Adaptive optimisation of illumination beam profiles in fluorescence microscopy

Similar documents
Quantitative high dynamic range beam profiling for fluorescence microscopy

Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

More fancy SPIM, Even fancier SPIM

Shaping light in microscopy:

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

MOM#3: LIGHT SHEET MICROSCOPY (LSM) Stanley Cohen, MD

Reflecting optical system to increase signal intensity. in confocal microscopy

Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy

Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets

SUPPLEMENTARY INFORMATION

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Aberrations and adaptive optics for biomedical microscopes

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

3D light microscopy techniques

Adaptive optics two-photon fluorescence microscopy

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

High-resolution, low light-dose lightsheet microscope LATTICE LIGHTSHEET

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Opti 415/515. Introduction to Optical Systems. Copyright 2009, William P. Kuhn

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Properties of Structured Light

Dynamic closed-loop system for focus tracking using a spatial light modulator and a deformable membrane mirror

Flatness of Dichroic Beamsplitters Affects Focus and Image Quality

Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Dynamic Phase-Shifting Microscopy Tracks Living Cells

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Zero Focal Shift in High Numerical Aperture Focusing of a Gaussian Laser Beam through Multiple Dielectric Interfaces. Ali Mahmoudi

Optical sectioning using a digital Fresnel incoherent-holography-based confocal imaging system

Microscope anatomy, image formation and resolution

Study of self-interference incoherent digital holography for the application of retinal imaging

Practical Flatness Tech Note

Supplementary information, Figure S1A-S1H The thickness and the uniformity of the light sheet at different DOFs. By

:... resolution is about 1.4 μm, assumed an excitation wavelength of 633 nm and a numerical aperture of 0.65 at 633 nm.

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Scanned light sheet microscopy with confocal slit detection

ABSTRACT 1. INTRODUCTION

Compact OAM Microscope for Edge Enhancement of Biomedical and Object Samples

Nikon Instruments Europe

INTRODUCTION TO MICROSCOPY. Urs Ziegler THE PROBLEM

a) How big will that physical image of the cells be your camera sensor?

Be aware that there is no universal notation for the various quantities.

Transmission Electron Microscopy 9. The Instrument. Outline

Martin J. Booth, Delphine Débarre and Alexander Jesacher. Adaptive Optics for

Shreyash Tandon M.S. III Year

Very short introduction to light microscopy and digital imaging

Confocal Microscopy and Related Techniques

Pulse Shaping Application Note

Lecture 20: Optical Tools for MEMS Imaging

Assembly and Experimental Characterization of Fiber Collimators for Low Loss Coupling

Introduction to Light Microscopy. (Image: T. Wittman, Scripps)

microscopy A great online resource Molecular Expressions, a Microscope Primer Partha Roy

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

3D light microscopy techniques

Three-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Development of a High-speed Super-resolution Confocal Scanner

Bringing Answers to the Surface

Heisenberg) relation applied to space and transverse wavevector

GRINTECH GmbH. product information.

Supplementary Materials

Introduction to light microscopy

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

Multiphoton Microscopy

Deep and fast live imaging with two-photon scanned light-sheet microscopy

arxiv: v1 [physics.optics] 7 Sep 2007

Big League Cryogenics and Vacuum The LHC at CERN

Rapid Non linear Image Scanning Microscopy, Supplementary Notes

Design Description Document

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

RECENTLY, using near-field scanning optical

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph

Experimental demonstration of polarization-assisted transverse and axial optical superresolution

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

INTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Measurement of the Modulation Transfer Function (MTF) of a camera lens. Laboratoire d Enseignement Expérimental (LEnsE)

Sensor Fusion Enables Comprehensive Analysis of Laser Processing in Additive Manufacturing

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

1 Introduction. Research Article

Katarina Logg, Kristofer Bodvard, Mikael Käll. Dept. of Applied Physics. 12 September Optical Microscopy. Supervisor s signature:...

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

SUPPLEMENTARY INFORMATION

Spectral Imaging with the Opterra Multipoint Scanning Confocal

A Compact Perpendicular Microscopy and Imaging System for the Detection of Fluorescent Solution Flow

MRO Delay Line. Performance of Beam Compressor for Agilent Laser Head INT-406-VEN The Cambridge Delay Line Team. rev 0.

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

3.0 Alignment Equipment and Diagnostic Tools:

Technology Note ZEISS LSM 880 with Airyscan

Rapid Adaptive Optical Recovery of Optimal Resolution over Large Volumes

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

Nature Methods: doi: /nmeth Supplementary Figure 1

Nature Methods: doi: /nmeth Supplementary Figure 1. sospim principle and representation of the sospim beam-steering unit.

Durham Research Online

BEAM SHAPING OPTICS TO IMPROVE HOLOGRAPHIC AND INTERFEROMETRIC NANOMANUFACTURING TECHNIQUES Paper N405 ABSTRACT

Transcription:

Adaptive optimisation of illumination beam profiles in fluorescence microscopy T. J. Mitchell a, C. D. Saunter a, W. O Nions a, J. M. Girkin a, G. D. Love a a Centre for Advanced nstrumentation & Biophysical Sciences nstitute, Department of Physics, Durham University, Durham DH1 3LE, UK ABSTRACT Wide-field fluorescence microscope techniques such as single/selective plane illumination microscope (SPM) are typically configured to image large regions of a sample at once. Here the illumination beam provides uniform excitation of several biological features across the region, sliced to a thickness of between 5 10 microns. n this paper we propose a simple alteration to the optical configuration of a SPM by switching the light-sheetforming cylindrical lens with a spatial light modulator. This has the potential to adaptively reconfigure the light sheet geometry to improve the optical sectioning of specific biological features, rather than the thicker sectioning of several features at once across a larger observation field-of-view. We present a prototype version of such a system, referred to as an Adaptive-SPM (A-SPM) system. We then suggest that the direct recording of illumination beam shapes within the working microscope system can better facilitate the analysis and subsequent re-configuration of the illumination beam to a specific geometry, and summarise the design and operation of a device that we have developed specifically for this purpose. We finally present reconstructed quantitative three dimensional flux maps of illumination beams from three microscope configurations taken using this miniature high-dynamic range beam profiling device, comparing the beam geometry of a regular SPM system with our prototype A-SPM system, and suggesting future improvements. Keywords: Fluorescence Microscopy, SPM, Embryogenesis, Beam Shaping, Beam Diagnostics 1. NTRODUCTON & THEORY Optically-sectioning fluorescence microscopy (FM) techniques have given modern developmental biologists the ability to observe dynamic processes within living specimens at high spatial and temporal resolutions. 1, 2 Unprecedented lateral and axial spatial resolution are achieved with the cost of either a slow raster-scan based imaging procedure, as in the case of confocal or multi-photon point-scanning fluorescence microscopy, or an even slower computationally-intensive image reconstruction procedure, as in the case of super-resolution methods such as structured illumination microscopy. Conversely, in the study of time-sensitive phenomena such as the embryogenesis of model organisms, a high temporal resolution is preferred and the relatively modest lateral resolution is accepted as a reasonable expense for the improvement in imaging speed. One such technique that has become widely adopted due to its low phototoxicity and rapid imaging capability is single or selective plane illumination microscopy (SPM). 3 n SPM, fluorescent excitation is provided by an illumination beam which is orthogonal to the axis of detection, as shown in Figure 1. A cylindrical lens is used to focus a collimated illumination laser beam in one lateral dimension, producing a sheet of light at the beam focus that illuminates a thin plane within the sample. 4 Alignment of this excitation region within the focal depth of the orthogonal detection objective lens allows optical sections of the sample to be recorded; a three-dimensional (3D) image of the sample can be produced by scanning the sample through the beam. Although there have been a number of different incarnations of light sheet-based techniques, the most predominant advances concerning line-scanned illumination where the light sheet is built up across the detection field of view by scanning a circularly symmetric beam orthogonal to the propagation direction, SPM remains the most rapid and simplest to implement of these techniques. Further author information: (Send correspondence to T. J. Mitchell.) T. J. Mitchell.: E-mail: t.j.mitchell@durham.ac.uk, Telephone: +44 (0) 191 33 43517 G. D. Love.: E-mail: g.d.love@durham.ac.uk, Telephone: +44 (0) 191 33 43696 Adaptive Optics and Wavefront Control for Biological Systems, edited by Thomas G. Bifano, Joel Kubby, Sylvain Gigan, Proc. of SPE Vol. 9335, 93350B 2015 SPE CCC code: 1605-7422/15/$18 doi: 10.1117/12.2080310 Proc. of SPE Vol. 9335 93350B-1

Light sheet dimensions: Y Z maging objective llumination beam Tube lens llumination launch objectve Figure 1. llumination and detection geometry of a SPM. A collimated illumination beam is focused in one dimension and relayed via an objective lens to the focal field of an orthogonal imaging system. The illumination beam shape can be parameterised according to its dimensions within the focal volume of the illumination objective lens: The sheet height is measured along y, the axis mutually orthogonal to both illumination and observation objective lenses; The sheet thickness is measured along x; The sheet length is measured along z, the optical axis of the illumination beam. The latter two dimensions of the light sheet are set by the beam waist and Rayleigh length respectively, and as such are coupled parameters. Since Gaussian beam optics dictate that the Rayleigh range and waist of a focused Gaussian laser beam are inextricably linked, in a SPM system this results in the propagation length of the light sheet within the sample being proportional to the optical slice thickness. Thus, in terms of the detected image, reducing the light sheet extent from a wide region of the sample down to a single cellular feature, results in an improvement in the optical sectioning of that particular feature as the sheet thickness reduces, and the increased numerical aperture (NA) of the illumination also help reduce shadowing artifacts in a similar, yet subtly different, fashion to multi-directional SPM. 5 Additionally, as biological specimens typically consist of many cellular surfaces and regions that have a distinct curvature, alteration of the light sheet focal length to locally match the position and topology of these features would result in feature-specific, well-sectioned images. However, to assess the success of such beam modifications, we need to directly quantify the beam shape within the confines of the microscope. We have previously developed a purpose built miniature camera probe, capable of reproducing a high dynamic range of flux values within such constrained volumes, demonstrating the operation of the device within a SPM. 6 n this paper we suggest an alternative SPM setup where the light sheet illumination beam is formed by an adaptive optical element rather than a static cylindrical lens. The operation of our custom beam profiling device is summarised and we present additional results of using the probe to profile several microscope illumination configurations, using these results to discuss the preliminary configuration of our prototype Adaptive-SPM system. 2. PROPOSED ADAPTVE-SPM SYSTEM n order to produce an adaptively-shaped illumination light sheet, we constructed a prototype SPM system where the cylindrical lens has been replaced by a spatial light modulator (SLM). As the beam s line-focus is now produced by an adaptive optical element, the focal length can be altered across the height of the sheet. The macroscopic light sheet formed by the SLM (BNS, Colorado, USA) is then telescopically re-imaged by a 4-f relay to the scale appropriate for microscope sample illumination, as shown in Figure 2. The 4-f relay was comprised Proc. of SPE Vol. 9335 93350B-2

2nd focus Spatial light modulator Tube lens io Microscope objective z llumination launch beam x Figure 2. Schematic of the illumination beam optics in our prototype Adaptive-SPM system. n this system a line focus is produced by focusing a collimated laser beam along one dimension only via a SLM. This line focus is then re-imaged via 4-f relay to an appropriate microscopic scale. of an achromatic doublet tube lens (focal length 250 mm, Thorlabs, UK) and microscope objective lens (M:10x; NA:0.25; WD:10.5 mm; Nikon, Japan). Formation of the line focus directly from an adaptive element allows the focal length of the beam to be altered along the height of the light sheet. 3. BEAM PROFLNG DEVCE A detailed account of our beam profiling device and its operation is published elsewhere. 6 n summary, we re-purposed a disposable sensor designed for endoscopy as a waterproof microscope beam probe and devised a quantitative high dynamic range (HDR) imaging procedure, calibrating the response of the sensor to a range of incident fluxes to allow the reconstruction of quantitative HDR flux maps. n short, our HDR imaging procedure is comprised of three main steps: First, we model the signal response of all sensor pixels to several uniform incident fluxes over a range of exposures. Next, we take images of the scene with a range of several exposures. Finally, for each pixel on the sensor we select the longest unsaturated exposure and use the known exposure time and recorded signal to numerically determine the best estimate of the flux incident at that pixel, via our sensor response model. By mounting the probe on an automated translation stage face-on to the optical axis of a beam, taking several exposures at any number of positions throughout the focal volume of the beam, a 3D beam profile can be recorded. 4. PROFLNG RESULTS & DSCUSSON n this section the z-scans of different microscope beams are presented, rendered as 3D beam profiles with colourmaps corresponding to the reconstructed flux magnitude. All of these beam profiles were recorded using a range of 10 exposures at each of 60 z-positions within the profiling volume: 0.18, 0.27, 0.45, 0.73, 1.09, 1.82, 3.27, 6.18, 11.82, and 20.91 ms. The reconstructed flux magnitude is a measure of the incident flux at the sensor relative to the fluxes used in the device calibration. 6 n each figure the relative flux scale has been thresholded and scaled to make the viewing and comparison of the overall beam structures in each reconstruction easier: n Figs.3&4 the maximum reconstructed fluxes are higher than the maximum presented colourbar value; in Fig.5 the maximum reconstructed flux at the beam focus matches the maximum presented colourbar value. 4.1 System : SPM Fig.3 shows beam profiles taken within the water tank of a dual-wavelength SPM microscope. n this system two separate laser light sources were directed through the same illumination optics to provide illumination that could excite two types of fluorophore at once, or switch between the two. Thus, for the microscope performance to be matched at both wavelengths, the illumination beam profiles were required to possess the same dimensions. The illumination beam wavelength was 488 nm in the leftmost reconstruction and 532 nm in the rightmost reconstruction. Both beam profiles were taken over the same 1.0 mm axial range. Proc. of SPE Vol. 9335 93350B-3

Wavelength 488 nm Wavelength 532 nm x Relative flux level 12 11 16 18 Figure 3. Reconstructed beam profiles taken within a dual-wavelength SPM system. The colourbar represents the incident flux level, relative to the uniform fluxes used in the calibration of the sensor. The left profile was taken with the blue laser illumination (wavelength 488 nm) and the right profile was taken with the green laser illumination (wavelength 532 nm). The light sheets are well-aligned within the focal volume and have the same height, thickness, and length dimensions. The overall profiled volume has dimensions of (x y z) are 0.74 mm 0.74 mm 1.0 mm. Water Air (7) ti ti a) m C; L d H 4 5 fi J 8 9 Relative flux level Figure 4. Reconstructed beam profiles taken within a microscope with switchable illumination beam geometry. The Bessel beams (top) feature a greatly extended bright focal region compared to the top hat beams (bottom). The axial extent of these beam profiles is 4.0 mm. green (right, wavelength 532 nm) light sheets are well-aligned within the focal volume and have the same height, thickness, and length dimensions. The overall profiled volume has dimensions of (x y z) are 0.74 mm 0.74 mm 4.0 mm. The dual-wavelength illumination beams are clearly well-aligned within the system, producing a line focus at the same position within the focal volume that has the same sheet parameters: height, thickness, and length. 4.2 System : Bessel vs. top hat n Fig.4 the profiles of two illumination beam geometries are presented for comparison both with (leftmost profiles) and without (rightmost profiles) water immersion of the beam. n this microscope system a SLM was conjugated to the pupil of the illumination objective and switched between axicon and uniform phase patterns to alter the illumination between Bessel and top hat beams. A wavelength of 532 nm was used - the design wavelength of the chosen SLM. These beam profiles were taken over a 4.0 mm axial range. Proc. of SPE Vol. 9335 93350B-4

Wavelength 532 nm Y 0.55 _ Relative flux level 1 7 2.2 2.0 3.3 Figure 5. Reconstructed beam profile of the light sheet illumination formed using our prototype adaptive SPM system. The overall profiled volume has dimensions of (x y z) are 0.74 mm 0.74 mm 2.4 mm. The reconstructions clearly demonstrate the extended focal range of the Bessel beam illumination compared with that of the top hat illumination beam. Additionally, the profiles taken without water immersion demonstrate a distinct deviation of the beam direction and relative flux magnitude when compared with the water-immersed beam profiles. 4.3 System : Adaptive SPM Fig.5 shows a reconstructed beam profile obtained from a preliminary configuration of our A-SPM system set up to produce a simple line focus. This beam profile was taken over a 2.4 mm axial range. A comparison of the light sheet dimensions from our SPM and prototype A-SPM systems is given in Table 1. Though the current beam produced in our prototype A-SPM system does not match the dimensions of a regular SPM beam geometry our results demonstrate the successful replacement of the cylindrical lens typically used in SPM with an adaptive element. t is worth noting here that the 100 µm light sheet height is actually well-suited to particular features of the zebrafish (Danio rerio), especially the eye lens. As such the illumination dimensions that need to be altered in future A-SPM configurations for feature-specific optical sections are only the thickness and length of the light sheet. n the present configuration the rear aperture of the objective lens is under-filled, and thus the light sheet has a very low NA, resulting in a thick light sheet with a long length. Future configurations will reduce the thickness and length dimensions of the A-SPM light sheet down past that of our regular SPM beam by increasing the beam size across the rear aperture of the illumination objective, and using a higher NA objective lens if necessary, to improve the feature-specific optical-sectioning capabilities of the system. Following this we will implement adaptive alteration of the local focal position of the light sheet to match the curvature of specific features within biological specimens. 5. SUMMARY We have suggested that adaptively-shaped illumination beams in fluorescence microscopy will allow improved sectioning of specific biological features within model organisms. For such an approach to be successful it is Table 1. Comparison of illumination beam dimensions of light sheets formed in our SPM and prototype Adaptive-SPM system. System Sheet thickness (x)/ µm Sheet height (y)/ µm Sheet length (z)/ µm SPM 6 400 30 A-SPM 10 100 320 Proc. of SPE Vol. 9335 93350B-5

desirable to directly obtain quantitative measurements of the 3D beam shape within the working microscope. We have presented further results of using a purpose-built beam probe within a range of microscope configurations, including a prototype Adaptive-SPM system where the cylindrical lens of a SPM was replaced by a SLM. Our Adaptive-SPM system demonstrates the successful formation of a light sheet by an adaptive optical element; future configurations of the device will demonstrate specific alteration of the light sheet shape to match the curvature of individual cellular features within model organisms such as the zebrafish. ACKNOWLEDGMENTS This work was funded by the EPSRC, the British Heart Foundation Research Excellence Award (Edinburgh), and RCUK. REFERENCES [1] J. A. Conchello and J. W. Lichtman, Optical sectioning microscopy., Nat. Methods 2, pp. 920 931, 2005. [2] B. R. Masters, The Development of Fluorescence Microscopy, in els, pp. 1 9, J. Wiley & Sons, Ltd, 2010. [3] J. Huisken, J. Swoger, F. Del Bene, J. Wittbrodt, and E. H. K. Stelzer, Optical sectioning deep inside live embryos by selective plane illumination microscopy., Science 305(5686), pp. 1007 9, 2004. [4] K. Greger, J. Swoger, and E. H. K. Stelzer, Basic building units and properties of a fluorescence single plane illumination microscope, Rev. Sci. nstrum. 78(2), p. 023705, 2007. [5] J. Huisken and D. Y. R. Stainier, Even fluorescence excitation by multidirectional selective plane illumination microscopy (mspm), Opt. Lett. 32(17), pp. 2608 2610, 2007. [6] T. J. Mitchell, C. D. Saunter, W. O Nions, J. M. Girkin, and G. D. Love, Quantitative high dynamic range beam profiling for fluorescence microscopy., Rev. Sci. nstrum. 85(10), p. 103713, 2014. Proc. of SPE Vol. 9335 93350B-6