PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

Similar documents
DPS Applications. Features

NAT Applications. Features

NAT Applications. Features

NGR. Guided Wave Radar Level Transmitter

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Electromagnetic flowmeter in all metal design Model MIM

DUK. Compact Ultrasonic Flowmeter

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

Low Pressure NSL Applications. Features

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Industrial Pressure Transmitter

ECT Applications. Features

INDUSTRIAL PRESSURE TRANSMITTER

Temperature Transmitters

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

Full Metal Variable Area Flowmeter and Counter Model BGF

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

Through-beam ring sensors

Level Sensors Reed Contact Chain

Frame through-beam sensors

Electronic Temperature Transmitters

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany

Pressure Transmitter SIL

Operating instructions. Combined pressure sensor PN /00 11/03

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

Coriolis Mass Flow Meter Model TM

Magnetic Inductive Flowmeter

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Coriolis Massflowmeter

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

The compact test- disconnect terminal interface system for protection and secondary technology

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Liquid Level Switches

ED701 General Industry Pressure Transmitter

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

2-channel speed sensor GEL 247 Compact sensor for harsh applications

Electronic Pressure Switch Type MEP

Paddle wheel flow controller for On/Off control

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Operating instructions. Electronic pressure sensor PY2068 ENGLISH

Operating instructions Electronic level sensor LK / / 2008

DUK COMPACT ULTRASONIC FLOWMETER

Electronic temperature switch with display Model TSD-30

Online data sheet MAX48N-31V10K12500 MAX48 LINEAR ENCODERS

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Pressure transmitter For general industrial applications Model A-10

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet

Pressure transmitter for general industrial applications Model A-10

Electronic Flow Monitor

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

High-quality pressure transmitter For general industrial applications Model S-10

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Pressure transmitter For general industrial applications Model A-10

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

COMPACT-LINE. Transmitter for ph-value

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Insertion Flow sensor for continuous flow measurement

Temposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet

Online data sheet. PBSH-CB010ST1S0BMA0Z PBS Hygienic PRESSURE SENSORS

Pressure transmitter for general industrial applications Model A-10

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Ultrasonic Sensor (HART)

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

LENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output

Creating the world technology leader in surface solutions under one roof

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Mexico s Fastener Imports

M5800 Pressure Transducer with Rotatable Display

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Digital flow ELEMENT transmitter for continuous flow measurement

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Keysight Technologies E1834E/G/J/M/Z Mounted Beam Delivery Optics. Preliminary Data Sheet

Features. Picture. Specifications

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

1204 Reflected Wave Reduction Device

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Your Global Automation Partner. PT2000 Pressure Transmitter

Technical data. General specifications. Measurement range min max. 360

Magnetic absolute rotary encoder GEL 235 Singleturn, Multiturn up to 28 bits (SSI)

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

High Temperature Fluxgate Probes

Positioning drives DC motor, brushless Absolute multiturn position detection, Profibus-DP

OEM Relativ- und Absolut-Drucktransmitter OEM Relative and absolut pressure transmitter OEM Transmetteur de pression relative et absolue

Temperature sensor with integrated transmitter for maritime applications, MBT 5560

Transcription:

Digital ressure Sensor LED Display with Switch & Analog Outputs measuring monitoring analyzing SD Measuring Range: 0...30 to 0...7500 SI Temperature Range: -13...185 F Accuracy (at 77 F): ± 0.5 % FS Connection: 1/4" NT Analog Output: Switchable ma or V Switching Output: 2 N Transistors Adjustable ressure Range: 50 100% of the Nominal Range Display Housing and Electrical Connection are Independently Rotatable 335 / 343 3-Key rogramming OEM ricing Available 01/11-06- 2017 KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REUBLIC, EGYT, FRANCE, GERMANY, HUNGARY, INDIA, INDESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, ERU, OLAND, REUBLIC OF KOREA, ROMANIA, SINGAORE, SAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM KOBOLD Instruments, Inc. 1801 arkway View Drive ittsburgh, A 15205 Main Office: 1.800.998.1020 1.412.788.4890 info@koboldusa.com

Description The economical SD offers the ideal combination of two pressure switches and a scalable transmitter output with a 45 degree viewable, rotatable display. The parameters can be set directly on the device. Within the settings, there are a comprehensive set of options, making the SD suitable for a wide range of demanding applications. There is integral hysteresis, window, and delay functionality included. OEM quantity pricing available upon request. Applications Machine Tools Hydraulics rocess Technology Industrial Applications OEM Targeted roduct Technical Details Measuring rinciple: Measuring Range: Output Signal: Switching Output: Accuracy @ 77 F typ.: Thin Film 0...30 to 0... 7500 SI, Adjustable 50... 100 % FS 4... 20 ma 0...10 V DC, Switchable ma or V 2 N Transistors ± 0.5 % FS typ. Media Temperature: -13...185 F Ambient Temperature: -13...185 F Display Units: psi, bar, Ma, ka, m WC, mm WC Electrical Data Output/Supply Voltage: 4... 20 ma or 0-10 V DC / 24 (15... 30) V DC Switch-On Delay: typ. 200 ms Inverse-polarity rotection, Short-circuit Strength @ 77 F During 5 min.: Integrated Current Consumption: 30 ma Environmental Conditions Media Temperature: -13...185 F Ambient Temperature: -13...185 F rotection 1) : I65 Humidity: Max. 95 % Relative Vibration: 10 g (10... 2000 Hz) Shock: 50 g / 3 ms 1) See»Electrical Connection«Analog Output Output Signal: 4-20 ma or 0-10 V DC Accuracy: TEB 2) @ -13...185 F [% FS typ.] ± 1.75 Accuracy @ 77 F [% FS typ.] ± 0.5 NLH 2) @ 77 F (BSL 2) ) [% FS typ.] ± 0.2 TC 2) Zero oint and Span [% FS/K typ.] ± 0.03 Long Term Stability 1 Year [% FS typ.] ± 0.1 Current Limiting Output Signal: 4-20 ma: 25 ma (Overload) 0... 10 V DC : < 40 ma (Short-circuit) Damping (Rise Time): 0.01... 3.00 s / 10... 90 % Nominal ressure Switching Output Accuracy: Accuracy @ 77 F [% FS typ.] ± 0.5 TEB 2) @ -13...185 F [% FS typ.] ± 1.0 Long Term Stability 1 Year [% FS typ.] ± 0.3 Adjustment Range of Switchpoints: 0 100 % FS Switching Hysteresis: 1 % FS Switchpoint > Reset oint Switching Resistance: 3 Ω Output Function: Hysteresis, Window; Normally Closed (NC), Normally Open (NO) Switching Current: 0.5 A Each Switching Output Current Limiting: 2 A Each Switching Output Switching Frequency: Max. 200 Hz Delay Time: 0... 99.99 s Display Display: 4-Digit, 7-Segment Display, 180 Flippable with Disable Function Standard Decimal laces: 9: 3 Decimal laces 10... 99: 2 Decimal laces 100... 999: 1 Decimal lace Switching Status Indication: 2 LED, Red Operation: with 3 Buttons and Menu Navigation According to VDMA 24574-1 Display Resolution: 0.1 % FS Display Range: -3... 103 % FS Setting arameters: See arameter Table, pg 4 2) See Terminology Section on page 6 2

Mechanical Data Sensor (Wetted arts): 1.4542 (AISI630) ressure Connection (Wetted arts): 1.4542 (AISI630) Housing: Steel, Die Cast Metal Galvanized Display Housing lastic Connection: 1/4" NT Male Electrical lug: A-plug M12x1.5-pin Mounting Torque: 15... 20 Nm Housing Alignment: Display 335 Rotatable, Max. 2.5 Nm Electrical Connection 343 Rotatable, Max. 5 Nm Surge Damping Orifice: Ø 0.4 mm Weight: ~189 g Overpressure and Burst ressure Range (SI) Overpressure (SI) Burst ressure (SI) 0..30 90 700 0...50 150 850 0...100 300 1450 0...150 450 2500 0...200 600 2500 0...300 900 4000 0...500 1500 4000 0...1000 3000 5000 0...1500 4500 7000 0...2000 6000 10000 0...3000 9000 14500 0...5000 12500 21750 0...7500 18750 29000 Measuring Accuracy 0.5 % Accuracy (%) 5 4 3 2 1 0-1 -2-3 -4-5 -30-20 -10 0 10 20 30 40 50 60 70 80 90 Temperature ( C) max. typ. TEB Total (-25 Error... Band +85 C) (TEB) (-25... +85 C) Order Details (Example: SD-4 3 3 N2 045) Model Version Electrical Connection Material Connection Measuring Range Option..045 = 0...30 psi..055 = 0...50 psi..065 = 0...100 psi..075 = 0...150 psi..085 = 0...200 psi SD-....4.. = 2 x N Switching Output, Analog Output 4-20 ma..3.. = M12 lug, 24 (15-30) V DC..3.. = Stainless Steel Connection..N2.. = 1/4" NT Male..090 = 0...300 psi..100 = 0...500 psi..115 = 0...1000 psi..40 = Surge Damping Orifice D = 0.4 mm..126 = 0...1500 psi..130 = 0...2000 psi..140 = 0...3000 psi..150 = 0...5000 psi..170 = 0...7500 psi 3

Accessories Model Number Cable Length Description Number of Contacts 807.007 2 meters (6 feet) M12 Accessory Cable 5 807.007/5M 5 meters (16 feet) M12 Accessory Cable 5 807.007/10M 10 meters (32 feet) M12 Accessory Cable 5 ZUB-KAB-12D500 NA M12 box, screw connection 5 arameter Switch oint S1 (Hysteresis Mode) Upper Switch oint FH1 (Window Mode) Reset oint R1 (Hysteresis Mode) Lower Switch oint FL1 (Window Mode) Switch oint S2 (Hysteresis Mode) Upper Switch oint FH2 (Window Mode) Reset oint R2 (Hysteresis Mode) Lower Switch oint FL2 (Window Mode) Name Standard Setting Value Range Switch oint Delay Time S1 (Hysteresis Mode) Switch oint Delay Time FH1 (Window Mode) Switch oint Delay Time R1 (Hysteresis Mode) Switch oint Delay Time FL1 (Window Mode) Switch oint Delay Time S2 (Hysteresis Mode) Switch oint Delay Time FH2 (Window Mode) Switch oint Delay Time R2 (Hysteresis Mode) Switch oint Delay Time FL2 (Window Mode) Functions Switching Output 1 Functions Switching Output 2 75 % Measuring Range 25 % Measuring Range 75 % Measuring Range 25 % Measuring Range S1 > R1 FH1 > FL1 R1 < S1 FL1 < FH1 S2 > R2 FH2 > FL2 R2 < S2 FL2 < FH2 Short Name S1 R1 S2 R2 0 0... 99.99 s ds1 0 0... 99.99 s dr1 0 0... 99.99 s ds2 0 0... 99.99 s dr2 Hysteresis, N/O (Hno) Hysteresis, N/O (Hno) Hysteresis NO (Hno), Hysteresis NC (Hnc), Window NO (Fno), Window NC (Fnc) Hysteresis NO (Hno), Hysteresis NC (Hnc) Window NO (Fno), Window NC (Fnc) ressure Units psi psi, bar, Ma, ka, m WC uni Measuring Range Adjustment 100 % Nominal ressure 50... 100 % Nominal -E Damping (Analog Output) 0.01 s 0.01... 3.00 s (Time Constant) daa Display Rotation No No, Yes (180 ) disr Display Mode Current ressure Value ressure Value: Current, Highest, Lowest, Display Off Current Value: Decimal laces Selectable (Max. 3) Display Update 2 1, 2, 5, 20 Hz dud ou1 ou2 dis 4

Dimensions (mm) SD Ø 37 SD-... N2... 93 335 max. 2.5 Nm M12x1 343 max. 5 Nm 1/4" NT 45.5 Ø 32 48 SW27 / Ø 29.5 Electrical Connection rotection / Electrical Connection I65 M12x1 5-pole 3 2 5 in Configuration U / I Out 4 1 in Assignment Us+ = 1 Us + Us Us- = 3 US+ US Out analogue Output = 2 S1 S1 = 4 I S2 S1, S2 S2 = 5 RL Shield Shield Earth US Connection of loads to switching output Functions Switching Output Hysteresis Window Delay S FH S r FL r t Hno Fno t t Hno Hnc Fnc Hnc ds dr 5

Terminology References BSL: Best Straight Line The reference line according to the BSL or the minimum value adjustment is placed in such a way that the maximum positive and negative deviations are as small as possible. Specifications: Accuracy NLH (BSL) Long-term Stability and Long-term Drift The change of accuracy due to aging under certain reference conditions during a period of time, typically one year. Non-linearity The largest deviation from the effective characteristic line of an ideal reference line. The reference line can be defined as a limit point adjustment, a BSL, or a BSL through 0. Specifications: Non-linearity, Hysteresis BSL/0: Best Straight Line through Zero As an additional requirement for the minimum value adjustment, the BSL through zero (also BSL/0) must go straight through zero or the origin. Specifications: Accuracy NLH (BSL through Zero) NLH: Non-linearity and Hysteresis Largest deviation from the ideal characteristic line (BSL, BSL/0 or limit point). In pressure measuring instruments, the non-linearity and pressure hysteresis are given together at a constant temperature. TEB: Total Error Band Total error (root from sum of the square of the deviations) due to measurement deviations (accuracy) and temperature influence (temperature coefficient TC). The temperature influence is usually given in the information across a range larger than that given in the standard (-10...60 C). TC: Temperature Coefficient Change of measured value for zero point and span as a result of changes in temperature. 6