Single Fiber 1.25Gbps Bi-directional Optical Transceiver SFP with Digital Diagnostics

Similar documents
Singlemode 155Mbps Optical Transceiver SFP with Digital Diagnostic

Multimode 155Mbps Optical Transceiver SFP with Digital Diagnostic

Singlemode 622Mbps Optical Transceiver SFP with Digital Diagnostic

Multimode 1.25Gbps 850nm Optical Transceiver SFP with MSA

Singlemode 1.25Gbps Optical Transceiver SFP with MSA

Singlemode 155Mbps Optical Transceiver SFP with MSA

Fiber Channel 2.125Gbps Multimode Optical Transceiver SFP with MSA

155Mbps 850nm Multimode Optical Transceiver Small Form Pluggable (SFP)

Multi-mode 1.25Gbps 780/850 Bi-Directional Single Fiber SFP Optical Transceiver

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

RoHS Compliant SFP Transceiver for ATM, SONET OC-3/SDH STM-1 with Digital Diagnostic Monitoring Function

RoHS Compliant SFP Transceiver for SONET OC-48/SDH STM-16 with Digital Diagnostic Monitoring Function

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

LCP-1250A4FDRx RoHS Compliant Multimode SFP Transceiver for GbE and Fiber Channel

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

AC05-A13L6-02 (-DD) 155Mbps SFP Optical Transceiver, 2km Reach

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel

GPB-5324L-L8CD 1.25Gbps SFP Bi-Directional Transceiver, 80km Reach 1550nm TX / 1310 nm RX

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

PT (2)-1W(+) GbE 1000Base-LX 10 km SFP Transceiver

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

1/12. SFP модули. Модели SFP-DWDM-GE-15xx.xx-28. Особенности: - 100Mbps Gbps - встроенная функция диагностики (DDMI)

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

T S D S x C B 1 K 1 1

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

CWDM SFP 1.25G 40KM LC Duplex

Shenzhen Hilink Technology Co.,Ltd

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

T B B S x C D 2 G A M

1.25Gbps SFP Optical Transceiver, 550m Reach

AOP-324-R20(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

GP-5524-L8x(D) 1.25Gbps SFP Optical Transceiver, 80km Reach

LX21 100Mb/s to 1.25Gb/s BX-U

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

AXGE Gbps Single-mode 1310nm, SFP Transceiver

155Mb/s Hot Pluggable, Duplex LC, +3.3V, 1310nm, FP-LD, Multi-Mode SFP Optical Transceiver with DDMI PSFP M-22F

1.25Gbps SFP Optical Transceiver, 550m Reach

GP C(D) 155Mbps SFP Optical Transceiver, 2km Reach

PTB38J0-6538E-SC/PC. GPON Class B+ SFP OLT Transceiver with Digital RSSI

1G SFP CWDM nm 80km Optical Transceivers

XSS311-20LY. 1.25Gbps SFP Optical Transceiver, 20km Reach. Features. Applications. Description

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

1.25Gbps Single Fiber Bi-directional SFP, ONU Transceiver

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

RoHS Compliant Multi-Rate CWDM SFP Transceiver for SONET OC-48/SDH STM-16 with DDM Function

GLC-SX-MMD (1000BASE-SX SFP) Datasheet

622Mbps SFP Optical Transceiver, 40km Reach FS-622M-A40

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

2 Mb/s IEEE C37.94 Multi-Mode Transceiver

GPBC-xxxx24L-04CD 1.25Gbps SFP CWDM Bi-Di Single Fiber Transceiver, 40km Reach

2 10 SFF GPON ONU HYG-F CX

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

Optical Transceiver Module - SFP

Product Features. Applications. Descriptions. Ordering Information. Pin Description

SFP Optical Transceivers

Product Features Applications Descriptions Ordering Information

TRPUFEALXx000E1G Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers With Digital Diagnostics

SFP-LX 1.25Gb/s Single-Mode SFP Transceiver 1000BASE-LX Gb/s Fiber Channel

4.25 Gb/s Fibre Channel Single Mode Transceiver

GPON OLT Optical Module

GP-3124-L2x(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

125Mbps~155Mbps Multimode 850nm, SFP Transceiver

GPB-4324x-L4x(D) 1.25Gbps SFP Bi-Directional Transceiver, 40km Reach 1490nm TX / 1310 nm RX

T A S A 5 N B 1 F A H

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

GPON OLT Optical Module

Specification. Small Form Factor Pluggable Duplex LC Receptacle SFP. Optical Transceivers 1000BASE-SX 1250Mbit/s. Ordering Information

Features. RX Sensitivity (dbm) TX Power (dbm) Voltage (V) SFP-Dual-LC 1.25G MMF 2Km ~ -9 < AC/AC TTL N -5 ~ +70 A56L-BN13-A6MA

GPON OLT C++ Optical Module

Multi-rate Gigabit Ethernet & Fibre Channel SFP Transceivers with Digital Diagnostics

OCTECH 1.25Gbps SFP Transceiver

2.67Gbps CWDM SFP Optical Transceiver, 40km Reach GPC-xx48-04X(D)

TPP3XGDS0x000E2G 850nm SFP+ Transceiver

SFP-GE-LX Gigabit Ethernet-Singlemode Transceiver SFP, Duplex LC Connector, 1310nm DFB 40km for Single Mode Fiber, RoHS Compliant

Standard Operating Temperature: -10 C ~ 70 C. Parameter Symbol Min. Max. Unit Note

HOLT Transceiver for GE-PON (HOLT-11C214L31) SFP with SC receptacle, +3.3V 1490nm, DFB-LD. Feature. Applications. Description

Specification. T B D - S x D B 1 - F 1 1

10Gb/s SFP+, Hot Pluggable, Duplex LC, +3.3V, 1310nm, Single Mode, 10km, DFB Optical Transceiver PSFP SF

DWDM SFP 2.5G 120KM LC Duplex SLSD-25XX-120-D

4.25Gbps SFP Transceiver

10G SFP+ CWDM 20km Transceiver Hot Pluggable, Duplex LC, +3.3V, 1270~1350nm CWDM DFB, DDMI PSFP-2C41SF-XX

OCTECH 1.25Gbps SFP Transceiver

TRPUFEEEXx000E1G Fast Ethernet 100Base SFP Transceiver With Digital Diagnostics

Applications High-speed Storage Area Networks Computer Cluster Cross-connect Custom High-speed Data Pipes

Product Specification. SFP OLT 1G 20km SC. 1.25Gbps Upstream/1.25Gbps Downstream GE-PON OLT Transceiver. SFP OLT 1G 20km SC

BC-BL 35(53)12-20 SFP BIDI 1.25G 1310/1550nm (1550/1310nm) DDM 20KM Transceiver

3.3V / 1550 nm / 1.25 Gbps Digital Diagnostic LC SFP SINGLE-MODE TRANSCEIVER

SFP M~2.67Gbps SFP Optical Transceiver, 300m Reach

DWDM SFP Optical Transceiver

155Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

PART NUMBER: SFPT-ZX8-01 PRODUCT FEATURES

Single-mode 1.25Gbps 2X10 SFF Transceiver

Transcription:

SFP with Digital Diagnostics Features Compliant with SFP MSA and SFF-8472(Rev 9.3) Compliant with IEEE 82.3z Gigabit Ethernet 1BASE-LX specification SFF-8472 Digital Diagnostic Monitoring Interface with real time monitors - Transmitter Output Power - Receiver Input Power - Laser Bias Current - Temperature - Supply Voltage Internal calibration for Digital Diagnostic Monitoring Alarms and warnings to indicate status of real time monitors Metal case & LC receptacle with bail de-latch Transmitter disable input and receiver loss of signal output Wide operating temperature range 4 ~85 Single 3.3V power supply AC coupled LVPECL compatible data input and output 2-wire serial EEPROM protocol Specifications Parameter Symbol Min. Typ. Max. Unit Transmitter Data Rate (NRZ) B - 125 - Mb/s Optical Output Power (avg.) (1) (2) (3) -1 P o -11 - -6 dbm -2 P o -5 - -3 dbm -3 P o -1 - - dbm Extinction Ratio (2) ER 9 - - db Optical Wavelength 131nm FP LD (2) λ C 127 131 1355 nm 155nm DFB LD λ C 153 155 157 nm Spectral Width 131nm FP LD (RMS) (2) Δλ - - 2.5 nm 155nm DFB LD (-2dB) Δλ - - 1 nm Side Mode Suppression Ratio 155nm DFB LD SMSR 3 - - db Output Rise Time (2-8%) (2) t r - - 26 ps Output Fall Time (2-8%) (2) t f - - 26 ps Data Differential Input Voltage V i 5-24 mv p-p V TX Fault Output Voltage FOL -.4 V V FOH 2.4 - Vcc 1

SFP with Digital Diagnostic Parameter Symbol Min. Typ. Max. Unit V TX Disable Input Voltage DIL -.8 V V DIH 2 - Vcc Supply Voltage Vcc 2.97 3.3 3.63 V Supply Current Icc - - 15 ma Receiver Data Rate (NRZ) B - 125 - Mb/s Optical Input Sensitivity (avg.) (1) (2) (5) -1 P IN - - -2 dbm -2 P IN - - -23 dbm Saturation (avg. power) P SAT -3 - - dbm Optical Wavelength λ 11-16 nm Output Rise Time (2-8%) t r - - 25 ps Output Fall Time (2-8%) t f - - 25 ps Data Differential Output Voltage V o 37-2 mv p-p LOS Deasserted Power Level (avg.) P A - - -2 dbm LOS Asserted Power Level (avg.) P D -36 - - dbm LOS Hysteresis P HYS.5 3 - db V LOS Output Voltage LOS-OL -.4 V V LOS-OH 2.4 - Vcc Supply Voltage Vcc 2.97 3.3 3.63 V Supply Current Icc - - 13 ma Notes: (1) With.275 NA, 9/125μm fiber. (2) Compliant to IEEE82.3z Gigabit Ethernet 1BASE-LX. (3) Class 1 eye safe per FDA and IEC. (4) Transmitter eye mask diagram is compliant to IEEE82.3z Eye Diagram. (5) 2 7-1 PRBS, BER= 1-12. (6) The transmitter output should not be viewed directly. Absolute Maximum Ratings Parameter Min. Max. Unit Operating Temperature -1 7 C -2-4 85 C Storage Temperature -4 1 C Lead Soldering Limits - 24/1 C /sec Supply Voltage -.5 4 V Digital Diagnostic Monitor Characteristics Parameter Min. Unit Transceiver Internal Temperature Accuracy ±3. C Transceiver Internal Supply Voltage Accuracy ±3 % TX Laser Bias Current Accuracy ±1 % TX Average Output Power Accuracy ±3. db RX Average Input Power Accuracy ±3. db 2

SFP with Digital Diagnostics Timing of Control and Status I/O Parameter Symbol Min. Max. Unit Condition TX Disable Assert Time from rising edge of TX Disable to when the t_off 1 μs Time optical output falls below 1% of nominal. Time from falling edge of TX Disable to when the TX Disable Negate t_on 1 ms modulated optical output rises above 9% of Time nominal. Time to initialize, including reset of TX_Fault t_init 3 ms From power on or negation of TX Fault using TX Disable. TX Fault Assert Time t_fault 1 μs Time from fault to TX fault on. TX Disable to reset t_reset 1 μs Time TX Disable must be held high to reset TX_fault. LOS Assert Time t_loss_on 1 μs Time from LOS state to RX LOS assert. LOS Deassert Time t_loss_off 1 μs Time from non-los state to RX LOS deassert. Serial ID Clock Rate f_serial_clock 1 khz Ordering Information T R R - 3 R L C 3 M F D Operating Temperature Range: 1: C ~ 7 C 2:-4 C ~ 85 C Sensitivity Grade: 1:-1 2:-2 3:-3 Tx Output Power Grade: 1:-1 2:-2 3:-3 Wavelength: 13:131nm FP LD 31:131nm DFB LD 15:155nm FP LD 55:155nm DFB LD 3

SFP with Digital Diagnostic Part Number Laser Type Power Budget (1) Recommended Maximum Reach (2) Compliant to Gigabit Ethernet (4) TR13R55-311RLC3MF D 131nm, FP TR55R13-311RLC3MF D 155nm, DFB 9dB 2Km 1BASE-LX TR13R55-321RLC3MF D 131nm, FP TR55R13-321RLC3MF D 155nm, DFB 15dB 4Km - TR13R55-332RLC3MF D 131nm, FP TR55R13-332RLC3MF D 155nm, DFB 22dB 7Km - Notes: (1) Power Budget (min.) = TX Output Power (min.) - RX Sensitivity (max.) (2) Assuming connector loss 2dB; 131nm fiber attenuation coefficient.3db/km; 155nm fiber attenuation coefficient.25db/km. (3) The maximum reach value is recommended, not guaranteed. The exact transmission distance depends on fiber loss, connector loss and system penalty. (4) Gigabit Ethernet standard specification is defined in IEEE82.3z. 4

SFP with Digital Diagnostics Outline Drawing SFP Transceiver Electrical Pad Layout UNIT:mm Pin2 VeeT Pin 1 VeeT Pin19 TD- Pin 2 TX Fault Pin18 TD+ Pin 3 TX Disable Pin17 VeeT Pin 4 MOD-DEF2 Pin16 VccT Pin 5 MOD-DEF1 Pin15 VccR Pin 6 MOD-DEF Pin14 VeeR Pin 7 NC Pin13 RD+ Pin 8 LOS Pin12 RD- Pin 9 VeeR Pin11 VeeR Pin1 VeeR Top of Board Bottom of Board (as viewed Thru top of board) 5

SFP with Digital Diagnostic Pin Description Pin No. Symbol Description 1 VeeT Transmitter Ground 2 TX Fault Transmitter Fault Indication Logic Low indicates normal operation. Logic High Indicates a laser fault of some kind. TX Fault is an open drain output, which should be pulled up with a 4.7K 1KΩ resistor on the host board. Transmitter Disable Its states are: Low (.8V) :Transmitter on 3 TX Disable (>.8, < 2.V) :Undefined High (2. 3.465V) :Transmitter Disabled Open :Transmitter Disabled It is pulled up within the module with a 4.7K 1 K.Ω resistor. Module Definition 2 (SDA) 4 The data line of two wire serial interface for serial ID. MOD-DEF2 MOD-DEF2 should be pulled up with a 4.7K 1KΩresistor on the host board. The pull-up voltage shall be VccT or VccR. Module Definition 1 (SCL) 5 The clock line of two wire serial interface for serial ID. MOD-DEF1 MOD-DEF1 should be pulled up with a 4.7K 1KΩresistor on the host board. The pull-up voltage shall be VccT or VccR. 6 Module Definition (WP) MOD-DEF MOD-DEF is grounded by the module to indicate that the module is present. 7 NC Not connected 8 LOS Loss of Signal Logic High indicates the received optical power is below the worst-case receiver sensitivity. Logic Low indicates normal operation. LOS is an open drain output, which should be pulled up with a 4.7K 1KΩ resistor on the host board. 9 VeeR Receiver Ground 1 VeeR Receiver Ground 11 VeeR Receiver Ground 12 RD- Inv. Received Data Out (Note 1) 13 RD+ Received Data Out (Note 1) 14 VeeR Receiver Ground 15 VccR Receiver Power Supply 16 VccT Transmitter Power Supply 17 VeeT Transmitter Ground 18 TD+ Transmitter Data In (Note 2) 19 TD- Inv. Transmit Data In (Note 2) 2 VeeT Transmitter Ground Notes: 1. RD+ and RD- are AC coupled 1Ω differential lines which should be terminated with 1Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 37 and 2 mv differential (185 1 mv single ended) when properly terminated. 2. TD+ and TD- are AC-coupled, differential lines with 1Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 5 24 mv (25 12 mv single-ended), though it is recommended that values between 5 and 12 mv differential (25 6 mv single-ended) be used for best EMI performance. 6

SFP with Digital Diagnostics Recommended Host Board Supply Filtering Network VccT.1uF 1uH VccR.1uF 1uF 1uH.1uF 1uF 3.3V SFP Module Host Board Example SFP Host Board Schematic Protocol Vcc Protocol Vcc 3.3V 1uH Vcc,T SFP Module 4.7KΩ to 1KΩ 1uF.1uF 1uH.1uF 4.7KΩ to 1KΩ TX Disable TX Fault TX Disable TX Fault TD+.1uF TD- 1Ω Laser Driver LD Protocol IC SerDes IC 4.7KΩ to 1KΩ GND,T Vcc,T.1uF 1uF.1uF RD+.1uF 1Ω Preamp & Quantizer PD RD- RX LOS 3.3V RX LOS GND,R.1uF 4.7KΩ to 1KΩ 4.7KΩ to 1KΩ 4.7KΩ to 1KΩ MOD-DEF MOD-DEF1 MOD-DEF2 PLD/PAL 7

SFP with Digital Diagnostic Memory Map 8

SFP with Digital Diagnostics EEPROM Serial ID Memory Contents (Ah) Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII 3 32 2 64 96 2 1 4 33 2 65 1A 97 2 2 7 34 2 66 98 2 3 35 2 67 99 2 4 Note1 36 68 1 2 5 Note1 37 2 69 11 2 6 38 2 7 12 2 7 39 2 71 13 2 8 4 54 T 72 14 2 9 41 52 R 73 15 2 1 42 Note1 * 74 16 2 11 5 43 Note1 * 75 17 2 Note3 12 2 44 53 S 76 18 2 13 45 4D M 77 19 2 14 Note1 46 33 3 78 11 2 15 Note1 47 2D - 79 111 2 16 Note1 48 Note1 * 8 112 2 17 Note1 49 Note1 * 81 113 2 18 5 4C L 82 114 2 19 51 43 C 83 115 2 2 41 A 52 33 3 84 116 2 21 5 P 53 4D M 85 117 2 22 5 P 54 52 R 86 118 2 23 4F O 55 Note1 * 87 119 2 Note4 24 49 I 56 46 F 88 12 2 25 4E N 57 2 89 121 2 26 54 T 58 2 9 122 2 27 45 E 59 2 91 123 2 28 43 C 6 Note1 92 68 124 2 29 48 H 61 Note1 93 B 125 2 3 2 62 94 1 126 2 31 2 63 Note2 95 Note2 127 2 Notes: 1. Data will vary depends on product. 2. Addresses 63 is check sum of bytes 62. Addresses 95 is check sum of bytes 64 94. 3. These addresses are reserved for serial number information. 4. These addresses are reserved for date code information. 5. The data transfer protocol and complete description of Ah memory contents are defined in SFP MSA and SFF-8472. 9

SFP with Digital Diagnostic Digital Diagnostic Alarm and Warning Thresholds (2-Wire Address A2h) Address #Bytes Name Description Value -1 2 Temp High Alarm MBS at low address 1 C 2-3 2 Temp Low Alarm MBS at low address -4 C 4-5 2 Temp High Warning MBS at low address +85 C 6-7 2 Temp Low Warning MBS at low address -35 C 8-9 2 Voltage High Alarm MBS at low address 3.9V 1-11 2 Voltage Low Alarm MBS at low address 2.7V 12-13 2 Voltage High Warning MBS at low address 3.63V 14-15 2 Voltage Low Warning MBS at low address 2.97V 16-17 2 Bias High Alarm MBS at low address 7mA 18-19 2 Bias Low Alarm MBS at low address 4mA 2-21 2 Bias High Warning MBS at low address 6mA 22-23 2 Bias Low Warning MBS at low address 5mA 24-25 2 TX Power High Alarm MBS at low address Note 26-27 2 TX Power Low Alarm MBS at low address Note 28-29 2 TX Power High Warning MBS at low address Note 3-31 2 TX Power LOW Warning MBS at low address Note 32-33 2 RX Power High Alarm MBS at low address Note 34-35 2 RX Power Low Alarm MBS at low address Note 36-37 2 RX Power High Warning MBS at low address Note 38-39 2 RX Power Low Warning MBS at low address Note Reserved for future monitored 4-55 16 Reserved quantities. Note:Data value will vary depends on product. 1

SFP with Digital Diagnostics Calibration constants for External Calibration Option (2-Wire Address A2h) Value Address #Bytes Name Description (Note) 56-59 4 Rx_PWR(4) 6-63 4 Rx_PWR(3) 64-67 4 Rx_PWR(2) 68-71 4 Rx_PWR(1) 72-75 4 Rx_PWR() 76-77 2 Tx_I(Slope) 78-79 2 Tx_I(Offset) 8-81 2 Tx_PWR(Slope) 82-83 2 Tx_PWR(Offset) 84-85 2 T (Slope) 86-87 2 T (Offset) 88-89 2 V (Slope) 9-91 2 V (Offset) Single precision floating point calibration data - Rx optical power. Single precision floating point calibration data - Rx optical power. Single precision floating point calibration data, Rx optical power. Single precision floating point calibration data, Rx optical power. Single precision floating point calibration data, Rx optical power. Fixed decimal (unsigned) calibration data, laser bias current. Fixed decimal (signed two s complement) calibration data, laser bias current. Fixed decimal (unsigned) calibration data, transmitter coupled output power. Fixed decimal (signed two s complement) calibration data, transmitter coupled output power. Fixed decimal (unsigned) calibration data, internal module temperature. Fixed decimal (signed two s complement) calibration data, internal module temperature. Fixed decimal (unsigned) calibration data, internal module supply voltage. Fixed decimal (signed two s complement) calibration data, internal module supply voltage. 1 1 1 1 1 92-94 3 Reserved Reserved 95 1 Checksum Byte 95 contains the low order 8 bits of the sum of bytes 94. Notes:The device is internally calibrated. 11

SFP with Digital Diagnostic A/D Values and Status Bits (2-Wire Address A2h) Byte Bit Name Description Converted analog values. Calibrated 16 bit data. 96 All Temperature MSB 97 All Temperature LSB 98 All Vcc MSB 99 All Vcc LSB Internally measured module temperature. Internally measured supply voltage in transceiver. 1 All TX Bias MSB Internally measured TX Bias Current 11 All TX Bias LSB 12 All TX Power MSB Measured TX output power. 13 All TX Power LSB 14 All RX Power MSB Measured RX input power. 15 All RX Power LSB 16 All Reserved MSB Reserved for 1 st future definition of digitized analog input 17 All Reserved LSB Reserved for 1 st future definition of digitized analog input 18 All Reserved MSB Reserved for 2 nd future definition of digitized analog input 19 All Reserved LSB Reserved for 2 nd future definition of digitized analog input Optional Status/Control Bits 11 7 Tx Disable State Digital state of the TX Disable Input Pin. 11 6 Soft Tx Disable Read/write bit that allows software disable of laser. It is not implemented, the transceiver ignores the value of this bit. 11 5 Reserved Reserved 11 4 RX Rate Select State Digital state of the SFP RX Rate Select Input Pin. 11 3 Soft RX Rate Select Read/write bit that allows software RX rate select. It is not implemented. 11 2 TX Fault Digital state of the TX Fault Output Pin. 11 1 LOS Digital state of the LOS Output Pin. 11 Data_Ready_Bar Indicates transceiver has achieved power up and data is ready. 111 7- Reserved Reserved 12

SFP with Digital Diagnostics Alarm and Warning Flag Bits (2-Wire Address A2h) Byte Bit Name Description Reserved Optional Alarm and Warning Flag Bits 112 7 Temp High Alarm Set when internal temperature exceeds high alarm level. 112 6 Temp Low Alarm Set when internal temperature is below low alarm level. 112 5 Vcc High Alarm Set when internal supply voltage exceeds high alarm level. 112 4 Vcc Low Alarm Set when internal supply voltage is below low alarm level. 112 3 TX Bias High Alarm Set when TX Bias current exceeds high alarm level. 112 2 TX Bias Low Alarm Set when TX Bias current is below low alarm level. 112 1 TX Power High Alarm Set when TX output power exceeds high alarm level. 112 TX Power Low Alarm Set when TX output power is below low alarm level. 113 7 RX Power High Alarm Set when Received Power exceeds high alarm level. 113 6 RX Power Low Alarm Set when Received Power is below low alarm level. 113 5 Reserved Alarm 113 4 Reserved Alarm 113 3 Reserved Alarm 113 2 Reserved Alarm 113 1 Reserved Alarm 113 Reserved Alarm 114 All Reserved 115 All Reserved 116 7 Temp High Warning Set when internal temperature exceeds high warning level. 116 6 Temp Low Warning Set when internal temperature is below low warning level. 116 5 Vcc High Warning Set when internal supply voltage exceeds high warning level. 116 4 Vcc Low Warning Set when internal supply voltage is below low warning level. 116 3 TX Bias High Warning Set when TX Bias current exceeds high warning level. 116 2 TX Bias Low Warning Set when TX Bias current is below low warning level. 116 1 TX Power High Warning Set when TX output power exceeds high warning level. 116 TX Power Low Warning Set when TX output power is below low warning level. 117 7 RX Power High Warning Set when Received Power exceeds high warning level. 117 6 RX Power Low Warning Set when Received Power is below low warning level. 117 5 Reserved Warning 117 4 Reserved Warning 117 3 Reserved Warning 117 2 Reserved Warning 117 1 Reserved Warning 117 Reserved Warning 118 All Reserved 13

SFP with Digital Diagnostic Vendor Specific Memory Addresses (2-Wire Address A2h) Byte Bit Name Description 12-127 All Vendor Specific Vendor Specific User EEPROM (2-Wire Address A2h) Address #Bytes Name Description 128-247 12 User EEPROM User writable EEPROM 248-255 8 Vendor Specific Vendor specific control functions 14