Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Similar documents
Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

ph / ORP Measurement mypro CPM 431

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS15 and CLS15D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D

Technical Information Condumax CLS21D/CLS21

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Conductivity Measurement mycom CLM 152

Endress Hauser The Power of Know How. Turbidity and Solids Content Sensor TurbiMax P CUS 63 / CUS 63H

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D

Indumax CLS50/CLS50D. Technical Information

Condumax W CLS15 and CLS15D

Temperature measurement TMD 832 head transmitter

Technical Information Condumax CLS15D/CLS15

Conductivity measurement SmarTec S CLD 132

Temperature transmitter itemp PCP DIN rail TMT 121

Technical Information Memosens CLS82D

itemp HART DIN rail TMT112

Technical Information Smartec CLD18

Technical Information Indumax CLS50D/CLS50

Temperature Transmitters TMT 136, TMT 137

Technical Information Smartec CLD18

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

0 2 1 â Ó. itemp HART TMT182. Technical Information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Condumax CLS16 and CLS16D

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Liquisys M CLM223/253

Coriolis Massflowmeter

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Coriolis Massflowmeter

System Components Liquiphant M (NAMUR)/PROFIBUS-PA interface FXA 164

The transducer component converts the measured signal and displays the actual value.

itemp PA TMT184 Technical information

Ceramax CPS341D. Technical Information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Temperature transmitter with local display RIT 261

Memosens CPS96D. Technical Information

Orbipac CPF81/CPF82 and CPF81D/CPF82D

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Level Limit Switch nivotester FTL 370, FTL 372

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z

Resistance thermometer Model TR30, compact design

Conductivity Transmitter

Technical Information Smartec CLD18

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Resistance thermometer Model TR30, compact design

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital inductive conductivity transmitter

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

ph or ORP Transmitter

Positioner with HART Communication Type 3780

Technical Information Liquisys M CLM223/253

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

OEM radar transmitter, for aggressive media level measurement

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Temperature Transmitter itemp RTD DIN rail TMT 127

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure transmitter for general industrial applications Model A-10

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

0 2 1 â Ó. itemp HART TMT182. Technical Information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Indumax CLS54D. Technical Information

Head mounted Temperature Transmitter TF02/TF02-Ex

Coriolis Mass Flow Meter Model TM

SALES SERVICE +358 (0)

Measuring and Controlling Unit Multronic OC

Level Measurement silometer FMX 570

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

Coriolis Massflowmeter

Miniature resistance thermometer Model TR33, thread-mounted

Temperature head transmitter itemp PCP TMT 181

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Resistance thermometer Model TR31, miniature design

Resistance thermometer Model TR30, compact design

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure transmitter for general industrial applications Model A-10

Technical Information Orbipore CPS91D and CPS91

Conductivity Analyzer

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Power supply. Calibration. Surface finishing. Seal. Process connection

Vortex Flow Measuring System prowirl 77

TMU. Coriolis Mass Flow Meter. for liquids and gas

Transcription:

Technical Information TI 202C/07/en No. 51500563 Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive Two-wire transmitter for conductive measurement of conductivity and specific resistance in Ex and non-ex areas with HART or PROFIBUS communication The MyPro CLM 431 and its compact version MyPro CLD 431 are field-tested and reliable analytical transmitters used to determine conductivity or specific resistance in all areas of process control and engineering. Thanks to its compact dimensions and versatile mounting options, the MyPro can be used in any industrial environment. Areas of application Chemical and petrochemical industries, including Ex areas Pharmaceutical industry Power plants Water processing Wastewater treatment Benefits at a glance High reliability and accuracy thanks to: comprehensive self-monitoring functions polarisation detection convenient calibration functions for wet and dry calibration Smallest intelligent analytical transmitter currently available Extremely simple installation with numerous mounting options; display and housing can be rotated Convenient operation via: keypad on instrument hand-held HART terminal Commuwin II via HART or PROFIBUS-PA Additional advantages of compact version Minimal installation requirements Simple handling Rugged stainless steel measuring cells Quality made by Endress+Hauser ISO 9001 Endress +Hauser Nothing beats know-how

Measuring system A measuring system generally comprises: the MyPro transmitter a conductive two-electrode measuring cell with an integrated temperature sensor Pt 100 a fitting for weld-mounting or an assembly for installation in a pipeline or tank an additional measuring cable for the CLM 431 version Conductivity measuring cells MyPro CLM 431 MyPro CLD 431 with CLS 12 CLS 15 Examples of measuring system configurations CLA 111 with CLS 21 Measuring cable, e.g. CYK 71 TI172Y01.CDR Conductivity measuring cells for MyPro CLM 431 conductive CLS 21 k =1 CLS12/13/15/19 k =0.1 CLS12/13/15/19 k=0.01 0.01 0.1 1 10 100 1 10 100 1000 µs/cm Conductivity ms/cm CLS12/13/15/19 k=0.1 CLS12/13/15/19 k=0.01 100 10 1 0.1 0.01 0.001 Application ranges of conductive two-electrode measuring cells M Ω cm Specific resistance TI172E02.CDR The MyPro CLM 431 / CLD 431 transmitter has an overall measuring range of 0... 2000 ms/cm which may be spread as required by the application at hand. Selecting the correct measuring cell for the application is extremely important since the application range of measuring cells is subject to physical limitations. 2

General information Measurement The conductive measuring transmitter MyPro CLM 431 / CLD 431 can be switched from conductivity to specific resistance measurement. Accuracy is the top priority. Continued accuracy is guaranteed by a cyclical adjustment routine. Self-diagnosis The MyPro permanently monitors the operating condition of the measuring system. 22 possible causes of errors are distinguished. Error conditions are signalled via the field display and the HART or Profibus interface and, in the case of HART communication, also via an error current signal (22 ma). Temperature compensation The MyPro offers several temperature compensation options: Linear compensation: 0... 10%/K with the reference temperature selectable by the user Compensation according to IEC 746-3 for NaCl Temperature compensation for ultrapure water with trace impurities Compensation with user-programmable α table containing up to 10 elements The temperature can either be measured continuously or entered as a fixed value. Polarisation detection High ion concentrations at the boundary layer between the electrode and the medium impede free ion movement. These so-called polarisation effects limit the measuring range of conductive measuring cells. Soiling and coatings may also lead to polarisation within the specified measuring range of the measuring cell and produce inaccurate results. The conductive measuring transmitter MyPro CLM 431 / CLD 431 employs the latest findings in metrology to safely detect polarisation effects. Polarisation detection is available for two-electrode measuring cells in the conductivity measuring range and can be activated by the user. Polarisation detection 22 ma POL.CDR Operation Menu-guided operation The functions of the MyPro CLM 431 / CLD 431 are arranged at two different levels and can be accessed using four keys: Operating level 1 Viewing of current settings (secondary parameters) Error diagnosis (diagnostic parameters) Current output settings (parameter settings) Calibration Operating level 2 All other settings are located at this level, e.g. selection of conductivity or resistance measurement. The keypad is located underneath a protective cover to prevent unintentional actuation and soiling. No unauthorised access Configuration and calibration data are protected against undesirable modification by means of two access codes. Display The high-contrast liquid crystal display locks in at 90 angles to guarantee optimal readability in different mounting positions. Display ANZEIGE.CDR 3

Test HART Handterminal 1 Offline 2 Online 3 Transfer 4 Frequenzg erät 5 Extras I O Test Operation (continued) Keypad on instrument + C F F > 3 s Operating level 1 Daily work and diagnosis Operating level 2 Configuration and diagnosis Hand-held HART terminal Plain text menu guidance Operation of MyPro CLM 431 / CLD 431 via: keys on instrument hand-held HART terminal Commuwin II Commuwin II via HART or PROFIBUS-PA Clear overall view in the form of a matrix Graphical user interface Data entry/recorder function Upload/download archiving Off-line parameter setting TI195Y04.CDR Electrical connection + 4...20 ma 1 2 ➀ + 4...20 ma 1 2 ➀ Terminal 3 is unused Supply voltage: 12... 30 V + 4...20 ma 0000 Electrical connection of MyPro CLM 431 / CLD 431 (HART version): ➀ Connection compartment for two-wire line ➁ Connection compartment for measuring cell cable ➂ Power supply / signal output connection ➁ + Test 1 3 2 ➂ Signal output: 4... 20 ma Warning: Observe national regulations for installation in Ex area! TI172Y05.CDR 11 12 13 gn wt ye 1 2 4 5 Measuring cable The MyPro CLM 431 transmitter comes with separate connection compartments for the two-wire line and the measuring cell cable. The conductivity measuring cells are connected via standard screened, multi-core measuring cables of the type CYK 71. Junction box VS is to be used for measuring cable extension. bn Connection compartment CYK 71 gn wt ye Connection of a conductive two-electrode measuring cell with cable CYK 71 ϑ Conductive two-electrode measuring cell, e.g. CLS 12 / 13 / 15 / 19 / 21 LM431KE2.CDR 4

Dimensions of MyPro CLM 431 104 137 227 53 74 Dimensions of MyPro CLM 431 MASSCLM.CDR 5

Dimensions of MyPro CLD 431 conductive 104 137 115 53 321 G 1 25 Dimensions of MyPro CLD 431 conductive MASSCLDC.CDR Mounting of MyPro CLD 431 conductive flow direction Pipe mounting of MyPro CLD 431 conductive EINBAU2.CDR 6

Pipe mounting of MyPro CLM 431 Left: Pipe mounting DN 60 with mounting bracket Right: Pipe mounting DN 30... 200 with mounting bracket (horizontal attachment) MOUNT3D1.CDR MOUNT3D2.CDR 82 8 53 60.3 30... 200 165 77 102 84 6 77 Left: Pipe mounting DN 60 with mounting bracket Right: Pipe mounting DN 30... 200 with mounting bracket (vertical attachment) MOUNT2D1.CDR MOUNT2D2.CDR 7

Flange and wall mounting of MyPro CLM 431 MOUNT3D3.CDR MOUNT3D4.CDR 69 Left: Flange mounting with angle bracket Right: Wall mounting with mounting bracket 160 254 118 53 177 97 Left: Flange mounting with angle bracket Right: Wall mounting with mounting bracket MOUNT2D3.CDR MOUNT2D4.CDR 8

Technical data MyPro CLM 431 conductive General specifications Manufacturer Endress+Hauser Product designation MyPro CLM 431 conductive Physical data Dimensions (H W D) 227 104 137 mm Weight max. 1.25 kg Protection type IP 65 Housing material GD-AlSi 10 Mg, plastic-coated Measured value display liquid crystal display Conductivity/resistance measurement Measuring range 0... 60 ms/cm; 0... 2 MΩ cm Measurement deviation 1 ±0.5% of measured value ± 4 digits Reproducibility 1 ±0.1% of measured value ± 2 digits Usable cell constant k = 0.0025... 99.99 cm 1 Max. measuring cable length (CYK 71) conductivity: 100 m; resistance: 15 m Max. resolution (in most sensitive measuring range) 10 ns/cm Temperature measurement Temperature sensor to be connected Pt 100 Measuring range of Pt 100 35... +250 C Measurement deviation 1 (entire measuring range) max. 0.5% of measuring range Measured value resolution 0.1 C Reproducibility 1 ±0.1 K Adjustable temperature offset ±20 C Temperature compensation Compensation types linear, NaCl, ultrapure water, table Range 35... +250 C Reference temperature adjustable; factory setting 25 C Signal output Current range 4... 20 ma Accuracy ± 22 µa + 0.5 µa I real /ma T/K T= T a 25 C for T a 25 C T = 25 C T a for T a < 25 C Load max. 820 Ω Resolution < 6 µa Electrical data Supply voltage 12... 30 V DC Power consumption max. 660 mw Signal output 4... 20 ma, potential separated from meas. cell circuit Error current signal output 22 ma ± 0.02 ma HART transfer: load 250... 820 Ω HART transfer: signal output 0.8... 1.2 ma (peak to peak) Terminals, max. cable cross section 2.5 mm², screen 4 mm² Ex version CLM 431-G Intrinsically safe power supply and signal circuit, protection type EEx ib IIC T4 Max. input voltage U i 30 V DC Max. input current I i 100 ma Max. input power P i 750 mw Max. internal inductance L i 200 µh Max. internal capacitance C i 0, to screen = 5.3 nf Intrinsically safe measuring cell circuit, protection type EEx ia IIC T4 Max. output voltage U o ±5.4 (10.8) V DC Max. output current I o 320 ma Max. output power P o 200 mw Max. external inductance L o 100 µh Max. external capacitance C o 100 nf 9

Technical data (continued) CLM 431-H Intrinsically safe power supply and signal circuit, protection type EEx ib IIC T4 Max. input voltage U i 30 V DC Max. input current I i 100 ma Max. input power P i 750 mw Max. internal inductance L i 200 µh Max. internal capacitance C i 0, to screen = 5.3 nf Intrinsically safe measuring cell circuit, protection type EEx ia IIC T4 Max. output voltage U o ±6.3 (12.6) V DC Max. output current I o 130 ma Max. output power P o 211 mw Max. external inductance L o 100 µh Max. external capacitance C o 100 nf Ambient conditions Electromagnetic compatibility (EMC) interference emission and interference immunity acc. to EN 61326-1:1998 Ambient temperature T a (nom. operating conditions) 15... +55 C Relative humidity (nominal operating conditions) 10... 95%, non-condensing Ambient temperature T a (limit operating conditions) 20... +60 C (Ex: 20... +55 C) Storage and transport temperature 20... +70 C Vibration stability acc. to IEC 770 Mounting position pipeline Vibration frequency 10... 60 Hz Maximum amplitude 0.21 mm MyPro CLD 431 conductive General specifications Manufacturer Endress+Hauser Product designation MyPro CLD 431 conductive Physical data Length with CLS 12 321 mm Process connection G 1 Weight approx. 2 kg Protection type IP 65 Housing material GD-AlSi 10 Mg, plastic-coated Materials in contact with medium stainless steel 1.4571 (SS 316Ti), Viton, ceramic Measured value display liquid crystal display Conductivity/resistance measurement Measuring cell CLS 12 Conductivity measuring range, version CA / CB 0.04... 20 µs/cm / 0.1... 200 µs/cm Resistance measuring range, version CA / CB 0.05... 25 MΩ cm / 0.005... 10 MΩ cm Cell constant, version CA / CB k = 0.01 cm 1 / 0.1 cm 1 Other data See MyPro CLM 431 conductive 1 acc. to IEC 746-1, for nominal operating conditions Subject to modifications. [ C] Ambient temperature 60 55 50 40 30 20 10 Ex area Non-Ex area 0 20 40 55 85 60 80 100 120 140 160 [ C] Permissible temperature ranges MyPro CLD 431 Medium temperature TDIAGR.CDR 10

Product structure Conductivity measuring transmitter MyPro CLM 431 conductive Certificate type A Version for non-ex area G Cenelec EEx ia/ib IIC T4 H Cenelec EEx ia/ib IIC T4 (dir. 76/117/EEC, dir. 94/9/EC) Cable entry for power supply 1 Cable gland Pg 13.5 3 Cable entry M 20 1.5 5 Cable entry NPT ½" 7 Cable entry G ½ 8 Cable entry M 12 Electronics, communication, display A 4... 20 ma, HART, without display B 4... 20 ma, HART, LCD C PROFIBUS-PA, without display D PROFIBUS-PA, LCD Accessories 1 No accessories 2 For wall and pipe mounting (DN 60) 3 For wall and pipe mounting (DN 30... 200) 4 With flange mounting angle Preset measuring parameter C Conductive, two-electrode measurement M Conductive, resistance measurement Cable, measuring cell connection A Cable not included C With 1 m CYK 71 cable E With 2 m CYK 71 cable CLM 431- complete order code Compact conductivity measuring system MyPro CLD 431 conductive Certificate type A Version for non-ex area H Cenelec EEx ia/ib IIC T4 (dir. 76/117/EEC, dir. 94/9/EC) Cable entry for power supply 1 Cable gland Pg 13.5 3 Cable entry M 20 1.5 5 Cable entry NPT ½" 7 Cable entry G ½ 8 Cable entry M 12 Electronics, communication, display A 4... 20 ma, HART, without display B 4... 20 ma, HART, LCD C PROFIBUS-PA, without display D PROFIBUS-PA, LCD Accessories 1 No accessories Measuring cell, process connection, material CA CLS 12 / 0.04... 20 µs/cm, G 1, SS 316Ti CB CLS 12 / 0.1... 200 µs/cm, G 1, SS 316Ti CLD 431- complete order code 11

Accessories Transmitter power supply units RN 221 power separator (non-ex) RN 221 Z power separator (Ex) NX 9120 power supply (one channel, non-ex) NX 9121 power supply unit (three channels, Ex) One-channel transmitter power supply units with galvanically separated power output Output voltage: Output current: Current limiting: typ. 24 V DC ± 1 V max. 33 ma 38 ma ± 5 ma Hand-held HART terminal DXR 275 The hand-held terminal communicates with any HART -compatible unit via the 4... 20 ma line. The digital communication signal is superimposed on the 4... 20 ma signal without altering it. The simple, straightforward design of the user interface provides convenient access to the entire functionality of the instrument. Commuwin II with Commubox Commuwin II is a graphical, PC-based operating program for intelligent measuring instruments. DDE interfaces (DDE = dynamic data exchange, Windows communication standard) are used for communication between Commuwin II and measuring transmitters. One DDE server (driver) per communication channel is available. Depending on the application, either the serial interface built into the personal computer or a special interface (card to be plugged into the PC) is used. The Commubox serves as the required interface module between the HART interface and the serial PC interface. Measuring cable CYK 71 For two-electrode measuring cells with a temperature sensor. Order no. 50085333 Junction box VS Junction box with receptacle and 7-pin connector for extension of measuring cable connection between measuring cell and instrument. Protection type: IP 65. Order no. 50001054 Calibration solutions Precision solutions referred to SRM by NIST; error limit 0.5%, reference temperature 25 C; quantity 500 ml. See Technical Information CLY 11, order no. 50086574. Type Conductivity 1 Order no. CLY 11-A 74.0 µs/cm 50081902 CLY 11-B 149.6 µs/cm 50081903 CLY 11-C 1.406 ms/cm 50081904 CLY 11-D 12.64 ms/cm 50081905 CLY 11-E 107.00 ms/cm 50081906 1 Values may deviate due to manufacturing tolerances. The error limit refers to the value specified on the bottle. Endress+Hauser GmbH+Co. - Instruments International - P.O. Box 2222 D-79574 Weil am Rhein Tel. (0 76 21) 975-02 Fax (0 76 21) 97 53 45 Endress +Hauser Nothing beats know-how TI 202C/07/en/07.99 Printed in Germany / DT / CV5 (51500563)