SFP+ BIDI Series JB1270-SFP-LC.S20

Similar documents
SFP+ BIDI Series GigaStream BIDI-10G-SFP-40A & BIDI-10G-SFP-40B

SFP+ Series. 1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

SFP+ BIDI Series JB1270-SFP-LC.S40. Features. Applications. Ordering information

Regulatory Compliance Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge To the enclosure Elect

SFP+ Series SFP-10G-SR

SFP+-10GB-ZR. 10Gbps SFP+ Optical Transceiver, 80km Reach

SFP+-CWDM-xx-40D. 10Gbps CWDM SFP+ Optical Transceiver, 40km Reach

SNR-SFP+W73-20 SNR-SFP+W db Power Budget BIDI SFP+ 10GbE Transceiver

SNR-SFP+LR-2 10Gbps. Applications 10GBASE-LR at 10.31Gbps 10GBASE-LW at 9.95Gbps Other optical links

SFP+-DWDM-xx-80D. 10Gbps DWDM SFP+ Optical Transceiver, 80km Reach

4.25Gbps SFP Transceiver

ASF Features. Applications. 1310nm SFP Single-Mode for 1.25G FC/GBE Duplex SFP Transceiver RoHS 6 Compliant

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

2.5Gbps SFP Transceiver

XFP BIDI Series JB1330-XFP-LC.S60. Features. Applications. Ordering information. Regulatory Compliance

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

SFP+ BIDI Series EOLP-BI1696-9ADL & EOLP-BI1696-9DAL Series

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

SFP Series IOLS-1624-XX-XX. 2.5Gbps APD High Sensitivity Receiver. version 0.1 FEATURES PRODUCT DESCRIPTION

SFP+ Series EOLP M-I. Features. Applications. Ordering information

XFP-BIDI-xx-10D. 10Gbps XFP Bi-Directional Transceiver, 10km Reach

OCTECH 1.25Gbps SFP Transceiver

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

1.25Gbps SFP Transceiver

DWDM SFP+ Series DWDM EML

OCTECH 1.25Gbps SFP Transceiver

1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

SFP28 Series Preliminary EOLP-8525G-02-R. Features. Applications. Ordering information

850nm SFP28 Multi-Mode Transceiver, With Diagnostic Monitoring and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type.

DWDM SFP+ Transceiver With Digital Diagnostic Function

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

PERFORMANCE SPECIFICATIONS - ELECTRICAL

SO-SFP-10GE-BX10D-3327-E

PERFORMANCE SPECIFICATIONS - ELECTRICAL

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-EW/ER Duplex SFP+ Transceiver, RoHS 6 Compliant. Fiber Type.

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

Ousent Technologies Co,.Ltd

WDM SFP+ модули предназначены для создания каналов связи по одноволоконному SM кабелю на расстояние до 20км.

SFP Series. Features. Applications. Ordering information. Single-Mode 155Mbps SC Single-Fiber SFP Transceiver RoHS6 Compliant

SNR-XFP-WXX-40 10Gbps

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gbps CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

4.25G 2km BIDI SFP Series

SFP Series. EOLS X Series. Features. Applications. Ordering Information. Multi-Mode 850nm 1xFC /GBE Duplex SFP Transceiver RoHS6 Compliant

SFP+ Series EOLP Features. Applications. Ordering information

SFP Series. EOLS-BI CL XX Series EOLS-BI LC XX Series. Features. Applications. Ordering Information

SFP-BIDI G 1310/1490nm BIDI

XFP Series JD1310-XFP-LC.S10. Features. Applications. Ordering information

DWDM SFP Series. Laser

Part No. Data Rate Fiber Distance Interface Temperature DDMI

SDH STM-1/SONET OC-3 SFP Transceiver With Digital Diagnostic Function. Applications: Features: Product Description

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

STM-1/OC-3 Bidirectional SFP Transceiver With Digital Diagnostic Function. Features: Applications: Product Description

SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

Laser TX/RX. Laser. Fiber Temp Rate. (nm)

Optical Transceiver Module - SFP

SFP-10G-LR-TX. Product Features. Applications. Product Selection. Cisco Compatible 10GBase-LR SFP TurboX

CWDM EML. SMF 23dB YES LC. note1: X refers to CWDM Wavelength range 1470nm to 1610nm, X=K~R, denotes 1470~1610nm.

SFP+ Series EOLP XN MSA Series

LEG. 10Gbs SFP+ Transceiver

XFP-10GB-LR. 10Gbps XFP Optical Transceiver, 10km Reach

XBR C. 8Gbs SFP+ Transceiver

SFP Series. Fiber Distance* (note2) Interface Temp. DDMI

SFP-1020-WA/B 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

GLC-LH-SMD-SO SFP, 1G, 10km, Single Mode, 1310nm, with DOM

10G SFP+ CWDM 20km Transceiver Hot Pluggable, Duplex LC, +3.3V, 1270~1350nm CWDM DFB, DDMI PSFP-2C41SF-XX

10G EPON Series. EOLS-PR-GEU-10 Series Preliminary. Features. Applications. Ordering information. Regulatory Compliance. Burst-M Part No.

Data Sheet. GPON OLT CLASS B+/C+ Transceiver With Digital Diagnostic Function. Applications: Features: Product Description

SFP-10G-SR-LEG. 10Gbs SFP+ Transceiver

Fiber Distance* (note2) Interface Temperature DDMI Rate

Part No. Input Output Burst-Mode Fiber Interface Temp. Feature Standard Performance. Class 1C (>1000 V) Method 3015.

DATASHEET 4.3. SFP+, 10GBase-LR, 1310nm, SM, DDM, 70km, RX sensitivity -22 dbm, Ind.temp.

10Gb/s DWDM Single-mode SFP+ Transceiver

SFP28 Series Preliminary EOLP-1325G-10-RX. Features. Applications. Ordering information

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

DWDM SFP Series. Laser

TSP-EB66-xxxxS. Data Sheet. 1.25G GEPON OLT Transceiver With Digital Diagnostic Function. Applications: Features: Product Description

10.3 Gb/s / 70 km / 1310 nm Digital Diagnostic SFP+ LC SINGLE-MODE TRANSCEIVER

DWDM SFP Series. DIxx-SFP-LC.S120. Features. Applications. Ordering Information

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

XTBxxA-20LY 10 Gbps SFP+ Bi-Directional Transceiver, 20 km Reach

DWDM SFP+ Series. EOLP XXXN series. Features. Applications. Ordering Information

SFP Series. EOLS X Series. Features. Applications. Ordering Information

1310nm SFP28 Single-Mode Transceiver, With DDM and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type Gbps 1310nm and DFB 28.

SFP Series. EOLS-1348-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm FC/2FC/4FC Duplex SFP Transceiver RoHS6 Compliant

SFP+ 10G Transceiver M10GB-SFP-BIDI10

LEG. 10Gbps SFP+ Transceiver

A block diagram of the HSFP10-2C21XX SFP+ optical transceiver is shown below

DWDM SFP+ Series DWDM EML DWDM EML

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

SFP Series EOLS X. Features. Applications. Ordering Information

10Gbps 1550nm 80KM SFP+ Optical Transceiver

10G CWDM SFP+ 40km ER Transceiver Hot Pluggable, Duplex LC, +3.3V, 1470~1610nm CWDM EML, DDMI PSFP10-1C41SF-XX

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

PRODUCT SPECIFACTION

SO-SFP-1000BASE-ZXD-I

Transcription:

JB1270-SFP-LC.S20 Tx: 1270nm/Rx: 1330nm BIDI SFP+ Transceiver for 10GbE RoHS 6 Compliant Features Operating data rate up to 10.3Gbps 1270nm DFB Transmitter/ 1330nm Receiver Power budget up to 12dB Single 3.3V Power supply and TTL Logic Interface LC Connector Interface Hot Pluggable Power Dissipation < 1.5W Operating Case Temperature Standard: 0~+70 Extended: -10~+85 Compliant with SFP+ MSA Specification SFF-8431 Applications Compliant with IEEE 802.3ae 10GBASE-LR 10GBASE-LR at 10.3125Gbps Compliant with IEEE 802.3ae 10GBASE-LW Compliant with SFF-8472 10GBASE-LW at 9.953Gbps Other Optical Links Ordering information Part No. Data Rate Laser Temp. Power budget Optical Interface DDMI JB1270-SFP-LC.S20 10.3Gbps 1270nm DFB Extended 12dB LC YES Page 1 of 10

Regulatory Compliance Feature Standard Performance Electrostatic Discharge MIL-STD-883G (ESD) to the Method 3015.7 Electrical Pins Class 1C (>1000 V) EN 55024:1998+A1+A2 Electrostatic Discharge IEC-61000-4-2 to the enclosure GR-1089-CORE Compliant with standards Compliant with standards Noise frequency range: 30 Electromagnetic Interference (EMI) FCC Part 15 Class B EN55022:2006 CISPR 22B :2006 VCCI Class B MHz to 6 GHz. Good system EMI design practice required to achieve Class B margins. System margins depend on customer host board and chassis design. Compliant with standards. 1kHz sine-wave, 80% AM, Immunity EN 55024:1998+A1+A2 from 80 MHz to 1 GHz. No IEC 61000-4-3 effect on transmitter/receiver performance is detectable between these limits. Laser Eye Safety FDA 21CFR 1040.10 and 1040.11 EN (IEC) 60825-1:2007 EN (IEC) 60825-2:2004+A1 CDRH compliant and Class I laser product. TüV Certificate No. 50135086 Component Recognition UL file E317337 UL and CUL TüV Certificate No. 50135086 EN60950-1:2006 (CB scheme ) RoHS6 2002/95/EC 4.1&4.2 2005/747/EC 5&7&13 Compliant with standards In light of item 5 in RoHS exemption list of RoHS Directive 2002/95/EC, Item 5: Lead in glass of cathode ray tubes, electronic components and fluorescent tubes. In light of item 13 in RoHS exemption list of RoHS Directive 2005/747/EC, Item 13: Lead and cadmium in optical and filter glass. The three exemptions are being concerned for our transceivers, because our transceivers use glass, which may contain Pb, for components such as lenses, isolators, and other electronic components. Page 2 of 10

Product Description JB1270-SFP-LC.S20 single mode transceiver is small form factor pluggable module for duplex optical data communications such as 10GBASE-LR/LW defined by IEEE 802.3ae. It is with the SFP+ 20-pin connector to allow hot plug capability. JB1270-SFP-LC.S20 module is designed for single mode fiber and operates at a nominal wavelength of 1270nm. The transmitter section uses a multiple quantum well DFB, which is class 1 laser compliant according to International Safety Standard IEC-60825. The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. Absolute Maximum Ratings* Note1 Parameter Symbol Min. Max. Unit Storage Temperature T S -40 +85 C Supply Voltage V CC -0.5 3.6 V *Note1: Exceeding any one of these values may destroy the device permanently. Recommended Operating Conditions Parameter Symbol Min. Typical Max. Unit Operating Case Temperature T A 0 +70 C Power Supply Voltage V CC 3.15 3.3 3.45 V Power Supply Current I CC 430 ma Surge Current I Surge +30 ma Operating Case Temperature T c -10 85 C Baud Rate 9.953/10.3125 GBaud Performance Specifications - Electrical Parameter Symbol Min. Typ. Max Unit Notes CML Inputs(Differential) Input Impedance (Differential) Tx_DISABLE Input Voltage - High Tx_DISABLE Input Voltage - Low Tx_FAULT Output Voltage - High Tx_FAULT Output Voltage - Low Transmitter Vin 150 1200 mvpp Zin 85 100 115 ohms 2 Vcc+0.3 V 0 0.8 V 2 Vcc+0.3 V Page 3 of 10 AC coupled inputs Rin > 100 kohms @ DC Io = 400µA; Host Vcc 0 0.5 V Io = -4.0mA

CML Outputs (Differential) Output Impedance (Differential) Rx_LOS Output Voltage - High Rx_LOS Output Voltage - Low MOD_DEF (2:0 ) Receiver Vout 350 700 mvpp AC coupled outputs Zout 85 100 115 ohms 2 Vcc+0.3 V lo = 400µA; Host Vcc 0 0.8 V lo = -4.0mA VoH 2.5 V VoL 0 0.5 V With Serial ID Optical and Electrical Characteristics Parameter Symbol Min. Typical Max. Unit Power budget 12 db Data Rate 9.953/10.3125 Gbps Transmitter Centre Wavelength λ C 1260 1270 1280 nm Spectral Width (-20dB) λ 1 nm Average Output Power *note4 P out, AVG -2 3 dbm Extinction Ratio ER 3.5 db Side Mode Suppression Ratio SMSR 30 db Transmitter and Dispersion Penalty TDP 2 db Average Power of OFF Transmitter -30 dbm Relative Intensity Noise RIN -128 db/hz Input Differential Impedance Z IN 90 100 110 Ω TX Disable Assert Time t_off 10 us Receiver Centre Wavelength λ C 1320 1340 nm Sensitivity *note5 P IN -14 dbm Receiver Overload P MAX 0.5 dbm Output Differential Impedance P IN 90 100 110 Ω LOS LOS De-Assert LOS D -18 dbm LOS Assert LOS A -30 dbm High 2.0 V CC +0.3 Low 0 0.8 V Page 4 of 10

SFP+ Transceiver Electrical Pad Layout SFP+ BIDI Series Pin Function Definitions Pin Num. Name FUNCTION Plug Seq. Page 5 of 10 Notes 1 VeeT Transmitter Ground 1 Note 5 2 TX Fault Transmitter Fault Indication 3 Note 1 3 TX Disable Transmitter Disable 3 Note 2, Module disables on high or open 4 SDA Module Definition 2 3 2-wire Serial Interface Data Line. 5 SCL Module Definition 1 3 2-wire Serial Interface Clock.

6 MOD_ABS Module Definition 0 3 Note 3 7 RS0 Rate Select 0, optionally controls SFP+ RX Rate Select 3 module receiver. This pin is pulled low to (LVTTL). VeeT with a >30K resistor.. 8 LOS Loss of Signal 3 Note 4 9 RS1 Rate Select 1, optionally controls SFP+ TX Rate Select 1 module transmitter. This pin is pulled low to (LVTTL). VeeT with a >30K resistor. 10 VeeR Receiver Ground 1 Note 5 11 VeeR Receiver Ground 1 Note 5 12 RD- Inv. Received Data Out 3 Note 6 13 RD+ Received Data Out 3 Note 6 14 VeeR Receiver Ground 1 Note 5 15 VccR Receiver Power 2 3.3V ± 5%, Note 7 16 VccT Transmitter Power 2 3.3V ± 5%, Note 7 17 VeeT Transmitter Ground 1 Note 5 18 TD+ Transmit Data In 3 Note 8 19 TD- Inv. Transmit Data In 3 Note 8 20 VeeT Transmitter Ground 1 Note 5 Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT/R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7K 10 KΩ resistor. Its states are: Low (0 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Module Absent, connected to VeeT or VeeR in the module. 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor. Pull up voltage between 2.0V and VccT/R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 5) The module signal ground contacts, VeeR and VeeT, should be isolated from the module case. 6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 350 and 700 mv differential (175 350 mv single ended) when properly terminated. Page 6 of 10

7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP+ connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP+ input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP+ transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SFP+ transceiver module. 8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 150 1200 mv (75 600mV single-ended). EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not writing protected within the SFP+ transceiver. The negative edge clocks data from the SFP+ transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. If the module is defined as external calibrated, the diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2h. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 10.2. Page 7 of 10

Page 8 of 10

Recommend Circuit Schematic SFP+ BIDI Series Mechanical Specifications Page 9 of 10

Eye Safety This single-mode transceiver is a Class 1 laser product. It complies with IEC-60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug. Page 10 of 10