Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

v3 360 Passive Infrared Line Voltage Occupancy Sensor

with Light Level, Isolated Relay and Manual On features

Installation Instructions

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

High/Low Bay Passive Infrared Occupancy Sensor

No: /18 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Smart Task Motion Activated Task Light Installation Manual

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

No: /16 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación UNIT DESCRIPTION

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Installing the FSP-211 Sensor in Light Fixture

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

WARNING: Do not work around outlets while the power is on. Do not stick fingers or tools into an electrical box while the power is on.

Wireless Occupancy Sensor User Guide

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

ETC Installation Guide

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE

ODSOD-ID. D u a l - R e l ay Decora Wall Sw i t c h Occupancy Sensor

Indoor Contact Input Photosensor

Installation Instructions

Mini Sensor. Outdoor Motion Sensor. Installation Manual

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

STL200/277 Installation Manual STL200/277

STL200/277 Installation Manual STL200/277

LASER ENHANCED REVOLVER GRIP OWNER S MANUAL RED LASER GREEN LASER

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

Dual Technology Wall Mount Occupancy Sensor

3000W multi Pir light controller

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

Dual Technology Wall Mount Occupancy Sensor

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE LED SURFACE AMBIENT LUMINAIRE FACTORY SETTINGS. Configuration Value

STEALTH. STL200 Installation Manual. Specifications: STL200 STL200H STL200HB. Switching Capacity: 8 amps

SmartBox RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to all your outdoor lights! Contents.

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

Infrared Wall Mount Occupancy Sensor

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

DW200W Dual Tech Relay Wall Switch Sensor

Broadband Step-Up Transformer. User Manual

3000W MULTI PIR LIGHT CONTROLLER

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

STEALTH. STL110 Installation Manual. Specifications: STL110 STL110HB STL110H STL110R. Switching Capacity:

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual

SELECTIVE CALL INTERCOM SYSTEM MODEL: IM-5000 MASTER STATION

For Precise Volume Adjustment with Programmable Muting in Any Room

Energy Savings Material Savings Minimize Costs Ideal Uses

Tuff Dome. Installation Manual. vandal resistant. Outdoor Motion Sensor. Contents. Specifications. Switching Capacity:

Smart Post RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to your post lantern! Contents.

Wireless Ceiling Mount Sensor

* * APPLICABLE MODELS: 2014 > MAZDA 3

Installation Manual. Specifications: Cautions: TURN OFF ALL POWER AT CIRCUIT BREAKER / FUSE PANEL.

PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions

GPS Wireless Clock System User Manual. Synchronized Solutions for every type of facility SCHOOLS HEALTHCARE GOVERNMENT INDUSTRIAL CORPORATE

Acu-Park TM. user s guide Directed Electronics, Inc. Vista, CA N9100T 09-04

Energy Saving Module (HG-ESM-01)

Technical Application Guide

RK-CH4-4 Methane Transmitter Operator s Manual

DAZZLE ACCENT LIGHTING SYSTEM

COOLEDGE TILE GEN2 INTERIOR-TUNABLE WHITE INSTALLATION MANUAL

Dual Technology Ceiling Mount Sensor

Owner s Manual.

TekLink TL100 with Passive Infrared Sensing System Overview

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

LLK-AR45 LED Lighting Heatsink Enclosure Kit. LLK-AR45 LED Illuminator Heatsink Enclosure Kit

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

VSOS VMOS. 100 WATT HIGH POWER STEREO VOLUME CONTROL w/override. 100 WATT HIGH POWER MONO VOLUME CONTROL w/override

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

BCV-1203 Barcode Verification System Users Guide Version 1.2

plifier D-501 otion Am Tactile M

WALTx-2 Instruction Manual Weatherproof Volume Control

8 Channel, DMX to 0 10 volt, Decoder board

BFS / BFSM SERIES Installation & Maintenance Manual

Installation Manual. The STEALTH 360 is the most reliable and technically advanced motionactivated

4S, 5S, 5A, 6S, 6A, 8S, 9S, 10S, 10A, 26S, 29S, 35S, 35A, 36S,

Occupancy Sensors for High-Bay Applications

RK Hydrogen Transmitter Operator s Manual

MaxLite Linear Strip ECO Series

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

INSTALLATION & OPERATION GUIDE. SVC100R High-Power Sliding Volume Control

SMARTBULLET SMSBULLET2X12

GE Lighting. control. Aware Occupancy and Photo Sensors

FFLED18 INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS WARRANTY

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

Transcription:

SPECIFICATIONS WS-200 Automatic PIR Wall Switch Voltages...........................120 or 277VAC, 60Hz Requirements @ 120VAC, 60Hz........0-800W ballast & tungsten @ 277VAC, 60Hz.................0-1200W ballast @ 120 or 277 VAC........................1/6 hp Time Delay Adjustment............30 seconds-30 minutes Sensitivity Adjustment...............Minimum-Maximum Light Level Adjustment....................10 150 + FC US Patent No s: 4,787,722 4,874,962 5,124,566 Installation Instructions

UNIT DESCRIPTION AND OPERATION The WS-200 Automatic Wall Switch turns lighting systems on and off based on occupancy and light levels and is designed to replace the standard light switch. The sensor uses passive infrared technology to sense human motion in a space and control the lighting. It must have a clear view of the people in the space in order to detect occupancy. Obstructions, such as furniture blocking the sensor s lens, may prevent occupancy detection. Pressing the Auto/Off switch from off to auto will turn lights on. Once the space is vacant and the time delay elapses (adjustable from 30 seconds to 30 minutes), lights will turn off. Once lights are off, the sensor will turn the lights on when it detects occupancy. However, if adequate daylight is present, the sensor will hold lights off until natural light levels drop regardless of occupancy. Users can override this function by placing their hand in front of the sensor. The lights will then remain on until the space is unoccupied. The LED blinks upon initial motion detection and then resets, waiting for a period of inactivity. It will blink again upon a change of infrared energy in the space. Call 800.879.8585 for Technical Support

COVERAGE PATTERNS The WS-200 detects motion in areas up to 900 sq. ft. and up to 35 feet from the sensor. Ideally, the sensor is designed for small amounts of motion in spaces up to 300 sq. ft. The Fresnel lens on the sensor is a multiple segment viewing lens with a field of view of 180. 35' (10.7m) 15' 4.0' (1.2m) floor 35' (10.7m) Masking the lens Opaque adhesive tape is supplied so that sections of the sensor s view can be masked. This allows you to eliminate coverage in unwanted areas. Since masking removes bands of coverage, remember to take this into account when troubleshooting coverage problems.

INSTALLATION CAUTION TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE INSTALLING THE SENSOR. WS-200 Automatic Wall Switch Wall Junction Box Cover plate 1. Remove the button cover to access controls by gently pressing down the security tab on top and prying off with a small screw driver. (See Sensor Adjustment ) 2. Set the AUTO/OFF switch to the OFF position. (OFF=button out; AUTO=button in) 3. Connect the existing wires to the sensor terminals. (See Wiring Directions at right). Do not allow bare wire to show below connector. The ground wire must be tightly grounded for the unit to operate properly. 4. Attach the sensor to the wall by mounting it in the wall box with the two mounting screws provided. Note: Do not install cover plate until control adjustments are made. 5. Turn power on at the circuit breaker. 6. Press the AUTO/OFF switch to Auto (in). 7. Replace cover plate. IMPORTANT: There is an initial warm-up period. It may take up to a minute before the lights turn on due to a sensor warm-up period required during initial power-up (this occurs during installation only). IMPORTANT: Rapid successive pressing of the AUTO/OFF switch causes a delay in proper function. Call 800.879.8585 for Technical Support

WIRING DIRECTIONS For normal installation of the WS-200, connect: 1. LOAD to terminal. 2. LINE to Line terminal. 3. GROUND to GROUND terminal. Ground Neutral Line Single-level wiring Neutral Ground Line Manual bi-level lighting wiring Insert or wrap wire as shown and tighten screw in the clockwise direction. Strip Gauge #12 #14 AWG Cu Wire Only

SENSOR ADJUSTMENT WARNING DO NOT OVERTURN TRIMPOTS WHEN ADJUSTING THE SENSOR! 1. Remove the switch cover to access controls by gently prying it off from the top with a small screw driver. 2. To test unit operation, press Auto-off switch IN (Auto position) to turn lights on. Turn time delay to minimum (counterclockwise), leave the room and the lights should go off after 30 seconds. 3. To test sensitivity, make no motion for 10 seconds. This 10 second (no movement) time period must be observed in order for the LED to charge. Then move in a sideways motion in front of the sensor at a distance of approxi-mately 12. The LED will blink when movement is detected. Typically, the sensitivity should be at maximum (clockwise). Auto-off Switch Override (L) Light Level (T) Time-Delay (S) Sensitivity LED Fresnel Lens Press down on tab and pry-off Cover Switch Cover Maximum = clockwise Minimum = counter-clockwise 4. The light level setting must be set when the lights would normally be turned off due to the presence of sufficient natural or external light. [If this feature is not needed, leave the light level adjustment at maximum (clockwise)]. Adjust the light level to minimum and let the sensor time out so lights are off. Enter the space and lights should remain off. Make sure your body does not cast a shadow on the sensor, and adjust the light level trimpot clockwise in small increments. After each adjustment, wait 5-10 seconds to see if the lights turn on. Continue this procedure until the lights turn on. At this setting the lights will not turn on if light levels are above the current natural illumination. 5. Reset the time delay to the desired setting. The time delay can be set from 30 seconds to 30 minutes.

TROUBLESHOOTING Lights will not turn on: LED does not flash: - Check the sensitivity for proper configuration. - Check all wire connections and verify the ground wire is tightly secured. LED does flash: - Press the AUTO/OFF button. - Check all wire connections and verify the load wire is tightly secured. If lights still do not turn on, call (800) 879-8585 for technical support. Lights will not turn off: Note: The time delay can be set from 30 seconds to 30 minutes. Ensure that the time delay is set to the desired delay and that there is no movement within the sensor s view for that time period. To quickly test the unit for proper operation, turn the time delay to minimum and move out of the sensor s view. Lights should turn off after 30 seconds. If lights still do not turn off, call (800) 879-8585 for technical support. Sensing motion outside detection areas: An opaque adhesive tape is included with the sensor and can be used to limit the detection areas. Adjust sensitivity counter-clockwise to reduce excessive sensitivity. Override function: In the event of unit failure or if it is necessary to leave the lights on, remove the override jumper. This will convert the AUTO/OFF switch into a standard ON/OFF toggle switch. There is an initial warm-up period: It may take up to a minute before the lights turn on due to a sensor warm-up period required during initial power-up (this occurs during installation only). Rapid successive pressing of the AUTO/OFF switch will cause a delay in proper function: If this is done, it may take several seconds for the switch to turn on the lights. Call 800.879.8585 for Technical Support

ORDERING INFORMATION Catalog # WS-200 ASP-211 ASP-422 ASP-432 Description Automatic Wall Switch, 120 or 277 VAC, 60Hz Cover Plate for single-gang box Blank cover plate for 2-gang box Cover plate for 2-gang box with switch option All units are available in Ivory (-I), White (-W), Gray (-G), Black (-B), and Light Almond (-A). Add color designator to end of catalog number when ordering. One ASP-211 is included with each unit. COVER PLATES The Watt Stopper automatic wall switch fits behind industry standard decorator style switch plates. The Watt Stopper has available both single and double gang switch plates in most configurations. Consult catalog or your distributor for more information. WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Watt Stopper/Legrand for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. 2800 De La Cruz Boulevard, Santa Clara, CA 95050 Technical Support: 800.879.8585 972.578.1699 www.wattstopper.com 01593r4 02/2005