LX21 100Mb/s to 1.25Gb/s BX-U

Similar documents
Product Features. Applications. Descriptions. Ordering Information. Pin Description

Product Features Applications Descriptions Ordering Information

SFP-LX 1.25Gb/s Single-Mode SFP Transceiver 1000BASE-LX Gb/s Fiber Channel

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS

Product Features. Applications. Descriptions. Ordering Information. LX432xCDR 10GEthernet 40km CWDM SFP+ Transceiver 10GBASE-LR / 10GBASE-LW

LX8501CDR 100G 100m QSFP28 Transceiver 100GBASE-SR4

FTS-S12G-B35Y-020. SFP 1000Base-LX, BiDi, 1310/1550nm, single-mode, 20km

1000Base-SX SFP Transceiver Modules (Non DDM version) WST-S8CCIV-551x

4.25 Gb/s Fibre Channel Single Mode Transceiver

XTS31U-10Lx. 10 G Ethernet 10 km SFP+ Transceiver 10GBASE-LR/10GBASE-LW. XTS31U-10Lx 10 G 10 km SFP+ Transceiver. Applications.

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS

ROHS Compliant MM SFP Transceiver 1.25Gb Gigabit Ethernet

1000Base-LX SFP Transceiver Modules (non DDM version) WST-S3CCIM-401x

Standard Operating Temperature: -10 C ~ 70 C. Parameter Symbol Min. Max. Unit Note

Product Features. Applications. Descriptions. Ordering Information. Electrical Pin Description

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

FTS-GPON-OLT-C+ GPON OLT SFP transceiver, 1490/1310nm, single-mode, RSSI, 60km

DWDM SFP 2.5G 120KM LC Duplex SLSD-25XX-120-D

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

3G Wireless Base Station SFP Transceiver Hot Pluggable, Duplex LC, 1310nm DFB, Single Mode, 15KM, DDM. Overview:

2 Mb/s IEEE C37.94 Multi-Mode Transceiver

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

CWDM SFP 1.25G 40KM LC Duplex

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

GPB-5324L-L8CD 1.25Gbps SFP Bi-Directional Transceiver, 80km Reach 1550nm TX / 1310 nm RX

DWDM SFP Optical Transceiver

SFP+ 10G Transceiver M10GB-SFP-BIDI10

DWDM SFP Series. Laser

Features. Feature Standard Performance. MIL-STD-883E Method

1.25Gbps Single Fiber Bi-directional SFP, ONU Transceiver

1/12. SFP модули. Модели SFP-DWDM-GE-15xx.xx-28. Особенности: - 100Mbps Gbps - встроенная функция диагностики (DDMI)

10Gb/s SFP+, Hot Pluggable, Duplex LC, +3.3V, 1310nm, Single Mode, 10km, DFB Optical Transceiver PSFP SF

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

PRODUCT SPECIFICATION

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

4.25Gbps SFP Transceiver

Hot Pluggable, Duplex LC, 1310nm DFB-LD, Single Mode, DDM Distance: 10KM. monitor. mode fiber

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

Single Fiber 1.25Gbps Bi-directional Optical Transceiver SFP with Digital Diagnostics

AXGE Gbps Single-mode 1310nm, SFP Transceiver

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

10G CWDM SFP+ 40km ER Transceiver Hot Pluggable, Duplex LC, +3.3V, 1470~1610nm CWDM EML, DDMI PSFP10-1C41SF-XX

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel

SFP Series. EOLS X Series. Features. Applications. Ordering Information

Optical Transceiver Module - SFP

DWDM SFP Optical Transceiver LTD-XXXX-XX

AC05-A13L6-02 (-DD) 155Mbps SFP Optical Transceiver, 2km Reach

10G SFP+ CWDM 20km Transceiver Hot Pluggable, Duplex LC, +3.3V, 1270~1350nm CWDM DFB, DDMI PSFP-2C41SF-XX

AOP-324-R20(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

OCTECH 1.25Gbps SFP Transceiver

10G SFP+ SR/SW Transceiver Hot Pluggable, Duplex LC, 850nm VCSEL, Multi Mode, 300M, DDM. Overview:

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel

10GBase SFP+ LR/LW Optical Transceivers Series WST-SFP+LR-C

AA E6-A AA E6-A. Features. Up to 1.25Gb/s Data Links. Hot-Pluggable. Duplex LC connector. Up to 10km on 9/125μm SMF

SFP CWDM 1.25G nm Single mode Optical Transceiver

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

UK - SFP MONOMODO 20 KM 1310 NM. DTS3112L - C(D)

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

1.25Gbps SFP Optical Transceiver, 550m Reach

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

GPBC-xxxx24L-04CD 1.25Gbps SFP CWDM Bi-Di Single Fiber Transceiver, 40km Reach

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

1G SFP CWDM nm 80km Optical Transceivers

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

Standard Operating Temperature: -10 C ~ 70 C

10GBase LR-Lite SFP+ Optical Transceivers (I-Temp)

10Gb/s SFP+, Hot Pluggable, Duplex LC, +3.3V, 1310nm, Multi Mode, 220m FP-LD Optical Transceiver PSFP MF

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

SFP Series. EOLS-1312-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm 1.25Gbps FC/GBE Duplex SFP Transceiver RoHS Compliant

LCP-1250A4FDRx RoHS Compliant Multimode SFP Transceiver for GbE and Fiber Channel

SFP+ Dual LC 10G SMF 10Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

LinkPower LPS SM BIDI 2612TC/2612TI & 2613RC/2613RI SC. RoHS Compliant 1.25G 1310/1550nm & 1550/1310nm 20km Transceivers

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

Features. Feature Standard Performance. MIL-STD-883E Method FDA 21CFR and EN (IEC) ,2 2002/95/EC 4.1&4.

JD061A-C. 1.25Gbps SFP Transceiver

Shenzhen Hilink Technology Co.,Ltd

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

SFP Series. EOLS-1348-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm FC/2FC/4FC Duplex SFP Transceiver RoHS6 Compliant

SPL EBX-IDFM SPL EBX-IDFM

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

SO-SFP-1000BASE-ZXD-I

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

GLC-SX-MMD (1000BASE-SX SFP) Datasheet

SFP Optical Transceivers

TRPUFEALXx000E1G Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers With Digital Diagnostics

1.25Gbps SFP Optical Transceiver, 550m Reach

10GBase SR/SW SFP+ Optical Transceivers WST-SFP+SR-C

PRODUCT SPECIFICATION

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

SFP-GE-LX Gigabit Ethernet-Singlemode Transceiver SFP, Duplex LC Connector, 1310nm DFB 40km for Single Mode Fiber, RoHS Compliant

Product Datasheet GLC-LH-SM-SE-TAA. ClearSourceIT. Product Features. Applications. Description. Statement of TAA Compliance EMC

Transcription:

Product Features Compliant with IEEE Std 802.3-2005,1000BASE- Compliant with SFF-8074i andsff-8472, revision 9.5 Compliant with SFP MSA Specification Digital Diagnostic Monitoring available Uncooled 1310nm Fabry-Perot (FP) Laser bi-directional data links Up to 20km on 9/125µm SMF Simplex LC connector compliant Single +3.3V DC power supply Hot-pluggable SFP footprint Class 1 laser safety certified Low power dissipation Operating temperature Options - (Commercial) -10 o C to +70 o C - (Industrial) -40 o C to +85 o C RoHS6 Compliant Applications 1000BASE- Fiber Channel Links: 1.0625Gb/s WDM Gigabit Ethernet Links Fast Ethernet Other Optical Links Descriptions LX2132C(I)DR SFP transceivers, according to Small Form Factor Pluggable Multi-Sourcing Agreement (MSA) SFF-8074i and SFF-8472, revision 9.5, are designed for single fiber bidirectional data communication up to 20km. They are compliant with IEEE Std 802.3-2005 1000BASE-. LX2132C(I)DR SFP transceivers offer a wide range of design options, including Digital Diagnostic Monitoring (DDM) features and temperature options (commercial or industrial). LX2132C(I)DR are compliant with RoHS6. Ordering Information Table 1. Ordering Information Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS LX2132CDR 1310nm FP -9 ~ -3dBm 1550 PIN < -23dBm 20km -10 ~ 70 o C Available Compliant LX2132IDR 1310nm FP -9 ~ -3dBm 1550 PIN < -23dBm 20km -40 ~ 85 o C Available Compliant 1

Pin Description Table 2. Pin Description Pin Name Function/Description Engagement order (Insertion) Notes 1 VeeT Transmitter Ground 1-2 TX Fault Transmitter Fault Indication 3 1 3 TX Disable Transmitter Disable-Module disables on high or open 3 2 4 MOD-DEF2 Module Definition 2-Two wire serial ID interface 3 3 5 MOD-DEF1 Module Definition 1-Two wire serial ID interface 3 3 6 MOD-DEF0 Module Definition 0-Grounded in module 3 3 7 Rate Select Not Connected 3-8 LOS Loss of Signal 3 4 9 VeeR Receiver Ground 1-10 VeeR Receiver Ground 1-11 Veer Receiver Ground 1-12 RD- Inverse Received Data out 3 5 13 RD+ Received Data out 3 5 14 VeeR Receiver Ground 1-15 VccR Receiver Power - +3.3V±5% 2 6 16 VccT Transmitter Power - +3.3 V±5% 2 6 17 VeeT Transmitter Ground 1-18 TD+ Transmitter Data In 3 7 19 TD- Inverse Transmitter Data In 3 7 20 VeeT Transmitter Ground 1 - Notes: 1. TX Fault is open collector/drain output which should be pulled up externally with a 4.7KΩ-10KΩ resistor on the host board to supply < VccT +0.3V or VccR + 0.3V. When high, this output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to <0.8V. 2. TX Disable input is used to shut down the laser output per the state table below. It is pulled up within the module with a 4.7KΩ-10KΩ resistor. Low (0 0.8V): Transmitter on Between (0.8V and 2V): Undefined High (2.0 VccT): Transmitter Disabled Open : Transmitter Disabled 3. Mod-Def 0, 1, 2. These are the module definition pins. They should be pulled up with a 4.7KΩ-10KΩ resistor on the host board to supply less than VccT+0.3V or VccR+0.3V. Mod-Def 0 is grounded by the module to indicate that the module is present. Mod-Def 1 is clock line of two wire serial interface for optional serial ID. Mod-Def 2 is data line of two wire serial interface for optional serial ID. 4. LOS (Loss of signal) is an open collector/drain output which should be pulled up externally with a 4.7KΩ-10KΩ resistor on the host board to supply <VccT+0.3V or VccR+0.3V. When high, this output indicates the 2

received optical power is below the worst case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to <0.8V. 5. RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω differential at the user SERDES. The AC coupling is done inside the module and thus not required on the host board. 6. VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V±5% at the SFP connector pin. The in-rush current will typically be no more than 30mA above steady state supply current after 500ns. 7. TD-/+: These are the differential transmitter inputs. They are AC coupled differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on host board. Figure 1. Diagram of Host Board Connector Block Pin Numbers and Names Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Table 3. Absolute Maximum Ratings Minimum imum Maximum Storage Temperature T S -40 85 o C Relative Humidity RH 5 95 % Supply Voltage V CC -0.5 4.0 V 3

Recommended Operating Conditions LX21 Table 4. Recommended Operating Conditions Min Typ Max Operating Case Temperature LX2132CDR T C -10 25 70 o C LX2132IDR T C -40 25 85 o C Supply Voltage V CC 3.135 3.3 3.465 V Data Rate - 0.1-1.25 Gb/s Transceiver Electrical Characteristics Table 5. Transceiver Electrical Characteristics Minimum Typical Maximum Module Supply Current Icc - - 220 ma - Power dissipation P D - - 800 mw - Transmitter Differential Input Voltage (TD +/-) Receiver Differential Output Voltage (RD +/-) Low speed output: Transmitter Fault(TX_FAULT) / Loss of Signal (LOS) Low speed iutput: Transmitter Disable (TX_DISABLE), MOD_DEF 1, MOD_DEF 2 Notes: 1. Internally AC coupled and terminated to 100Ω differential load. Notes - 300-2200 mv P-P 1-600 - 1200 mv P-P 2 VOH 2.0 - Vcc V 3 VOL 0-0.8 V - VIH 2.0 - Vcc V 4 VIL 0-0.8 V - 2. Internally AC coupled, but requires a 100Ω differential termination or internal to Serializer/Deserializer. 3. Pulled up externally with a 4.7KΩ-10KΩ resistor on the host board to V CCT,R. 4. Mod_Def1 and Mod_Def2 must be pulled up externally with a 4.7KΩ-10KΩ resistor on the host board to V CCT,R. Transmitter Optical Characteristics Table 6. Transmitter Optical Characteristics Minimum Typical Maximum Notes Launch Optical Power Po -9-6 -3 dbm - Center Wavelength Range λc 1260 1310 1360 nm - Extinction Ratio EX 9 - - db - Spectral Width (RMS) λ - - 4 nm - Side Mode Suppression Ratio SMSR 30 - - db - Optical Rise/Fall Time T rise /T fall - - 260 ps - Total Jitter TJ - - 260 ps Relative Intense Noise RIN - - -113 db/hz 4

Pout @TX-Disable Asserted P off - - -45 dbm - Eye Diagram IEEE Std 802.3-2005 1000BASE- compatible Receiver Optical Characteristics Table 7. Receiver Optical Characteristics Minimum Typical Maximum Notes Wavelength Range - 1470 1550 1600 nm - Receiver Sensitivity S - - -23 dbm 1 Receiver Overload P OL -3 - - dbm 1 Receiver optical path penalty - - - 1 db Optical Return Loss ORL 12 - - db - LOS De-Assert LOS D - - -24 dbm - LOS Assert LOS A -35 - - dbm - LOS Hysteresis - 0.5 3 5 db - Notes: 1. Measured with PRBS 2 7-1 test pattern, 1.25Gb/s, EX=9dB, BER<10-12. Timing characteristic Table 8.. Receiver Optical O Characteristics Minimum Typical Maximum Tx_disable assert time T_off - - 10 us - Tx_disable negate time T_on - - 1 ms - Time to initialize,include reset of TX_FAULT Notes T_init - - 300 ms - TX_FAULT from fault to assertion T_fault - - 100 us - Tx_disable time to start reset T_reset 10 - - us - Receiver LOS Assert Time(on to off) T_D,RX_LOS - - 80 us - Receiver LOS Assert Time(off to on) T_A,RX_LOS - - 80 us - Serial I2C Clock Rate I2C_Clock - - 100 khz - 5

Digital Diagnostic Memory Map LX21 Figure 2. Digital Diagnostic Memory Map Specific Data Field Descriptions EEPROM Serial ID Memory Contents The SFP MSA defines a 256-byte memory map in EEPROM describing the transceiver s capabilities, standard interfaces, manufacturer, and other information, which is accessible over a 2 wire serial interface at the 8-bit address 1010000X (A0h), and the clock frequency up to 100KHz. The memory contents are shown in Table 9. Table 9.. Serial ID Memory Contents Data Address Name of Field Contents(Hex) 0 Identifier 03 SFP Description 1 Ext. Identifier 04 SFP function is defined by serial ID 2 Connector 07 LC 3-10 Transceiver 00 00 00 40 00 00 00 00 11 Encoding 03 NRZ 12 BR, Nominal 0D 1.25Gb/s 13 Reserved 00-14 Length (9µm) km 14 20km 15 Length (9µm) 100m C8 20000m 16 Length (50µm) 10m 00-1000BASE-BX10-U 6

17 Length(62.5µm)10m 00-18 Length (Copper) 00-19 Reserved 00-20-35 Vendor name 36 Reserved 00 4C 49 4E 4B 54 45 4C 20 20 20 20 2020 20 20 20 37-39 Vendor OUI 00 00 00 40-55 Vendor PN 4C 58 32 31 33 32 xx 44 52 20 20 20 20 20 20 20 LINKTEL (ASCII) LX (ASCII) 56-59 Vendor rev 31 2E 30 20 Rev 1.0 ( ASCII) 60-61 Wavelength 05 1E 1310nm 62 Reserved 00 63 CC BASE xx Check sum of bytes 0-62 64-65 Options 00 1A LOS, TX_FAULT and TX_DISABLE 66 BR, max 00 67 BR, min 00 68-83 Vendor SN 84-91 Vendor date code xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx 20 20 ASCII Year (2 bytes), Month (2 bytes), Day (2 bytes) 92 Diagnostic type 68 Diagnostics (Internally Cal) 93 Enhanced option B0 Diagnostics(Optional Alarm/warning flags, Soft TX_FAULT and Soft TX_LOS monitoring) 94 SFF-8472 02 Diagnostics(SFF-8472 Rev 9.5) 95 CC_EXT xx Check sum for bytes 64-94 96-255 00 Note: The xx byte should be filled in according to practical case. For more information, please refer to the related document of SFF-8472 Rev 9.5. Diagnostic Monitor Specifications The digital diagnostic monitoring interface also defines another 256-byte memory map in EEPROM, which makes use of the 8 bit address 1010001X (A2h). Please see Figure 2. For detail EEPROM information, please refer to the related document of SFF-8472 Rev 9.5. The monitoring specification of this product is described in Table 10. 7

Table 10.. Diagnostic Monitor Specifications LX21 Range Accuracy Calibration Temperature LX2132CDR -15 to +80 C ±3 C Internal LX2132IDR -40 to +95 C ±3 C Internal Voltage 3.0 to 3.6V ±3% Internal Bias Current 0 to 70mA ±10% Internal TX Power -10 to -2dBm ±3dB Internal RX Power -24 to -2dBm ±3dB Internal Required Host Board Components The MSA power supply noise rejection filter is required on the host PCB to meet data sheet performance. The MSA filter incorporates an inductor which should be rated 400mA DC and 1Ω serial resistance or better. It should not be replaced with a ferrite. The required filter is illustrated in Figure 3. The MSA also specifies that 4.7KΩ to 10KΩ pull-up resistors for TX_FAULT, LOS, and MOD_DEF0,1,2 are required on the host PCB. Figure is the suggested transceiver/host interface. Figure 3 shows the recommended host board power supply circuit. Figure 3. Recommended Host Board Power Supply Circuit 8

Recommended Application Interface Circuit LX21 Figure 4. Recommended Application Interface Circuit Mechanical specifications Figure 5. Outline Drawing 9

PCB layout recommendation LX21 Figure 6. PCB layout recommendation 10

For More Information Linktel Technologies Co., Ltd sales@linkteltech.com Linktel China No.20 University Science Park Road, East Lake Hi-tech Development Zone, Wuhan, 430223, China Tel: +86 27-87929302 Linktel USA 3391 Ingersoll Ct., San Jose, CA 95148 Tel: +1-408-2613988 11