 15.0 9.0 120.0 2000 95-130 CV2000AFP 11.5 17.0 10.25 140.0 Note: For 220V/50 Hz models, please contact our quotations department for specifications and delivery. 143

FEATURES Hard Wired Line Voltage Conditioners are designed to be installed directly to the utility power source to provide dedicated clean power to one or more outlets (depending on the unit size), for a variety of equipment. They provide ideal protection in high noise areas where voltage fluctuations exceed the regulating range of the equipment/system power supply. Epoxy potted windings protect against moisture, dust and other airborne contaminants and are ideal for office or plant locations. CONSTRUCTION FEATURES The Line Voltage Conditioner is a ferroresonant transformer type regulator with a simple circuit configuration and without moving components. This provides fast, responsive voltage regulation. LINE VOLTAGE CONDITIONERS PERFORMANCE CHARACTERISTICS Input voltage range +/- 15% Output regulation/response time +/- 3%/1.5 cycles Frequency input range (60 Hz models) 59-61 Hz Harmonic Distortion 3% Common mode rejection 120 db Normal mode rejection 60 db Audible noise 55 dba Efficiency 85% Holdup time 3 ms. * Not intended for Highly Inductive Loads APPLICATIONS CAD/CAM systems, medical equipment, security systems, test equipment, navigation equipment, data terminals, scientific equipment, communications equipment. SELECTION TABLE 120/240V OUTPUT 60 Hz Power Input Catalog Case Approx. Dimensions Approx. Rating Range Number Style (Inches) Weight VA VAC (Page 246) Width Depth Height (Lbs.) 250 120/208/240 CVHW250C L6 6.75 4.75 14.30 32 250 240/480 CVHW250D L6 6.75 4.75 14.30 32 250 600 CVHW250E L6 6.75 4.75 14.30 32 500 120/208/240 CVHW500C L7 6.75 6.25 14.30 43 500 240/480 CVHW500D L7 6.75 6.25 14.30 43 500 600 CVHW500E L7 6.75 6.25 14.30 43 750 120/208/240 CVHW750C L8 9.00 7.25 17.25 80 750 240/480 CVHW750D L8 9.00 7.25 17.25 80 750 600 CVHW750E L8 9.00 7.25 17.25 80 1000 120/208/240 CVHW1000C L9 9.00 8.50 18.25 95 1000 240/480 CVHW1000D L9 9.00 8.50 18.25 95 1000 600 CVHW1000E L9 9.00 8.50 18.25 95 1500 120/208/240 CVHW1500C L10 11.50 7.50 20.75 130 1500 240/480 CVHW1500D L10 11.50 7.50 20.75 130 1500 600 CVHW1500E L10 11.50 7.50 20.75 130 2000 120/208/240 CVHW2000C L11 11.50 9.00 20.75 158 2000 240/480 CVHW2000D L11 11.50 9.00 20.75 158 2000 600 CVHW2000E L11 11.50 9.00 20.75 158 3000 120/208/240 CVHW3000C L12 13.00 12.00 20.50 225 3000 240/480 CVHW3000D L12 13.00 12.00 20.50 225 3000 600 CVHW3000E L12 13.00 12.00 20.50 225 5000 120/208/240 CVHW5000C L13 15.00 12.00 25.00 325 5000 240/480 CVHW5000D L13 15.00 12.00 25.00 325 5000 600 CVHW5000E L13 15.00 12.00 25.00 325 144

FEATURES Clean, noise-free power output Low coupling capacitance Attractively finished in brown and beige CSA Certified SUPER ISOLATION TRANSFORMERS APPLICATIONS In many applications, a super Isolation Transformer will provide all the protection you need. This applies in areas where noise is a problem, but voltage fluctuation is not. For example: shopping malls, high rise complexes, airports, densely populated residential areas, etc. Super Isolators are also ideal for noise suppression for equipment having its own internal voltage regulation provided by the use of a switching power supply. Examples are: computers, life support systems, security systems and navigation systems. CONSTRUCTION FEATURES Super Isolators are shielded transformers with a simple circuit configuration and no moving components. This provides fast response, automatic out-put current limiting and high reliability with complete isolation from the power line. All units are hard wired. PERFORMANCE CHARACTERISTICS Common mode rejection... 146 db Transverse mode rejection... Typically 60 db Operating voltages... up to 110% of nominal Dielectric strength... 2500 VAC minimum Frequency input range... 47-63Hz for 50/60Hz units... 57-63Hz for 60Hz units DC Isolation 1000 megohms input to output and circuit to ground. SINGLE PHASE, SUPER ISOLATION TRANSFORMER DIMENSIONS A B C THREE PHASE, SUPER ISOLATION TRANSFORMER DIMENSIONS D E A F B C D E 0.50 DIA. F 145

SINGLE PHASE SELECTION TABLE kva Catalog Frequency Input Output Overall Dimensions (inches) Weight Rating Number Hz VAC VAC A B C D E F Lbs. 0.12 US10121 50/60 120/240 120/240 5.13 7.63 6.13 3.66 4.66 5.13 12 0.12 UT10121 60 120/240 120/240 5.13 7.63 6.13 3.66 4.66 5.13 10 0.25 US10251 50/60 120/240 120/240 5.13 9.63 6.13 3.66 4.66 7.13 18 0.25 UT10251 60 120/240 120/240 5.13 9.63 6.13 3.66 4.66 7.13 16 0.5 US10501 50/60 120/240 120/240 6.63 8.13 7.13 5.11 6.11 5.63 27 0.5 UT10501 60 120/240 120/240 6.63 8.13 7.13 5.11 6.11 5.63 23 1 US11001 50/60 120/240 120/240 6.63 9.63 7.13 5.11 6.11 7.13 44 1 UT11001 60 120/240 120/240 6.63 9.63 7.13 5.11 6.11 7.13 38 2.5 US12501 50/60 120/240 120/240 6.63 13.63 7.13 5.11 6.11 11.13 86 2.5 UT12501 60 120/240 120/240 6.63 13.63 7.13 5.11 6.11 11.13 75 5 US15001 50/60 120/240 120/240 9.63 12.63 9.88 8.11 9.11 10.13 138 5 UT15001 60 120/240 120/240 9.63 12.63 9.88 8.11 9.11 10.13 120 5 US15004 50/60 240/480 120/240 9.63 12.63 9.88 8.11 9.11 10.13 138 5 UT15006 60 600 120/240 9.63 12.63 9.88 8.11 9.11 10.13 120 10 US110001 50/60 120/240 120/240 9.63 19.13 9.88 8.11 9.11 16.63 225 10 UT110001 60 120/240 120/240 9.63 19.13 9.88 8.11 9.11 16.63 225 10 US110004 50/60 240/480 120/240 9.63 19.13 9.88 8.11 9.11 16.63 225 10 UT110006 60 600 120/240 9.63 19.13 9.88 8.11 9.11 16.63 225 15 US115001 50/60 120/240 120/240 13.25 21.56 12.38 11.73 12.73 19.06 325 15 UT115001 60 120/240 120/240 13.25 21.56 12.38 11.73 12.73 19.06 280 15 US115004 50/60 240/480 120/240 13.25 21.56 12.38 11.73 12.73 19.06 325 15 UT115006 60 600 120/240 13.25 21.56 12.38 11.73 12.73 19.06 280 20 US120001 50/60 120/240 120/240 13.25 21.56 12.38 11.73 12.73 19.06 375 20 UT120001 60 120/240 120/240 13.25 21.56 12.38 11.73 12.73 19.06 325 20 US120004 50/60 240/480 120/240 13.25 21.56 12.38 11.73 12.73 19.06 375 20 UT120006 60 600 120/240 13.25 21.56 12.38 11.73 12.73 19.06 325 THREE PHASE SELECTION TABLE kva Catalog Frequency Input Output Overall Dimensions (inches) Weight Rating Number Hz VAC VAC A B C D E F Lbs. 3 US3031 50/60 208 208Y120 25 19 27 21.5 24 13.5 190 3 UT3031 60 208 208Y120 25 19 27 21.5 24 13.5 170 3 US3034 50/60 240/480 208Y120 25 19 27 21.5 24 13.5 190 3 UT3036 60 600 208Y120 25 19 27 21.5 24 13.5 170 7.5 US3071 50/60 208 208Y120 25 19 27 21.5 24 13.5 265 7.5 UT3071 60 208 208Y120 25 19 27 21.5 24 13.5 240 7.5 US3074 50/60 240/480 208Y120 25 19 27 21.5 24 13.5 265 7.5 UT3076 60 600 208Y120 25 19 27 21.5 24 13.5 240 15 US3151 50/60 208 208Y120 28 20 30 24.5 27 14.5 355 15 UT3151 60 208 208Y120 28 20 30 24.5 27 14.5 320 15 US3154 50/60 240/480 208Y120 28 20 30 24.5 27 14.5 355 15 UT3156 60 600 208Y120 28 20 30 24.5 27 14.5 320 22.5 UT3221 60 208 208Y120 28 20 30 24.5 27 14.5 470 22.5 UT3224 60 240/480 208Y120 28 20 30 24.5 27 14.5 470 22.5 UT3226 60 600 208Y120 28 20 30 24.5 27 14.5 470 30 UT3301 60 208 208Y120 28 20 30 24.5 27 14.5 530 30 UT3304 60 240/480 208Y120 28 20 30 24.5 27 14.5 530 30 UT3306 60 600 208Y120 28 20 30 24.5 27 14.5 530 45 UT3451 60 208 208Y120 37 28 38 33.5 36 22.5 800 45 UT3454 60 240/480 208Y120 37 28 38 33.5 36 22.5 800 45 UT3456 60 600 208Y120 37 28 38 33.5 36 22.5 800 75 UT3751 60 208 208Y120 37 28 38 33.5 36 22.5 1500 75 UT3754 60 240/480 208Y120 37 28 38 33.5 36 22.5 1500 75 UT3756 60 600 208Y120 37 28 38 33.5 36 22.5 1500 146