INSTALLATION INSTRUCTION Indirect Recessed Channel

Similar documents
INSTALLATION INSTRUCTIONS Oculux 3.5 Architectural Remodel

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

SUPERPLANE TM 4 RECESSED SP4R

INSTALLATION INSTRUCTION OCULUX 3 LED - New Construction

INSTALLATION INSTRUCTIONS SUPERPLANE 4 WALL MOUNT. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Installation Instructions For TruLine 1.6A 24VDC

SUPERPLANE 2.5 INSTALLATION INSTRUCTIONS WALL/SURFACE BACK MOUNT. A nd Avenue, Unit 1 Oakland,

SLOT INSTALLATION GUIDE Indoor IP20

Installation Instructions For Reveal

ROUND LIGHTPLANE 1 3D FLUSH

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

Obtained from Omarshauntedtrail.com

Installation Instructions For Reveal Light Channel

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Pow-R-Feed Systems Service Manual

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Lightplane 3.5 Recessed

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

Straight Stringer Installation Instructions

Installation Instructions for TruLine 1A Center Feed Power Channel Connector

Frameless Inline Door With Return QCI5263

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Installation Instructions

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

Frameless Inline Door QCI5248

Quantum 2 SQUARE 0808K

Installation Instruction

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

DISCONNECT POWER PRIOR TO ANY INSTALLATION.

BEFORE YOU BEGIN Read these instructions completely and carefully.

Installation Instructions and Details

Installation Instructions

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

1. TOOLS + MATERIALS REQUIRED

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

QUANTUM 2 CIRCLE 24 Installation Instructions

BEFORE YOU BEGIN Read these instructions completely and carefully.

Frameless Inline Door QCI5254

Installation Instructions

BEFORE YOU BEGIN Read these instructions completely and carefully.

Installation Instructions For Heavy Duty (FAS Models) and Median (FAM Models) Air Conditioners

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

BEFORE YOU BEGIN Read these instructions completely and carefully.

TIP FOR GETTING STARTED

Over the Range Microwave Oven

BEFORE YOU BEGIN Read these instructions completely and carefully.

QUANTUM 2 TRAPEZOID 2509 Installation Instructions

BEFORE YOU BEGIN Read these instructions completely and carefully.

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Deauville Installation Guide

INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Installation Instructions

Installation Instructions

Cellular SlumberShade

INSTALLATION AND CARE INSTRUCTIONS

Tools Required. Bench Hardware. Bench Parts. Planter Hardware. Planter Parts. BENCH/PLANTER INSTALLATION GUIDELINES for

BEFORE YOU BEGIN Read these instructions completely and carefully.

Assembly Instructions

WG-4 Wall Guard Installation Instructions

FIXED PANEL SLIDER QCI5241

Series----SP3600A SHOWER DOOR

Installation Instructions

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

Installation Instructions For Slider Casement Air Conditioners

Installation, Operation and Care Instructions. Retractable Cord Operating System

Frameless Inline Door QCI5250

Wall Panel Installation Instructions

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

3/16 OR 1/4 FRAMELESS SWING DOOR WITH SINGLE INLINE PANEL OR TWO INLINE PANELS

Curium 19.4H Installation Instructions & Parts List

FACTORY STRETCH INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need

10x10 Trellis Pergola

Two Panel Frameless Bypass Door

Installation Manual Flat Track Series

Cabinetry Installation

Installation Instructions

INSTALLATION AND CARE INSTRUCTIONS

Lightline Movable Wall Installation Manual. Preliminary Draft #

Deauville Installation Guide

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

Installation Instructions

Installation And Care Instructions. Vertical Honeycomb Shades

MAGNUM BOARD INTERIOR INSTALLATION GUIDELINES

Installation Instructions

Dura-Lock Roof System

INSTALLATION INSTRUCTIONS 960 RODA GLASS TO GLASS HINGES ANGLED FRAMELESS PANEL / DOOR / PANEL CELESTA DRESDEN TRESOR

PARTS INCLUDED IN FIXED STAIR CABLE RAIL KIT:

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

installation instructions

Xenon 05 Installation Instructions & Parts List

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

Installation Instructions

Transcription:

SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. Always turn off power at fuse box prior to installation to prevent electrical shock. Intended for indoor use. Dry and damp locations. For installation by a qualified electrician. System is intended for installation in accordance with National Electric Code, and local regulations. Consult with local inspector to assure compliance. Instruction de sécurité IMPORTANT: NE JAMAIS tenter tout travail sans couper l'électricité. Lisez toutes les instructions avant d'installer. Toujours couper l'alimentation électrique à la boîte à fusibles avant l'installation pour éviter les chocs électriques. Destiné à une utilisation en intérieur. endroits secs et humides. Pour l'installation par un électricien qualifié. Le système est destiné à être installé conformément au Code national de l'électricité, et les réglementations locales. Consultez l'inspecteur local pour assurer la conformité. COMPONENTS: LED-TC-B-2L LED-T-CH-PER LED-T-CH-INS LED-T-CH-JOIN LED-T-CH-BIT LED-T-CH-SINK LED-T-CH-END3-WT LED-T-RBOX3-WT (sold separately) a) LED-T-CH-END3-WT (1) INSTALLED b) LED-T-CH-JOIN (1) c) LED-T-CH-SINK (1) d) LED-TC-B-2L (4) e) LED-T-CH-BIT (1) f) LED-T-CH-INS (1) LED-T-RCH1-WT a) LED-T-CH-PER (10) b) LED-T-CH-JOIN (1) WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 1

INSTALLATION: 1. Disassemble the Junction Box & Hanger Bars from LED-T-RBOX3-WT (Keep all of the components and screws for later installation.) Junction Box Hanger Bars Spacer Spacer Screws Channel Section Screw Channel Inner Cover 2 Channel Section Channel Inner Cover Screws LED-T-CH-END3-WT End Cap Channel Inner Cover 1 Channel Outer Cover Screw Channel Outer Cover WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 2

2. Junction Box can be mounted horizontally or vertically by using the Mounting Brackets & Screws depending on the orientation of the channel. Junction Box can be slid along the Hanger Bars by loosening and fastening the Locking Screws on both top and bottom. Remove Knockouts on the Junction Box as necessary before mounting it. If channel is desired to be mounted horizontally: Hanger Bars Locking Screws Mounting Bracket Screws Hanger Bar Mounting Bracket Junction Box If channel is desired to be mounted vertically: Knockouts WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 3

Select the location between two Studs for the Junction Box to be mounted. Place the adjustable Hanger Bars between the Studs (14 1/2 to 24 1/2 ). Use supplied Screws to secure the Hanger Bars at desired position. Make sure that the Hanger Bars are mounted at 1 11/16 from the edge of the studs. Studs Min 14 1/2 Max 24 1/2 1 11/16 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 4

4. Install the conduit and run the low voltage 24V AC/DC Power Wires. Connect the 24V AC/DC power wires to the Wire Adapter LED-TC-B-2L with the provided wire nuts. Tuck all wires into the Junction Box for later use. Junction Box 1/2 Condult From remote power supply Wire Nuts Wire Adapter LED-TC-B-2L WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 5

5. Check all wiring connections and make sure all wiring is done as instructed. Plug in the Tape Light Strip and turn on the power to ensure the lights are working properly. Remove the tape light strip for later use if it is powered properly. Tape Light Strip WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 6

6. Mark a 4 3/8 x 3 rectangle on the drywall where the junction box will be located. Cut out the marked rectangle using a jabsaw or Rotozip tool. Mount the drywall to the studs. Using the drywall opening as reference, mark 4 3/8 wide lines and cut the desired length of the channel along the drywall. Mark the location of the Studs for later use. In any cases where no stud/joist is present, LED-T-CH-PER may be used to secure the channel to the dry wall. Mount LED-T-CH-PER with two #8 Wood Screws 5 apart centered around the cutout. LED-T-CH-PER should be spaced in 2 feet. 1/2 Thick Drywall Studs 2 ft TYP Mark Center of LED-T-CH-PER Drywall Cutout LED-T-CH-PER 3 4 3/8 Cutout Centerline LED-T-CH-PER (Perfoated Metal Sheet) #8 Wood Screws (Provided) WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 7

7. Insert the End Cap & Channel Section from LED-T-RBOX3-WT to the power feed side & insert one End Cap from LED-T-RBOX3-WT to the opposite side temporarily. Measure the LENGTH OF CHANNEL in between precisely. Write the number down on a paper. Remove the End Caps and Channel Section from the drywall. Channel Section (from LED-T-RBOX3-WT) End Cap (from LED-T-RBOX3-WT) End Cap (from LED-T-RBOX3-WT) Length of channel () 8. If required for installation, cut down to measured/desired length with hacksaw or miter saw that has an appropriate blade for cutting aluminum. Always wear safety goggles when cutting. (Note: Channel should be cut together with the diffuser to ensure proper fitting.) WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 8

9. Insert LED-T-CH-JOIN half way into the slots of each channel end and butt the channels against each other. Lock the channels tightly together and secure them with the provide hex key. Mount the LED-T-CH-END3-WT to the end of the channel. Push the whole channel assembly into the drywall cutout. Mount the channel assembly to the Junction Box with End Cap Screw and Channel Section Screw. LED-T-CH-JOIN LED-T-CH-END3-WT Hex Key (Provided) Spacers LED-T-CH-END3-WT Channel Section Screws WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 9

10. Make sure channel is aligned straight using a laser level. Use the Marked Stud Locations on the drywall and the Channel Grooves, carefully drill (LED-T-CH-BIT) and countersink (LED-T-CH-SINK) the channel. Properly secure the channel to the drywall using drywall screws. Make sure all screw heads are flush with the channel surface for plaster work later. Stud Marking Channel Grooves Drill and Countersink WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 10

11. Cover up the opening section of the channel with the provided Foam to prevent plaster and dust entering the channel. Apply ultra-thin drywall tape along edges of the channel to prevent cracking of plaster after installation. Note: Do not overlap drywall tapes. Plaster the channel edges to the drywall. Sand and paint the wall properly. After the plaster cures, remove the Foam and clean the inside of the channel before installing the LED Tape Light Strip. Foam Plaster Channel Plaster Drywall Drywall Stud Drywall Tape & Plaster Foam Channel Drywall Tape & Plaster WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 11

12. Pull out the LED-TC-B-2L from Junction Box. Plug the Tape Light Strip into the Wire Connector. Tuck the wire connector back to the junction box. Removing the backing from the tape light strip and install it inside the channel by using your fingers Make sure to push the connector as close to the end of the channel as possible to eliminate dark spot at the beginning of the run. Make sure that the tape light strip is firmly attached to the channel. Note: There are two positions for installing the tape light strips. Tape light strips can be installed at either position. Or two strips can be installed at the same time. After trimming the tape light strip on cuttable section, place the excess strip behind the drywall through the End Cap Opening. End Cap Opening LED-TC-B-2L Excess Strip Tape Light Strip Tape Light Strip Must be installed Here WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 12

13. Screw the Channel Cover back to the channel. Turn on the power and the installation is finished. Channel Inner Cover 1 Channel Inner Cover 2 Channel Inner Cover Screws Channel Outer Cover Channel Outer Cover Screws 14. General Wiring Diagram Remote Remote Remote 277V (60W) (100W) EN-24100-277-RB2-T (100W) 120 VAC 277 VAC INPUT Black White Black Dimmer Strip White Black White Red Red Extended Wire Extended Wire WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. July, 2016 13